Hatem A. Darwish
Hatem A. Darwish has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Abdel-Maksoud I. Taalab
Electrical Engineering Department, Minoufiya University, Egypt, 32511 Shebin Elkom, Minoufiya, Egypt
4 shared publications - Mohamed A. Izzularab
Electrical Engineering Department, Minoufiya University, Egypt, 32511 Shebin Elkom, Minoufiya, Egypt
3 shared publications - Nagy I. Elkalashy
Electrical Engineering Department, Faculty of Engineering, Menoufia University
2 shared publications - Ayman E. Ibrahim
Mechanical and Electrical Department, Ministry of Water Resources and Irrigation, Cairo 3855402, Egypt
1 shared publication - Matti Lehtonen
Faculty of Electronics, Communications and Automation, Helsinki University of Technology, Espoo, Finland
1 shared publication - Matti Lehtonen
Helsinki Univ Technol, Espoo 02015, Finland
1 shared publication
Latest Publications
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Feature Extraction of High Impedance Arcing Faults in Compensated MV Networks. Part II: DWT-Based Analysis of Residual Components
Electrical faults due to leaning trees have been studied in [1]-[2] and it was found that the initial transients due to the associated arc reignitions are behavioral traits. These transients have been localized using the discrete wavelet transform (DWT). In this paper, these features are extracted from residual voltages using DWT. Therefore, the fault localization is carried out. The term for locating the faulty feeder is based on the polarity of a specific frequency band-power computed by multiplying the DWT detail coefficient of the residual voltage and current for each feeder. The performance of the proposed technique is getting better when the residual waveforms are utilized. Test cases provide evidence of the efficacy of the proposed technique.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Feature Extraction of High Impedance Arcing Faults in Compensated MV Networks. Part II: DWT-Based Analysis of Residual Components
Electrical faults due to leaning trees have been studied in [1]-[2] and it was found that the initial transients due to the associated arc reignitions are behavioral traits. These transients have been localized using the discrete wavelet transform (DWT). In this paper, these features are extracted from residual voltages using DWT. Therefore, the fault localization is carried out. The term for locating the faulty feeder is based on the polarity of a specific frequency band-power computed by multiplying the DWT detail coefficient of the residual voltage and current for each feeder. The performance of the proposed technique is getting better when the residual waveforms are utilized. Test cases provide evidence of the efficacy of the proposed technique.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Feature Extraction of High Impedance Arcing Faults in Compensated MV Networks. Part I: DWT-Based Analysis of Phase Quantities
In this paper, the initial transients in the electrical network due to arc reignitions associated with high impedance faults caused by leaning trees are extracted from phase voltages and currents. The discrete wavelet transform (DWT) is used for the fault feature extraction corresponding to band frequency 12.5- 6.25 kHz and therefore localizing this fault occurrence. The detection security is enhanced because the DWT is responded to a periodicity of the initial transients. A novel technique for the selectivity term of the faulty feeder is introduced. It is based on the power polarity, in which, this power is computed by multiplying the DWT detail coefficient of the current and voltage for each feeder. The fault due to a leaning tree occurring at different locations in an unearthed 20 kV network is simulated by ATP/EMTP and the arc model is implemented using the universal arc representation.
- 1 July 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Feature Extraction of High Impedance Arcing Faults in Compensated MV Networks. Part I: DWT-Based Analysis of Phase Quantities
In this paper, the initial transients in the electrical network due to arc reignitions associated with high impedance faults caused by leaning trees are extracted from phase voltages and currents. The discrete wavelet transform (DWT) is used for the fault feature extraction corresponding to band frequency 12.5- 6.25 kHz and therefore localizing this fault occurrence. The detection security is enhanced because the DWT is responded to a periodicity of the initial transients. A novel technique for the selectivity term of the faulty feeder is introduced. It is based on the power polarity, in which, this power is computed by multiplying the DWT detail coefficient of the current and voltage for each feeder. The fault due to a leaning tree occurring at different locations in an unearthed 20 kV network is simulated by ATP/EMTP and the arc model is implemented using the universal arc representation.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-7
DWT-Based Investigation of phase currents for Detecting High Impedance Faults Due to Leaning Trees in Unearthed MV Networks
In this paper, features of earth faults due to leaning trees are extracted from the network phase currents using the discrete wavelet transform (DWT). Due to the associated arc reignitions, the initial transients in the electrical network give behavioral traits. The detection security is also enhanced because the DWT is responded to a periodicity of the initial transients. The absolute sum of the DWT detail d3 coefficient corresponding to the frequency band 12.5-6.25 kHz is computed over one power cycle for each phase current of each feeder where the sampling frequency is 100 kHz. It is found that the faulty phase has the highest absolute sum when it is compared with the other healthy phases. Similarly, the absolute sum of the faulty feeder is the highest when the comparison is carried out with respect to other feeders. Therefore, two logic functions are suggested to determine the faulty phase and the faulty feeder. The fault due to a leaning tree occurring at different locations in an unearthed 20 kV network is simulated by ATP/EMTP and the arc model is implemented using the universal arc representation.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-7
DWT-Based Investigation of phase currents for Detecting High Impedance Faults Due to Leaning Trees in Unearthed MV Networks
In this paper, features of earth faults due to leaning trees are extracted from the network phase currents using the discrete wavelet transform (DWT). Due to the associated arc reignitions, the initial transients in the electrical network give behavioral traits. The detection security is also enhanced because the DWT is responded to a periodicity of the initial transients. The absolute sum of the DWT detail d3 coefficient corresponding to the frequency band 12.5-6.25 kHz is computed over one power cycle for each phase current of each feeder where the sampling frequency is 100 kHz. It is found that the faulty phase has the highest absolute sum when it is compared with the other healthy phases. Similarly, the absolute sum of the faulty feeder is the highest when the comparison is carried out with respect to other feeders. Therefore, two logic functions are suggested to determine the faulty phase and the faulty feeder. The fault due to a leaning tree occurring at different locations in an unearthed 20 kV network is simulated by ATP/EMTP and the arc model is implemented using the universal arc representation.
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (21635137) , 624-629
Generalized 1-D Gabor Transform Application to Power System Signal Analysis
In this paper, the generalized 1-D Gabor transformation and possibility of application to power system signal analysis are presented. An artificial neural network based algorithm is employed to compute the Gabor coefficients for further decomposition of the power system signals. The time-frequency resolution analysis for sinusoidal, DC decaying, sudden change and non-integer harmonic signals is carried out. Contribution of this transform to power system applications is evaluated through various simulation test cases and scenarios. Recommendations for increasing the value of Gabor transform to protection area are outlined
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1 (21635137) , 624-629
Generalized 1-D Gabor Transform Application to Power System Signal Analysis
In this paper, the generalized 1-D Gabor transformation and possibility of application to power system signal analysis are presented. An artificial neural network based algorithm is employed to compute the Gabor coefficients for further decomposition of the power system signals. The time-frequency resolution analysis for sinusoidal, DC decaying, sudden change and non-integer harmonic signals is carried out. Contribution of this transform to power system applications is evaluated through various simulation test cases and scenarios. Recommendations for increasing the value of Gabor transform to protection area are outlined