Sergio Richter
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sergio Richter has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Philipp Sommer
Universität Leipzig – Herzzentrum
5 shared publications - Gerhard Hindricks
Department of Electrophysiology, Heart Center Leipzig, Leipzig, Germany
4 shared publications - Sascha Rolf
Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany
4 shared publications - Ole Alexander Breithardt
Department of Electrophysiology, University of Leipzig, Heart Center, Leipzig, Germany
3 shared publications - Andreas Bollmann
Department of Electrophysiology, Heart Center Leipzig, Leipzig, Germany
2 shared publications - Arash Arya
Department of Electrophysiology, Heart Center, University of Leipzig, Leipzig, Germany
2 shared publications
Latest Publications
- 17 September 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 167-175
Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy
Introduction Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real‐time 3‐D location of sensor‐embedded delivery tools superimposed on prerecorded X‐ray cine‐loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation. Methods and Results Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin‐to‐skin) was 4.9 (2.5–7.8) minutes with a median dose‐area‐product of 476 (260–1056) cGy*cm2. An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm2, respectively (P = 0.044 ). Conclusion Use of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation.
- 17 September 2014
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 26 (2) , 167-175
Sensor‐Based Electromagnetic Navigation to Facilitate Implantation of Left Ventricular Leads in Cardiac Resynchronization Therapy
Introduction Implantation of cardiac resynchronization therapy (CRT) devices can be challenging, time consuming, and fluoroscopy intense. To facilitate placement of left ventricular (LV) leads, a novel electromagnetic navigation system (MediGuide™, St. Jude Medical, St. Paul, MN, USA) has been developed, displaying real‐time 3‐D location of sensor‐embedded delivery tools superimposed on prerecorded X‐ray cine‐loops of coronary sinus venograms. We report our experience and advanced progress in the use of this new electromagnetic tracking system to guide LV lead implantation. Methods and Results Between January 2012 and December 2013, 71 consecutive patients (69 ± 9 years, 76% male) were implanted with a CRT device using the new electromagnetic tracking system. Demographics, procedural data, and periprocedural adverse events were gathered. The impact of the operator's experience, optimized workflow, and improved software technology on procedural data were analyzed. LV lead implantation was successfully achieved in all patients without severe adverse events. Total procedure time measured 87 ± 37 minutes and the median total fluoroscopy time (skin‐to‐skin) was 4.9 (2.5–7.8) minutes with a median dose‐area‐product of 476 (260–1056) cGy*cm2. An additional comparison with conventional CRT device implantations showed a significant reduction in fluoroscopy time from 8.0 (5.8; 11.5) to 4.5 (2.8; 7.3) minutes (P = 0.016) and radiation dose from 603 (330; 969) to 338 (176; 680) cGy*cm2, respectively (P = 0.044 ). Conclusion Use of the new navigation system enables safe and successful LV lead placement with improved orientation and significantly reduced radiation exposure during CRT implantation.
- 22 August 2014
- Vol. 78 (10) , 2402-7
Comparison of dabigatran and uninterrupted warfarin in patients with atrial fibrillation undergoing cardiac rhythm device implantations. Case-control study.
The incidence of postoperative complications following pacemaker or implantable cardioverter-defibrillator implantations in patients treated with new oral anticoagulation agents has not been studied. Here we present a first comparison of complications after cardiac rhythm device (CRD) implantations in patients with atrial fibrillation (AF) treated with dabigatran or uninterrupted warfarin. Using a case-control study design, we compared complications within 30 days after 236 CRD procedures performed under uninterrupted warfarin (n=118) or interrupted dabigatran (n=118).There were no significant differences in the baseline characteristics of both groups. In the warfarin group, 9 (8%) pocket hematomas were observed vs. 3 (3%) in the dabigatran group (P=0.075). Two complications in the warfarin group necessitated surgical intervention as opposed to none in the dabigatran group (P=0.156). The postprocedural blood loss expressed as a drop in hemoglobin was significantly greater in the warfarin group (-0.9±0.7 vs. -0.5±0.4 mmol/L, P=0.023). In the dabigatran group, 1 case of transient ischemic attack occurred. The mean time to hospital discharge was shorter in patients treated with dabigatran (2.5±2.3 vs. 3.8±4.1 days, P=0.02). The incidence and severity of bleeding complications may be lower in patients treated with periprocedurally discontinued dabigatran when compared with uninterrupted warfarin therapy. Further evaluation of peri-interventional complications and establishment of an optimal anticoagulation management protocol are needed.
- 22 August 2014
- Vol. 78 (10) , 2402-7
Comparison of dabigatran and uninterrupted warfarin in patients with atrial fibrillation undergoing cardiac rhythm device implantations. Case-control study.
The incidence of postoperative complications following pacemaker or implantable cardioverter-defibrillator implantations in patients treated with new oral anticoagulation agents has not been studied. Here we present a first comparison of complications after cardiac rhythm device (CRD) implantations in patients with atrial fibrillation (AF) treated with dabigatran or uninterrupted warfarin. Using a case-control study design, we compared complications within 30 days after 236 CRD procedures performed under uninterrupted warfarin (n=118) or interrupted dabigatran (n=118).There were no significant differences in the baseline characteristics of both groups. In the warfarin group, 9 (8%) pocket hematomas were observed vs. 3 (3%) in the dabigatran group (P=0.075). Two complications in the warfarin group necessitated surgical intervention as opposed to none in the dabigatran group (P=0.156). The postprocedural blood loss expressed as a drop in hemoglobin was significantly greater in the warfarin group (-0.9±0.7 vs. -0.5±0.4 mmol/L, P=0.023). In the dabigatran group, 1 case of transient ischemic attack occurred. The mean time to hospital discharge was shorter in patients treated with dabigatran (2.5±2.3 vs. 3.8±4.1 days, P=0.02). The incidence and severity of bleeding complications may be lower in patients treated with periprocedurally discontinued dabigatran when compared with uninterrupted warfarin therapy. Further evaluation of peri-interventional complications and establishment of an optimal anticoagulation management protocol are needed.
- 27 February 2014
- Published by Elsevier in Heart Rhythm
- Vol. 11 (5) , 871-876
Adenosine sensitivity of retrograde fast pathway conduction in patients with slow-fast atrioventricular nodal reentrant tachycardia: A prospective study
- 27 February 2014
- Published by Elsevier in Heart Rhythm
- Vol. 11 (5) , 871-876
Adenosine sensitivity of retrograde fast pathway conduction in patients with slow-fast atrioventricular nodal reentrant tachycardia: A prospective study
- Open Access
- 31 January 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (7) , 1028-1032
Treatment with novel oral anticoagulants in a real-world cohort of patients undergoing cardiac rhythm device implantations
The safety and efficacy of novel oral anticoagulants in patients with atrial fibrillation undergoing pacemaker or implantable cardioverter-defibrillator interventions have not been clearly defined. Therefore, we compared the incidence of bleeding and thrombo-embolic complications following cardiac rhythm device (CRD) implantations under dabigatran vs. rivaroxaban in a real-world cohort. We analysed 176 consecutive procedures performed in 93 patients treated peri-interventionally with dabigatran and 83 patients with rivaroxaban, respectively. Post-operative bleeding complications and thrombo-embolic events occurring within 30 days were compared. There were no significant differences in baseline characteristics between patients in the dabigatran and the rivaroxaban group. Most of the patients in both the groups received dual chamber or cardiac resynchronization devices (71 vs. 78%) as opposed to single-chamber systems (29 vs. 22%). In the dabigatran group, two (2%) bleeding complications (two pocket haematomas) were observed in comparison with four (5%, three pocket haematomas and one pericardial effusion) in the rivaroxaban group (P = 0.330). Three complications in the rivaroxaban group necessitated surgical intervention as opposed to none in the dabigatran group (P = 0.064). One case of a transient ischaemic attack occurred in the dabigatran group (P = 0.343). Bleeding and thrombo-embolic complications in patients treated with dabigatran or rivaroxban are rare. Further and larger studies are warranted to define the optimal anticoagulation management in patients with a need for oral anticoagulation and CRD interventions.
- 31 January 2014
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 16 (7) , 1028-1032
Open AccessTreatment with novel oral anticoagulants in a real-world cohort of patients undergoing cardiac rhythm device implantations
The safety and efficacy of novel oral anticoagulants in patients with atrial fibrillation undergoing pacemaker or implantable cardioverter-defibrillator interventions have not been clearly defined. Therefore, we compared the incidence of bleeding and thrombo-embolic complications following cardiac rhythm device (CRD) implantations under dabigatran vs. rivaroxaban in a real-world cohort. We analysed 176 consecutive procedures performed in 93 patients treated peri-interventionally with dabigatran and 83 patients with rivaroxaban, respectively. Post-operative bleeding complications and thrombo-embolic events occurring within 30 days were compared. There were no significant differences in baseline characteristics between patients in the dabigatran and the rivaroxaban group. Most of the patients in both the groups received dual chamber or cardiac resynchronization devices (71 vs. 78%) as opposed to single-chamber systems (29 vs. 22%). In the dabigatran group, two (2%) bleeding complications (two pocket haematomas) were observed in comparison with four (5%, three pocket haematomas and one pericardial effusion) in the rivaroxaban group (P = 0.330). Three complications in the rivaroxaban group necessitated surgical intervention as opposed to none in the dabigatran group (P = 0.064). One case of a transient ischaemic attack occurred in the dabigatran group (P = 0.343). Bleeding and thrombo-embolic complications in patients treated with dabigatran or rivaroxban are rare. Further and larger studies are warranted to define the optimal anticoagulation management in patients with a need for oral anticoagulation and CRD interventions.
- 21 February 2011
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (8) , 886-891
Effect of Limb Lead Electrodes Location on ECG and Localization of Idiopathic Outflow Tract Tachycardia: A Prospective Study
- 21 February 2011
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 22 (8) , 886-891
Effect of Limb Lead Electrodes Location on ECG and Localization of Idiopathic Outflow Tract Tachycardia: A Prospective Study
- 12 December 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (12) , 1317-1319
Beat-to-Beat Cycle Length Variation During Narrow QRS Complex Tachycardia: What Is the Mechanism?
- 12 December 2005
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 28 (12) , 1317-1319
Beat-to-Beat Cycle Length Variation During Narrow QRS Complex Tachycardia: What Is the Mechanism?