Mikhail Pavlov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mikhail Pavlov has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Denis Karpov
Vologda State University
4 shared publications - Nikolay Monarkin
Vologda State University
2 shared publications A G Gudkov
Department of Heat, Gas and Water Supply, Vologda State University, 15, Lenina str., 160000, Vologda, Russian Federation
1 shared publicationA. G. Gudkov
Vologda State University
1 shared publication- Anton A. Sinitsyn
Вологодский государственный университет
1 shared publication Anton Mikhin
Peter the Great St. Petersburg Polytechnic University
1 shared publication
Latest Publications
- Open Access
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1079 (6) , 062041
Mass Transfer in a Layer of Aluminized Glass-Fiber Material in the Treatment of Chrome-Containing Wastewater
It is possible to use column-type devices with the loading of composite material - thin glass fibres partially coated with an aluminium layer (AGFM) to purify low-concentrated wastewater on plating plant containing chromium compounds. The main physical characteristics of this material are given. For the mass transfer research, current-potential curves obtained by reducing the chromium forms Cr(VI) to trivalent on a thin copper yarn placed in a layer of aluminum-removed fiberglass were studied. Dependence of effective mass-transfer coefficient on solution flow rate is obtained. Taking into account the ionic strength of the solution, the diffusion coefficient of the reducing anion Cr(VI) was calculated, which allowed to move to the criterion equations of the form Nu = f (Pr, Re). Coefficients are found in the criteria mass-transfer equation at different degrees of filling of the filter volume with a AGFM material.
- 1 March 2021
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 1079 (6) , 062041
Open AccessMass Transfer in a Layer of Aluminized Glass-Fiber Material in the Treatment of Chrome-Containing Wastewater
It is possible to use column-type devices with the loading of composite material - thin glass fibres partially coated with an aluminium layer (AGFM) to purify low-concentrated wastewater on plating plant containing chromium compounds. The main physical characteristics of this material are given. For the mass transfer research, current-potential curves obtained by reducing the chromium forms Cr(VI) to trivalent on a thin copper yarn placed in a layer of aluminum-removed fiberglass were studied. Dependence of effective mass-transfer coefficient on solution flow rate is obtained. Taking into account the ionic strength of the solution, the diffusion coefficient of the reducing anion Cr(VI) was calculated, which allowed to move to the criterion equations of the form Nu = f (Pr, Re). Coefficients are found in the criteria mass-transfer equation at different degrees of filling of the filter volume with a AGFM material.
- 5 February 2021
- Published by Springer Nature
- p. 129-135
Study of the Influence of Various Factors on the Air Temperature in the Greenhouse with Radiant Heating
- 5 February 2021
- Published by Springer Nature
- p. 129-135
Study of the Influence of Various Factors on the Air Temperature in the Greenhouse with Radiant Heating
- Open Access
- 9 July 2020
- Published by EDP Sciences
- Vol. 178, 01004
Assessment of energy efficiency of application heat-insulating paint for the needs of district heat supply systems
Energy conservation is a priority for most of the nation states. Its relevance in modern world energy industry is growing every year. This problem acquires particular importance when a country is characterized by a lack of fuel and energy resources or adverse climatic conditions. The most effective way to reduce heat losses from heat network pipelines to environment is the use of heat insulation. This paper presents the results of application heat-insulating paint on the surface of main pipeline. The infrared thermometry devices (pyrometer and thermal imager) were used to evaluate the energy efficiency of modern high-tech insulation. The thermograms from thermal imager and the readings from pyrometer were analyzed, it was established that the absolute difference in temperatures of an isolated pipeline section and an unpainted section are 5-10 °C. The studies have also shown that when a 250×6 pipeline is coated with a 1 mm thick heat-insulating paint, it will save 126.1 m3 of natural gas per 1 running meter per year. In monetary terms it will be approximately 610 rubles or about $9 (for the first half of 2020). The payback period of this energy-saving measure should not exceed six months. Increasing the thickness of liquid heat insulation layer is not economically feasible. The equivalent fuel economy is approximately 65% when the heat-insulating paint is of 1 mm thickness, and it will increase by only 8% for a thickness of 1.5 mm.
- 9 July 2020
- Published by EDP Sciences
- Vol. 178, 01004
Open AccessAssessment of energy efficiency of application heat-insulating paint for the needs of district heat supply systems
Energy conservation is a priority for most of the nation states. Its relevance in modern world energy industry is growing every year. This problem acquires particular importance when a country is characterized by a lack of fuel and energy resources or adverse climatic conditions. The most effective way to reduce heat losses from heat network pipelines to environment is the use of heat insulation. This paper presents the results of application heat-insulating paint on the surface of main pipeline. The infrared thermometry devices (pyrometer and thermal imager) were used to evaluate the energy efficiency of modern high-tech insulation. The thermograms from thermal imager and the readings from pyrometer were analyzed, it was established that the absolute difference in temperatures of an isolated pipeline section and an unpainted section are 5-10 °C. The studies have also shown that when a 250×6 pipeline is coated with a 1 mm thick heat-insulating paint, it will save 126.1 m3 of natural gas per 1 running meter per year. In monetary terms it will be approximately 610 rubles or about $9 (for the first half of 2020). The payback period of this energy-saving measure should not exceed six months. Increasing the thickness of liquid heat insulation layer is not economically feasible. The equivalent fuel economy is approximately 65% when the heat-insulating paint is of 1 mm thickness, and it will increase by only 8% for a thickness of 1.5 mm.
- Open Access
- 21 April 2020
- Published by FSB Educational Establishment of Higher Education Daghestan State Technical University in Herald of Dagestan State Technical University. Technical Sciences
- Vol. 47 (1) , 147-155
FEATURES OF MOUNTED VENTILATED FACADE HEAT CONTROL SYSTEMS IN CONSTRUCTION PROJECTS
Abstract. Aim.An integral part of an energy audit of buildings and structures consists in thermal imaging diagnostics. This permits an evaluation of the heat-shielding properties of the enclosing structures of buildings in order to control the functional and operational status of engineering systems, as well as to identify implicit (invisible) and explicit (visible) defects in them. The aim of the work is to analyse some features and results of thermal control of an opaque hinged ventilated facade system and translucent enclosing structures in the form of window systems of a capital construction project.Method.Thermal imaging was used as a control for resolving issues of energy and resource conservation. The special importance of thermal control of translucent facade systems and non-translucent hinged ventilated facades of capital construction projects having various functional and operational purposes is highlighted.Results.A detailed algorithm is presented for supporting a comprehensive diagnosis of the heat engineering state of building envelopes for various construction projects by analysing thermograms, using thermal monitoring methods, to take into consideration engineering systems, building materials and finished products, along with technologies of full-scale thermal imaging inspection of translucent building envelopes. The obtained thermograms are presented and analysed.Conclusion.Current problems in the fields of energy efficiency and energy saving in the construction and energy industries are considered in the light of the latest technological developments. The proposed graph-analytical algorithm supporting a diagnosis of the heat engineering state of building envelopes based on the analysis of thermograms is the most comprehensive among known analogues and prototypes
- 21 April 2020
- Published by FSB Educational Establishment of Higher Education Daghestan State Technical University in Herald of Dagestan State Technical University. Technical Sciences
- Vol. 47 (1) , 147-155
Open AccessFEATURES OF MOUNTED VENTILATED FACADE HEAT CONTROL SYSTEMS IN CONSTRUCTION PROJECTS
Abstract. Aim.An integral part of an energy audit of buildings and structures consists in thermal imaging diagnostics. This permits an evaluation of the heat-shielding properties of the enclosing structures of buildings in order to control the functional and operational status of engineering systems, as well as to identify implicit (invisible) and explicit (visible) defects in them. The aim of the work is to analyse some features and results of thermal control of an opaque hinged ventilated facade system and translucent enclosing structures in the form of window systems of a capital construction project.Method.Thermal imaging was used as a control for resolving issues of energy and resource conservation. The special importance of thermal control of translucent facade systems and non-translucent hinged ventilated facades of capital construction projects having various functional and operational purposes is highlighted.Results.A detailed algorithm is presented for supporting a comprehensive diagnosis of the heat engineering state of building envelopes for various construction projects by analysing thermograms, using thermal monitoring methods, to take into consideration engineering systems, building materials and finished products, along with technologies of full-scale thermal imaging inspection of translucent building envelopes. The obtained thermograms are presented and analysed.Conclusion.Current problems in the fields of energy efficiency and energy saving in the construction and energy industries are considered in the light of the latest technological developments. The proposed graph-analytical algorithm supporting a diagnosis of the heat engineering state of building envelopes based on the analysis of thermograms is the most comprehensive among known analogues and prototypes
- Open Access
- 20 August 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 193, 03006
Modeling of greenhouse radiant heating
Commercially available greenhouses are commonly used for provision of year-round growing of agricultural crops at protected ground. In order to provide favorable conditions for plants growth these agricultural constructions should be equipped by artificial heating systems in cold sea-sons. This work presents an overview of basic traditional and alternative heating systems which find their applications in agriculture. Advantages of application of roof radiant heating with infrared radiation sources for green-houses are discussed. It was discovered that now there is no appropriate mathematical model of greenhouse radiant heating, which takes into account both heat and mass exchange processes. Here we propose a mathematical model of radiant heating, which includes equation system of both heat and mass exchange processes for greenhouse, its enclosure and soil. The numer-ical calculations were performed for commercially available greenhouse “Farmer 7.5”. We investigated the impact of external air temperature and heat exchange rate on the following greenhouse radiant heating characteris-tics: internal air temperature, heating system thermal power and water dis-charge for soil watering.
- 20 August 2018
- Published by EDP Sciences in MATEC Web of Conferences
- Vol. 193, 03006
Open AccessModeling of greenhouse radiant heating
Commercially available greenhouses are commonly used for provision of year-round growing of agricultural crops at protected ground. In order to provide favorable conditions for plants growth these agricultural constructions should be equipped by artificial heating systems in cold sea-sons. This work presents an overview of basic traditional and alternative heating systems which find their applications in agriculture. Advantages of application of roof radiant heating with infrared radiation sources for green-houses are discussed. It was discovered that now there is no appropriate mathematical model of greenhouse radiant heating, which takes into account both heat and mass exchange processes. Here we propose a mathematical model of radiant heating, which includes equation system of both heat and mass exchange processes for greenhouse, its enclosure and soil. The numer-ical calculations were performed for commercially available greenhouse “Farmer 7.5”. We investigated the impact of external air temperature and heat exchange rate on the following greenhouse radiant heating characteris-tics: internal air temperature, heating system thermal power and water dis-charge for soil watering.