MSMadappa V. R. Sivasubramanian

Madappa V. R. Sivasubramanian

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Madappa V. R. Sivasubramanian has a total of 35 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Bending Performance and Evaluation of Tensile Properties of Polyester Fiber Reinforced Ductile Fiber Reinforced Cementitious Composite (PES-DFRCC)

    by Madappa Vr Sivasubramanian, Shoya Furukawa, Helen Negash Shiferaw, K Hamsavathi, Toshiyuki Kanakubo, Shamsher Bahadur Singh

    Introduction/Objective: This study investigates the flexural and equivalent tensile behaviour of polyester fiber-reinforced ductile fiber-reinforced cementitious composite (PES-DFRCC) incorporating commercially available Indian-manufactured polyester fibers. The influence of fiber volume fraction on the flexural response and equivalent tensile properties was evaluated through four-point bending tests and inverse section analysis. This study presents the first experimental investigation of PES-DFRCC using this methodology and establishes its equivalent tensile stress–strain behaviour. Methods: Beam specimens containing different polyester fiber volume fractions were tested under four-point bending in accordance with ISO 21914:2019. Load, axial deformation, and deflection measurements were recorded, and tensile properties were determined through inverse section analysis based on the observed flexural response. Results: The PES-DFRCC specimens exhibited multiple microcracking and pronounced deflection-hardening behavior under bending. The evaluated average tensile strength ranged from 0.34 to 2.41 MPa, while the corresponding average ultimate tensile strain varied from 0.276% to 0.450%, depending on the fiber content. Discussion: The formation of multiple microcracks contributed to enhanced ductility and energy absorption capacity, indicating the effectiveness of polyester fibers in improving the post-cracking performance of cementitious composites. Conclusion: The newly developed PES-DFRCC demonstrated significant ductile behavior, characterized by multiple cracking, deflection hardening, and improved tensile performance. These findings highlight the potential of polyester fiber reinforcement for developing durable and ductile cementitious materials for structural applications.

  • Open Access

    A sensor selection framework for vibration based structural health monitoring of civil infrastructure

    by D. Kesavan Periyasamy, Madappa V. R. Sivasubramanian

  • Open Access

    Performance and capacity assessment of RC beams reinforced with Recycled GFRP bars extracted from wind turbine blades under flexural loading

    by Madappa Vr Sivasubramanian, Arulkumaran S, Arthi S

    The rapid expansion of the wind energy sector has resulted in a growing volume of end-of-life wind turbine blades, posing significant challenges for the sustainable management of glass fibre reinforced polymer (GFRP) composite waste. This study examines the effectiveness of utilizing GFRP bars extracted from wind turbine blades as tensile reinforcement in reinforced concrete (RC) beams. Four RC beam specimens with varying reinforcement ratios of extracted GFRP bars were experimentally evaluated under four-point bending to examine their failure modes,load–deflection,stiffness and energy absorption characteristics.The experimental results indicated that the ultimate load carrying capacity ranged from 85.95kN to 118.7kN, with B3 exhibiting a lower load capacity than B2 despite a higher reinforcement ratio,owing to the lower elastic modulus of the GFRP bars and concrete crushing prior to full mobilization of the reinforcement tensile capacity. The observed failure modes included GFRP rupture,flexure–compression failure,and premature shear failure. FEA performed using ABAQUS accurately captured the performance of the tested beams. Analytical results based on ACI440.1R compared with the experimental results, yielding experimental-to-analytical load ratios between from 1.17 to 1.49. The findings demonstrated that structural behaviour of recycled GFRP-RC beams is governed by both reinforcement ratio and reinforcement stiffness,highlighting the importance of considering elastic modulus in design. Although the findings support the sustainable reuse of decommissioned wind turbine blade composites as reinforcement in RC members, the study is limited to short-span beam specimens, and further investigations on larger-span members and detailed material characterization are recommended to fully assess the long-term structural performance of recycled GFRP reinforcement.

  • Open Access

    Load Capacity Evaluation of ECC and GFRP Strengthened RC Beams Under Combined Bending and Shear

    by Jagadesh Kannan Selvan, Preethy Mary Arulanandam, Sherine Stanly, Madappa V. R. Sivasubramanian

    This study presents a mechanics based analytical framework for predicting the flexural–shear capacity of reinforced concrete (RC) beams strengthened with Engineered Cementitious Composites (ECCs) and a hybrid ECC–GFRP near surface mounted (NSM) system. Building upon previously reported experimental observations, the present work aims to establish rational prediction models capable of capturing the interaction between flexural and shear mechanisms in strengthened beams. The analytical approach integrates sectional analysis for flexural capacity with a modified truss analogy for shear resistance, explicitly incorporating the strain hardening tensile contribution of ECC and the tensile and confinement effects of GFRP reinforcement. An interaction based failure criterion is subsequently employed to identify the governing failure mode under combined flexural shear actions. The proposed model is validated against experimental results obtained from twenty seven beam specimens with varying flexural and shear reinforcement ratios and strengthening configurations. The predicted ultimate loads show good agreement with experimental values, with an average deviation within ±10%. The analytical framework accurately captures the transition between flexural dominated, combined flexural–shear, and diagonal tension failures observed experimentally. Results demonstrate that ECC significantly enhances ductility and shear crack control, while the hybrid ECC–GFRP system provides substantial strength enhancement with a controlled shift in failure mode. Overall, the developed analytical models offer a reliable and computationally efficient tool for predicting the flexural–shear capacity and failure behavior of ECC and hybrid ECC–GFRP-strengthened RC beams, supporting performance based design and practical strengthening applications.


  • Assessing Seismic Risks in Heritage Slender Masonry Minaret: A Case Study of Chand Minar

    by K. Manikandan, M. Nidhi, Francesco Micelli, Alessio Cascardi, Madappa V. R. Sivasubramanian

  • Open Access

    Mechanical, Degradation, and Impact Resistance of a Sustainable Coir Geotextile Composite Barrier for Landslide Mitigation

    by Harshith Nelson, Senthilkumar Vadivel, Madappa V. R. Sivasubramanian, Sathish Kumar Veerappan

    Flexible barrier systems are widely used for landslide and debris flow mitigation due to their ability to dissipate impact energy through large deformations. Conventional systems, however, rely on steel mesh components, which are associated with high environmental impact and durability concerns. This study examines the feasibility of a sustainable coir geotextile composite barrier as an alternative flexible barrier for mitigating small-to-moderate landslides. A woven geotextile barrier was developed using multi-strand coir ropes and evaluated through a comprehensive experimental program involving physical and mechanical characterization, accelerated degradation testing, incremental static loading, vertical drop impact tests, and sustained load retention tests. The developed barrier exhibited a high mass per unit area of approximately 3750 g/m2 and tensile capacities exceeding 2 kN at the rope level. Accelerated weathering tests revealed a limited reduction in tensile strength of approximately 5% after three years of exposure, whereas prolonged exposure of five years led to strength losses exceeding 70%, underscoring durability as a key design consideration. Static loading tests confirmed stable behavior up to 550 kg, and sustained loading of approximately 1700 kg was maintained over 48 h without loss of structural integrity. Vertical drop tests demonstrated impact resistance in the range of 6–51 kN, depending on the drop height, mass, and connection density. The results demonstrate that coir geotextile barriers can function as flexible, energy-dissipating composite systems suitable for sustainable landslide mitigation in moderate hazard scenarios.


  • Evaluation of Tensile Stress and Strain Capacity Using UM Method

    by Preethy Mary Arulanandam, S. B. Singh, Madappa V. R. Sivasubramanian

  • Shear Strength Prediction of Reinforced Concrete Beams Using Truss Analogy Approach

    by Sherine Stanly, Madappa V. R. Sivasubramanian, Shamsher Bahadur Singh