CGConsuelo María Sisinni Ganly

Consuelo María Sisinni Ganly

*This is an algorithmically generated author record based on publicly available information.

Consuelo María Sisinni Ganly has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Contemporary evidence of long-term follow-up of the EpicTM prosthesis after mitral valve replacement

    by Beatriz Acuña Pais, Daniel Otero Lozano, Consuelo María Sisinni Ganly, Carolina Mayor Deniz, Rocío Casais Pampín, Juan José Legarra Calderón

    Introduction: To verify the long-term durability, freedom from reoperation and mortality of Biocor and Epic bioprosthesis in mitral position. Methods: The use of biological prostheses in mitral valve replacement surgery is widespread. Advances in transcatheter techniques have increased the utilisation of these biological substitutes, rendering the study of their durability once again pertinent. Biocor and Epic are two stented tissue valves with porcine leaflets indicated for patients requiring replacement of a diseased mitral or aortic heart valve. Long-term follow-up data were collected and analysed by age group and by type of surgery. Between 2000 and 2010, 244 patients underwent mitral or double valve replacement with a Biocor or Epic bioprosthesis at our institution. The median follow-up was 9 years (IQR: 0.01- 17.9). Complete follow-up was achieved in 98.4%. Results: The survival rates at 1, 5 and 10-years were 90, 73.7 and 43 %, respectively. Freedom from prothesis reintervention from any cause at 1, 5 and 10 years was 98.5, 92.8 and 90%. Freedom from structural valve deterioration by age group at 1, 5 and 10 years was as follows: age<60: 100, 84.6 and 47.6; age 60-69: 100, 94.1 and 94.1; and age≥70: 99.4, 98.7 and 96.5% respectively. Conclusion: Our 10-year freedom from structural valve deterioration of 93.1% matches, and may even surpass those previously reported. The Epic porcine xenograft in mitral position has demonstrated to have excellent durability and long-term outcomes; representing an excellent option for patients in need for mitral valve replacement.

  • Usefulness of Self-Expanding Drainage Cannula in Venovenous Extracorporeal Membrane Oxygenation: Tips, Tricks, and Results of an Early Experience

    by Miguel Piñón, Javier Suárez, Beatriz Acuña, Narda Ajhuacho, Consuelo Sisinni, Jorge Pereira, Juan Ignacio Chico, Sergio Raposeiras, Juan José Legarra

    Inadequate venous drainage decreases the efficiency of extracorporeal membrane oxygenation (ECMO). Pump augmentation may even make it worse due to collapse of the venous system under negative pressures. Furthermore, recirculation is a phenomenon that occurs when oxygenated blood supplied through the infusion cannula is withdrawn directly through the drainage cannula without contributing to the oxygenation of the patient and also compromises the efficacy of the therapy. Large drainage cannulas allow for similar flow rates at lower pump speed. But percutaneous insertion of these larger cannulas could be challenging. When using a self-expandable cannula, the diameter of the cannula for the insertion can be reduced, and once inserted, its intravascular diameter maximized, resulting in a large venous cannula due to in situ expansion after mandrel removal (up to 36F). We present a retrospective series of selfexpanding venous cannula 430 or 530 mm in length in six consecutive patients undergoing venovenous (VV) ECMO. No vascular or cardiac iatrogenic injury was caused during implantation. Target flows were reached, and no clinically significant recirculation was described in any case. The use of selfexpanding drainage cannulas was safe, and efficient drainage was achieved with easy and definitive unique positioning during cannulation.