Gang Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gang Liu has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Hansheng Cai
Electric Power Research Institute, China Southern Power Grid, Guangzhou 510080, China
4 shared publications - Lei Jia
Power Research Institute, China Southern Power Grid, Guangzhou 510530, China
3 shared publications - Lu Qu
Power Research Institute, China Southern Power Grid, Guangzhou 510530, China
3 shared publications - Bing Luo
Electric Power Research Institute, China Southern Power Grid, United Laboratory of Advanced Electrical Materials and Equipment Support Technology, CSG
2 shared publications - Licheng Li
School of Electric Power, South China University of Technology, Guangzhou 510641, China
2 shared publications - Minchuan Liao
National Engineering Research Center of UHV Technology and New Electrical Equipment (NERCUHV&EE)
2 shared publications
Latest Publications
- Open Access
Study on the Failure Causes and Improvement Measures of Arresters in 10 kV Distribution Transformer Areas
In recent years, arresters in 10 kV distribution transformer areas of the Guangdong power grid have exhibited a rising trend of premature failures, posing a serious threat to distribution network reliability. This paper studied the failure causes of arresters through performance tests on failed arresters and through deterioration tests on new arresters and their prorated sections under typical operating stresses. The failed arresters and their internal varistors displayed varying degrees of physical damage and pronounced degradation in electrical performance, characterized by a strong polarity effect on the DC reference voltage (U1mA), elevated DC leakage current (IL) and resistive current (iR), and excessive residual voltage (U5kV). In the lightning impulse test, varistors primarily showed pinhole-type damage and significant polarity effects on ΔU1mA. In the AC aging test, ΔU5kV increased markedly. In the water immersion test, varistors exhibited salt deposits and aluminum electrode blackening, with ΔU1mA decreasing, while IL and ΔiR increased significantly. Overall, internal moisture superimposed on other operating stresses was identified as a major internal cause of arrester failure, while pollution flashover of the housing was considered the primary external factor. Corresponding improvement measures in material optimization, testing and inspection, and operation and maintenance are proposed to enhance arrester reliability.
Open AccessStudy on the Failure Causes and Improvement Measures of Arresters in 10 kV Distribution Transformer Areas
In recent years, arresters in 10 kV distribution transformer areas of the Guangdong power grid have exhibited a rising trend of premature failures, posing a serious threat to distribution network reliability. This paper studied the failure causes of arresters through performance tests on failed arresters and through deterioration tests on new arresters and their prorated sections under typical operating stresses. The failed arresters and their internal varistors displayed varying degrees of physical damage and pronounced degradation in electrical performance, characterized by a strong polarity effect on the DC reference voltage (U1mA), elevated DC leakage current (IL) and resistive current (iR), and excessive residual voltage (U5kV). In the lightning impulse test, varistors primarily showed pinhole-type damage and significant polarity effects on ΔU1mA. In the AC aging test, ΔU5kV increased markedly. In the water immersion test, varistors exhibited salt deposits and aluminum electrode blackening, with ΔU1mA decreasing, while IL and ΔiR increased significantly. Overall, internal moisture superimposed on other operating stresses was identified as a major internal cause of arrester failure, while pollution flashover of the housing was considered the primary external factor. Corresponding improvement measures in material optimization, testing and inspection, and operation and maintenance are proposed to enhance arrester reliability.
- Open Access
- 1 August 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (8) , 1217
Branching Morphology of Negative Leaders with Different Propagation Directions in Natural Lightning
Comparing the branching features of negative leaders with different propagation directions could provide insight into the common tendency of development pathways and the formation pattern of branches in natural lightning. This paper reports an upward negative leader (UNL) and a downward negative leader (DNL), and their branching features are analyzed and compared. The UNL is classified into vertical (UNL-V) and horizontal (UNL-H) segments based on propagation directions at different stages. The downward negative leader (DNL) is classified into main (DNL-M) and secondary (DNL-S) channels based on whether the channel is ultimately connected to the upward connecting leader. The vital angle parameters characterizing the branching morphology are investigated. For the strong branch eventually forming a section of the main channel, its deflection angle conforms to the lognormal distribution with a mean range of 22–36°. The included angle between the branches and the deflection angle of weak branches conform to the normal distribution with means close to 40° and 60°, respectively. Moreover, the velocity for four categories of negative leaders decreases noticeably by two or more branching behaviors in a frame interval of about 80 μs. In particular, similarities in branching morphology have been found in UNL-H, UNL-V, and DNL-S, with a semblable distribution in deflection and included angles. Statistical results indicate that branches of DNL-M tend to follow the previous direction of leader development, and the branching behavior has minimal impact on its velocity.
- 1 August 2022
- Published by MDPI AG in Atmosphere
- Vol. 13 (8) , 1217
Open AccessBranching Morphology of Negative Leaders with Different Propagation Directions in Natural Lightning
Comparing the branching features of negative leaders with different propagation directions could provide insight into the common tendency of development pathways and the formation pattern of branches in natural lightning. This paper reports an upward negative leader (UNL) and a downward negative leader (DNL), and their branching features are analyzed and compared. The UNL is classified into vertical (UNL-V) and horizontal (UNL-H) segments based on propagation directions at different stages. The downward negative leader (DNL) is classified into main (DNL-M) and secondary (DNL-S) channels based on whether the channel is ultimately connected to the upward connecting leader. The vital angle parameters characterizing the branching morphology are investigated. For the strong branch eventually forming a section of the main channel, its deflection angle conforms to the lognormal distribution with a mean range of 22–36°. The included angle between the branches and the deflection angle of weak branches conform to the normal distribution with means close to 40° and 60°, respectively. Moreover, the velocity for four categories of negative leaders decreases noticeably by two or more branching behaviors in a frame interval of about 80 μs. In particular, similarities in branching morphology have been found in UNL-H, UNL-V, and DNL-S, with a semblable distribution in deflection and included angles. Statistical results indicate that branches of DNL-M tend to follow the previous direction of leader development, and the branching behavior has minimal impact on its velocity.
- Open Access
Novel Data Compression Algorithm for Transmission Line Condition Monitoring
For the problem of data accumulation caused by massive sensor data in transmission line condition monitoring system, this paper analyzes the type and amount of data in the transmission line sensor network, compares the compression algorithms of wireless sensor network data at home and abroad, and proposes an efficient lossless compression algorithm suitable for sensor data in transmission line linear heterogeneous networks. The algorithm combines the wavelet compression algorithm and the neighborhood index sequence algorithm. It displays a fast operation speed and requires a small amount of calculation. It is suitable for battery powered wireless sensor network nodes. By combining wavelet correlation analysis and neighborhood index sequence coding, the compression algorithm proposed in this paper can achieve a high compression rate, has strong robustness to packet loss, has high compression performance, and can help to reduce network load and the packet loss rate. Simulation results show that the proposed method achieves a high compression rate in the compression of the transmission line parameter dataset, is superior to the existing data compression algorithms, and is suitable for the compression and transmission of transmission line condition monitoring data.
Open AccessNovel Data Compression Algorithm for Transmission Line Condition Monitoring
For the problem of data accumulation caused by massive sensor data in transmission line condition monitoring system, this paper analyzes the type and amount of data in the transmission line sensor network, compares the compression algorithms of wireless sensor network data at home and abroad, and proposes an efficient lossless compression algorithm suitable for sensor data in transmission line linear heterogeneous networks. The algorithm combines the wavelet compression algorithm and the neighborhood index sequence algorithm. It displays a fast operation speed and requires a small amount of calculation. It is suitable for battery powered wireless sensor network nodes. By combining wavelet correlation analysis and neighborhood index sequence coding, the compression algorithm proposed in this paper can achieve a high compression rate, has strong robustness to packet loss, has high compression performance, and can help to reduce network load and the packet loss rate. Simulation results show that the proposed method achieves a high compression rate in the compression of the transmission line parameter dataset, is superior to the existing data compression algorithms, and is suitable for the compression and transmission of transmission line condition monitoring data.
- Open Access
Simulation Study on Positive Corona Discharge of Receptors on Rotating Wind Turbine Blade Tips under Thundercloud Electric Fields
Recent lightning simulation experiments have not simulated the influence of blade rotation in the long term after corona inception. This study uses a finite element method and considers the adhesion and collision processes of positive ions, aerosol ions, and neutral particles to establish a two-dimensional positive corona discharge model based on a multicomponent diffusion transport equation. The microscopic distribution of these three types of particles and the influence mechanism of charged particles’ migration under electric fields and wind were studied. The results show that ion migration is affected by both electric field and wind speed. The higher the wind speed, the larger is the deviation amplitude of charged particles along the direction of wind. With an increase in wind speed, the corona current on the receptor surface gradually increases. When the wind speed is 30 m/s, the corona current peak value increases by almost six times when compared with that when no wind is present. From this, it can be inferred that blade rotation reduces the concentration of positive ion in the receptor area, thereby facilitating electron avalanche and streamer-leader conversion.
Open AccessSimulation Study on Positive Corona Discharge of Receptors on Rotating Wind Turbine Blade Tips under Thundercloud Electric Fields
Recent lightning simulation experiments have not simulated the influence of blade rotation in the long term after corona inception. This study uses a finite element method and considers the adhesion and collision processes of positive ions, aerosol ions, and neutral particles to establish a two-dimensional positive corona discharge model based on a multicomponent diffusion transport equation. The microscopic distribution of these three types of particles and the influence mechanism of charged particles’ migration under electric fields and wind were studied. The results show that ion migration is affected by both electric field and wind speed. The higher the wind speed, the larger is the deviation amplitude of charged particles along the direction of wind. With an increase in wind speed, the corona current on the receptor surface gradually increases. When the wind speed is 30 m/s, the corona current peak value increases by almost six times when compared with that when no wind is present. From this, it can be inferred that blade rotation reduces the concentration of positive ion in the receptor area, thereby facilitating electron avalanche and streamer-leader conversion.
- 8 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 3211-3217
Breakdown Characteristics of a 220-kV Composite Insulator String Under Short Tail Lightning Impulses Based on the Discharge Current and Images
There are two hypotheses in the leader progression model (LPM) to illustrate the insulator breakdown process. One is the streamer onset time is relatively small which can be ignored. The other is the leader velocity at both sides of the composite insulator strings are equal. These assumptions are mostly based on the experimental results in rod-rod air gaps. In this paper, experiments were performed to study the breakdown process of a 220-kV composite insulator string with grading rings under positive short tail lightning impulses. The discharge current at the high-voltage side and the high-speed photographs were recorded synchronously. The method of identifying four typical stages of the breakdown process from the current waveform was proposed. The experimental results show that the streamer onset time should not be ignored when calculating the breakdown time, especially for the composite insulator string with grading rings. By fitting the experimental results, the relationship between the streamer onset time and UP/U50 has been given. The results also indicate that the velocity of the positive leader is nearly 1.3 times than that of the negative leader during the breakdown process when the positive impulse is applied to the composite insulator string.
- 8 October 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 33 (6) , 3211-3217
Breakdown Characteristics of a 220-kV Composite Insulator String Under Short Tail Lightning Impulses Based on the Discharge Current and Images
There are two hypotheses in the leader progression model (LPM) to illustrate the insulator breakdown process. One is the streamer onset time is relatively small which can be ignored. The other is the leader velocity at both sides of the composite insulator strings are equal. These assumptions are mostly based on the experimental results in rod-rod air gaps. In this paper, experiments were performed to study the breakdown process of a 220-kV composite insulator string with grading rings under positive short tail lightning impulses. The discharge current at the high-voltage side and the high-speed photographs were recorded synchronously. The method of identifying four typical stages of the breakdown process from the current waveform was proposed. The experimental results show that the streamer onset time should not be ignored when calculating the breakdown time, especially for the composite insulator string with grading rings. By fitting the experimental results, the relationship between the streamer onset time and UP/U50 has been given. The results also indicate that the velocity of the positive leader is nearly 1.3 times than that of the negative leader during the breakdown process when the positive impulse is applied to the composite insulator string.
- Open Access
Flashover Performance Test with Lightning Impulse and Simulation Analysis of Different Insulators in a 110 kV Double-Circuit Transmission Tower
The flashover performance of insulators is the foundation of the calculation of precise lightning protection. The material and structure of an insulator affect its flashover performance but the research on the differences in the flashover performance of different insulators and the analysis of the reason for these differences have not been clear. In this paper, lightning impulse flashover tests of two types of insulators (composite and glass insulators) were carried out in the National Engineering Laboratory (Kunming) for Ultrahigh-voltage Engineering Technology. In these tests, the insulators were hung in a 110 kV double-circuit transmission tower and a standard lightning impulse (1.2/50 μs) was applied to the insulators. The discharge path and the 50% impulse flashover voltage of the insulators were recorded. At the same time, the electric fields in the vicinity of different insulators were calculated using the finite element method with COMSOL Multiphysics. The electric field distribution and the uneven coefficient were analyzed. Combined with the flashover test data and the electric field simulation, the relationship between the flashover performance (discharge path and 50% impulse flashover voltage) and the electric field (electric field distribution and uneven coefficient) is found. The simulation results are in accordance with the test data and the conclusions can provide useful references for the external insulation design of transmission lines and the optimization of insulators.
Open AccessFlashover Performance Test with Lightning Impulse and Simulation Analysis of Different Insulators in a 110 kV Double-Circuit Transmission Tower
The flashover performance of insulators is the foundation of the calculation of precise lightning protection. The material and structure of an insulator affect its flashover performance but the research on the differences in the flashover performance of different insulators and the analysis of the reason for these differences have not been clear. In this paper, lightning impulse flashover tests of two types of insulators (composite and glass insulators) were carried out in the National Engineering Laboratory (Kunming) for Ultrahigh-voltage Engineering Technology. In these tests, the insulators were hung in a 110 kV double-circuit transmission tower and a standard lightning impulse (1.2/50 μs) was applied to the insulators. The discharge path and the 50% impulse flashover voltage of the insulators were recorded. At the same time, the electric fields in the vicinity of different insulators were calculated using the finite element method with COMSOL Multiphysics. The electric field distribution and the uneven coefficient were analyzed. Combined with the flashover test data and the electric field simulation, the relationship between the flashover performance (discharge path and 50% impulse flashover voltage) and the electric field (electric field distribution and uneven coefficient) is found. The simulation results are in accordance with the test data and the conclusions can provide useful references for the external insulation design of transmission lines and the optimization of insulators.