Jens Weidenmüller
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jens Weidenmüller has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Michael Görtz
Fraunhofer Institute for Microelectronic Circuits and Systems IMS , 47057 Duisburg , Germany
3 shared publications - Alexander Stanitzki
Fraunhofer IMS, 47057 Duisburg, Germany
2 shared publications - Anton Grabmaier
Fraunhofer Institute for Microelectronic Circuits and Systems, 47057 Duisburg, Germany
1 shared publication Christian Walk
Fraunhofer Institute for Microelectronic Circiuts and Systems IMS, Finkenstr. 61, 47057 Duisburg Germany
1 shared publication- Dirk Wünsch
Fraunhofer Institute for Electronic Nano Systems ENAS , 09126 Chemnitz , Germany
1 shared publication - Gerd Vom Bögel
Fraunhofer Institute for Microelectronic Circuits and Systems, Duisburg, Germany
1 shared publication
Latest Publications
- 13 December 2019
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (7-8) , 470-476
Design and simulation of a photonic crystal resonator as a biosensor for point-of-care applications
Point-of-care (POC) devices are essential for rapid testing of samples for early diagnosis of diseases. The accuracy and the sensitivity of the POC device depend mainly on the biosensors. The currently used POC devices require specialized operating personnel, long sample preparation time and high equipment costs. We aim to explain a bio-sensing concept using a photonic crystal (PC) resonator that would mitigate the drawbacks of the present sensing techniques. Photonic crystals consist of spatially arranged dielectric materials presenting a band gap that prevents electromagnetic waves of certain frequency range to propagate through it. PC resonators have shown to have very high sensitivities for bio-sensing applications at THz frequencies. A PC resonator with a high Q-factor is designed and simulated to detect the changes in the surrounding dielectric permittivity. As an application for detecting specific biomolecules, a protocol for surface functionalization has been explained. This will enable the selective binding of biomolecules from the sample. Shift in resonant frequency and attenuation in magnitude at the peak resonant frequency can be observed from the simulation results. These changes in the resonator properties can be indicative of the presence of a particular biomolecule or pathogen and its concentration within the sample.
- 13 December 2019
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (7-8) , 470-476
Design and simulation of a photonic crystal resonator as a biosensor for point-of-care applications
Point-of-care (POC) devices are essential for rapid testing of samples for early diagnosis of diseases. The accuracy and the sensitivity of the POC device depend mainly on the biosensors. The currently used POC devices require specialized operating personnel, long sample preparation time and high equipment costs. We aim to explain a bio-sensing concept using a photonic crystal (PC) resonator that would mitigate the drawbacks of the present sensing techniques. Photonic crystals consist of spatially arranged dielectric materials presenting a band gap that prevents electromagnetic waves of certain frequency range to propagate through it. PC resonators have shown to have very high sensitivities for bio-sensing applications at THz frequencies. A PC resonator with a high Q-factor is designed and simulated to detect the changes in the surrounding dielectric permittivity. As an application for detecting specific biomolecules, a protocol for surface functionalization has been explained. This will enable the selective binding of biomolecules from the sample. Shift in resonant frequency and attenuation in magnitude at the peak resonant frequency can be observed from the simulation results. These changes in the resonator properties can be indicative of the presence of a particular biomolecule or pathogen and its concentration within the sample.
- 1 April 2018
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 85 (5) , 359-365
Implantable multi-sensor system for hemodynamic controlling
A miniaturized implantable multi-sensor system for cardiovascular monitoring of physiological parameters is presented. High accuracy pressure measurements within the vessel can be performed by a capacitive pressure sensor. Additional information about the patient, e.g., sudden movement, inclination or increased temperature can be obtained by additional sensor components such as an acceleration sensor and a temperature sensor unit. This information facilitates compensation of interferences for more accurate pressure measurements. A multifunctional ASIC enables, amongst others, sensor signal processing, power management and telemetric communication with extracorporeal electronics. Sensor chips, the multi-functional ASIC and passive components are assembled on a LTCC circuit board in which an antenna coil is integrated for telemetric energy and data transmission at a frequency of 13.56 MHz. In order to support further miniaturization, the implant shall be encapsulated with a stack of very thin and hermetic ceramics applied by ALD instead of using bulky metal housings. Further encapsulation with polymers, which can be functionalised with appropriate biomolecules, is necessary for a proper shape, a biocompatible interface to the surrounding tissue and, thereby, reduction of thrombogenicity.
- 1 April 2018
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 85 (5) , 359-365
Implantable multi-sensor system for hemodynamic controlling
A miniaturized implantable multi-sensor system for cardiovascular monitoring of physiological parameters is presented. High accuracy pressure measurements within the vessel can be performed by a capacitive pressure sensor. Additional information about the patient, e.g., sudden movement, inclination or increased temperature can be obtained by additional sensor components such as an acceleration sensor and a temperature sensor unit. This information facilitates compensation of interferences for more accurate pressure measurements. A multifunctional ASIC enables, amongst others, sensor signal processing, power management and telemetric communication with extracorporeal electronics. Sensor chips, the multi-functional ASIC and passive components are assembled on a LTCC circuit board in which an antenna coil is integrated for telemetric energy and data transmission at a frequency of 13.56 MHz. In order to support further miniaturization, the implant shall be encapsulated with a stack of very thin and hermetic ceramics applied by ALD instead of using bulky metal housings. Further encapsulation with polymers, which can be functionalised with appropriate biomolecules, is necessary for a proper shape, a biocompatible interface to the surrounding tissue and, thereby, reduction of thrombogenicity.
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 123-126
DRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects
Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 123-126
Open AccessDRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects
Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.
- 20 December 2016
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 84 (1) , 53-58
Telemetric multi-sensor system for medical applications – The approach
Long-term monitoring of hemodynamics can be achieved by an implantable and telemetric multi-sensor system. A concept to realize a system with high miniaturization level is presented. The requirements regarding a multifunctional transponder ASIC (application specific integrated circuit), which should combine signal processing, telemetric communication and additional sensors in one chip, are introduced. Capacitive pressure sensors showing low power consumption were tested with laboratory setups with respect to the integration in this concept. First results were achieved and discussed concerning two potential assembly technologies for the integration of a pressure sensor. Finally, hermetic sealing and implant encapsulation technologies are proposed for further implant miniaturization.
- 20 December 2016
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 84 (1) , 53-58
Telemetric multi-sensor system for medical applications – The approach
Long-term monitoring of hemodynamics can be achieved by an implantable and telemetric multi-sensor system. A concept to realize a system with high miniaturization level is presented. The requirements regarding a multifunctional transponder ASIC (application specific integrated circuit), which should combine signal processing, telemetric communication and additional sensors in one chip, are introduced. Capacitive pressure sensors showing low power consumption were tested with laboratory setups with respect to the integration in this concept. First results were achieved and discussed concerning two potential assembly technologies for the integration of a pressure sensor. Finally, hermetic sealing and implant encapsulation technologies are proposed for further implant miniaturization.