AKAnatoliy I. Kupchishin

Anatoliy I. Kupchishin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Anatoliy I. Kupchishin has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reactive Magnetron-Sputtered Tantalum–Copper Nitride Coatings: Structure, Electrical Anisotropy, and Antibacterial Behavior

    by Paweł Żukowski, Vitalii Bondariev, Anatoliy I. Kupchishin, Marat N. Niyazov, Kairat B. Tlebaev, Yaroslav Bobitski, Joanna Kisała, Joanna Wojtas, Anna Żaczek, Štefan Hardoň, et al.

    Tantalum nitride (TaN) coatings are valued for their hardness, chemical inertness, and biocompatibility; however, they lack intrinsic antibacterial properties, which limits their application in biomedical environments. Introducing copper (Cu) into the TaN matrix offers a potential solution by combining TaN’s mechanical and chemical durability with Cu’s well-documented antimicrobial action. This study explores how varying copper incorporation affects the structural, electrical, photocatalytic, and antibacterial characteristics of TaCuN multilayer films synthesized via reactive magnetron sputtering. Three thin TaCuN films were fabricated using a high-power reactive magnetron co-sputtering system, varying the Cu target power to control the composition. Structural and morphological analysis was performed using X-ray diffraction (XRD), scanning/transmission electron microscopy (STEM/TEM), and energy-dispersive X-ray spectroscopy (EDS). Electrical conductivity was studied along and across the film surfaces at temperatures ranging from 20 to 375 K using AC impedance spectroscopy. Optical and photocatalytic properties were assessed using UV–Vis spectroscopy and methylene blue degradation tests. Antibacterial activity against Staphylococcus aureus was analyzed under visible light using CFU reduction tests. XRD and TEM analyses revealed a multilayered four-zone architecture with alternating Ta-, Cu-, and N-rich phases and a dominant cubic δ-TaN pattern. The layers exhibited pronounced conductivity anisotropy, with in-plane conductivity (~103 Ω−1 cm−1) exceeding cross-plane conductivity by ~107 times, attributed to the formation of a metallic conduction channel in the mid-layer. Optical spectra indicated limited light absorption above 300 nm and negligible photocatalytic activity. Increasing the Cu content substantially enhanced antibacterial efficiency, with the highest-Cu sample achieving 95.6 % bacterial growth reduction. Morphological evaluation indicated that smooth film surfaces (Ra < 0.2 μm) effectively minimized bacterial adhesion. Reactive magnetron sputtering enables the precise engineering of TaCuN multilayers, combining high electrical anisotropy with robust antibacterial functionality. The optimized TaCuN coating offers promising potential in biomedical and protective applications where both conductivity and microbial resistance are required.


  • Open Access

    Investigation of the Deformation Dependence of Polymer Films on Various Physical Factors

    by Anatoliy I. Kupchishin, Marat N. Niyazov, Sergey A. Ghyngazov

    In this work, models of the deformation behavior of polymer films of polyethylene and polyvinyl chloride are developed and analyzed, taking into account the influence of thickness, mechanical stress, temperature, time and dose of electron and ion irradiation. Experimental studies included tensile tests of polyethylene films of different thicknesses irradiated with krypton ions and electrons, as well as measuring the return deformation and its rate. It is shown that the quadratic and exponential models best describe the dependences of deformation on stress. Analytical formulas for the rate and acceleration of deformation are obtained, taking into account the influence of temperature and radiation dose. The results demonstrate a significant increase in the elastic properties and return deformation of irradiated samples, which is explained by the cross-linking of macromolecules and changes in the molecular structure under the influence of radiation. The proposed models and formulas can be effectively used in the development of devices and systems for monitoring the deformation of polymeric materials under radiation exposure in the aerospace, nuclear and electronic industries. Using the statistical analysis method, it was shown that the exponential model describes the dynamics of polyethylene deformation with a determination coefficient R2 = 0.985, which significantly exceeds the accuracy of the linear model (R2 = 0.85).


  • Open Access

    Investigation into Time-Dependent Deformation and Recovery Rates in Non-Irradiated and Irradiated Polymers

    by Anatoliy I. Kupchishin, Marat N. Niyazov, Sergey A. Ghyngazov

    The aim of this study was to investigate the effect of dose, temperature and mechanical stress on the return and rate of return deformation. The structure of the polymers under study begins to change under the influence of electron and ion beams, as well as temperature and mechanical stress, which leads to a change in such mechanical properties as return deformation and rate of return deformation. The authors proposed formulas for models that accurately explain the experimental data. In addition, using an optical microscope DM 6000M (Leica, Wetzlar, Germany), photographs of the surface morphology of unirradiated and irradiated materials before and after tensile testing were obtained. The results can be used to improve the properties of packaging materials in the food industry.


  • Open Access

    Deformation of Polyethylene Subjected to Static and Nonstatic Stresses and Krypton Ions Irradiation

    by Anatoliy I. Kupchishin, Artem L. Kozlovsky, Marat N. Niyazov, Kairat B. Tlebaev, Oleksandr. V. Bondar, Alexander D. Pogrebnjak

    The dependence of polyethylene deformation on applied mechanical stress under varying load conditions and radiation doses was investigated experimentally. Obtained results reveal significant alterations in the mechanical properties of polyethylene following irradiation with krypton ions at doses of 1.5 × 106, 1.6 × 107, 5.0 × 108, and 1.0 × 109 ions/s. The stress–strain curves obtained for both the unirradiated and irradiated samples are numerically modeled using frameworks developed by the authors. The findings indicate that irradiation with krypton ions at an energy level of 147 MeV exerts a pronounced impact on the deformation and strength characteristics of polyethylene. Notably, increasing the radiation dose to 109 particles/s results in a 2.5-fold increase in the rate of mechanical stress. Furthermore, the degree of deformation distortions in molecular chains induced by high-energy Kr15+ ion irradiation has been quantified as a function of irradiation fluence. Increasing the irradiation fluence from 106 ion/cm2 to 107 ion/cm2 causes only minor variations in deformation distortions, which are attributed to the localized isolation of latent tracks and associated changes in electron density. A comparative analysis of the mechanical behavior of irradiated polymer materials further revealed differences between ion and electron irradiation effects. It was observed that Teflon films lose their plasticity after irradiation, whereas polyethylene films exhibit enhanced elongation and tearing performance at higher strain values relative to their non-irradiated counterparts. This behavior was consistently observed for films irradiated with both ions and electrons. However, an important distinction was identified: high-energy electron irradiation degrades the strength of polyethylene, whereas krypton ion irradiation at 147 MeV does not result in strength reduction.


  • Open Access

    Study of the dependence of relative elongation on mechanical stress of polyvinyl chloride films

    by А.и. Купчишин, М.н. Ниязов

    The dependence of relative elongation on mechanical stress in polyvinyl chloride samples of various widths and working lengths was experimentally studied. The purpose of the study was to study the dependence of deformation on mechanical stress of polyvinyl chloride films of various sizes (width and length). The scientific and practical significance of the work lies in the fact that the data can serve as the basis for future research. Polyvinyl chloride film with a thickness of 100 microns was chosen as the material under study. The film sheets were cut into strips 3, 5, 7, 10 mm wide using a special cutting device with adjustable sample cutting width and length. The working length of the samples was: 4, 5, 6, 7, 8 cm. The tests were carried out on a special tensile testing machine RU-50. This setup is designed to study the dependence of strain (relative elongation) ε on stress σ. Significant changes in the mechanical properties of the material were discovered depending on various geometric parameters. The data obtained are satisfactorily described by the authors' models. The value of this study lies in the fact that the results of the work, according to the authors, will serve as an incentive to improve the mechanical properties of the research object.

  • Open Access

    Comparative Measurements and Analysis of the Electrical Properties of Nanocomposites TixZr1−xC+α-Cy (0.0 ≤ x ≤ 1.0)

    by Paweł Żukowski, Piotr Gałaszkiewicz, Vitali Bondariev, Paweł Okal, Alexander Pogrebnjak, Anatolyi Kupchishin, Anatolyi Ruban, Maksym Pogorielov, Tomasz N. Kołtunowicz

    In this paper, the frequency-temperature dependence of the conductivity and dielectric permittivity of nc-TixZr1−xC+α-Cy (0.0 ≤ x ≤ 1.0) nanocomposites produced by dual-source magnetron sputtering was determined. The films produced are biphasic layers with an excess of amorphous carbon relative to the stoichiometric composition of TixZr1−xC. The matrix was amorphous carbon, and the dispersed phase was carbide nanoparticles. AC measurements were performed in the frequency range of 50 Hz–5 MHz at temperatures from 20 K to 373 K. It was found that both conductivity and permittivity relationships are determined by three tunneling mechanisms, differing in relaxation times. The maxima in the low- and high-frequency regions decrease with increasing temperature. The maximum in the mid-frequency region increases with increasing temperature. The low-frequency maximum is due to electron tunneling between the carbon films on the surface of the carbide nanoshells. The mid-frequency maximum is due to electron transitions between the nano size grains. The high-frequency maximum is associated with tunneling between the nano-grains and the carbon shells. It has been established that dipole relaxation occurs in the nanocomposites according to the Cole-Cole mechanism. The increase in static dielectric permittivity with increasing measurement temperature is indicative of a step polarisation mechanism. In the frequency region above 1 MHz, anomalous dispersion—an increase in permittivity with increasing frequency—was observed for all nanocomposite contents.


  • Kinetic Study of Lithium–Zinc Ferrite Synthesis under Electron Beam Heating Conditions

    by E. N. Lysenko, V. A. Vlasov, A. P. Surzhikov, A. I. Kupchishin

    In this paper, we consider the kinetic regularities of lithium–zinc ferrite synthesis under conditions of heating by a high-energy electron beam of mixtures of initial reagents Fe2O3–Li2CO3–ZnO of bulk density and pressed in a hydraulic press. Radiation-thermal synthesis of the samples was performed using an ILU-6 pulsed electron accelerator by heating them with a 2.4-MeV high-energy electron beam. The samples were heated to 600, 700, and 750°C and held at these temperatures for up to 120 min. For comparison with radiation-thermal synthesis, similar studies were carried out with traditional thermal annealing under the same conditions. An X-ray diffraction analysis of the synthesized samples was performed. The rate of ferrite formation was found to depend on both the heating method and the density of the mixture. Heating the mixture with an electron beam is shown to significantly accelerate the process of obtaining ferrite, which manifests itself in a decrease in the values of the kinetic parameters of the ferrite synthesis. An increase in the rate of ferrite formation under the effect of electrons is due to a significant decrease in the activation energy of the synthesis and a decrease in the pre-exponential factor in the temperature dependence.


  • Open Access

    STUDY OF THE MECHANICAL PROPERTIES OF INDUSTRIAL PLEXIGLAS TESTING FOR FLAT STRAIGHT BENDING

    by A.I. Kupchishin, V.M. Lisitsyn, M.N. Niyazov, D.S. Utepova

    The mechanical properties of industrial plexiglas (polymethylmethacrylate) of various sizes (lengths, widths) have been studied when tested for plane straight bending with one concentrated force in the middle of the sample. By a result of the experimental work, the relationship between deformation and stress was obtained. It is clearly shown in the work that the experimental curves substantially depend on the parameters of the starting materials and are satisfactorily described by a linear model. The slope of tangent (α) for the curves ranges from 0,32 to 0,62 %MPa-1. The dependence of a α on the length and width of the samples changes significantly. Moreover, the maximum deformation varies in the range of 50 – 60 %, which confirms the dependence of the deformation properties of the material on horizontal components, in particular, on the length of the sample. The tensile strength of the material also differs between specimens of different sizes.


  • Open Access

    Effect of electronic irradiation on the properties of polyethyleneterephthalate films of various producers

    by A I Kupchishin, B G Taipova, N N Gerasimenko, N A Voronova, At Abdukhairova

    Studies on the effect of electron irradiation on the properties of polyethylene terephthalate films of various brands have been carried out. An analysis of the results shows that the relative elongation of the Mylar-type film is ~ 70%, for PET ε it is 48%. According to the strength properties, Russian-made PET is more resistant to electronic effects and is destroyed at doses of 109 Gy, while the Mylar ones at 105 Gy. The calculation made according to the proposed models (exponential and generalized) is in satisfactory agreement with experimental data.

  • Open Access

    Investigation of the influence of radiation on the optical biomaterials characteristics of the storage lake Sorbulak

    by N A Voronova, A I Kupchishin, M N Niyazov, O V Esyrev, A T Abdukhairova

    The authors carried out the study on the effects of radiation on the optical characteristics of water solutions of Lake Sorbulak during the passage of laser radiation through them. The experimental data are well consistent with the theoretical calculations of the exponential model.