JCJuan José Legarra Calderón

Juan José Legarra Calderón

*This is an algorithmically generated author record based on publicly available information.

Juan José Legarra Calderón has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Contemporary evidence of long-term follow-up of the EpicTM prosthesis after mitral valve replacement

    by Beatriz Acuña Pais, Daniel Otero Lozano, Consuelo María Sisinni Ganly, Carolina Mayor Deniz, Rocío Casais Pampín, Juan José Legarra Calderón

    Introduction: To verify the long-term durability, freedom from reoperation and mortality of Biocor and Epic bioprosthesis in mitral position. Methods: The use of biological prostheses in mitral valve replacement surgery is widespread. Advances in transcatheter techniques have increased the utilisation of these biological substitutes, rendering the study of their durability once again pertinent. Biocor and Epic are two stented tissue valves with porcine leaflets indicated for patients requiring replacement of a diseased mitral or aortic heart valve. Long-term follow-up data were collected and analysed by age group and by type of surgery. Between 2000 and 2010, 244 patients underwent mitral or double valve replacement with a Biocor or Epic bioprosthesis at our institution. The median follow-up was 9 years (IQR: 0.01- 17.9). Complete follow-up was achieved in 98.4%. Results: The survival rates at 1, 5 and 10-years were 90, 73.7 and 43 %, respectively. Freedom from prothesis reintervention from any cause at 1, 5 and 10 years was 98.5, 92.8 and 90%. Freedom from structural valve deterioration by age group at 1, 5 and 10 years was as follows: age<60: 100, 84.6 and 47.6; age 60-69: 100, 94.1 and 94.1; and age≥70: 99.4, 98.7 and 96.5% respectively. Conclusion: Our 10-year freedom from structural valve deterioration of 93.1% matches, and may even surpass those previously reported. The Epic porcine xenograft in mitral position has demonstrated to have excellent durability and long-term outcomes; representing an excellent option for patients in need for mitral valve replacement.

  • Open Access

    Surgical Aortic Valve Replacement: Current Status and Future Perspectives in the Era of Catheter-Based Therapies

    by Francisco Estévez Cid, Carolina Mayor Déniz, Elio Martín Gutiérrez, Juan José Legarra Calderón

    Aortic stenosis (AS) is the most prevalent valvular heart disease in the developed world. Over the past two decades, the treatment of AS has undergone a profound transformation with the introduction of transcatheter aortic valve replacement (TAVR). TAVR has evolved from being an alternative treatment for patients with a prohibitive risk for surgical aortic valve replacement (SAVR), to becoming the first-line therapy for low-surgical-risk patients over 75 years old. Recent data have shown a significant increase in TAVR procedures compared to SAVR, surpassing both isolated SAVR and all SAVR interventions in most registries worldwide. Nevertheless, SAVR remains a key option in clinical practice, especially for younger patients with a longer life expectancy, patients with a complex aortic anatomy unsuitable for TAVR, and patients needing additional surgical interventions. The aim of this review was to examine the current state and future perspectives of SAVR in the expanding era of transcatheter therapies. While TAVR is expected to expand further, SAVR will likely continue to play an important role in some clinical scenarios. A multidisciplinary approach by a “Heart Team” that considers specific clinical and anatomical factors is crucial for ensuring the best long-term outcome for each patient.


  • Usefulness of Self-Expanding Drainage Cannula in Venovenous Extracorporeal Membrane Oxygenation: Tips, Tricks, and Results of an Early Experience

    by Miguel Piñón, Javier Suárez, Beatriz Acuña, Narda Ajhuacho, Consuelo Sisinni, Jorge Pereira, Juan Ignacio Chico, Sergio Raposeiras, Juan José Legarra

    Inadequate venous drainage decreases the efficiency of extracorporeal membrane oxygenation (ECMO). Pump augmentation may even make it worse due to collapse of the venous system under negative pressures. Furthermore, recirculation is a phenomenon that occurs when oxygenated blood supplied through the infusion cannula is withdrawn directly through the drainage cannula without contributing to the oxygenation of the patient and also compromises the efficacy of the therapy. Large drainage cannulas allow for similar flow rates at lower pump speed. But percutaneous insertion of these larger cannulas could be challenging. When using a self-expandable cannula, the diameter of the cannula for the insertion can be reduced, and once inserted, its intravascular diameter maximized, resulting in a large venous cannula due to in situ expansion after mandrel removal (up to 36F). We present a retrospective series of selfexpanding venous cannula 430 or 530 mm in length in six consecutive patients undergoing venovenous (VV) ECMO. No vascular or cardiac iatrogenic injury was caused during implantation. Target flows were reached, and no clinically significant recirculation was described in any case. The use of selfexpanding drainage cannulas was safe, and efficient drainage was achieved with easy and definitive unique positioning during cannulation.