Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Olgierd Niemyjski has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of Thermal Energy Storage on the Emission of Particulate Pollutants into the Atmosphere

    by Ryszard Zwierzchowski, Marlena Ziomacka, Olgierd Niemyjski

    To improve the energy, operational, and ecological efficiency of a district heating system (DHS) powered by a combined heat and power (CHP) plant or a heating plant, thermal energy storage (TES) should be used. The presented paper examines the impact of the use and operation of TES built in a CHP plant supplying a large DHS, based on the amount of particulates emitted into the atmosphere. Detailed research was carried out for the Siekierki–Warsaw and Białystok CHP plants in Poland. The analysis helped to determine the factors affecting the reduction in pollutant emissions and the volume of the energy effect of using TES in the CHP plant. In order to objectify the results of the comparative analysis of the impact of TES in the CHP plant on the emission of particulates, the so-called comparative index (CI) was introduced. The CI takes into account the volume of electricity and heat production and climatic conditions in the analyzed time periods. The CI for the analyzed years should have a similar value so that the results of the comparative analysis are fully representative. This condition is met for the CHP plant and DHS of Białystok, so the detailed results of the analysis are presented for this facility. As a result of the application of TES in the Białystok CHP plant, significant environmental effects related to the reduction in particulate emissions have been achieved; for example, the total amount of annual particulate matter (PM) emission (PM10 and PM2.5) has been reduced by 27% and the maximum emission by 29%. On the other hand, the average decrease in particulate emissions in the heating season varied in the range of 10–50%, while in the summer season, the values of particulate emissions were at a comparable level. A significant decrease in annual and one-hour average concentrations for PM10 and PM2.5 and particulate fallout for these two analyzed years was also found. The use of TES to reduce the occurrence and nuisance of the smog phenomenon, the main components of which are PM, is proposed, and selected models of forecasting concentrations of pollutants in the air, including particulate emissions, are presented in order to implement this type of activity.


  • Open Access

    The Impact of the Use of a Thermal Energy Storage on the Emission of Particulate Pollutants into the Atmosphere

    by Ryszard Zwierzchowski, Marlena Ziomacka, Olgierd Niemyjski

    In order to improve the energy, operational and ecological efficiency of District Heating Systems (DHS) powered by a Combined Heat and Power (CHP) plant or a Heating Plant, Thermal Energy Storages (TES) should be used. Improvement of energy efficiency is primarily associated with greater operational efficiency of energy generation, improvement of operational efficiency and fewer start-ups and number of operating hours of peak boilers. Improving ecological efficiency is associated with lower emissions of pollutants into the atmosphere. The presented paper examines the impact of the use and operation of a TES built in a CHP plant supplying a large DHS on the amount of particulates emission to the atmosphere. Detailed research was carried out for Siekierki-Warsaw and Białystok CHP plants in Poland. The analysis allowed to determine the factors affecting the reduction of pollutant emissions and the volume of the energy effect of using a TES in the CHP plant. In order to objectify the results of the comparative analysis of the impact of TES in CHP plant on the emission of particulates, the so-called Comparative Index (CI) was in-troduced, which takes into account the volume of electricity and heat production and climatic conditions in the analyzed time periods. The CI for the analyzed years, should have a similar value so that the results of the comparative analysis are fully representative. This condition is met for the selected base and comparative year for the CHP plant and DHS of Białystok, so the detailed results of analysis are presented for this facility. As a result of the application of TES in Białystok CHP plant, significant environmental effects related to the reduction of particulates emission have been achieved, for example, the total amount of annual Particulate Matters (PM) emission (PM10 and PM2.5) has been reduced by 27% and the maximum emission by 29%. On the other hand, the average decrease in particulates emission in the heating season varied in the range of 10 - 50%, while in the summer season the values of particulates emission were at a comparable level. A significant decrease in annual and one-hour average concentrations for PM10 and PM2.5 and particulates fallout for these two analyzed years was also found. The use of TES to reduce the occurrence and nuisance of the smog phenomenon, the main components of which are PM, is proposed, and selected models of forecasting concentrations of pollutants in the air, including particulates emission, are presented in order to implement this type of activities.


  • Open Access

    Energy Savings Analysis for Operation of Steam Cushion System for Sensible Thermal Energy Storages

    by Ryszard Zwierzchowski, Olgierd Niemyjski, Marcin Wołowicz

    The paper presents an analytical discussion of how to improve the energy efficiency of the steam cushion system operation for a Thermal Energy Storage (TES) tank. The EU’s green deal 2050 target policy requires an increase in the energy efficiency of energy production and use, as well as an increase in the share of renewable energy in the overall energy production balance. The use of energy-efficient TES is considered as one of the most important technologies to achieve the objectives of this EU policy. The analyses presented in the paper of energy-efficient operation of steam cushion (SC) systems were carried out by using operational data received from three District Heating Systems (DHSs) that supply heat and electricity to one of the largest cities in Poland and are equipped with the TES systems. These three analyzed TESs differ in capacities from 12,800 to 30,400 m3, tank diameters from 21 to 30 m and shell height from 37 to 48.2 m. The main purpose of using a steam cushion system in the TES tank is to protect the water stored in it against the absorption of oxygen from the surrounding atmospheric air through the surge chamber and safety valves located on the roof of the tank. The technical solutions presented here for the upper orifice for charging and discharging hot water into/from the tank and the suction pipe for circulating water allow to us achieve significant energy savings in the steam cushion systems. Both the upper orifice and the end of suction pipe are movable through the use of pontoons. Thanks to the use of this technical solution, a stable insulating water layer is created above the upper orifice in the upper part of the TES tank, where convective and turbulent transport of heat from the steam cushion space to the hot water stored in the tank is significantly limited. Ultimately, this reduces the heat flux by approximately 90% when compared to the classic technical solutions of steam cushion systems in TES tanks, i.e., for the upper orifice and circulation water pipe. The simplified analysis presented in the paper and comparison of its results with experimental data for heat flow from the steam cushion space to hot water stored in the upper part of the TES tank fully confirms the usefulness of the heat-flow models used.


  • Open Access

    Impact of Water Temperature Changes on Water Loss Monitoring in Large District Heating Systems

    by Olgierd Niemyjski, Ryszard Zwierzchowski

    This paper explores how water temperature changes in a district heating system (DHS) impact the monitoring of water losses. Water volume in DHS is constantly monitored, recorded, and replenished. The leakage and failure status of the DHS is often monitored through measuring the make-up water flow rate. In this paper, we present the methodology and a simplified model of the dynamics of the heating system operation, which was used to determine the profile of changes in the average temperature and density of water in the system. The mathematical model of the district heating network (DHN) was verified by comparing the results of simulation calculations, i.e., calculated values of the temperature of water returning to the heat source, with the measured values. Fluctuations in water temperature cause changes in the density and volume of water in the DHN, which affect the amount of water supplementing the system. This is particularly noticeable in a DHN with a large water volume. The study reports an analysis of measurement results of operating parameters of a major DHS in Poland (city of Szczecin). Hourly measurements were made of supply and return water temperature, water flow rate, and pressure throughout the whole of 2019. The water volume of the analyzed DHN is almost 42,000 m3 and the changes in water volume per hour are as high as 5 m3/h, representing 20–30% of the value of the make-up water flow rate. The analysis showed that systems for monitoring the tightness of the DHS and detecting failures, on the basis of measurements of the make-up water flow rate, should take into account the dynamics of water volume changes in the DHN.


  • Open Access

    Simulation of Heat Losses of a Distribution Network with Different Technical Structure and Under Different Operating Conditions for a District Heating and Cooling System

    by Ryszard Zwierzchowski, Olgierd Niemyjski

    The paper presents a simulation of heat losses of a distribution network with different technical structure and under different operating conditions for a District Heating and Cooling (DHC) system. The DHC system consists of a Combined Heat and Power (CHP) plant and a Distribution Network (DN) with chambers and heat and cold substations. The different operating conditions of the DHC systems result in the DNs having variable transportation losses. The result of the analysis was used to verify the models and calculation methods of the fluid flow and heat losses in the DN, when cold is generated using either absorption or adsorption chillers. Different technical structure of a DN means a system of connected underground and aboveground piping with different diameters. DNs in Poland are usually installed as an underground, traditionally insulated piping placed in the concrete ducts (large diameter main pipelines) or a pre-insulated piping placed directly in the ground. The total heat losses of the DN differ according to the individual systems and depend on the size of the DHC system, its heating loads and quality of insulation of the piping. This paper presents the results of the numerical calculation of the temperature distribution in the soil around the piping channel using an FDA model. These results were utilized for numerical simulation of the water and heat flow through the DN and calculation of heat transportation losses. The numerical simulation of heat losses was performed for the particular system of connected underground and aboveground piping with different diameters. Finally, the heat transportation losses of the DN were calculated and compared for analyzed District Heating (DH) system i.e. without cold consumers and for the DHC system, when cold for consumers is generated using either the absorption or the adsorption chillers.


  • Systemy Informacji Geograficznej - GIS wykorzystywane w przedsiębiorstwach ciepłowniczych

    by Olgierd Niemyjski

    Wydawnictwo SIGMA-NOT wydaje czasopisma fachowe informuj?ce swoich czytelnik?w o najnowszych osi?gni?ciach naukowych i nowoczesnych rozwi?zaniach technicznych w Polsce i na ?wiecie, popularyzuje problemy techniczne oraz poszerza wiedz? i kultur? techniczn?.

  • Open Access

    Influence of Different Operating Conditions of a District Heating and Cooling System on Heat Transportation Losses of a District Heating Network

    by Ryszard Zwierzchowski, Olgierd Niemyjski

    This paper deals with different operating conditions of a District Heating and Cooling (DHC) System and its influence on heat transportation losses of a District Heating Network (DHN). The different operating conditions of the DHC System's mean different flow rate and temperature of the network water flowing in the DHN. These different operating conditions of the DHC System result in the DHNs having variable transportation losses. The analyzed DHC System consists of the Heat Only Boilers (HOB) plant and the DHN with substations and chambers. The DHNs in Poland are usually installed as underground, traditionally insulated piping placed in concrete ducts (large diameter and main pipelines) or pre-insulated piping placed directly in the ground. The result of the analysis was used to verify calculation methods of fluid flow and heat transportation losses of the DHN, when cold for consumers is generated using either absorption or adsorption chillers. The total heat transportation losses of the DHN differ according to individual systems and depend on the size of the DHC System, its heating loads and quality of insulation of the piping. This paper presents the results of the numerical calculation of the temperature distribution in the soil around the piping channel using an FDA model. The results of the numerical simulation of water and heat flow through the DHN allow to determine the total heat transportation losses of the DHN for different operating conditions of the DHC System.