YSYosuke Shimazaki

Yosuke Shimazaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yosuke Shimazaki has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Kazuhiro Sawa

    HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)

    5 shared publications
  • Shoji Takada

    HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)

    5 shared publications
  • Masanori Shinohara

    HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)

    4 shared publications
  • Atsushi Shimizu

    Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, 4002 Narita-Cho, Higashi-ibarakigun, Oarai-machi 311-1393, Ibaraki, Japan

    3 shared publications
  • Hiroaki Sawahata

    Japan Atomic Energy Agency, 4002, Narita-cho, Oarai-machi, Higashiibaraki-gun, Ibaraki-ken 311-1393, Japan

    3 shared publications
  • Kazuhiko Iigaki

    Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, 4002 Narita-Cho, Higashi-ibarakigun, Oarai-machi 311-1393, Ibaraki, Japan

    3 shared publications

Latest Publications

  • Comprehensive Seismic Evaluation of HTTR Against the 2011 Off the Pacific Coast of Tohoku Earthquake

    by Masato Ono, Kazuhiko Iigaki, Hiroaki Sawahata, Yosuke Shimazaki, Atsushi Shimizu, Hiroyuki Inoi, Toshinari Kondo, Keidai Kojima, Shoji Takada, Kazuhiro Sawa

    On Mar. 11, 2011, the 2011 off the Pacific coast of Tohoku Earthquake of magnitude 9.0 occurred. When the great earthquake occurred, the high temperature engineering test reactor (HTTR) had been stopped under the periodic inspection and maintenance of equipment and instruments. A comprehensive integrity evaluation was carried out for the HTTR facility because the maximum seismic acceleration observed at the HTTR exceeded the maximum value of design basis earthquake. The concept of comprehensive integrity evaluation is divided into two parts. One is the “visual inspection of equipment and instruments.” The other is the “seismic response analysis” for the building structure, equipment and instruments using the observed earthquake. All equipment and instruments related to operation were inspected in the basic inspection. The integrity of the facilities was confirmed by comparing the inspection results or the numerical results with their evaluation criteria. As the results of inspection of equipment and instruments associated with the seismic response analysis, it was judged that there was no problem for operation of the reactor, because there was no damage and performance deterioration. The integrity of HTTR was also supported by the several operations without reactor power in cold conditions of HTTR in 2011, 2013, and 2015. Additionally, the integrity of control rod guide blocks was also confirmed visually when three control rod guide blocks and six replaceable reflector blocks were taken out from reactor core in order to change neutron startup sources in 2015.


  • Improvement of neutron startup source handling work by developing new transportation container for high-temperature engineering test reactor (HTTR)

    by Yosuke Shimazaki, Hiroaki Sawahata, Masanori Shinohara, Yoshinori Yanagida, Taiki Kawamoto, Shoji Takada

    The high-temperature engineering test reactor (HTTR) has three neutron startup sources (NSs) in the reactor core, each of which consists of 252Cf with 3.7 GBq, installed in NS holder and subsequently in a control rod guide block (CR block). The NSs are exchanged at the interval of approximately seven years. The NS holders are transported from the dealer's hot cell to the HTTR using a transportation container. The loading work of NS holders to the CR blocks is subsequently carried out in the fuel handling machine maintenance pit of HTTR. Technical issues, which are the reduction and prevention of radiation exposure of workers and the exclusion of falling of NS holder, were extracted from the experiences in the past two exchange works of NSs to develop a safety handling procedure. Then, a new transportation container special to the NSs of HTTR was developed to solve the technical issues while keeping the cost as low as that for overhaul of conventional container. As a result, the NS handling work using the new transportation container was safely accomplished by developing the new transportation container which can reduce the risks of radiation exposure dose of workers and exclude the falling of NS holder.


  • Investigation of Countermeasure Against Local Temperature Rise in Vessel Cooling System in Loss of Core Cooling Test Without Nuclear Heating

    by Masato Ono, Atsushi Shimizu, Makoto Kondo, Yosuke Shimazaki, Masanori Shinohara, Daisuke Tochio, Kazuhiko Iigaki, Shigeaki Nakagawa, Shoji Takada, Kazuhiro Sawa

    In the loss of core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of the reactor core is stopped without inserting control rods into the core and, furthermore, without cooling by the vessel cooling system (VCS) to verify safety evaluation codes to investigate the inherent safety of high-temperature gas-cooled reactor (HTGR) be secured by natural phenomena to make it possible to design a severe accident-free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel (RPV) by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water-cooling tube without thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from helium gas circulators (HGCs) by stopping water flow in the VCS, the local higher temperature position was specified in the uncovered water-cooling tube of the VCS, although the temperature was sufficiently lower than the maximum allowable working temperature, and the natural circulation of water had an insufficient cooling effect on the temperature of the water-cooling tube below 1°C. Then, a new safe and secured procedure for the loss of core cooling test was established, which will be carried out soon after the restart of HTTR.

  • Development of the Prediction Technology of Cable Disconnection of In-Core Neutron Detector for the Future High-Temperature Gas-Cooled Reactors

    by Yosuke Shimazaki, Hiroaki Sawahata, Taiki Kawamoto, Hisashi Suzuki, Masanori Shinohara, Yuki Honda, Kozo Katsuyama, Shoji Takada, Kazuhiro Sawa

    Maintenance technologies for the reactor system have been developed by using the High Temperature engineering Test Reactor (HTTR). One of the important purposes of development is to accumulate the experiences and data to satisfy the availability of operation up to 90% by shortening the duration of the periodical maintenance for future high-temperature gas-cooled reactors (HTGRs) by shifting from time-based maintenance to condition-based maintenance. The technical issue of the maintenance of the in-core neutron detector, wide range monitor (WRM), is to predict the malfunction caused by cable disconnection to plan the replacement schedule. This is because it is difficult to observe directly inside the WRM in detail. The electrical inspection method was proposed to detect and predict the cable disconnection of the WRM by remote monitoring from outside the reactor using the time-domain reflectometry (TDR). The disconnection position, which was specified by the electrical method, was identified by nondestructive and destructive inspection. The accumulated data are expected to be contributed for advanced maintenance of future HTGRs.

  • ICONE23-1636 Investigation of Characteristics of Natural Circulation of Water in Vessel Cooling System in Loss of Core Cooling Test without Nuclear Heating

    by Shoji Takada, Atsushi Shimizu, Makoto Kondo, Yosuke Shimazaki, Masanori Shinohara, Tomokazu Seki, Daisuke Tochio, Kazuhiko Iigaki, Shigeaki Nakagawa, Kazuhiro Sawa

    In the loss of forced core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of reactor core is stopped without inserting control rods into the core and cooling by Vessel Cooling System (VCS) to demonstrate the inherent safety of HTGR be secured by natural phenomena to make it possible to design a severe accident free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water cooling tube by thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from gas circulators with stopping water flow in the VCS, the local higher temperature position was specified although the temperature was sufficiently lower than the maximum allowable working temperature, and natural circulation of water had insufficient cooling effect on the temperature of water cooling tube below 1℃. Then, a new safe and secured procedure for the loss of forced core cooling test was established, which will be carried out soon after the restart of HTTR.

  • ICONE23-1670 DEVELOPMENT OF THE PREDICTION TECHNOLOGY OF CABLE DISCONNECTION OF IN-CORE NEUTRON DETECTOR FOR THE FUTURE HIGH-TEMPERATURE GAS COOLED REACTORS

    by Yosuke Shimazaki, Hiroaki Sawahata, Taiki Kawamoto, Hisashi Suzuki, Masanori Shinohara, Yuki Honda, Kozo Katsuyama, Shoji Takada, Kazuhiro Sawa

    Maintenance technologies for the reactor system have been developed by using the high-temperature engineering test reactor (HTTR). One of the important purposes of development is to accumulate the experiences and data to satisfy the availability of operation up to 90% by shortening the duration of the periodical maintenance for the future HTGRs by shifting from the time-based maintenance to condition-based maintenance. The technical issue of the maintenance of in-core neutron detector, wide range monitor (WRM), is to predict the malfunction caused by cable disconnection to plan the replacement schedule. This is because that it is difficult to observe directly inside of the WRM in detail. The electrical inspection method was proposed to detect and predict the cable disconnection of the WRM by remote monitoring from outside of the reactor by using the time domain reflectometry and so on. The disconnection position, which was specified by the electrical method, was identified by non-destructive and destructive inspection. The accumulated data is expected to be contributed for advanced maintenance of future HTGRs.

  • Dust Generation and Transport Behavior in the Primary Circuit of HTTR

    by Shimpei Hamamoto, Yosuke Shimazaki, Takayuki Furusawa, Takahiro Nemoto, Hiroyuki Inoi

    Dust is to be limited in the primary circuit of the high temperature gas-cooled reactors (HTGRs) with regard to the reactor operational stability and structural integrity of the heat exchanger because the dust in the coolant adheres to the heat transfer pipe surface, and it is lowered with the performance of the heat exchanger. Furthermore, the dust, including the fission products (FPs) which adhered to the piping, must be reduced in order to be discharged in the depressurization accident with coolant helium.In High Temperature Engineering Test Reactor (HTTR), the rise of filter differential pressure of primary helium gas circulator (HGC) showed that the dust was arising in the coolant. The increase of differential pressure at the filter of the HGC for the primary pressurized water cooler (PPWC) in HTTR was observed from the beginning of the HGC operation. The differential pressure rose with the increase in operating time of the HGC, and the filter had to be exchanged the filter approximately in about every 8400 hours.Therefore, the source of the dust should be investigated using The Scanning Electron Microscope (SEM) and The X-ray Fluorescence (XRF) analyzer. SEM was used to observe the appearance of the captured dust in detail and to identify its shape and its size. This result clearly indicated that the dusts mainly composed of carbon. XRF was used to estimate the sources of the carbonaceous dust particles. It was clarified that the source of dust is the slide member of the compressor which is not of a primary cooling system.Copyright © 2012 by ASME