Srinivasa Rao Gampa
Srinivasa Rao Gampa has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Debapriya Das
Department of Electrical Engineering, Indian Institute of Technology Kharagpur
6 shared publications- Preetham Goli
Division of Energy, Matter and Systems, University of Missouri-Kansas City, Kansas City, MO 64110, USA
6 shared publications D. Das
Electrical Engineering, I.I.T Kharagpur, Kharagpur, India
5 shared publications- Debapriya Das
Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
5 shared publications - Kiran Jasthi
Department of Electrical & Electronics Engineering, VNR Vignana Jyothi Institute of Engineering and Technology, Hyderabad 500090, Telangana, India
5 shared publications - Amarendra Alluri
Department of Electrical & Electronics Engineering, Seshadri Rao Gudlavalleru Engineering College, Gudlavalleru, Gudiwada 521356, Andhra Pradesh, India
4 shared publications
Latest Publications
- Open Access
- 26 September 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (19) , 9855
Optimum Design of Daily Load Profile of Distribution Systems Under Demand Response Conditions Using Fuzzy Multi-Objective Approach Based on Artificial Rabbits Optimization Technique
Demand response strategies are widely used by utilities to encourage customers to shift their loads from peak to off-peak periods, thereby offering lower electricity prices. This research proposes a fuzzy multi-objective artificial rabbits optimization (ARO) technique to design the optimal daily load profile of a distribution system under demand response. The daily load profile is partitioned into three zones comprising the left valley, peak period, and right valley. Two load-shifting factors governing the redistribution of peak-period demand between the two valley regions are optimized, ensuring that neither valley load factor exceeds the resulting post-shift peak load factor, while simultaneously accounting for cost-reduction and voltage-performance objectives. Optimally sized distributed generators (DGs) are allocated when demand response alone cannot restore voltage compliance. Simulation results presented for the 69-bus and 123-bus systems demonstrate that shifting load only to the left valley yields a 5.57% energy charge reduction and shifting the load only to the right valley results in a 2.43% reduction. The fuzzy multi-objective solution attains a 4.00% reduction while satisfying the loss and voltage objectives. The minimum voltage of the 69-bus system is restored to 0.95 p.u. with DG, while the 123-bus system complies without DG, and both show reduced daily real power losses. By mitigating peak demand, reducing real power losses, and integrating optimally sized DGs, the proposed method decreases the amount of energy that must be generated and delivered to satisfy the same load demand. In addition, it can defer network reinforcement requirements, thereby enhancing the economic and environmental sustainability of the distribution system.
- 26 September 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (19) , 9855
Open AccessOptimum Design of Daily Load Profile of Distribution Systems Under Demand Response Conditions Using Fuzzy Multi-Objective Approach Based on Artificial Rabbits Optimization Technique
Demand response strategies are widely used by utilities to encourage customers to shift their loads from peak to off-peak periods, thereby offering lower electricity prices. This research proposes a fuzzy multi-objective artificial rabbits optimization (ARO) technique to design the optimal daily load profile of a distribution system under demand response. The daily load profile is partitioned into three zones comprising the left valley, peak period, and right valley. Two load-shifting factors governing the redistribution of peak-period demand between the two valley regions are optimized, ensuring that neither valley load factor exceeds the resulting post-shift peak load factor, while simultaneously accounting for cost-reduction and voltage-performance objectives. Optimally sized distributed generators (DGs) are allocated when demand response alone cannot restore voltage compliance. Simulation results presented for the 69-bus and 123-bus systems demonstrate that shifting load only to the left valley yields a 5.57% energy charge reduction and shifting the load only to the right valley results in a 2.43% reduction. The fuzzy multi-objective solution attains a 4.00% reduction while satisfying the loss and voltage objectives. The minimum voltage of the 69-bus system is restored to 0.95 p.u. with DG, while the 123-bus system complies without DG, and both show reduced daily real power losses. By mitigating peak demand, reducing real power losses, and integrating optimally sized DGs, the proposed method decreases the amount of energy that must be generated and delivered to satisfy the same load demand. In addition, it can defer network reinforcement requirements, thereby enhancing the economic and environmental sustainability of the distribution system.
- Open Access
- 3 November 2025
- Published by MDPI AG in Inventions
- Vol. 10 (6) , 99
The Application of an Optimised Proportional–Integral–Derivative–Acceleration Controller to an Islanded Microgrid Scenario with Multiple Non-Conventional Power Resources
Presently, numerous non-conventional power resources have been applied in power system networks. However, these resources are very effective in islanded microgrid (IMG) scenarios for addressing numerous operational challenges. Additionally, it is observed that the power output of most of these resources is environment-dependent and intermittent in nature. This intermittency causes a power imbalance between the overall generated power and the load demand, which results in an undesired frequency oscillation. In order to address this unwanted frequency fluctuation, this research work proposes power–frequency synchronisation considering an islanded microgrid scenario under numerous non-conventional power resources. The major contribution of this work includes implementing a suitable and optimised control scheme that effectively controls diverse power system disturbances and various uncertainties. A Fick’s law optimisation-based proportional–integral–derivative–acceleration controller (PIDA) is implemented under this proposed power scenario. Additionally, an extensive performance assessment is conducted considering different simulation test cases in order to verify the performance of the proposed control topology. Further, the effectiveness of the suggested power network is tested on a 33-bus radial distribution network. Finally, simulation results are shown to show the effectiveness of the proposed control scheme for the efficient operation of the microgrid in achieving the desired performance under the diverse operating conditions.
- 3 November 2025
- Published by MDPI AG in Inventions
- Vol. 10 (6) , 99
Open AccessThe Application of an Optimised Proportional–Integral–Derivative–Acceleration Controller to an Islanded Microgrid Scenario with Multiple Non-Conventional Power Resources
Presently, numerous non-conventional power resources have been applied in power system networks. However, these resources are very effective in islanded microgrid (IMG) scenarios for addressing numerous operational challenges. Additionally, it is observed that the power output of most of these resources is environment-dependent and intermittent in nature. This intermittency causes a power imbalance between the overall generated power and the load demand, which results in an undesired frequency oscillation. In order to address this unwanted frequency fluctuation, this research work proposes power–frequency synchronisation considering an islanded microgrid scenario under numerous non-conventional power resources. The major contribution of this work includes implementing a suitable and optimised control scheme that effectively controls diverse power system disturbances and various uncertainties. A Fick’s law optimisation-based proportional–integral–derivative–acceleration controller (PIDA) is implemented under this proposed power scenario. Additionally, an extensive performance assessment is conducted considering different simulation test cases in order to verify the performance of the proposed control topology. Further, the effectiveness of the suggested power network is tested on a 33-bus radial distribution network. Finally, simulation results are shown to show the effectiveness of the proposed control scheme for the efficient operation of the microgrid in achieving the desired performance under the diverse operating conditions.
- Open Access
- 30 August 2025
- Published by MDPI AG in Inventions
- Vol. 10 (5) , 79
Optimum Sizing of Solar Photovoltaic Panels at Optimum Tilt and Azimuth Angles Using Grey Wolf Optimization Algorithm for Distribution Systems
This paper presents a novel methodology for the optimal sizing of solar photovoltaic (PV) systems in distribution networks by determining the monthly optimum tilt and azimuth angles to maximize solar energy capture. Using one year of solar irradiation data, the Grey Wolf Optimizer (GWO) is employed to optimize the tilt and azimuth angles with the objective of maximizing monthly solar insolation. Unlike existing approaches that assume fixed azimuth angles, the proposed method calculates both tilt and azimuth angles for each month, allowing for a more precise alignment with solar trajectories. The optimized orientation parameters are subsequently utilized to determine the optimal number and placement of PV panels, as well as the optimal location and sizing of shunt capacitor (SC) banks, for the IEEE 69-bus distribution system. This optimization is performed under peak load conditions using the GWO, with the objectives of minimizing active power losses, enhancing voltage profile stability, and maximizing PV system penetration. The long-term impact of this approach is assessed through a 20-year energy and economic savings analysis, demonstrating substantial improvements in energy efficiency and cost-effectiveness.
- 30 August 2025
- Published by MDPI AG in Inventions
- Vol. 10 (5) , 79
Open AccessOptimum Sizing of Solar Photovoltaic Panels at Optimum Tilt and Azimuth Angles Using Grey Wolf Optimization Algorithm for Distribution Systems
This paper presents a novel methodology for the optimal sizing of solar photovoltaic (PV) systems in distribution networks by determining the monthly optimum tilt and azimuth angles to maximize solar energy capture. Using one year of solar irradiation data, the Grey Wolf Optimizer (GWO) is employed to optimize the tilt and azimuth angles with the objective of maximizing monthly solar insolation. Unlike existing approaches that assume fixed azimuth angles, the proposed method calculates both tilt and azimuth angles for each month, allowing for a more precise alignment with solar trajectories. The optimized orientation parameters are subsequently utilized to determine the optimal number and placement of PV panels, as well as the optimal location and sizing of shunt capacitor (SC) banks, for the IEEE 69-bus distribution system. This optimization is performed under peak load conditions using the GWO, with the objectives of minimizing active power losses, enhancing voltage profile stability, and maximizing PV system penetration. The long-term impact of this approach is assessed through a 20-year energy and economic savings analysis, demonstrating substantial improvements in energy efficiency and cost-effectiveness.
- Open Access
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 44196-44213
Adaptive Frequency Control to Overcome Packet Dropouts and Uncertainties in Hybrid Power Systems
The increasing integration of renewable energy into hybrid power systems (HPS) introduces significant uncertainties, posing challenges to frequency control. Additionally, packet dropouts in measurement and control signals further complicate frequency regulation under these uncertain conditions. Existing frequency regulation techniques often neglect real-world data on load and source uncertainties, packet dropouts in measurement data, and lack comprehensive control. This paper presents a novel adaptive control architecture designed to maintain network frequency stability in the presence of packet dropouts and system uncertainties. The proposed methodology consists of offline uncertainty characterization and online adaptive control. A deep learning model predicts load uncertainties, while supervised machine learning models characterize renewable fluctuations, informing model-based control. Data-driven predictive control (DDPC) strategy has been implemented to compensate for packet dropouts. The DDPC features a triggering mechanism that activates adaptive control, combining uncertainty prediction with auxiliary control for dynamic frequency regulation. The proposed approach is validated through time-domain simulations on an isolated HPS with integrated renewable and distributed energy resources (DERs). Despite significant uncertainties and packet dropouts, the DDPC framework successfully limits frequency deviations to within 100 mHz. Furthermore, hardware-in-the-loop (HIL) simulations confirm the practical feasibility and robustness of the methodology. Integrating offline uncertainty characterization with online adaptive control offers an effective solution for robust frequency control in renewable integrated HPS.
- 10 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 44196-44213
Open AccessAdaptive Frequency Control to Overcome Packet Dropouts and Uncertainties in Hybrid Power Systems
The increasing integration of renewable energy into hybrid power systems (HPS) introduces significant uncertainties, posing challenges to frequency control. Additionally, packet dropouts in measurement and control signals further complicate frequency regulation under these uncertain conditions. Existing frequency regulation techniques often neglect real-world data on load and source uncertainties, packet dropouts in measurement data, and lack comprehensive control. This paper presents a novel adaptive control architecture designed to maintain network frequency stability in the presence of packet dropouts and system uncertainties. The proposed methodology consists of offline uncertainty characterization and online adaptive control. A deep learning model predicts load uncertainties, while supervised machine learning models characterize renewable fluctuations, informing model-based control. Data-driven predictive control (DDPC) strategy has been implemented to compensate for packet dropouts. The DDPC features a triggering mechanism that activates adaptive control, combining uncertainty prediction with auxiliary control for dynamic frequency regulation. The proposed approach is validated through time-domain simulations on an isolated HPS with integrated renewable and distributed energy resources (DERs). Despite significant uncertainties and packet dropouts, the DDPC framework successfully limits frequency deviations to within 100 mHz. Furthermore, hardware-in-the-loop (HIL) simulations confirm the practical feasibility and robustness of the methodology. Integrating offline uncertainty characterization with online adaptive control offers an effective solution for robust frequency control in renewable integrated HPS.
- Open Access
- 12 November 2024
- Published by MDPI AG in Inventions
- Vol. 9 (6) , 114
Multi-Objective Optimization Algorithm Based Bidirectional Long Short Term Memory Network Model for Optimum Sizing of Distributed Generators and Shunt Capacitors for Distribution Systems
In this paper, a multi-objective grey wolf optimization (GWO) algorithm based Bidirectional Long Short Term Memory (BiLSTM) network machine learning (ML) model is proposed for finding the optimum sizing of distributed generators (DGs) and shunt capacitors (SHCs) to enhance the performance of distribution systems at any desired load factor. The stochastic traits of evolutionary computing methods necessitate running the algorithm repeatedly to confirm the global optimum. In order to save utility engineers time and effort, this study introduces a BiLSTM network-based machine learning model to directly estimate the optimal values of DGs and SHCs, rather than relying on load flow estimates. At first, a multi-objective grey wolf optimizer determines the most suitable locations and capacities of DGs and SHCs at the unity load factor and the same locations are used to obtain optimum sizing of DGs and SHCs at other load factors also. The base case data sets consisting of substation apparent power, real power load, reactive power load, real power loss, reactive power loss and minimum node voltage at various load factors in per unit values are taken as input training data for the machine learning model. The optimal sizes of the DGs and SHCs for the corresponding load factors obtained using GWO algorithm are taken as target data sets in per unit values for the machine learning model. An adaptive moment estimation (adam) optimization approach is employed to train the BiLSTM ML model for identifying the ideal values of distributed generations and shunt capacitors at different load factors. The efficacy of the proposed ML-based sizing algorithm is demonstrated via simulation studies.
- 12 November 2024
- Published by MDPI AG in Inventions
- Vol. 9 (6) , 114
Open AccessMulti-Objective Optimization Algorithm Based Bidirectional Long Short Term Memory Network Model for Optimum Sizing of Distributed Generators and Shunt Capacitors for Distribution Systems
In this paper, a multi-objective grey wolf optimization (GWO) algorithm based Bidirectional Long Short Term Memory (BiLSTM) network machine learning (ML) model is proposed for finding the optimum sizing of distributed generators (DGs) and shunt capacitors (SHCs) to enhance the performance of distribution systems at any desired load factor. The stochastic traits of evolutionary computing methods necessitate running the algorithm repeatedly to confirm the global optimum. In order to save utility engineers time and effort, this study introduces a BiLSTM network-based machine learning model to directly estimate the optimal values of DGs and SHCs, rather than relying on load flow estimates. At first, a multi-objective grey wolf optimizer determines the most suitable locations and capacities of DGs and SHCs at the unity load factor and the same locations are used to obtain optimum sizing of DGs and SHCs at other load factors also. The base case data sets consisting of substation apparent power, real power load, reactive power load, real power loss, reactive power loss and minimum node voltage at various load factors in per unit values are taken as input training data for the machine learning model. The optimal sizes of the DGs and SHCs for the corresponding load factors obtained using GWO algorithm are taken as target data sets in per unit values for the machine learning model. An adaptive moment estimation (adam) optimization approach is employed to train the BiLSTM ML model for identifying the ideal values of distributed generations and shunt capacitors at different load factors. The efficacy of the proposed ML-based sizing algorithm is demonstrated via simulation studies.
- Open Access
- 25 May 2023
- Published by Springer Nature in Journal of Electrical Systems and Information Technology
- Vol. 10 (1) , 1-15
Fault classification of three phase induction motors using Bi-LSTM networks
The induction motors are back bone of the modern industry and play very important role in manufacturing and transportation sectors. The induction motor faults are mainly classified into internal faults such as inter turn short circuits , broken rotors and external faults such as over load, over voltage faults and asymmetry in supply voltage. The identification of type of fault is very important for safe operation and for preventing risk of machine failures. In this work, a Bidirectional Long Short Term memory networks (Bi-LSTM)-based machine learning methodology is proposed for classification of external faults of Induction Motors. The line voltages of the three phases and the three line currents are considered as the inputs to the Bi-LSTM network for identifying types of fault. Line voltage and line current data sets are considered for six different types of fault conditions. The six different conditions of the three phase induction motor are normal output (NO), overload (OL), over voltage (OV), under voltage (UV), Voltage unbalance (VUB) and single phasing (SP). The BI-LSTM network is trained using Adam optimization algorithm. The classification results are obtained with Bi-LSTM network are compared with LSTM networks to show the advantage of the proposed approach.
- 25 May 2023
- Published by Springer Nature in Journal of Electrical Systems and Information Technology
- Vol. 10 (1) , 1-15
Open AccessFault classification of three phase induction motors using Bi-LSTM networks
The induction motors are back bone of the modern industry and play very important role in manufacturing and transportation sectors. The induction motor faults are mainly classified into internal faults such as inter turn short circuits , broken rotors and external faults such as over load, over voltage faults and asymmetry in supply voltage. The identification of type of fault is very important for safe operation and for preventing risk of machine failures. In this work, a Bidirectional Long Short Term memory networks (Bi-LSTM)-based machine learning methodology is proposed for classification of external faults of Induction Motors. The line voltages of the three phases and the three line currents are considered as the inputs to the Bi-LSTM network for identifying types of fault. Line voltage and line current data sets are considered for six different types of fault conditions. The six different conditions of the three phase induction motor are normal output (NO), overload (OL), over voltage (OV), under voltage (UV), Voltage unbalance (VUB) and single phasing (SP). The BI-LSTM network is trained using Adam optimization algorithm. The classification results are obtained with Bi-LSTM network are compared with LSTM networks to show the advantage of the proposed approach.
- Open Access
- 25 May 2023
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 14 (6) , 137
Direct Torque Control of an Induction Motor Using Fractional-Order Sliding Mode Control Technique for Quick Response and Reduced Torque Ripple
The performance of electric drive propulsion systems is often degraded by the high torque and flux ripples of an electric drive. Traditional control methods, such as proportional plus integral (PI) controllers and classical sliding mode controllers (SMCs), have shown good response and reduced torque ripple, but even lower ripple content at low voltage levels is required for its effective use in electric vehicle (EV) applications. In this paper, a new direct torque control (DTC) technique with space vector pulse width modulation (SVPWM) using fractional-order sliding mode control (FOSMC) for a two-level inverter (2LI) at constant switching frequency is proposed. The effectiveness of this proposed controller is compared with a conventional proportional-integral controller and a conventional sliding mode controller (SMC). Simulink models are developed using MATLAB version R2018a to analyze the robustness of the proposed control strategy. Simulation results demonstrate the advantage of the proposed controller in reducing the torque ripples at steady state with less settling time during sudden load change conditions. The proposed control technique also demonstrates better utilization of the stator flux through flux trajectory waveforms.
- 25 May 2023
- Published by MDPI AG in World Electric Vehicle Journal
- Vol. 14 (6) , 137
Open AccessDirect Torque Control of an Induction Motor Using Fractional-Order Sliding Mode Control Technique for Quick Response and Reduced Torque Ripple
The performance of electric drive propulsion systems is often degraded by the high torque and flux ripples of an electric drive. Traditional control methods, such as proportional plus integral (PI) controllers and classical sliding mode controllers (SMCs), have shown good response and reduced torque ripple, but even lower ripple content at low voltage levels is required for its effective use in electric vehicle (EV) applications. In this paper, a new direct torque control (DTC) technique with space vector pulse width modulation (SVPWM) using fractional-order sliding mode control (FOSMC) for a two-level inverter (2LI) at constant switching frequency is proposed. The effectiveness of this proposed controller is compared with a conventional proportional-integral controller and a conventional sliding mode controller (SMC). Simulink models are developed using MATLAB version R2018a to analyze the robustness of the proposed control strategy. Simulation results demonstrate the advantage of the proposed controller in reducing the torque ripples at steady state with less settling time during sudden load change conditions. The proposed control technique also demonstrates better utilization of the stator flux through flux trajectory waveforms.
- Open Access
- 14 December 2022
- Published by Springer Nature in Journal of Electrical Systems and Information Technology
- Vol. 9 (1) , 1-18
Pareto optimality based PID controller design for vehicle active suspension system using grasshopper optimization algorithm
In this paper, a Pareto multiobjective and grasshopper optimization algorithm (GOA) based optimum proportional–integral–derivative (P–I–D) controller design is proposed for improving the vehicle active suspension system dynamics under road disturbance conditions. The Pareto objectives considered are minimization of sprung mass suspension deflection, tyre deflection, sprung mass acceleration minimization and eigenvalue-based objective function. State space model for quarter vehicle active suspension system with P–I–D controller is developed for analyzing the stability and dynamic performance of the system. The sinusoidal-based bump road disturbances are used for testing the robustness of the proposed control technique. Simulation results have been presented to show the advantage of the proposed Pareto multiobjective and GOA-based P–I–D controller over the weighted multiobjective and genetic algorithm-based P–I–D controller in terms of stability and dynamics of the active suspension system.
- 14 December 2022
- Published by Springer Nature in Journal of Electrical Systems and Information Technology
- Vol. 9 (1) , 1-18
Open AccessPareto optimality based PID controller design for vehicle active suspension system using grasshopper optimization algorithm
In this paper, a Pareto multiobjective and grasshopper optimization algorithm (GOA) based optimum proportional–integral–derivative (P–I–D) controller design is proposed for improving the vehicle active suspension system dynamics under road disturbance conditions. The Pareto objectives considered are minimization of sprung mass suspension deflection, tyre deflection, sprung mass acceleration minimization and eigenvalue-based objective function. State space model for quarter vehicle active suspension system with P–I–D controller is developed for analyzing the stability and dynamic performance of the system. The sinusoidal-based bump road disturbances are used for testing the robustness of the proposed control technique. Simulation results have been presented to show the advantage of the proposed Pareto multiobjective and GOA-based P–I–D controller over the weighted multiobjective and genetic algorithm-based P–I–D controller in terms of stability and dynamics of the active suspension system.
- Open Access
- 16 February 2022
- Published by MDPI AG in Smart Cities
- Vol. 5 (1) , 177-205
Electric Vehicle Charging Load Allocation at Residential Locations Utilizing the Energy Savings Gained by Optimal Network Reconductoring
In this study, a two-stage methodology based on the energy savings gained by optimal network reconductoring was developed for the sizing and allocation of electric vehicle (EV) charging load at the residential locations in urban distribution systems. During the first stage, the Flower Pollination Algorithm (FPA) was applied to minimize the annual energy losses of the radial distribution system through optimum network reconductoring. A multi-objective function was formulated to minimize investment, peak loss, and annual energy loss costs at different load factors. The results obtained with the flower pollination algorithm were compared with the particle swarm optimization algorithm. In the second stage, a simple heuristic procedure was developed for the sizing and allocation of EV charging load at every node of the distribution system utilizing part of the annual energy savings obtained by optimal network reconductoring. The number of electric cars, electric bikes, and electric scooters that can be charged at every node was computed while maintaining the voltage and branch current constraints. The simulation results were demonstrated on 123 bus and 51 bus radial distribution networks to validate the effectiveness of the proposed methodology.
- 16 February 2022
- Published by MDPI AG in Smart Cities
- Vol. 5 (1) , 177-205
Open AccessElectric Vehicle Charging Load Allocation at Residential Locations Utilizing the Energy Savings Gained by Optimal Network Reconductoring
In this study, a two-stage methodology based on the energy savings gained by optimal network reconductoring was developed for the sizing and allocation of electric vehicle (EV) charging load at the residential locations in urban distribution systems. During the first stage, the Flower Pollination Algorithm (FPA) was applied to minimize the annual energy losses of the radial distribution system through optimum network reconductoring. A multi-objective function was formulated to minimize investment, peak loss, and annual energy loss costs at different load factors. The results obtained with the flower pollination algorithm were compared with the particle swarm optimization algorithm. In the second stage, a simple heuristic procedure was developed for the sizing and allocation of EV charging load at every node of the distribution system utilizing part of the annual energy savings obtained by optimal network reconductoring. The number of electric cars, electric bikes, and electric scooters that can be charged at every node was computed while maintaining the voltage and branch current constraints. The simulation results were demonstrated on 123 bus and 51 bus radial distribution networks to validate the effectiveness of the proposed methodology.