Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ryszard Zwierzchowski has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of Thermal Energy Storage on the Emission of Particulate Pollutants into the Atmosphere

    by Ryszard Zwierzchowski, Marlena Ziomacka, Olgierd Niemyjski

    To improve the energy, operational, and ecological efficiency of a district heating system (DHS) powered by a combined heat and power (CHP) plant or a heating plant, thermal energy storage (TES) should be used. The presented paper examines the impact of the use and operation of TES built in a CHP plant supplying a large DHS, based on the amount of particulates emitted into the atmosphere. Detailed research was carried out for the Siekierki–Warsaw and Białystok CHP plants in Poland. The analysis helped to determine the factors affecting the reduction in pollutant emissions and the volume of the energy effect of using TES in the CHP plant. In order to objectify the results of the comparative analysis of the impact of TES in the CHP plant on the emission of particulates, the so-called comparative index (CI) was introduced. The CI takes into account the volume of electricity and heat production and climatic conditions in the analyzed time periods. The CI for the analyzed years should have a similar value so that the results of the comparative analysis are fully representative. This condition is met for the CHP plant and DHS of Białystok, so the detailed results of the analysis are presented for this facility. As a result of the application of TES in the Białystok CHP plant, significant environmental effects related to the reduction in particulate emissions have been achieved; for example, the total amount of annual particulate matter (PM) emission (PM10 and PM2.5) has been reduced by 27% and the maximum emission by 29%. On the other hand, the average decrease in particulate emissions in the heating season varied in the range of 10–50%, while in the summer season, the values of particulate emissions were at a comparable level. A significant decrease in annual and one-hour average concentrations for PM10 and PM2.5 and particulate fallout for these two analyzed years was also found. The use of TES to reduce the occurrence and nuisance of the smog phenomenon, the main components of which are PM, is proposed, and selected models of forecasting concentrations of pollutants in the air, including particulate emissions, are presented in order to implement this type of activity.


  • Open Access

    The Impact of the Use of a Thermal Energy Storage on the Emission of Particulate Pollutants into the Atmosphere

    by Ryszard Zwierzchowski, Marlena Ziomacka, Olgierd Niemyjski

    In order to improve the energy, operational and ecological efficiency of District Heating Systems (DHS) powered by a Combined Heat and Power (CHP) plant or a Heating Plant, Thermal Energy Storages (TES) should be used. Improvement of energy efficiency is primarily associated with greater operational efficiency of energy generation, improvement of operational efficiency and fewer start-ups and number of operating hours of peak boilers. Improving ecological efficiency is associated with lower emissions of pollutants into the atmosphere. The presented paper examines the impact of the use and operation of a TES built in a CHP plant supplying a large DHS on the amount of particulates emission to the atmosphere. Detailed research was carried out for Siekierki-Warsaw and Białystok CHP plants in Poland. The analysis allowed to determine the factors affecting the reduction of pollutant emissions and the volume of the energy effect of using a TES in the CHP plant. In order to objectify the results of the comparative analysis of the impact of TES in CHP plant on the emission of particulates, the so-called Comparative Index (CI) was in-troduced, which takes into account the volume of electricity and heat production and climatic conditions in the analyzed time periods. The CI for the analyzed years, should have a similar value so that the results of the comparative analysis are fully representative. This condition is met for the selected base and comparative year for the CHP plant and DHS of Białystok, so the detailed results of analysis are presented for this facility. As a result of the application of TES in Białystok CHP plant, significant environmental effects related to the reduction of particulates emission have been achieved, for example, the total amount of annual Particulate Matters (PM) emission (PM10 and PM2.5) has been reduced by 27% and the maximum emission by 29%. On the other hand, the average decrease in particulates emission in the heating season varied in the range of 10 - 50%, while in the summer season the values of particulates emission were at a comparable level. A significant decrease in annual and one-hour average concentrations for PM10 and PM2.5 and particulates fallout for these two analyzed years was also found. The use of TES to reduce the occurrence and nuisance of the smog phenomenon, the main components of which are PM, is proposed, and selected models of forecasting concentrations of pollutants in the air, including particulates emission, are presented in order to implement this type of activities.


  • Open Access

    Multigeneration source based on novel triple-component chiller configuration co-supplied with renewable and fossil energy operated in Arabic Peninsula conditions

    by Fahad Alkasmoul, Mohammed Asaker, Aleksander Widuch, Marcin Malicki, Ryszard Zwierzchowski, Marcin Wołowicz


  • Open Access

    Energy Savings Analysis for Operation of Steam Cushion System for Sensible Thermal Energy Storages

    by Ryszard Zwierzchowski, Olgierd Niemyjski, Marcin Wołowicz

    The paper presents an analytical discussion of how to improve the energy efficiency of the steam cushion system operation for a Thermal Energy Storage (TES) tank. The EU’s green deal 2050 target policy requires an increase in the energy efficiency of energy production and use, as well as an increase in the share of renewable energy in the overall energy production balance. The use of energy-efficient TES is considered as one of the most important technologies to achieve the objectives of this EU policy. The analyses presented in the paper of energy-efficient operation of steam cushion (SC) systems were carried out by using operational data received from three District Heating Systems (DHSs) that supply heat and electricity to one of the largest cities in Poland and are equipped with the TES systems. These three analyzed TESs differ in capacities from 12,800 to 30,400 m3, tank diameters from 21 to 30 m and shell height from 37 to 48.2 m. The main purpose of using a steam cushion system in the TES tank is to protect the water stored in it against the absorption of oxygen from the surrounding atmospheric air through the surge chamber and safety valves located on the roof of the tank. The technical solutions presented here for the upper orifice for charging and discharging hot water into/from the tank and the suction pipe for circulating water allow to us achieve significant energy savings in the steam cushion systems. Both the upper orifice and the end of suction pipe are movable through the use of pontoons. Thanks to the use of this technical solution, a stable insulating water layer is created above the upper orifice in the upper part of the TES tank, where convective and turbulent transport of heat from the steam cushion space to the hot water stored in the tank is significantly limited. Ultimately, this reduces the heat flux by approximately 90% when compared to the classic technical solutions of steam cushion systems in TES tanks, i.e., for the upper orifice and circulation water pipe. The simplified analysis presented in the paper and comparison of its results with experimental data for heat flow from the steam cushion space to hot water stored in the upper part of the TES tank fully confirms the usefulness of the heat-flow models used.


  • Operational determinants of gaseous air pollutants emissions from coal-fired district heating sources

    by Ryszard Zwierzchowski, Ewelina Różycka-Wrońska

    This study describes the correlation between emission of gaseous pollutants to the atmosphere and the combustion parameters of a coal-fired 25 MW heating capacity water boiler with mechanical grate (boiler type WR-25) in unstable working conditions: start-up, shutdown and loads below the technical minimum. Whereas measurements were made for a specific type and size of coal-fired water boiler with mechanical grate, the measurements and calculations are applicable to WR boilers with a different heating power as well as OR type steam boilers, which have a practically identical design. In sum, there are more than 1,000 coal-fired water and steam boilers of these types in Poland. In addition, the analysis reported in this paper highlights the important role played by boilers operating in unstable conditions in terms of emission of gaseous pollutants to the atmosphere. The conclusions are relevant for other boilers fi red with gas, oil or biomass operating under conditions such as start-up, shutdown and loads below the technical minimum. This article fi lls a gap in air protection engineering practice and the literature with regard to indicators and emission standards, drawing on measurements of pollutant concentrations in the exhaust gases from unstable WR boiler working conditions. The measurements can be used to assess the emission of pollutants to the atmosphere in such boiler working conditions and their impact on air quality. The analyses presented were based on the authors’ own measurements in WR-25 boiler technical installations using portable gas analyser GASMET DX-4000, which uses the FT-IR measurement method for compounds such as SO2, NOx, HCl, HF, NH3, CH4, and CO. Concentrations of CO, NOx and SO2 in exhaust gases were determined with multiple regression with the STATISTICA statistical software and with linear regression complemented by the “smart” package in the MATLAB environment. The study provides computational models to identify pollutant concentrations in the exhaust gases in any working conditions of WR-25 boilers


  • Open Access

    Impact of Water Temperature Changes on Water Loss Monitoring in Large District Heating Systems

    by Olgierd Niemyjski, Ryszard Zwierzchowski

    This paper explores how water temperature changes in a district heating system (DHS) impact the monitoring of water losses. Water volume in DHS is constantly monitored, recorded, and replenished. The leakage and failure status of the DHS is often monitored through measuring the make-up water flow rate. In this paper, we present the methodology and a simplified model of the dynamics of the heating system operation, which was used to determine the profile of changes in the average temperature and density of water in the system. The mathematical model of the district heating network (DHN) was verified by comparing the results of simulation calculations, i.e., calculated values of the temperature of water returning to the heat source, with the measured values. Fluctuations in water temperature cause changes in the density and volume of water in the DHN, which affect the amount of water supplementing the system. This is particularly noticeable in a DHN with a large water volume. The study reports an analysis of measurement results of operating parameters of a major DHS in Poland (city of Szczecin). Hourly measurements were made of supply and return water temperature, water flow rate, and pressure throughout the whole of 2019. The water volume of the analyzed DHN is almost 42,000 m3 and the changes in water volume per hour are as high as 5 m3/h, representing 20–30% of the value of the make-up water flow rate. The analysis showed that systems for monitoring the tightness of the DHS and detecting failures, on the basis of measurements of the make-up water flow rate, should take into account the dynamics of water volume changes in the DHN.


  • Open Access

    Energy and Exergy Analysis of Sensible Thermal Energy Storage—Hot Water Tank for a Large CHP Plant in Poland

    by Ryszard Zwierzchowski, Marcin Wołowicz

    The paper contains a simplified energy and exergy analysis of pumps and pipelines system integrated with Thermal Energy Storage (TES). The analysis was performed for a combined heat and power plant (CHP) supplying heat to the District Heating System (DHS). The energy and exergy efficiency for the Block Part of the Siekierki CHP Plant in Warsaw was estimated. CHP Plant Siekierki is the largest CHP plant in Poland and the second largest in Europe. The energy and exergy analysis was executed for the three different values of ambient temperature. It is according to operation of the plant in different seasons: winter season (the lowest ambient temperature Tex = −20 °C, i.e., design point conditions), the intermediate season (average ambient temperature Tex = 1 °C), and summer (average ambient temperature Tex = 15 °C). The presented results of the analysis make it possible to identify the places of the greatest exergy destruction in the pumps and pipelines system with TES, and thus give the opportunity to take necessary improvement actions. Detailed results of the energy-exergy analysis show that both the energy consumption and the rate of exergy destruction in relation to the operation of the pumps and pipelines system of the CHP plant with TES for the tank charging and discharging processes are low.


  • Open Access

    Improvement of operation of steam cushion system for sensible thermal energy storage

    by Ryszard Zwierzchowski

    The paper contains a method for improvement of operation of steam cushion system including its energy savings analyses, for a Thermal Energy Storage (TES) tank. Energy savings analyses were performed using operational data from selected Combined Heat and Power plants, which supply heat to large cities in Poland and are furnished with the TES. The role of the steam cushion system in the TES tank is to prevent the stored water against absorbing oxygen from atmospheric air. In the TES tank, which is a non-pressure tank, oxygen from atmospheric air could penetrate to the network water through the surge chamber and safety valves. The steam pressure under the roof is generated from technological steam injected under the roof. Energy savings in the steam cushion system are generated by using an appropriate technical solution for the upper orifice and suction pipe for circulation water, i.e., to make it movable through the use of pontoons. An isolating buffer layer is created at the top of the tank with very small convective and turbulent heat transport, which causes limited heat transfer from steam bed to the stored water in the tank. This results in heat flux of approximately 10% of the heat flux that occurs in the typical technical solution of the upper orifice and suction pipe for circulation water in the TES tank. This technology offers great opportunities to improve the operating conditions of District Heating System, cutting energy production costs and emissions of pollutants to the atmosphere.


  • Open Access

    Simulation of Heat Losses of a Distribution Network with Different Technical Structure and Under Different Operating Conditions for a District Heating and Cooling System

    by Ryszard Zwierzchowski, Olgierd Niemyjski

    The paper presents a simulation of heat losses of a distribution network with different technical structure and under different operating conditions for a District Heating and Cooling (DHC) system. The DHC system consists of a Combined Heat and Power (CHP) plant and a Distribution Network (DN) with chambers and heat and cold substations. The different operating conditions of the DHC systems result in the DNs having variable transportation losses. The result of the analysis was used to verify the models and calculation methods of the fluid flow and heat losses in the DN, when cold is generated using either absorption or adsorption chillers. Different technical structure of a DN means a system of connected underground and aboveground piping with different diameters. DNs in Poland are usually installed as an underground, traditionally insulated piping placed in the concrete ducts (large diameter main pipelines) or a pre-insulated piping placed directly in the ground. The total heat losses of the DN differ according to the individual systems and depend on the size of the DHC system, its heating loads and quality of insulation of the piping. This paper presents the results of the numerical calculation of the temperature distribution in the soil around the piping channel using an FDA model. These results were utilized for numerical simulation of the water and heat flow through the DN and calculation of heat transportation losses. The numerical simulation of heat losses was performed for the particular system of connected underground and aboveground piping with different diameters. Finally, the heat transportation losses of the DN were calculated and compared for analyzed District Heating (DH) system i.e. without cold consumers and for the DHC system, when cold for consumers is generated using either the absorption or the adsorption chillers.


  • Open Access

    Method of improvement of operational and technical conditions of a large cooling water system

    by Ryszard Zwierzchowski, Michal Pachocki

    Increasing the energy efficiency of industrial installations is one of the European Union’s priorities for achieving energy policy goals. These goals can be achieved, among others, by applying the appropriate methodology for modernization of cooling water distribution pipelines and improving their operation. Water distribution in cooling systems of large industrial installations is associated with significant hydraulic losses due to large flows and spatial spread of these systems. The losses are unavoidable and have a decisive impact on the energy consumption for pumping. Thanks to optimal design solutions, implementation of the repair program and proper operation of cooling water transmission pipelines, it is possible to significantly reduce hydraulic losses and water leakage. This will translate into reduced energy consumption for pumping and, as a result, improved energy efficiency. Abovementioned goals can be achieved by replacing or renovating pipelines. This paper deals with determination of a method and schedule of modernization of cooling water piping systems on the basis of a case study – a large industrial plant. Firstly, evaluation of the existing condition is carried out. Data on flow rate and cooling water pressure in the system are collected and analyzed. A graphical and numerical database of the cooling water system is made, which maps the system in terms of system geometry (lengths, pipe diameters, ordinates) and flow and pressure streams. The hydraulic losses of the cooling water system are simulated. The results of simulation calculations of pressure losses in water distribution system are presented in the form of maps of water pressure distribution in pipelines. Calculations for the pipeline network are performed in the current state for two hydraulic load cases: maximum and average. An assessment of the failure rate is made on the basis of information about the place, time, cause and type of damage. Wall thickness of pipelines in selected locations is measured and samples are taken from pipes in places of failure. The reasons for water pipeline failures are diagnosed. On the basis of pre-modernization simulation, information on failure rate and forecasts of future water demand are obtained, it is proposed which pipeline sections and in what order should be modernized. Depending on the technical condition, pipeline diameter and location in the field, pipe replacement or renovation is recommended. For pipes to be replaced, new diameters, adjusted to the forecasted demand are calculated. For pipes qualified for renovation, different site hardened liners or full wall pipes are recommended depending on pipe condition. Renovation methods, despite the reduction of the internal cross-section, provide similar or lower hydraulic resistance values. After selecting the variants of modernization of distribution pipelines, hydraulic simulations are carried out in the post-modernization condition, taking into account the future demand for cooling water. The presented method can be applied to cooling water systems as well as other industrial water piping systems.