Tenzin Sonam Stelljes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tenzin Sonam Stelljes has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
Björn Poppe
University Clinic for Medical Radiation Physics, Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany
2 shared publicationsHui Khee Looe
University Clinic for Medical Radiation Physics, Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany
2 shared publications- Björn Poppe
Department of Medical Radiation Physics, Pius-Hospital, Carl von Ossietzky University Oldenburg, 26133 Oldenburg, Germany
1 shared publication - Britta Loutfi-Krauss
Universitäts-klinikum Frankfurt, Klinik für Strahlentherapie und Onkologie , Theodor-Stern-Kai 7 , 60590 Frankfurt , Germany
1 shared publication Daniela Poppinga
University Clinic for Medical Radiation Physics, Medical Campus Pius Hospital, Carl von Ossietzky University, Oldenburg, Germany
1 shared publicationDietrich Harder
Prof. em., Medical Physics and Biophysics, Georg-August-University, Göttingen, Germany
1 shared publication
Latest Publications
- 1 February 2019
- Published by Wiley in Medical Physics
- Vol. 46 (4) , 1863-1873
Experimental determination of the “collimator monitoring fill factor” and its relation to the error detection capabilities of various 2D‐arrays
Purpose The collimator monitoring fill factor (CM‐FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM‐FF) introduced by Gago‐Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D‐arrays. The error detection capabilities of 2D‐arrays were studied by comparing detector signal changes and local gamma index passing rates in different field setups with introduced collimation errors. Methods The fill factor is defined as the ratio of the sensitive detector area and the cell area of a detector, defined by the detector arrangement on a 2D‐array. Gago‐Arias et al. calculated the FWHM‐FF, using the FWHM² of a detector's fluence response function KM(x) as the sensitive detector area. For the CM‐FF a sensitive detector width w(Δ mm, d%) is calculated. The sensitive detector width is the lateral extent of KM(x), lying inside the detector cell area, along which a collimator error of Δ mm yields a signal change exceeding a detection threshold of d%. The sensitive area for a single detector is calculated using w(Δ mm, d%)². The CM‐FF is then calculated as the ratio of the sensitive area of a detector within its cell area and the detector cell area. The fluence response functions of the central detector of the OCTAVIUS 729, 1500 and 1000 SRS array (all PTW‐Freiburg, Freiburg, Germany) and the MapCHECK 2 array (Sun Nuclear, Melbourne, US) were measured using a photon slit beam. The FWHM‐FF and the CM‐FF were calculated and compared for all 2D‐arrays under investigation. The error detection capabilities of 2D‐arrays in quadratic fields were studied by investigating the signal changes in the detectors adjacent to the collimator edge when changing the collimator position. The change in local gamma index passing rate with respect to the introduced collimator error was investigated for an ionization chamber and a diode array in quadratic and two intensity modulated fields. Results Values for the CM‐FF and FWHM‐FF were 1.0 and 0.35 respectively for the area of the liquid‐filled 1000 SRS ionization chamber array with a detector to detector distance of 5 mm and 0.32 and 0.04 respectively for the MapCHECK 2 diode array. For the vented ionization chamber array OCTAVIUS 729 fill factors were calculated as CM‐FF=0.59 and FWHM‐FF=0.53, while the OCTAVIUS 1500 array yielded fill factors of CM‐FF=0.77 and FWHM‐FF=0.72. Signal changes in vented ionization chambers for collimator errors of 1 mm surpassed those of diodes by a factor of 2 in quadratic fields. The gamma index passing rates in quadratic fields reflect those findings. In intensity modulated fields the decline of the gamma index passing rate is bigger for the ionization chamber array compared to the diode array when introducing collimator errors. Conclusions The calculated values of the CM‐FF correlate with the signal changes in quadratic field setups with introduced collimator position errors of 1 mm, while the FWHM‐FF underestimates the error detection capabilities of 2D‐arrays. An increased error detection capability of the ionization chamber array compared to diode array was observed in quadratic and intensity modulated fields.
- 1 February 2019
- Published by Wiley in Medical Physics
- Vol. 46 (4) , 1863-1873
Experimental determination of the “collimator monitoring fill factor” and its relation to the error detection capabilities of various 2D‐arrays
Purpose The collimator monitoring fill factor (CM‐FF) introduced by Stelljes et al. (2017) and the FWHM fill factor (FWHM‐FF) introduced by Gago‐Arias et al. (2012) were determined using the measured photon fluence response functions of various 2D‐arrays. The error detection capabilities of 2D‐arrays were studied by comparing detector signal changes and local gamma index passing rates in different field setups with introduced collimation errors. Methods The fill factor is defined as the ratio of the sensitive detector area and the cell area of a detector, defined by the detector arrangement on a 2D‐array. Gago‐Arias et al. calculated the FWHM‐FF, using the FWHM² of a detector's fluence response function KM(x) as the sensitive detector area. For the CM‐FF a sensitive detector width w(Δ mm, d%) is calculated. The sensitive detector width is the lateral extent of KM(x), lying inside the detector cell area, along which a collimator error of Δ mm yields a signal change exceeding a detection threshold of d%. The sensitive area for a single detector is calculated using w(Δ mm, d%)². The CM‐FF is then calculated as the ratio of the sensitive area of a detector within its cell area and the detector cell area. The fluence response functions of the central detector of the OCTAVIUS 729, 1500 and 1000 SRS array (all PTW‐Freiburg, Freiburg, Germany) and the MapCHECK 2 array (Sun Nuclear, Melbourne, US) were measured using a photon slit beam. The FWHM‐FF and the CM‐FF were calculated and compared for all 2D‐arrays under investigation. The error detection capabilities of 2D‐arrays in quadratic fields were studied by investigating the signal changes in the detectors adjacent to the collimator edge when changing the collimator position. The change in local gamma index passing rate with respect to the introduced collimator error was investigated for an ionization chamber and a diode array in quadratic and two intensity modulated fields. Results Values for the CM‐FF and FWHM‐FF were 1.0 and 0.35 respectively for the area of the liquid‐filled 1000 SRS ionization chamber array with a detector to detector distance of 5 mm and 0.32 and 0.04 respectively for the MapCHECK 2 diode array. For the vented ionization chamber array OCTAVIUS 729 fill factors were calculated as CM‐FF=0.59 and FWHM‐FF=0.53, while the OCTAVIUS 1500 array yielded fill factors of CM‐FF=0.77 and FWHM‐FF=0.72. Signal changes in vented ionization chambers for collimator errors of 1 mm surpassed those of diodes by a factor of 2 in quadratic fields. The gamma index passing rates in quadratic fields reflect those findings. In intensity modulated fields the decline of the gamma index passing rate is bigger for the ionization chamber array compared to the diode array when introducing collimator errors. Conclusions The calculated values of the CM‐FF correlate with the signal changes in quadratic field setups with introduced collimator position errors of 1 mm, while the FWHM‐FF underestimates the error detection capabilities of 2D‐arrays. An increased error detection capability of the ionization chamber array compared to diode array was observed in quadratic and intensity modulated fields.
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 277-280
Usability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery
For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 277-280
Open AccessUsability and accuracy of high-resolution detectors for daily quality assurance for robotic radiosurgery
For daily CyberKnife QA a Winston-Lutz-Test (Automated-Quality-Assurance, AQA) is used to determine sub-millimeter deviations in beam delivery accuracy. This test is performed using gafchromic film, an extensive and user-dependent method requiring the use of disposables. We therefore analyzed the usability and accuracy of high-resolution detector arrays. We analyzed a liquid-filled ionization-chamber array (Octavius 1000SRS, PTW, Germany), which has a central resolution of 2.5mm. To test sufficient sensitivity, beam profiles with robot shifts of 0.1mm along the arrays' axes were measured. The detected deviation between the shifted and central profile were compared to the real robot's position. We then compared the results to the SRS-Profiler (SunNuclear, USA) with 4.0mm resolution and to the Nonius (QUART, Germany), a single-line diode detector with 2.8mm resolution. Finally, AQA variance and usability were analyzed performing a number of AQA tests over time, which required the use of specially designed fixtures for each array, and the results were compared to film. Concerning sensitivity, the 1000SRS detected the beam profile shifts with a maximum difference of 0.11mm (mean deviation = 0.03mm) compared to the actual robot shift. The Nonius and SRS-Profiler showed differences of up to 0.15mm and 0.69mm with mean deviation of 0.05mm and 0.18mm, respectively. Analyzing the variation of AQA results over time, the 1000SRS showed a comparable standard deviation to film (0.26mm vs. 0.18mm). The SRS-Profiler and the Nonius showed a standard deviation of 0.16mm and 0.24mm, respectively. The 1000SRS seems to provide equivalent accuracy and sensitivity to the gold standard film when performing daily AQA tests. Compared to other detectors in our study the sensitivity as well as the accuracy of the 1000SRS appears to be superior and more user-friendly. Furthermore, no significant modification of the standard AQA procedure is required when introducing 1000SRS for CyberKnife AQA.
- 17 January 2017
- Published by Wiley in Medical Physics
- Vol. 44 (3) , 1128-1138
The “collimator monitoring fill factor” of a two‐dimensional detector array, a measure of its ability to detect collimation errors
Purpose: Two‐dimensional detector arrays are routinely used for constancy checks and treatment plan verification in photon‐beam radiotherapy. In addition to the spatial resolution of the dose profiles, the “coverage” of the radiation field with respect to the detection of any beam collimation deficiency appears as the second characteristic feature of a detector array. The here proposed “collimator monitoring fill factor” (CM fill factor) has been conceived to serve as a quantitative characteristic of this “coverage”.Methods: The CM fill factor is defined as the probability of a 2D array to detect any collimator position error. Therefore, it is represented by the ratio of the “sensitive area” of a single detector, in which collimator position errors are detectable, and the geometrical “cell area” associated with this detector within the array. Numerical values of the CM fill factor have been Monte Carlo simulated for 2D detector arrays equipped with air‐vented ionization chambers, liquid‐filled ionization chambers and diode detectors and were compared with the “FWHM fill factor” defined by Gago‐Arias et al. (2012).Results: For arrays with vented ionization chambers, the differences between the CM fill factor and the FWHM fill factor are moderate, but occasionally the latter exceeds unity. For narrower detectors such as liquid‐filled ionization chambers and Si diodes and for small sampling distances, large differences between the FWHM fill factor and the CM fill factor have been observed. These differences can be explained by the shapes of the fluence response functions of these narrow detectors.Conclusions: A new parameter “collimator monitoring fill factor” (CM fill factor), applicable to quantitate the collimator position error detection probability of a 2D detector array, has been proposed. It is designed as a help in classifying the clinical performance of two‐dimensional detector arrays in photon‐beam radiotherapy.
- 17 January 2017
- Published by Wiley in Medical Physics
- Vol. 44 (3) , 1128-1138
The “collimator monitoring fill factor” of a two‐dimensional detector array, a measure of its ability to detect collimation errors
Purpose: Two‐dimensional detector arrays are routinely used for constancy checks and treatment plan verification in photon‐beam radiotherapy. In addition to the spatial resolution of the dose profiles, the “coverage” of the radiation field with respect to the detection of any beam collimation deficiency appears as the second characteristic feature of a detector array. The here proposed “collimator monitoring fill factor” (CM fill factor) has been conceived to serve as a quantitative characteristic of this “coverage”.Methods: The CM fill factor is defined as the probability of a 2D array to detect any collimator position error. Therefore, it is represented by the ratio of the “sensitive area” of a single detector, in which collimator position errors are detectable, and the geometrical “cell area” associated with this detector within the array. Numerical values of the CM fill factor have been Monte Carlo simulated for 2D detector arrays equipped with air‐vented ionization chambers, liquid‐filled ionization chambers and diode detectors and were compared with the “FWHM fill factor” defined by Gago‐Arias et al. (2012).Results: For arrays with vented ionization chambers, the differences between the CM fill factor and the FWHM fill factor are moderate, but occasionally the latter exceeds unity. For narrower detectors such as liquid‐filled ionization chambers and Si diodes and for small sampling distances, large differences between the FWHM fill factor and the CM fill factor have been observed. These differences can be explained by the shapes of the fluence response functions of these narrow detectors.Conclusions: A new parameter “collimator monitoring fill factor” (CM fill factor), applicable to quantitate the collimator position error detection probability of a 2D detector array, has been proposed. It is designed as a help in classifying the clinical performance of two‐dimensional detector arrays in photon‐beam radiotherapy.