KIKazuhiko Iigaki

Kazuhiko Iigaki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kazuhiko Iigaki has a total of 14 co-authors. Here are the top co-authors by number of shared publications:

  • Atsushi Shimizu

    Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, 4002 Narita-Cho, Higashi-ibarakigun, Oarai-machi 311-1393, Ibaraki, Japan

    3 shared publications
  • Kazuhiro Sawa

    HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)

    3 shared publications
  • Shoji Takada

    HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)

    3 shared publications
  • Yosuke Shimazaki

    HTTR Reactor Engineering Section Department of HTTR Oarai Research and Development Center Sector of Nuclear Science Research Japan Atomic Energy Agency (JAEA)

    3 shared publications
  • Daisuke Tochio

    HTTR Reactor Engineering Section, Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, Higashi-ibaraki-gun, Oarai 311-1393, Ibaraki, Japan

    2 shared publications
  • Makoto Kondo

    Department of HTTR, Oarai Research and Development Center, Sector of Nuclear Science Research, Japan Atomic Energy Agency, 4002 Narita-Cho, Oarai-machi, Higashi-ibarakigun, Ibaraki 311-1393, Japan

    2 shared publications

Latest Publications

  • Comprehensive Seismic Evaluation of HTTR Against the 2011 Off the Pacific Coast of Tohoku Earthquake

    by Masato Ono, Kazuhiko Iigaki, Hiroaki Sawahata, Yosuke Shimazaki, Atsushi Shimizu, Hiroyuki Inoi, Toshinari Kondo, Keidai Kojima, Shoji Takada, Kazuhiro Sawa

    On Mar. 11, 2011, the 2011 off the Pacific coast of Tohoku Earthquake of magnitude 9.0 occurred. When the great earthquake occurred, the high temperature engineering test reactor (HTTR) had been stopped under the periodic inspection and maintenance of equipment and instruments. A comprehensive integrity evaluation was carried out for the HTTR facility because the maximum seismic acceleration observed at the HTTR exceeded the maximum value of design basis earthquake. The concept of comprehensive integrity evaluation is divided into two parts. One is the “visual inspection of equipment and instruments.” The other is the “seismic response analysis” for the building structure, equipment and instruments using the observed earthquake. All equipment and instruments related to operation were inspected in the basic inspection. The integrity of the facilities was confirmed by comparing the inspection results or the numerical results with their evaluation criteria. As the results of inspection of equipment and instruments associated with the seismic response analysis, it was judged that there was no problem for operation of the reactor, because there was no damage and performance deterioration. The integrity of HTTR was also supported by the several operations without reactor power in cold conditions of HTTR in 2011, 2013, and 2015. Additionally, the integrity of control rod guide blocks was also confirmed visually when three control rod guide blocks and six replaceable reflector blocks were taken out from reactor core in order to change neutron startup sources in 2015.


  • Investigation of Countermeasure Against Local Temperature Rise in Vessel Cooling System in Loss of Core Cooling Test Without Nuclear Heating

    by Masato Ono, Atsushi Shimizu, Makoto Kondo, Yosuke Shimazaki, Masanori Shinohara, Daisuke Tochio, Kazuhiko Iigaki, Shigeaki Nakagawa, Shoji Takada, Kazuhiro Sawa

    In the loss of core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of the reactor core is stopped without inserting control rods into the core and, furthermore, without cooling by the vessel cooling system (VCS) to verify safety evaluation codes to investigate the inherent safety of high-temperature gas-cooled reactor (HTGR) be secured by natural phenomena to make it possible to design a severe accident-free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel (RPV) by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water-cooling tube without thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from helium gas circulators (HGCs) by stopping water flow in the VCS, the local higher temperature position was specified in the uncovered water-cooling tube of the VCS, although the temperature was sufficiently lower than the maximum allowable working temperature, and the natural circulation of water had an insufficient cooling effect on the temperature of the water-cooling tube below 1°C. Then, a new safe and secured procedure for the loss of core cooling test was established, which will be carried out soon after the restart of HTTR.

  • ICONE23-1636 Investigation of Characteristics of Natural Circulation of Water in Vessel Cooling System in Loss of Core Cooling Test without Nuclear Heating

    by Shoji Takada, Atsushi Shimizu, Makoto Kondo, Yosuke Shimazaki, Masanori Shinohara, Tomokazu Seki, Daisuke Tochio, Kazuhiko Iigaki, Shigeaki Nakagawa, Kazuhiro Sawa

    In the loss of forced core cooling test using High Temperature engineering Test Reactor (HTTR), the forced cooling of reactor core is stopped without inserting control rods into the core and cooling by Vessel Cooling System (VCS) to demonstrate the inherent safety of HTGR be secured by natural phenomena to make it possible to design a severe accident free reactor. The VCS passively removes the retained residual heat and the decay heat from the core via the reactor pressure vessel by natural convection and thermal radiation. In the test, the local temperature was supposed to exceed the limit from the viewpoint of long-term use at the uncovered water cooling tube by thermal reflectors in the VCS, although the safety of reactor is kept. Through a cold test, which was carried out by non-nuclear heat input from gas circulators with stopping water flow in the VCS, the local higher temperature position was specified although the temperature was sufficiently lower than the maximum allowable working temperature, and natural circulation of water had insufficient cooling effect on the temperature of water cooling tube below 1℃. Then, a new safe and secured procedure for the loss of forced core cooling test was established, which will be carried out soon after the restart of HTTR.