Tadeo Vitko
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Tadeo Vitko has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Jay Witherspoon
CH2M 6 Hutton Center Drive, Suite 700, Santa Ana, CA 92707
4 shared publicationsZeynep Erdal
CH2M 6 Hutton Center Drive, Suite 700, Santa Ana, CA 92707
4 shared publications- Irwin H. Suffet
Department of Environmental Health Science, UCLA, School of Public Health, Los Angeles, CA 90095, USA
3 shared publications Scott Cowden
CH2M 1100 NE Circle Blvd. Suite 300, Corvallis, OR 97330
3 shared publications- Yubin Zhou
UCLA Department of Environmental Health Sciences, School of Public Health, Los Angeles, CA 90095
3 shared publications Carla Dillon
Orange County Sanitation District, 10844 Ellis Ave., Fountain Valley, CA 92708
2 shared publications
Latest Publications
- 1 January 2018
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2018 (2) , 298-327
Multiple Technology Pilot Testing Supports Selection of Targeted Foul Air Treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan (OCMP) from a unique and innovative perspective. In lieu of the...
- 1 January 2018
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2018 (2) , 298-327
Multiple Technology Pilot Testing Supports Selection of Targeted Foul Air Treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan (OCMP) from a unique and innovative perspective. In lieu of the...
- 1 January 2017
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2017 (16) , 358-378
Odor control masterplanning using real life data and tailored tools allows development of strategic plan compliance roadmap
Cognizant that odors are caused by various compounds besides hydrogen sulfide (H2S), Orange County Sanitation District (OCSD) embarked on a detailed...
- 1 January 2017
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2017 (16) , 358-378
Odor control masterplanning using real life data and tailored tools allows development of strategic plan compliance roadmap
Cognizant that odors are caused by various compounds besides hydrogen sulfide (H2S), Orange County Sanitation District (OCSD) embarked on a detailed...
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 394-409
How Does Dynamic Olfactometry Really Work?
An odor sample is represented by individual odors, which change when subjected to dilution. Olfactometry by dilution of the odorants cause some odors to remain undetected. Odors initially prominent lose intensity as their Concentration to Odor Threshold Concentration (C/OTC) decrease. At greater dilutions, odorants with high C/OTC (e.g. musty odors) that are masked by the prominent odorants (e.g. fecal and sulfur odors) appear. The OTC of nine “most detectable” odorants at two Wastewater Treatment Plants were determined based on Weber-Fechner curves, using the Odor Profile Method and dynamic olfactometry. Two odor panel methods were compared, olfactometry with the traditional dilution to threshold (D/T), and the Odor Profile Method (OPM) to show advantages and disadvantages for their use for determining OTCs, odors, the “peeling the onion” effect, and the evaluation of odor abatement strategies. Using the olfactometry D/T ratio alone does not allow investigation of the specific on-site and off-site odorant nuisances in mixtures because the method does not indicate the fate of mixed odorants. The OPM is able to determine the change of major odors during dilution and shows how the “peeling of the onion” effect occurs with dilution. The OPM can be used to evaluate odor treatment technologies.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 394-409
How Does Dynamic Olfactometry Really Work?
An odor sample is represented by individual odors, which change when subjected to dilution. Olfactometry by dilution of the odorants cause some odors to remain undetected. Odors initially prominent lose intensity as their Concentration to Odor Threshold Concentration (C/OTC) decrease. At greater dilutions, odorants with high C/OTC (e.g. musty odors) that are masked by the prominent odorants (e.g. fecal and sulfur odors) appear. The OTC of nine “most detectable” odorants at two Wastewater Treatment Plants were determined based on Weber-Fechner curves, using the Odor Profile Method and dynamic olfactometry. Two odor panel methods were compared, olfactometry with the traditional dilution to threshold (D/T), and the Odor Profile Method (OPM) to show advantages and disadvantages for their use for determining OTCs, odors, the “peeling the onion” effect, and the evaluation of odor abatement strategies. Using the olfactometry D/T ratio alone does not allow investigation of the specific on-site and off-site odorant nuisances in mixtures because the method does not indicate the fate of mixed odorants. The OPM is able to determine the change of major odors during dilution and shows how the “peeling of the onion” effect occurs with dilution. The OPM can be used to evaluate odor treatment technologies.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 659-671
How OCSD Identified the Most Detectable Odorants
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan from a different view point than usual. Cognizant that odors are caused by compounds besides hydrogen sulfide, it embarked on a wide sweep of sampling and analysis of all plant process areas to determine the top offenders. In that effort, analytical and sensorial methodologies were used, generating a large number of results. This paper discusses the procedure OCSD uses to determine what odorants are “most detectable” among the large number of results obtained.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 659-671
How OCSD Identified the Most Detectable Odorants
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan from a different view point than usual. Cognizant that odors are caused by compounds besides hydrogen sulfide, it embarked on a wide sweep of sampling and analysis of all plant process areas to determine the top offenders. In that effort, analytical and sensorial methodologies were used, generating a large number of results. This paper discusses the procedure OCSD uses to determine what odorants are “most detectable” among the large number of results obtained.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 506-525
Innovative odor mapping and management method sets the stage for targetted foul air treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan from a different view point than usual. Cognizant that odors are caused by compounds besides hydrogen sulfide (H2S), it embarked on a wide sweep of sampling and analysis of all plant process areas to determine the top offenders at its Plant No.1 and Plant No.2 located in coastal Southern California, neighboring a densely populated sensitive residential and commercial community. As part of the characterization of the key odorants present in the various process areas of the two plants, field samples were analyzed using chemical and sensory analytical methods. Top odorants were identified based on their prevailing concentrations, sensory response, and relative intensities at each location. Once the top odorants were identified at each of the plant process areas, these were repetitively monitored to improve result precision. Results were also matched with continuous monitors and operational variables to ascertain worst-case scenario concentrations. Using the Weber-Fechner relationship between each odorant concentration and their perceived intensity, the maximum fenceline concentrations below nuisance were determined. Local worse-case air dispersion modeling using AERMOD and CALPUFF are being used in developing target odorant concentrations at each source at Plant 1 and Plant 2 for meeting maximum fenceline concentration goals. This innovative approach to odor characterization/mapping is also coupled with a thorough odorant treatment technologies assessment. A comprehensive literature search has been conducted to ascertain both practical and theoretical odorant removal efficiencies for all viable technologies. This will be followed by specific technology testing for determination of removal efficiencies and performance targets for selected technologies in their ability to reduce the identified top odorants identified at OCSD. The target source concentration for each of the top odorants identified considering both treatment performance testing and air dispersion modeling sets the design parameters for the proposed foul air treatment systems for implementation at OCSD plant processes.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (2) , 506-525
Innovative odor mapping and management method sets the stage for targetted foul air treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan from a different view point than usual. Cognizant that odors are caused by compounds besides hydrogen sulfide (H2S), it embarked on a wide sweep of sampling and analysis of all plant process areas to determine the top offenders at its Plant No.1 and Plant No.2 located in coastal Southern California, neighboring a densely populated sensitive residential and commercial community. As part of the characterization of the key odorants present in the various process areas of the two plants, field samples were analyzed using chemical and sensory analytical methods. Top odorants were identified based on their prevailing concentrations, sensory response, and relative intensities at each location. Once the top odorants were identified at each of the plant process areas, these were repetitively monitored to improve result precision. Results were also matched with continuous monitors and operational variables to ascertain worst-case scenario concentrations. Using the Weber-Fechner relationship between each odorant concentration and their perceived intensity, the maximum fenceline concentrations below nuisance were determined. Local worse-case air dispersion modeling using AERMOD and CALPUFF are being used in developing target odorant concentrations at each source at Plant 1 and Plant 2 for meeting maximum fenceline concentration goals. This innovative approach to odor characterization/mapping is also coupled with a thorough odorant treatment technologies assessment. A comprehensive literature search has been conducted to ascertain both practical and theoretical odorant removal efficiencies for all viable technologies. This will be followed by specific technology testing for determination of removal efficiencies and performance targets for selected technologies in their ability to reduce the identified top odorants identified at OCSD. The target source concentration for each of the top odorants identified considering both treatment performance testing and air dispersion modeling sets the design parameters for the proposed foul air treatment systems for implementation at OCSD plant processes.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (9) , 1458-1477
Innovative Odor Mapping and Management Method Sets the Stage for Targetted Foul Air Treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan from a different view point than usual. Cognizant that odors are caused by compounds besides hydrogen sulfide (H2S), it embarked on a wide sweep of sampling and analysis of all plant process areas to determine the top offenders at its Plant No.1 and Plant No.2 located in coastal Southern California, neighboring a densely populated sensitive residential and commercial community. As part of the characterization of the key odorants present in the various process areas of the two plants, field samples were analyzed using chemical and sensory analytical methods. Top odorants were identified based on their prevailing concentrations, sensory response, and relative intensities at each location. Once the top odorants were identified at each of the plant process areas, these were repetitively monitored to improve result precision. Results were also matched with continuous monitors and operational variables to ascertain worst-case scenario concentrations. Using the Weber-Fechner relationship between each odorant concentration and their perceived intensity, the maximum fenceline concentrations below nuisance were determined. Local worse-case air dispersion modeling using AERMOD and CALPUFF are being used in developing target odorant concentrations at each source at Plant 1 and Plant 2 for meeting maximum fenceline concentration goals. This innovative approach to odor characterization/mapping is also coupled with a thorough odorant treatment technologies assessment. A comprehensive literature search has been conducted to ascertain both practical and theoretical odorant removal efficiencies for all viable technologies. This will be followed by specific technology testing for determination of removal efficiencies and performance targets for selected technologies in their ability to reduce the identified top odorants identified at OCSD. The target source concentration for each of the top odorants identified considering both treatment performance testing and air dispersion modeling sets the design parameters for the proposed foul air treatment systems for implementation at OCSD plant processes.
- 1 January 2016
- Published by Water Environment Federation in Proceedings of the Water Environment Federation
- Vol. 2016 (9) , 1458-1477
Innovative Odor Mapping and Management Method Sets the Stage for Targetted Foul Air Treatment
The Orange County Sanitation District (OCSD) approached its Odor Control Master Plan from a different view point than usual. Cognizant that odors are caused by compounds besides hydrogen sulfide (H2S), it embarked on a wide sweep of sampling and analysis of all plant process areas to determine the top offenders at its Plant No.1 and Plant No.2 located in coastal Southern California, neighboring a densely populated sensitive residential and commercial community. As part of the characterization of the key odorants present in the various process areas of the two plants, field samples were analyzed using chemical and sensory analytical methods. Top odorants were identified based on their prevailing concentrations, sensory response, and relative intensities at each location. Once the top odorants were identified at each of the plant process areas, these were repetitively monitored to improve result precision. Results were also matched with continuous monitors and operational variables to ascertain worst-case scenario concentrations. Using the Weber-Fechner relationship between each odorant concentration and their perceived intensity, the maximum fenceline concentrations below nuisance were determined. Local worse-case air dispersion modeling using AERMOD and CALPUFF are being used in developing target odorant concentrations at each source at Plant 1 and Plant 2 for meeting maximum fenceline concentration goals. This innovative approach to odor characterization/mapping is also coupled with a thorough odorant treatment technologies assessment. A comprehensive literature search has been conducted to ascertain both practical and theoretical odorant removal efficiencies for all viable technologies. This will be followed by specific technology testing for determination of removal efficiencies and performance targets for selected technologies in their ability to reduce the identified top odorants identified at OCSD. The target source concentration for each of the top odorants identified considering both treatment performance testing and air dispersion modeling sets the design parameters for the proposed foul air treatment systems for implementation at OCSD plant processes.