    Modeling and Experimental Analysis of Low-Viscosity/High-Permeability Sealant Penetration Dynamics in Oil-Filled Submarine Cables

    by Zhao Zhang, Mingli Fu, Chang Cai, Linjie Zhao, Lei Jia, Baojun Hui, Shuai Hou, Ming Zhang

    Insulating oil leakage from oil-filled submarine cables compromised operational integrity and posed environmental risks. This study proposed a novel sealant-plugging repair technique that combines low-viscosity/high-permeability sealant permeation and high-viscosity/low-permeability sealant replacement and pressurization. The permeation process of the low-viscosity sealant, from the injection port to the outlet, was visualized using the Volume of Fluid (VOF) method. Analysis focused on: (1) sealant volume fraction in the sealing cavity; (2) sealant leakage volume fraction along the radial gaps at outlet 2; and (3) relative velocity of the permeating sealant along the radial gaps at outlet 2. Application of 0.4 MPa of sealant pressure achieved the key balance, characterized by: (i) Completed displacement of air from the sealing cavity; (ii) Full permeation of sealant into the gaps between the armored copper strip gaps and the radial gaps; (iii) Avoidance of the excessive sealant leakage flow observed at 0.5 MPa, promoting efficient sealant usage; (iv) A short time to reach permeation and leakage steady state. This study demonstrated the feasibility of the low-viscosity sealant penetration into both the gaps between the armored copper strips and the radial gaps under 0.4 MPa injection pressure. It provided theoretical and experimental guidance for this process within the sealant plugging repair technique.

  • Open Access

    Lightning Flashover Characteristic and Effective Protection Measures of 10 kV Distribution Line Network

    by Song Zhang, Xiaobin Xiao, Lei Jia, Huaifei Chen, Lu Qu, Chakhung Yeung, Yuxuan Ding, Yaping Du

    Among various failure causes, lightning overvoltage represents the most significant threat to overhead distribution lines, which serve as critical components in power systems. This study uses the hybrid partial element equivalent circuit (PEEC) multi-conductor transmission line (MTL) method to perform overvoltage simulations and investigate lightning risk distribution along distribution lines developed from a real 10 kV distribution networks in Guizhou, China. The results of the rocket-triggered lightning observation verify the accuracy of the hybrid method for direct lightning simulation. Combining the Monte Carlo method with the electro-geometric model (EGM), the impact of differential protection configurations on annual lightning flashover rates is analyzed. The results demonstrate that lightning strikes on phase wires generate high-magnitude overvoltages but with limited spatial influence, resulting in fewer pole flashovers. Conversely, strikes on poles produce lower overvoltage peaks but affect wider areas, leading to significantly more flashovers. Using annual flashover rates as the risk evaluation metric, the line topologies into high-risk, medium-risk, and other low-risk areas are classified. Targeting an annual flashover rate below 0.4 as the design objective, the configuration schemes of the arresters are progressively optimized. This risk-based approach provides an effective reference framework for differential protection design of distribution line safeguards.


  • Research on the Applicability of Multiconductor Transmission Line Method Under Fast Transient Pulse

    by Ruihan Qi, Yue Li, Song Zhang, Xiaobing Xiao, Yongxiang Cai, Lei Jia

  • Open Access

    The Calculation Method of the Floating Conductor Potential in the Ion Flow Field

    by Lei Liu, Minchuan Liao, Lei Jia, Bin Li, Wenxin Wan

    For bipolar DC transmission projects, when one pole conductor is charged and running normally, and the other pole conductor is in a standby state (including cold standby and hot standby), if the standby pole conductor is not grounded, a high charging potential will appear on the surface. On the one hand, it will affect the insulation coordination and protection setting of the DC system. On the other hand, it will also affect the ion current and synthetic electric field on the ground. This article studies the calculation method of the potential of suspended conductors in the presence of floating conductors in the ion flow field, establishes a calculation model based on the minimum absolute value of the space charge density on the surface of the conductor, and calculates and analyzes the distribution of ionizing current and synthetic electric field below the ground of high-voltage DC lines in the presence of suspended conductors. The distribution laws of ground field strength and ion current in single-circuit bipolar DC transmission lines are studied when one pole is suspended, the other is operated, and when one circuit is operated. One circuit is shut down in double-circuit DC transmission lines on the same tower. For practical engineering, on the one hand, it is possible to predict the potential of suspended conductors in the ion flow field and propose adjustment plans for protection settings, insulation coordination, etc., in advance. On the other hand, when considering abnormal operating conditions, the impact of ion flow fields on the ground electromagnetic environment can be reduced by changing the geometric architecture and line selection.

  • Open Access

    Novel Data Compression Algorithm for Transmission Line Condition Monitoring

    by Gang Liu, Lei Jia, Taishan Hu, Fangming Deng, Zheng Chen, Tong Sun, Yanchong Feng

    For the problem of data accumulation caused by massive sensor data in transmission line condition monitoring system, this paper analyzes the type and amount of data in the transmission line sensor network, compares the compression algorithms of wireless sensor network data at home and abroad, and proposes an efficient lossless compression algorithm suitable for sensor data in transmission line linear heterogeneous networks. The algorithm combines the wavelet compression algorithm and the neighborhood index sequence algorithm. It displays a fast operation speed and requires a small amount of calculation. It is suitable for battery powered wireless sensor network nodes. By combining wavelet correlation analysis and neighborhood index sequence coding, the compression algorithm proposed in this paper can achieve a high compression rate, has strong robustness to packet loss, has high compression performance, and can help to reduce network load and the packet loss rate. Simulation results show that the proposed method achieves a high compression rate in the compression of the transmission line parameter dataset, is superior to the existing data compression algorithms, and is suitable for the compression and transmission of transmission line condition monitoring data.


  • Open Access

    Partial Discharge Simulation of Air Gap Defects in Oil-Paper Insulation Paperboard of Converter Transformer under Different Ratios of AC–DC Combined Voltage

    by Bing Luo, Jian Wang, Dong Dai, Lei Jia, Licheng Li, Tingting Wang

    A converter transformer is important primary equipment in a DC transmission project. The voltage on the valve side winding is complex when the equipment is running, including DC, AC, and AC–DC combined voltage. The insulation structure of the valve side winding of a converter transformer is an oil-paper insulation structure, which may have a variety of defects in the manufacturing stage and daily use, resulting in partial discharge. Therefore, it is the key to studying the partial discharge characteristics and mechanism of oil-paper insulation under AC–DC combined voltage. In this paper, we build a two-dimensional air gap model of oil-paper-insulated pressboard considering the actual particles and actual reaction based on the fluid model. The characteristics and evolution mechanism of partial discharge (PD) in pressboard under different AC/DC combined voltages are studied by numerical simulation. The results show that when the DC component increases, the polarity effect of partial discharge is more obvious, while the potential and discharge intensity in the air gap decrease. Further analysis revealed that the DC component in the combined voltage accumulated a large number of surface charges on the surface of the air gap, and the space charge distribution was more uniform and dispersed, which generated an electric field with opposite polarity to the DC component in the air gap and, then, inhibited the development of local discharge in the paperboard. The results of the simulation are consistent with the previous experimental phenomena, and the mechanism analysis of the simulation results also verifies the previous analysis on the mechanism of experimental phenomena. This will lay a theoretical foundation for the further study of partial discharge phenomenon of oil-paper insulation structures in practical operation in the future.


  • Breakdown Characteristics of a 220-kV Composite Insulator String Under Short Tail Lightning Impulses Based on the Discharge Current and Images

    by Xiangen Zhao, Gang Liu, Lei Jia, Hansheng Cai, Bing Luo, Yi Zhang, Hongkun Chen, Junjia He

    There are two hypotheses in the leader progression model (LPM) to illustrate the insulator breakdown process. One is the streamer onset time is relatively small which can be ignored. The other is the leader velocity at both sides of the composite insulator strings are equal. These assumptions are mostly based on the experimental results in rod-rod air gaps. In this paper, experiments were performed to study the breakdown process of a 220-kV composite insulator string with grading rings under positive short tail lightning impulses. The discharge current at the high-voltage side and the high-speed photographs were recorded synchronously. The method of identifying four typical stages of the breakdown process from the current waveform was proposed. The experimental results show that the streamer onset time should not be ignored when calculating the breakdown time, especially for the composite insulator string with grading rings. By fitting the experimental results, the relationship between the streamer onset time and UP/U50 has been given. The results also indicate that the velocity of the positive leader is nearly 1.3 times than that of the negative leader during the breakdown process when the positive impulse is applied to the composite insulator string.


  • Open Access

    Flashover Performance Test with Lightning Impulse and Simulation Analysis of Different Insulators in a 110 kV Double-Circuit Transmission Tower

    by Yaqi Zhang, Licheng Li, Yongxia Han, Yaoxuan Ruan, Jie Yang, Hansheng Cai, Gang Liu, Yi Zhang, Lei Jia, Yutang Ma

    The flashover performance of insulators is the foundation of the calculation of precise lightning protection. The material and structure of an insulator affect its flashover performance but the research on the differences in the flashover performance of different insulators and the analysis of the reason for these differences have not been clear. In this paper, lightning impulse flashover tests of two types of insulators (composite and glass insulators) were carried out in the National Engineering Laboratory (Kunming) for Ultrahigh-voltage Engineering Technology. In these tests, the insulators were hung in a 110 kV double-circuit transmission tower and a standard lightning impulse (1.2/50 μs) was applied to the insulators. The discharge path and the 50% impulse flashover voltage of the insulators were recorded. At the same time, the electric fields in the vicinity of different insulators were calculated using the finite element method with COMSOL Multiphysics. The electric field distribution and the uneven coefficient were analyzed. Combined with the flashover test data and the electric field simulation, the relationship between the flashover performance (discharge path and 50% impulse flashover voltage) and the electric field (electric field distribution and uneven coefficient) is found. The simulation results are in accordance with the test data and the conclusions can provide useful references for the external insulation design of transmission lines and the optimization of insulators.