Ali Davoudi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ali Davoudi has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Juri Jatskevich
Electrical and Computer Engineering Department, University of British Columbia, Vancouver, BC, Canada
6 shared publications - Patrick L. Chapman
Grainger Center for Electric Machinery and Electromechanics, University of Illinois at Urbana-Champaign, 1406 W. Green, Urbana, IL 61801
3 shared publications - Alireza Khaligh
Grainger Center for Electric Machinery and Electromechanics, University of Illinois at Urbana-Champaign, 1406 W. Green, Urbana, IL 61801
2 shared publications Patrick L. Chapman
Univ Illinois, Grainger Ctr Elect Machines & Electromech, Urbana, IL 61801 USA
2 shared publicationsAlireza Khaligh
Electric Power and Power Electronics Center, Illinois Institute of Technology, Chicago, IL 60616
1 shared publicationChris S. Edrington
1 shared publication
Latest Publications
- 11 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 63 (7) , 2998-3000
Guest Editorial Special Section on Advanced Modeling, Simulation, Control, and Optimization Paradigms for Vehicular Power Systems
- 11 September 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 63 (7) , 2998-3000
Guest Editorial Special Section on Advanced Modeling, Simulation, Control, and Optimization Paradigms for Vehicular Power Systems
- 1 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10482334,p. 259-263
Automated System Identification of Digitally-Controlled Multi-phase DC-DC Converters
Real-time system identification is desirable for designing a proper feedback controller in a practical system. Digital control provides the potential advantages of on-line programmability to apply adaptive control. The digital nature of the feedback signal facilitates the communication between the converter and the processing unit (e.g., microcontroller). These features of digital control make it possible to estimate the real-time system parameters by means of system identification in situ (in-place), and then design and configure the controller accordingly. In this paper, an automated system identification method for digitally-controlled multi-phase DC-DC converters is set forth. Fourier analysis is utilized because of the potential for closed-loop identification and high measurement signal-to-noise ratio. The phase loss and zero-order-hold due to digital control are considered. The identification results for single- and multi-phase DC-DC converters closely match those obtained from conventional network analyzer and models. The proposed method can be done by a stand-alone digital controller; therefore it eliminates the expense of external test equipment. The identification results can be used for controller configuration without pre-existing knowledge of the power stage parameters. This opens up a possibility of moving the determination of the loop compensation from a lab bench to a factory floor or even to an end customer's application.
- 1 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10482334,p. 259-263
Automated System Identification of Digitally-Controlled Multi-phase DC-DC Converters
Real-time system identification is desirable for designing a proper feedback controller in a practical system. Digital control provides the potential advantages of on-line programmability to apply adaptive control. The digital nature of the feedback signal facilitates the communication between the converter and the processing unit (e.g., microcontroller). These features of digital control make it possible to estimate the real-time system parameters by means of system identification in situ (in-place), and then design and configure the controller accordingly. In this paper, an automated system identification method for digitally-controlled multi-phase DC-DC converters is set forth. Fourier analysis is utilized because of the potential for closed-loop identification and high measurement signal-to-noise ratio. The phase loss and zero-order-hold due to digital control are considered. The identification results for single- and multi-phase DC-DC converters closely match those obtained from conventional network analyzer and models. The proposed method can be done by a stand-alone digital controller; therefore it eliminates the expense of external test equipment. The identification results can be used for controller configuration without pre-existing knowledge of the power stage parameters. This opens up a possibility of moving the determination of the loop compensation from a lab bench to a factory floor or even to an end customer's application.
- 17 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 55 (10) , 1021-1025
Computer-Aided Dynamic Characterization of Fourth-Order PWM DC–DC Converters
Average-value modeling of dc-dc converters has been an area of active research for many years. Developing accurate average-value models of higher order converters is further complicated by the presence of parasitics and waveform nonlinearity. This paper extends the numerical state-space averaging to the fourth-order capacitor-based switching stages. The proposed model takes into account conduction losses associated with switching-stage components and is seamlessly functional in all operational modes. The proposed model is validated with a hardware prototype and detailed simulation and is shown to accurately predict large-signal time-domain transients as well as small-signal frequency-domain characteristics.
- 17 October 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 55 (10) , 1021-1025
Computer-Aided Dynamic Characterization of Fourth-Order PWM DC–DC Converters
Average-value modeling of dc-dc converters has been an area of active research for many years. Developing accurate average-value models of higher order converters is further complicated by the presence of parasitics and waveform nonlinearity. This paper extends the numerical state-space averaging to the fourth-order capacitor-based switching stages. The proposed model takes into account conduction losses associated with switching-stage components and is seamlessly functional in all operational modes. The proposed model is validated with a hardware prototype and detailed simulation and is shown to accurately predict large-signal time-domain transients as well as small-signal frequency-domain characteristics.
- 12 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 22 (6) , 2410-2415
Averaged-Switch Modeling of Fourth-Order PWM DC–DC Converters Considering Conduction Losses in Discontinuous Mode
This manuscript addresses dynamic average-value modeling for fourth-order pulse-width modulation (PWM) DC-DC converters in discontinuous capacitor-voltage mode. Although significant literature is devoted to analysis of the inductor-based switching stage of second-order DC-DC converters in discontinuous current mode, much less has been published regarding the discontinuous voltage mode in the capacitor-based switching stage in fourth-order converters. Accurate average-value models are further complicated by the presence of non-ideality in the switching stage components. This manuscript presents a full-order average-value model for the capacitor-based switching stage, taking into account conduction losses according to the energy conservation principle. The proposed model is validated with a hardware prototype and detailed simulation and is shown to accurately predict large-signal time-domain transients as well as small-signal frequency-domain characteristics.
- 12 November 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 22 (6) , 2410-2415
Averaged-Switch Modeling of Fourth-Order PWM DC–DC Converters Considering Conduction Losses in Discontinuous Mode
This manuscript addresses dynamic average-value modeling for fourth-order pulse-width modulation (PWM) DC-DC converters in discontinuous capacitor-voltage mode. Although significant literature is devoted to analysis of the inductor-based switching stage of second-order DC-DC converters in discontinuous current mode, much less has been published regarding the discontinuous voltage mode in the capacitor-based switching stage in fourth-order converters. Accurate average-value models are further complicated by the presence of non-ideality in the switching stage components. This manuscript presents a full-order average-value model for the capacitor-based switching stage, taking into account conduction losses according to the energy conservation principle. The proposed model is validated with a hardware prototype and detailed simulation and is shown to accurately predict large-signal time-domain transients as well as small-signal frequency-domain characteristics.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 725-729
Low-Order Dynamic Magnetic Equivalent Circuits of Saturated Steel Laminations
Physics-based modeling of laminated magnetic devices accurately represents underlying dynamic characteristics. However, these models are hard to formulate, oversimplified with crude approximations, and computationally intensive. In this paper, a high-fidelity magnetic equivalent circuit of steel lamination is set forth based on geometrical and material data. The nonlinearity imposed by saturation is also considered. Automated linear and nonlinear order-reduction techniques are introduced to mathematically extract the essential system dynamics in the desired bandwidth, thus preserving both accuracy and computational efficiency. The resulting reduced-order system is validated with hardware measurements and full-order simulation in both time and frequency domains.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 725-729
Low-Order Dynamic Magnetic Equivalent Circuits of Saturated Steel Laminations
Physics-based modeling of laminated magnetic devices accurately represents underlying dynamic characteristics. However, these models are hard to formulate, oversimplified with crude approximations, and computationally intensive. In this paper, a high-fidelity magnetic equivalent circuit of steel lamination is set forth based on geometrical and material data. The nonlinearity imposed by saturation is also considered. Automated linear and nonlinear order-reduction techniques are introduced to mathematically extract the essential system dynamics in the desired bandwidth, thus preserving both accuracy and computational efficiency. The resulting reduced-order system is validated with hardware measurements and full-order simulation in both time and frequency domains.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19388756,p. 31-35
Realization of Parasitics in the Stability of Dc-Dc Converters Loaded by Constant-Power Loads in Discontinuous Conduction Mode
Constant power load (CPL) characteristics of tightly regulated dc-dc converters in multi-converter distributed power systems is equivalent to the dynamic negative impedance, destabilizing the dc bus and consequently the system. Various techniques have been developed to control ideal/lossless converters loaded by CPLs. Neglecting loss components simplifies the modeling and analysis. Loss components significantly enhance the stability of the cascaded converters. In this paper, effects of parasitics in behavior of dc-dc converters operating in discontinuous conduction mode (DCM) and loaded by CPLs are investigated. Design criteria are presented, which gives recommendations on the design of multi- converter dc power systems to avoid negative impedance instability. The proposed stable operation criteria are validated with hardware measurements and detailed simulation analyses.
- 1 September 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 19388756,p. 31-35
Realization of Parasitics in the Stability of Dc-Dc Converters Loaded by Constant-Power Loads in Discontinuous Conduction Mode
Constant power load (CPL) characteristics of tightly regulated dc-dc converters in multi-converter distributed power systems is equivalent to the dynamic negative impedance, destabilizing the dc bus and consequently the system. Various techniques have been developed to control ideal/lossless converters loaded by CPLs. Neglecting loss components simplifies the modeling and analysis. Loss components significantly enhance the stability of the cascaded converters. In this paper, effects of parasitics in behavior of dc-dc converters operating in discontinuous conduction mode (DCM) and loaded by CPLs are investigated. Design criteria are presented, which gives recommendations on the design of multi- converter dc power systems to avoid negative impedance instability. The proposed stable operation criteria are validated with hardware measurements and detailed simulation analyses.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02714302,p. 793-796
Computer-Aided Average-Value Modeling of Fourth-Order PWM DC-DC Converters
Average-value modeling of dc-dc converters has been an area of active research for many years. Developing accurate average-value models of higher-order converters is further complicated by the presence of parasitics and waveform nonlinearity. A recently proposed numerical approach has been shown to be effective in including the effect of parasitics for second-order inductor-based dc-dc converters. This paper extends the numerical state-space averaging to the fourth-order capacitor-based switching stages. The proposed model takes into account conduction losses associated with switching stage components and is seamlessly functional in all operational modes. The proposed model is validated with a hardware prototype and detailed simulation and is shown to accurately predict large-signal time-domain transients as well as small-signal frequency-domain characteristics.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02714302,p. 793-796
Computer-Aided Average-Value Modeling of Fourth-Order PWM DC-DC Converters
Average-value modeling of dc-dc converters has been an area of active research for many years. Developing accurate average-value models of higher-order converters is further complicated by the presence of parasitics and waveform nonlinearity. A recently proposed numerical approach has been shown to be effective in including the effect of parasitics for second-order inductor-based dc-dc converters. This paper extends the numerical state-space averaging to the fourth-order capacitor-based switching stages. The proposed model takes into account conduction losses associated with switching stage components and is seamlessly functional in all operational modes. The proposed model is validated with a hardware prototype and detailed simulation and is shown to accurately predict large-signal time-domain transients as well as small-signal frequency-domain characteristics.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02759306,p. 2135-2139
Computer-Aided Average-Value Modeling of Peak Current-Mode Controlled Dc-Dc Converters Considering Parasitics
Analytical average-value modeling of peak current-mode controlled dc-dc converters is challenging. It becomes further complicated when the parasitics and different operational modes are considered. This manuscript presents a straightforward, yet powerful, methodology that considers the true average of nonlinear waveforms and produces a fairly accurate large-signal transient model. The proposed numerically- constructed model is functional in all operational modes and is validated in large-signal transient studies and small-signal frequency-domain characterizations.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 02759306,p. 2135-2139
Computer-Aided Average-Value Modeling of Peak Current-Mode Controlled Dc-Dc Converters Considering Parasitics
Analytical average-value modeling of peak current-mode controlled dc-dc converters is challenging. It becomes further complicated when the parasitics and different operational modes are considered. This manuscript presents a straightforward, yet powerful, methodology that considers the true average of nonlinear waveforms and produces a fairly accurate large-signal transient model. The proposed numerically- constructed model is functional in all operational modes and is validated in large-signal transient studies and small-signal frequency-domain characterizations.