Kazuya Minamishima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kazuya Minamishima has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Yoshitake Yamada
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
2 shared publications - Akihisa Yamazaki
Office of Radiological Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
1 shared publication Koichi Sugisawa
Office of Radiation Technology, Keio University Hospital, Shinjuku, Japan
1 shared publicationMasahiro Jinzaki
Department of Radiology, Keio University School of Medicine, Tokyo, Japan
1 shared publication- Masahiro Jinzaki
Department of Radiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
1 shared publication - Shota Masuda
Office of Radiological Technology, Keio University Hospital, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
1 shared publication
Latest Publications
- 5 February 2022
- Published by Elsevier in European Journal of Radiology
- Vol. 149, 110198
Impact of noise reduction on radiation dose reduction potential of virtual monochromatic spectral images: Comparison of phantom images with conventional 120 kVp images using deep learning image reconstruction and hybrid iterative reconstruction
- 5 February 2022
- Published by Elsevier in European Journal of Radiology
- Vol. 149, 110198
Impact of noise reduction on radiation dose reduction potential of virtual monochromatic spectral images: Comparison of phantom images with conventional 120 kVp images using deep learning image reconstruction and hybrid iterative reconstruction
- Open Access
- 28 February 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (3) , 318-325
Quantitative and qualitative evaluation of hybrid iterative reconstruction, with and without noise power spectrum models: A phantom study
The purpose of this phantom study was to investigate the feasibility of dose reduction with hybrid iterative reconstruction, with and without a noise power spectrum (NPS) model, using both quantitative and qualitative evaluations. Standard dose (SD), three‐quarter dose (TQD), and half‐dose (HD) of radiation were used. Images were reconstructed with filtered back projection (FBP), adaptive iterative dose reduction 3D (AIDR 3D) (MILD, STR), and AIDR 3D enhanced (eAIDR 3D) (eMILD, eSTR). An NPS analysis, task‐based modulation transfer function (MTFtask) analysis, and comparisons of low‐contrast detectability and image texture were performed. Although the eAIDR 3D had a higher NPS value in the high‐frequency range and improved image texture and resolution as compared with AIDR 3D at the same radiation dose and iteration levels, it yielded higher noise than AIDR 3D. Additionally, although there was no statistically significant difference between SD‐FBP and the TQD series in the comparison of the mean area under the curve (AUC), the mean AUC was statistically significantly different between SD‐FBP and the HD series. NPS values in the high‐frequency range, 10% MTFtask values, low‐contrast detectability, and image textures of TQD‐eMILD were comparable to those of SD‐FBP. Our findings suggested that using eMILD can reduce the radiation dose by 25%, while potentially maintaining diagnostic performance, spatial resolution, and image texture; this could support selecting the appropriate protocol in a clinical setting.
- 28 February 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (3) , 318-325
Open AccessQuantitative and qualitative evaluation of hybrid iterative reconstruction, with and without noise power spectrum models: A phantom study
The purpose of this phantom study was to investigate the feasibility of dose reduction with hybrid iterative reconstruction, with and without a noise power spectrum (NPS) model, using both quantitative and qualitative evaluations. Standard dose (SD), three‐quarter dose (TQD), and half‐dose (HD) of radiation were used. Images were reconstructed with filtered back projection (FBP), adaptive iterative dose reduction 3D (AIDR 3D) (MILD, STR), and AIDR 3D enhanced (eAIDR 3D) (eMILD, eSTR). An NPS analysis, task‐based modulation transfer function (MTFtask) analysis, and comparisons of low‐contrast detectability and image texture were performed. Although the eAIDR 3D had a higher NPS value in the high‐frequency range and improved image texture and resolution as compared with AIDR 3D at the same radiation dose and iteration levels, it yielded higher noise than AIDR 3D. Additionally, although there was no statistically significant difference between SD‐FBP and the TQD series in the comparison of the mean area under the curve (AUC), the mean AUC was statistically significantly different between SD‐FBP and the HD series. NPS values in the high‐frequency range, 10% MTFtask values, low‐contrast detectability, and image textures of TQD‐eMILD were comparable to those of SD‐FBP. Our findings suggested that using eMILD can reduce the radiation dose by 25%, while potentially maintaining diagnostic performance, spatial resolution, and image texture; this could support selecting the appropriate protocol in a clinical setting.