Alexander Stanitzki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexander Stanitzki has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Michael Görtz
Fraunhofer Institute for Microelectronic Circuits and Systems IMS , 47057 Duisburg , Germany
3 shared publications - Jens Weidenmüller
28462 Fraunhofer-Institut für Mikroelektronische Schaltungen und Systeme , Abteilung TSA , Finkenstr. 61 , Duisburg Germany
2 shared publications - Mario Baum
Fraunhofer Institute for Electronic Nano Systems ENAS , 09126 Chemnitz , Germany
2 shared publications - Oezgue Dogan
Fraunhofer Institute for Microelectronic Circuits and Systems, 47057 Duisburg, Germany
2 shared publications - Alexander Utz
Faculty of Information, Media and Electrical Engineering, Institute of Applied Optics and Electronics, Kln, Germany
1 shared publication - Andre Lüdecke
Fraunhofer Institute for Microelectronic Circuits and Systems, 47057 Duisburg, Germany
1 shared publication
Latest Publications
- Open Access
A New Configurable Wireless Sensor System for Biomedical Applications with ISO 18000-3 Interface in 0.35 µm CMOS
This article presents a new configurable wireless sensor system. The system is used to perform amperometric measurements and send the measurement data to a handheld reader using a wireless transponder interface. The two-chip sensor system was implemented in a 0.35 μm CMOS technology. The system consists of an integrated nano-potentiostat that performs the actual measurements and an ISO 18000-3 compliant frontend that enables wireless telemetric data transmission and powering of the entire sensor system. The system was manufactured in combination with a chronoamperometric glucose sensor which allows the measurement of the glucose content in tear fluid and thus a non-invasive determination of the blood sugar level. For a range of sensor currents from 0.1 μA to 10 μA, the potentiostat achieved an accuracy of better than 5 % with a total power dissipation of less than 600 μW. With the realized antenna geometry a wireless communication distance of more than 7 cm has been achieved.
Open AccessA New Configurable Wireless Sensor System for Biomedical Applications with ISO 18000-3 Interface in 0.35 µm CMOS
This article presents a new configurable wireless sensor system. The system is used to perform amperometric measurements and send the measurement data to a handheld reader using a wireless transponder interface. The two-chip sensor system was implemented in a 0.35 μm CMOS technology. The system consists of an integrated nano-potentiostat that performs the actual measurements and an ISO 18000-3 compliant frontend that enables wireless telemetric data transmission and powering of the entire sensor system. The system was manufactured in combination with a chronoamperometric glucose sensor which allows the measurement of the glucose content in tear fluid and thus a non-invasive determination of the blood sugar level. For a range of sensor currents from 0.1 μA to 10 μA, the potentiostat achieved an accuracy of better than 5 % with a total power dissipation of less than 600 μW. With the realized antenna geometry a wireless communication distance of more than 7 cm has been achieved.
- 1 April 2018
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 85 (5) , 359-365
Implantable multi-sensor system for hemodynamic controlling
A miniaturized implantable multi-sensor system for cardiovascular monitoring of physiological parameters is presented. High accuracy pressure measurements within the vessel can be performed by a capacitive pressure sensor. Additional information about the patient, e.g., sudden movement, inclination or increased temperature can be obtained by additional sensor components such as an acceleration sensor and a temperature sensor unit. This information facilitates compensation of interferences for more accurate pressure measurements. A multifunctional ASIC enables, amongst others, sensor signal processing, power management and telemetric communication with extracorporeal electronics. Sensor chips, the multi-functional ASIC and passive components are assembled on a LTCC circuit board in which an antenna coil is integrated for telemetric energy and data transmission at a frequency of 13.56 MHz. In order to support further miniaturization, the implant shall be encapsulated with a stack of very thin and hermetic ceramics applied by ALD instead of using bulky metal housings. Further encapsulation with polymers, which can be functionalised with appropriate biomolecules, is necessary for a proper shape, a biocompatible interface to the surrounding tissue and, thereby, reduction of thrombogenicity.
- 1 April 2018
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 85 (5) , 359-365
Implantable multi-sensor system for hemodynamic controlling
A miniaturized implantable multi-sensor system for cardiovascular monitoring of physiological parameters is presented. High accuracy pressure measurements within the vessel can be performed by a capacitive pressure sensor. Additional information about the patient, e.g., sudden movement, inclination or increased temperature can be obtained by additional sensor components such as an acceleration sensor and a temperature sensor unit. This information facilitates compensation of interferences for more accurate pressure measurements. A multifunctional ASIC enables, amongst others, sensor signal processing, power management and telemetric communication with extracorporeal electronics. Sensor chips, the multi-functional ASIC and passive components are assembled on a LTCC circuit board in which an antenna coil is integrated for telemetric energy and data transmission at a frequency of 13.56 MHz. In order to support further miniaturization, the implant shall be encapsulated with a stack of very thin and hermetic ceramics applied by ALD instead of using bulky metal housings. Further encapsulation with polymers, which can be functionalised with appropriate biomolecules, is necessary for a proper shape, a biocompatible interface to the surrounding tissue and, thereby, reduction of thrombogenicity.
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s37-s39
Session 10. Medical measuring techniques I
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s37-s39
Session 10. Medical measuring techniques I
- 20 December 2016
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 84 (1) , 53-58
Telemetric multi-sensor system for medical applications – The approach
Long-term monitoring of hemodynamics can be achieved by an implantable and telemetric multi-sensor system. A concept to realize a system with high miniaturization level is presented. The requirements regarding a multifunctional transponder ASIC (application specific integrated circuit), which should combine signal processing, telemetric communication and additional sensors in one chip, are introduced. Capacitive pressure sensors showing low power consumption were tested with laboratory setups with respect to the integration in this concept. First results were achieved and discussed concerning two potential assembly technologies for the integration of a pressure sensor. Finally, hermetic sealing and implant encapsulation technologies are proposed for further implant miniaturization.
- 20 December 2016
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 84 (1) , 53-58
Telemetric multi-sensor system for medical applications – The approach
Long-term monitoring of hemodynamics can be achieved by an implantable and telemetric multi-sensor system. A concept to realize a system with high miniaturization level is presented. The requirements regarding a multifunctional transponder ASIC (application specific integrated circuit), which should combine signal processing, telemetric communication and additional sensors in one chip, are introduced. Capacitive pressure sensors showing low power consumption were tested with laboratory setups with respect to the integration in this concept. First results were achieved and discussed concerning two potential assembly technologies for the integration of a pressure sensor. Finally, hermetic sealing and implant encapsulation technologies are proposed for further implant miniaturization.