MGMichael Görtz

Michael Görtz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Michael Görtz has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Implantable multi-sensor system for hemodynamic controlling

    by Jens Weidenmüller, Oezgue Dogan, Alexander Stanitzki, Mario Baum, Tim Schröder, Dirk Wünsch, Michael Görtz, Anton Grabmaier

    A miniaturized implantable multi-sensor system for cardiovascular monitoring of physiological parameters is presented. High accuracy pressure measurements within the vessel can be performed by a capacitive pressure sensor. Additional information about the patient, e.g., sudden movement, inclination or increased temperature can be obtained by additional sensor components such as an acceleration sensor and a temperature sensor unit. This information facilitates compensation of interferences for more accurate pressure measurements. A multifunctional ASIC enables, amongst others, sensor signal processing, power management and telemetric communication with extracorporeal electronics. Sensor chips, the multi-functional ASIC and passive components are assembled on a LTCC circuit board in which an antenna coil is integrated for telemetric energy and data transmission at a frequency of 13.56 MHz. In order to support further miniaturization, the implant shall be encapsulated with a stack of very thin and hermetic ceramics applied by ALD instead of using bulky metal housings. Further encapsulation with polymers, which can be functionalised with appropriate biomolecules, is necessary for a proper shape, a biocompatible interface to the surrounding tissue and, thereby, reduction of thrombogenicity.


  • Open Access

    DRUGAS: implantable telemetric system for measuring the portal venous pressure: assembly aspects

    by Roland Fischer, Jens Weidenmüller, Michael Görtz, Thorsten Goettsche, Wilfried Mokwa

    Developing an implantable, telemetric pressure measuring system for venous applications makes a high degree of miniaturization necessary. Thus the influence on the measurement environment is minimized and the risk of thrombosis at small flow blood velocities is decreased. But these systems are limited in terms of accuracy and resolution. The asked system requirements could only be reached by optimising the assembly and encapsulation techniques. To achieve the high degree of miniaturization numerical simulations were performed on the shape and size of the implant and led to the development of a specific metal housing consisting of two main components. A small measuring chamber will be placed into the portal vein and is rigidly fixed to a flat circular part that contains the pressure sensor chip and a transponder board and will be located outside on top of the vein. The main focus of the assembly process was based on a stress-free design and mounting of the components.

  • Poster session 10: Medical measuring techniques I

    by Pavel Livshits, Andreas Jupe, Stefan Kahnert, Martin Figge, Stefan Mross, Michael Goertz, Holger Vogt, Andreas Goehlich

  • Session 10. Medical measuring techniques I

    by Jens Weidenmüller, Özgü Dogan, Alexander Stanitzki, Mario Baum, Dirk Wünsch, Maik Wiemer, Michael Görtz

  • Telemetric multi-sensor system for medical applications – The approach

    by Jens Weidenmüller, Christian Walk, Özgü Dogan, Pierre Gembaczka, Alexander Stanitzki, Michael Görtz

    Long-term monitoring of hemodynamics can be achieved by an implantable and telemetric multi-sensor system. A concept to realize a system with high miniaturization level is presented. The requirements regarding a multifunctional transponder ASIC (application specific integrated circuit), which should combine signal processing, telemetric communication and additional sensors in one chip, are introduced. Capacitive pressure sensors showing low power consumption were tested with laboratory setups with respect to the integration in this concept. First results were achieved and discussed concerning two potential assembly technologies for the integration of a pressure sensor. Finally, hermetic sealing and implant encapsulation technologies are proposed for further implant miniaturization.