    Contemporary evidence of long-term follow-up of the EpicTM prosthesis after mitral valve replacement

    by Beatriz Acuña Pais, Daniel Otero Lozano, Consuelo María Sisinni Ganly, Carolina Mayor Deniz, Rocío Casais Pampín, Juan José Legarra Calderón

    Introduction: To verify the long-term durability, freedom from reoperation and mortality of Biocor and Epic bioprosthesis in mitral position. Methods: The use of biological prostheses in mitral valve replacement surgery is widespread. Advances in transcatheter techniques have increased the utilisation of these biological substitutes, rendering the study of their durability once again pertinent. Biocor and Epic are two stented tissue valves with porcine leaflets indicated for patients requiring replacement of a diseased mitral or aortic heart valve. Long-term follow-up data were collected and analysed by age group and by type of surgery. Between 2000 and 2010, 244 patients underwent mitral or double valve replacement with a Biocor or Epic bioprosthesis at our institution. The median follow-up was 9 years (IQR: 0.01- 17.9). Complete follow-up was achieved in 98.4%. Results: The survival rates at 1, 5 and 10-years were 90, 73.7 and 43 %, respectively. Freedom from prothesis reintervention from any cause at 1, 5 and 10 years was 98.5, 92.8 and 90%. Freedom from structural valve deterioration by age group at 1, 5 and 10 years was as follows: age<60: 100, 84.6 and 47.6; age 60-69: 100, 94.1 and 94.1; and age≥70: 99.4, 98.7 and 96.5% respectively. Conclusion: Our 10-year freedom from structural valve deterioration of 93.1% matches, and may even surpass those previously reported. The Epic porcine xenograft in mitral position has demonstrated to have excellent durability and long-term outcomes; representing an excellent option for patients in need for mitral valve replacement.

  • Open Access

    Surgical management of tumor thrombus into the right atrium

    by Beatriz Acuña Pais, Rocío Casais, Julio Lugo, Miguel Á. Piñón, Juan. J. Legarra

    Renal cell carcinoma represents 3% of solid tumors. In 4-10% of patients, venous tumor thrombosis is present, and 1% reaches the right atrium. Other tumors can be associated with tumor thrombosis. The natural history of venous tumor thrombosis implies a mean survival of 5 months. Between 2001 and 2021, 4 patients underwent resection of tumor thrombi into the right atrium, requiring cardiopulmonary bypass. None of the patients died within 30 days postoperatively. Mean follow-up time was 30.9 months (2.4- 96.1). Two patients are still alive and two died due to disease progression. Died patient’s follow-up was 7.5 and 17.4 months, surpassing life expectancy of those without surgery. We present a series of patients who underwent lumpectomy and IVC thrombectomy. IVC tumor thrombosis has an ominous prognosis, however surgical treatment has an important role by improving the survival of these patients. The multidisciplinary approach is necessary to obtain good postoperative results.


  • Intraoperative prophylactic right ventricular assist device in prevention of postcardiotomy failure

    by Beatriz Acuña Pais, María Á Varela Martínez, Rocío Casais Pampín, Rafael Pita-Romero Caamaño, Juan J Legarra Calderón

    Objectives: In patients at risk of developing right ventricular failure after cardiac surgery, right ventricular support with a ventricular assist device may be a promising strategy to reduce mortality. We present our experience with intraoperative right ventricular assist device implantation as a prevention strategy of right ventricular failure after cardiac surgery. Methods: Between 2016 and 2022, we implanted four right ventricular assist devices prophylactically in a series of patients with surgical indication for valvular heart disease and high risk of postoperative right ventricular failure. Indications for the right ventricular assist device were suprasystemic pulmonary hypertension or severe right ventricular dysfunction. Results: Externalization of the device cannulas through intercostal spaces was performed in three patients, allowing early mobilization and withdrawal without resternotomy. Removal of the device ocurred on the eighth postoperative day. ICU and hospital length of stay was 12 (±1.6) and 23 days (±4.2) respectively. Hospital mortality was null. No patient died during follow-up, mean follow-up was 32.5 months [1–72]. Patients improved their NYHA functional class up to grade II during follow-up. Conclusions: Acute right ventricular failure after cardiac surgery remains a significant cause of morbidity and mortality. Prophylactic strategies to prevent postoperative right ventricular dysfunction may decrease the incidence of refractory postoperative right ventricular failure. We propose a novel approach to prevent right failure after cardiac surgery with prophylactic intraoperative ventricular assist device implantation.


  • Usefulness of Self-Expanding Drainage Cannula in Venovenous Extracorporeal Membrane Oxygenation: Tips, Tricks, and Results of an Early Experience

    by Miguel Piñón, Javier Suárez, Beatriz Acuña, Narda Ajhuacho, Consuelo Sisinni, Jorge Pereira, Juan Ignacio Chico, Sergio Raposeiras, Juan José Legarra

    Inadequate venous drainage decreases the efficiency of extracorporeal membrane oxygenation (ECMO). Pump augmentation may even make it worse due to collapse of the venous system under negative pressures. Furthermore, recirculation is a phenomenon that occurs when oxygenated blood supplied through the infusion cannula is withdrawn directly through the drainage cannula without contributing to the oxygenation of the patient and also compromises the efficacy of the therapy. Large drainage cannulas allow for similar flow rates at lower pump speed. But percutaneous insertion of these larger cannulas could be challenging. When using a self-expandable cannula, the diameter of the cannula for the insertion can be reduced, and once inserted, its intravascular diameter maximized, resulting in a large venous cannula due to in situ expansion after mandrel removal (up to 36F). We present a retrospective series of selfexpanding venous cannula 430 or 530 mm in length in six consecutive patients undergoing venovenous (VV) ECMO. No vascular or cardiac iatrogenic injury was caused during implantation. Target flows were reached, and no clinically significant recirculation was described in any case. The use of selfexpanding drainage cannulas was safe, and efficient drainage was achieved with easy and definitive unique positioning during cannulation.