Matti Lehtonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matti Lehtonen has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Abdelsalam Elhaffar
Department of Electrical and Computer Engineering, College of Engineering, Sultan Qaboos University, Muscat, Oman
2 shared publications - Abdel-Maksoud I. Taalab
Electrical Engineering Department, Minoufiya University, Egypt, 32511 Shebin Elkom, Minoufiya, Egypt
1 shared publication - Hatem A. Darwish
Electrical Engineering Department, Minoufiya University, Egypt, 32511 Shebin Elkom, Minoufiya, Egypt
1 shared publication - Mohamed A. Izzularab
Electrical Engineering Department, Minoufiya University, Egypt, 32511 Shebin Elkom, Minoufiya, Egypt
1 shared publication - Nagy I. Elkalashy
Student, IEEE, Power Systems & High Voltage Engineering, Helsinki University of Technology (TKK), Finland.
1 shared publication Naser Tarhuni
Faculty of Electronics, Communications and Automation, Helsinki University of Technology, Espoo, Finland
1 shared publication
Latest Publications
- 30 October 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 16 (5) , 1404-1412
Probabilistic model for MV spark-gap characteristics with lightning induced overvoltage superimposed on AC voltage
In this paper, the breakdown probability of MV spark-gaps is modeled using the Gaussian distribution function under an impulse voltage test in accordance with the IEC 60060-1 standard. The model is presented in the form of the well-known Gaussian tail probability. Accordingly, a modified probabilistic model is introduced to study the effect of impulse voltage superimposed on the AC voltage on the breakdown probability of MV spark-gaps. The modified model is verified using experimental data, where the experimental setup is arranged to generate a range of impulse voltages superimposed on the ac voltages. The results show evidence of the efficacy of the proposed probabilistic model. Furthermore, the proposed model is used to evaluate single-phase, two-phase and three-phase spark-gap breakdown probabilities in the case of lightning induced overvoltages. Finally, these breakdown probabilities are used along with the simplified Rusck expression to evaluate the performance of MV overhead lines above a perfectly conducting ground under lightning-induced voltages using a statistical approach.
- 30 October 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 16 (5) , 1404-1412
Probabilistic model for MV spark-gap characteristics with lightning induced overvoltage superimposed on AC voltage
In this paper, the breakdown probability of MV spark-gaps is modeled using the Gaussian distribution function under an impulse voltage test in accordance with the IEC 60060-1 standard. The model is presented in the form of the well-known Gaussian tail probability. Accordingly, a modified probabilistic model is introduced to study the effect of impulse voltage superimposed on the AC voltage on the breakdown probability of MV spark-gaps. The modified model is verified using experimental data, where the experimental setup is arranged to generate a range of impulse voltages superimposed on the ac voltages. The results show evidence of the efficacy of the proposed probabilistic model. Furthermore, the proposed model is used to evaluate single-phase, two-phase and three-phase spark-gap breakdown probabilities in the case of lightning induced overvoltages. Finally, these breakdown probabilities are used along with the simplified Rusck expression to evaluate the performance of MV overhead lines above a perfectly conducting ground under lightning-induced voltages using a statistical approach.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1-6
High Frequency Current Transformer Modeling for Traveling Waves Detection
Current traveling waves are utilized to localize faults on transmission lines using conventional current transformers. This paper investigates high frequency characterization of the current transformer. The current transformer parameters at high frequencies are experimentally determined. They are obtained using frequency response measurements where the current transformer transfer function is calculated from measured impulse signals. Therefore its performance under transient conditions can be studied using different programs such as EMTP and MATLAB. The current transformer modeling and its experimental verifications show that there are good replicas of high frequency traveling waves over a suitable range for fault locators. The test results insure the CT applicability to traveling wave fault location.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1-6
High Frequency Current Transformer Modeling for Traveling Waves Detection
Current traveling waves are utilized to localize faults on transmission lines using conventional current transformers. This paper investigates high frequency characterization of the current transformer. The current transformer parameters at high frequencies are experimentally determined. They are obtained using frequency response measurements where the current transformer transfer function is calculated from measured impulse signals. Therefore its performance under transient conditions can be studied using different programs such as EMTP and MATLAB. The current transformer modeling and its experimental verifications show that there are good replicas of high frequency traveling waves over a suitable range for fault locators. The test results insure the CT applicability to traveling wave fault location.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-7
DWT-Based Investigation of phase currents for Detecting High Impedance Faults Due to Leaning Trees in Unearthed MV Networks
In this paper, features of earth faults due to leaning trees are extracted from the network phase currents using the discrete wavelet transform (DWT). Due to the associated arc reignitions, the initial transients in the electrical network give behavioral traits. The detection security is also enhanced because the DWT is responded to a periodicity of the initial transients. The absolute sum of the DWT detail d3 coefficient corresponding to the frequency band 12.5-6.25 kHz is computed over one power cycle for each phase current of each feeder where the sampling frequency is 100 kHz. It is found that the faulty phase has the highest absolute sum when it is compared with the other healthy phases. Similarly, the absolute sum of the faulty feeder is the highest when the comparison is carried out with respect to other feeders. Therefore, two logic functions are suggested to determine the faulty phase and the faulty feeder. The fault due to a leaning tree occurring at different locations in an unearthed 20 kV network is simulated by ATP/EMTP and the arc model is implemented using the universal arc representation.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-7
DWT-Based Investigation of phase currents for Detecting High Impedance Faults Due to Leaning Trees in Unearthed MV Networks
In this paper, features of earth faults due to leaning trees are extracted from the network phase currents using the discrete wavelet transform (DWT). Due to the associated arc reignitions, the initial transients in the electrical network give behavioral traits. The detection security is also enhanced because the DWT is responded to a periodicity of the initial transients. The absolute sum of the DWT detail d3 coefficient corresponding to the frequency band 12.5-6.25 kHz is computed over one power cycle for each phase current of each feeder where the sampling frequency is 100 kHz. It is found that the faulty phase has the highest absolute sum when it is compared with the other healthy phases. Similarly, the absolute sum of the faulty feeder is the highest when the comparison is carried out with respect to other feeders. Therefore, two logic functions are suggested to determine the faulty phase and the faulty feeder. The fault due to a leaning tree occurring at different locations in an unearthed 20 kV network is simulated by ATP/EMTP and the arc model is implemented using the universal arc representation.
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 158-162
Effect of Current Transformer Transient Models on the Detection of Traveling Waves
The practical implementation of traveling wave fault location depends on the transducer characteristics at high frequency transients as a result of faults and other disturbances In this paper, an experimental study of the current transformer parameters at high frequencies has been carried out. Transfer function has been investigated and calculated. CT parameters have been measured using different methods. The frequency response of the CT has been calculated over a wide range of frequency.
- 1 July 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 158-162
Effect of Current Transformer Transient Models on the Detection of Traveling Waves
The practical implementation of traveling wave fault location depends on the transducer characteristics at high frequency transients as a result of faults and other disturbances In this paper, an experimental study of the current transformer parameters at high frequencies has been carried out. Transfer function has been investigated and calculated. CT parameters have been measured using different methods. The frequency response of the CT has been calculated over a wide range of frequency.
- 1 September 1999
- Published by Wiley in European Transactions on Electrical Power
- Vol. 9 (5) , 285-291
Method for detection and location of very high resistive earth faults
A new method is presented for the detection and location of high resistive, permanent single‐phase earth faults in medium‐voltage (MV) distribution networks (20 kV). The systems considered are with unearthed or a compensated neutral and the fault resistances covered are in the range of 5 kΩ … 160 kΩ. The algorithms of the new method are based on the change of the neutral voltage and zero‐sequence currents, measured at the MV substation and also at the distribution line locations.
- 1 September 1999
- Published by Wiley in European Transactions on Electrical Power
- Vol. 9 (5) , 285-291
Method for detection and location of very high resistive earth faults
A new method is presented for the detection and location of high resistive, permanent single‐phase earth faults in medium‐voltage (MV) distribution networks (20 kV). The systems considered are with unearthed or a compensated neutral and the fault resistances covered are in the range of 5 kΩ … 160 kΩ. The algorithms of the new method are based on the change of the neutral voltage and zero‐sequence currents, measured at the MV substation and also at the distribution line locations.