Influence of Cap Thickness on Corneal Curvature and Corneal Biomechanics After SMILE: A Prospective, Contralateral Eye Study
Authors:
- De WuDWDe Wu
- Chunlei LiuCLChunlei Liu
- Bin LiBLBin Li
- Diya WangDWDiya Wang
- Xuejun FangXFXuejun Fang
- 1 February 2020
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 36 (2) , 82-88
Abstract
PURPOSE: To evaluate the impact of cap thickness for small incision lenticule extraction (SMILE) on changes in corneal curvature and biomechanics. METHODS: One hundred eyes (50 patients) were enrolled in this prospective contralateral eye study. The difference in manifest refraction spherical equivalent (MRSE) in the same patient was less than 0.50 diopters. SMILE was performed with a randomized cap thickness of 110 µm in one eye and 140 µm in the other eye. MRSE, uncorrected distance visual acuity (UDVA), and corneal curvature and biomechanics were evaluated. The anterior and posterior surfaces of the corneal curvature (mean keratometry [Km] values 2, 4, and 6 mm from the pupil center) were measured by Pentacam HR (Oculus Optikgeräte, Wetzlar, Germany) and changes in corneal biomechanics at 6 months postoperatively by Scheimpflug technology. RESULTS: There was no significant between-group difference in UDVA or MRSE postoperatively. Postoperative changes in Km at the anterior surface (ΔKm-ant) in the 4-mm zone were significantly higher in the 110-µm group than in the 140-µm group at 1 day and 1, 3, and 6 months postoperatively ( P = .043, .045, .003, and .049, respectively); at 3 months, the ΔKm-ant in the 6-mm zone was higher in the 110-µm group ( P = .035). The changes in second appla-nation time, deformation amplitude, and integrated radius were significantly less in the 110-µm group ( P = .031, .049, and < .001, respectively). CONCLUSIONS: A thicker corneal cap caused less change in anterior surface curvature after SMILE for moderate or low myopia, with no significant difference in UDVA and MRSE. [ J Refract Surg . 2020;36(2):82–88.]Keywords
This publication has 18 references indexed in Scilit:
- Corneal Cap Thickness and Its Effect on Visual Acuity and Corneal Biomechanics in Eyes Undergoing Small Incision Lenticule ExtractionJournal of Ophthalmology, 2018
- Refractive Correction and Biomechanical Strength Following SMILE With a 110- or 160-μm Cap Thickness, Evaluated Ex Vivo by Inflation TestInvestigative Ophthalmology & Visual Science, 2018
- In Vivo Early Corneal Biomechanical Changes After Corneal Cross-linking in Patients With Progressive KeratoconusJournal of Refractive Surgery, 2017
- Effect of accelerated corneal crosslinking combined with transepithelial photorefractive keratectomy on dynamic corneal response parameters and biomechanically corrected intraocular pressure measured with a dynamic Scheimpflug analyzer in healthy myopic patientsJournal of Cataract & Refractive Surgery, 2017
- New parameters for evaluating corneal biomechanics and intraocular pressure after small-incision lenticule extraction by Scheimpflug-based dynamic tonometryJournal of Cataract & Refractive Surgery, 2017
- Introduction of Two Novel Stiffness Parameters and Interpretation of Air Puff–Induced Biomechanical Deformation Parameters With a Dynamic Scheimpflug AnalyzerJournal of Refractive Surgery, 2017
- Comparison of 120- and 140-μm SMILE Cap Thickness Results in Eyes With Thick CorneasCornea, 2016
- Comparison of biomechanical effects of small-incision lenticule extraction and laser in situ keratomileusis: Finite-element analysisJournal of Cataract & Refractive Surgery, 2014
- 3D Collagen Orientation Study of the Human Cornea Using X-ray Diffraction and Femtosecond Laser TechnologyInvestigative Ophthalmology & Visual Science, 2009
- Depth-dependent Cohesive Tensile Strength in Human Donor Corneas: Implications for Refractive SurgeryJournal of Refractive Surgery, 2008