Amarendra Alluri
Amarendra Alluri has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Debapriya Das
Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302, West Bengal, India
4 shared publications - Srinivasa Rao Gampa
Department of Electrical and Electronics Engineering, Gudlavalleru Engineering College, Andhra Pradesh, India
4 shared publications - Balaji Gutta
Department of Electrical & Electronics Engineering, Seshadri Rao Gudlavalleru Engineering College, Gudlavalleru, Gudiwada 521356, Andhra Pradesh, India
3 shared publications - Kiran Jasthi
Department of Electrical & Electronics Engineering, VNR Vignana Jyothi Institute of Engineering and Technology, Hyderabad 500090, Telangana, India
3 shared publications - Mahesh Babu Basam
Department of Electrical & Electronics Engineering, Seshadri Rao Gudlavalleru Engineering College, Gudlavalleru, Gudiwada 521356, Andhra Pradesh, India
3 shared publications - Preetham Goli
Division of Energy, Matter and Systems, University of Missouri-Kansas City, Kansas City, MO 64110, USA
2 shared publications
Latest Publications
- Open Access
- 26 September 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (19) , 9855
Optimum Design of Daily Load Profile of Distribution Systems Under Demand Response Conditions Using Fuzzy Multi-Objective Approach Based on Artificial Rabbits Optimization Technique
Demand response strategies are widely used by utilities to encourage customers to shift their loads from peak to off-peak periods, thereby offering lower electricity prices. This research proposes a fuzzy multi-objective artificial rabbits optimization (ARO) technique to design the optimal daily load profile of a distribution system under demand response. The daily load profile is partitioned into three zones comprising the left valley, peak period, and right valley. Two load-shifting factors governing the redistribution of peak-period demand between the two valley regions are optimized, ensuring that neither valley load factor exceeds the resulting post-shift peak load factor, while simultaneously accounting for cost-reduction and voltage-performance objectives. Optimally sized distributed generators (DGs) are allocated when demand response alone cannot restore voltage compliance. Simulation results presented for the 69-bus and 123-bus systems demonstrate that shifting load only to the left valley yields a 5.57% energy charge reduction and shifting the load only to the right valley results in a 2.43% reduction. The fuzzy multi-objective solution attains a 4.00% reduction while satisfying the loss and voltage objectives. The minimum voltage of the 69-bus system is restored to 0.95 p.u. with DG, while the 123-bus system complies without DG, and both show reduced daily real power losses. By mitigating peak demand, reducing real power losses, and integrating optimally sized DGs, the proposed method decreases the amount of energy that must be generated and delivered to satisfy the same load demand. In addition, it can defer network reinforcement requirements, thereby enhancing the economic and environmental sustainability of the distribution system.
- 26 September 2026
- Published by MDPI AG in Sustainability
- Vol. 18 (19) , 9855
Open AccessOptimum Design of Daily Load Profile of Distribution Systems Under Demand Response Conditions Using Fuzzy Multi-Objective Approach Based on Artificial Rabbits Optimization Technique
Demand response strategies are widely used by utilities to encourage customers to shift their loads from peak to off-peak periods, thereby offering lower electricity prices. This research proposes a fuzzy multi-objective artificial rabbits optimization (ARO) technique to design the optimal daily load profile of a distribution system under demand response. The daily load profile is partitioned into three zones comprising the left valley, peak period, and right valley. Two load-shifting factors governing the redistribution of peak-period demand between the two valley regions are optimized, ensuring that neither valley load factor exceeds the resulting post-shift peak load factor, while simultaneously accounting for cost-reduction and voltage-performance objectives. Optimally sized distributed generators (DGs) are allocated when demand response alone cannot restore voltage compliance. Simulation results presented for the 69-bus and 123-bus systems demonstrate that shifting load only to the left valley yields a 5.57% energy charge reduction and shifting the load only to the right valley results in a 2.43% reduction. The fuzzy multi-objective solution attains a 4.00% reduction while satisfying the loss and voltage objectives. The minimum voltage of the 69-bus system is restored to 0.95 p.u. with DG, while the 123-bus system complies without DG, and both show reduced daily real power losses. By mitigating peak demand, reducing real power losses, and integrating optimally sized DGs, the proposed method decreases the amount of energy that must be generated and delivered to satisfy the same load demand. In addition, it can defer network reinforcement requirements, thereby enhancing the economic and environmental sustainability of the distribution system.
- Open Access
- 3 November 2025
- Published by MDPI AG in Inventions
- Vol. 10 (6) , 99
The Application of an Optimised Proportional–Integral–Derivative–Acceleration Controller to an Islanded Microgrid Scenario with Multiple Non-Conventional Power Resources
Presently, numerous non-conventional power resources have been applied in power system networks. However, these resources are very effective in islanded microgrid (IMG) scenarios for addressing numerous operational challenges. Additionally, it is observed that the power output of most of these resources is environment-dependent and intermittent in nature. This intermittency causes a power imbalance between the overall generated power and the load demand, which results in an undesired frequency oscillation. In order to address this unwanted frequency fluctuation, this research work proposes power–frequency synchronisation considering an islanded microgrid scenario under numerous non-conventional power resources. The major contribution of this work includes implementing a suitable and optimised control scheme that effectively controls diverse power system disturbances and various uncertainties. A Fick’s law optimisation-based proportional–integral–derivative–acceleration controller (PIDA) is implemented under this proposed power scenario. Additionally, an extensive performance assessment is conducted considering different simulation test cases in order to verify the performance of the proposed control topology. Further, the effectiveness of the suggested power network is tested on a 33-bus radial distribution network. Finally, simulation results are shown to show the effectiveness of the proposed control scheme for the efficient operation of the microgrid in achieving the desired performance under the diverse operating conditions.
- 3 November 2025
- Published by MDPI AG in Inventions
- Vol. 10 (6) , 99
Open AccessThe Application of an Optimised Proportional–Integral–Derivative–Acceleration Controller to an Islanded Microgrid Scenario with Multiple Non-Conventional Power Resources
Presently, numerous non-conventional power resources have been applied in power system networks. However, these resources are very effective in islanded microgrid (IMG) scenarios for addressing numerous operational challenges. Additionally, it is observed that the power output of most of these resources is environment-dependent and intermittent in nature. This intermittency causes a power imbalance between the overall generated power and the load demand, which results in an undesired frequency oscillation. In order to address this unwanted frequency fluctuation, this research work proposes power–frequency synchronisation considering an islanded microgrid scenario under numerous non-conventional power resources. The major contribution of this work includes implementing a suitable and optimised control scheme that effectively controls diverse power system disturbances and various uncertainties. A Fick’s law optimisation-based proportional–integral–derivative–acceleration controller (PIDA) is implemented under this proposed power scenario. Additionally, an extensive performance assessment is conducted considering different simulation test cases in order to verify the performance of the proposed control topology. Further, the effectiveness of the suggested power network is tested on a 33-bus radial distribution network. Finally, simulation results are shown to show the effectiveness of the proposed control scheme for the efficient operation of the microgrid in achieving the desired performance under the diverse operating conditions.
- Open Access
- 30 August 2025
- Published by MDPI AG in Inventions
- Vol. 10 (5) , 79
Optimum Sizing of Solar Photovoltaic Panels at Optimum Tilt and Azimuth Angles Using Grey Wolf Optimization Algorithm for Distribution Systems
This paper presents a novel methodology for the optimal sizing of solar photovoltaic (PV) systems in distribution networks by determining the monthly optimum tilt and azimuth angles to maximize solar energy capture. Using one year of solar irradiation data, the Grey Wolf Optimizer (GWO) is employed to optimize the tilt and azimuth angles with the objective of maximizing monthly solar insolation. Unlike existing approaches that assume fixed azimuth angles, the proposed method calculates both tilt and azimuth angles for each month, allowing for a more precise alignment with solar trajectories. The optimized orientation parameters are subsequently utilized to determine the optimal number and placement of PV panels, as well as the optimal location and sizing of shunt capacitor (SC) banks, for the IEEE 69-bus distribution system. This optimization is performed under peak load conditions using the GWO, with the objectives of minimizing active power losses, enhancing voltage profile stability, and maximizing PV system penetration. The long-term impact of this approach is assessed through a 20-year energy and economic savings analysis, demonstrating substantial improvements in energy efficiency and cost-effectiveness.
- 30 August 2025
- Published by MDPI AG in Inventions
- Vol. 10 (5) , 79
Open AccessOptimum Sizing of Solar Photovoltaic Panels at Optimum Tilt and Azimuth Angles Using Grey Wolf Optimization Algorithm for Distribution Systems
This paper presents a novel methodology for the optimal sizing of solar photovoltaic (PV) systems in distribution networks by determining the monthly optimum tilt and azimuth angles to maximize solar energy capture. Using one year of solar irradiation data, the Grey Wolf Optimizer (GWO) is employed to optimize the tilt and azimuth angles with the objective of maximizing monthly solar insolation. Unlike existing approaches that assume fixed azimuth angles, the proposed method calculates both tilt and azimuth angles for each month, allowing for a more precise alignment with solar trajectories. The optimized orientation parameters are subsequently utilized to determine the optimal number and placement of PV panels, as well as the optimal location and sizing of shunt capacitor (SC) banks, for the IEEE 69-bus distribution system. This optimization is performed under peak load conditions using the GWO, with the objectives of minimizing active power losses, enhancing voltage profile stability, and maximizing PV system penetration. The long-term impact of this approach is assessed through a 20-year energy and economic savings analysis, demonstrating substantial improvements in energy efficiency and cost-effectiveness.
- Open Access
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (4) , 2128-2137
Modelling of Harris Hawks optimization with deep learning-assisted microgrid energy management approach
Microgrid (MG) is a potential decentralized energy distribution and generation technology that is resilient, reliable, and efficient. This small-scale power system is reliable and resilient since it connects to the grid or runs independently. Renewable energy is difficult to integrate into MG due to variable load and unreliable electricity. MG operation relies on an energy management system (EMS) to balance electricity demand and supply, reduce operational costs, and maximize renewable energy use. Intelligent control systems, optimization methods, and machine learning algorithms were used for MG EMS. The Harris Hawks optimization with deep learning-assisted microgrid energy management (HHODL-MGEM) technique is developed in this work. HHODL-MGEM comprises two main stages. In the first step, the HHODL-MGEM approach uses the Harris Hawks optimization or HHO algorithm to meet load power demands at a low cost while maintaining DC bus voltage and protecting the battery from overcharging and depletion. In the second step, long short-term memory (LSTM) networks can predict power costs. The HHODL-MGEM approach is evaluated using multiple methods. The experimental results showed that HHODL-MGEM outperforms other methods.
- 1 December 2024
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 15 (4) , 2128-2137
Open AccessModelling of Harris Hawks optimization with deep learning-assisted microgrid energy management approach
Microgrid (MG) is a potential decentralized energy distribution and generation technology that is resilient, reliable, and efficient. This small-scale power system is reliable and resilient since it connects to the grid or runs independently. Renewable energy is difficult to integrate into MG due to variable load and unreliable electricity. MG operation relies on an energy management system (EMS) to balance electricity demand and supply, reduce operational costs, and maximize renewable energy use. Intelligent control systems, optimization methods, and machine learning algorithms were used for MG EMS. The Harris Hawks optimization with deep learning-assisted microgrid energy management (HHODL-MGEM) technique is developed in this work. HHODL-MGEM comprises two main stages. In the first step, the HHODL-MGEM approach uses the Harris Hawks optimization or HHO algorithm to meet load power demands at a low cost while maintaining DC bus voltage and protecting the battery from overcharging and depletion. In the second step, long short-term memory (LSTM) networks can predict power costs. The HHODL-MGEM approach is evaluated using multiple methods. The experimental results showed that HHODL-MGEM outperforms other methods.
- Open Access
- 12 November 2024
- Published by MDPI AG in Inventions
- Vol. 9 (6) , 114
Multi-Objective Optimization Algorithm Based Bidirectional Long Short Term Memory Network Model for Optimum Sizing of Distributed Generators and Shunt Capacitors for Distribution Systems
In this paper, a multi-objective grey wolf optimization (GWO) algorithm based Bidirectional Long Short Term Memory (BiLSTM) network machine learning (ML) model is proposed for finding the optimum sizing of distributed generators (DGs) and shunt capacitors (SHCs) to enhance the performance of distribution systems at any desired load factor. The stochastic traits of evolutionary computing methods necessitate running the algorithm repeatedly to confirm the global optimum. In order to save utility engineers time and effort, this study introduces a BiLSTM network-based machine learning model to directly estimate the optimal values of DGs and SHCs, rather than relying on load flow estimates. At first, a multi-objective grey wolf optimizer determines the most suitable locations and capacities of DGs and SHCs at the unity load factor and the same locations are used to obtain optimum sizing of DGs and SHCs at other load factors also. The base case data sets consisting of substation apparent power, real power load, reactive power load, real power loss, reactive power loss and minimum node voltage at various load factors in per unit values are taken as input training data for the machine learning model. The optimal sizes of the DGs and SHCs for the corresponding load factors obtained using GWO algorithm are taken as target data sets in per unit values for the machine learning model. An adaptive moment estimation (adam) optimization approach is employed to train the BiLSTM ML model for identifying the ideal values of distributed generations and shunt capacitors at different load factors. The efficacy of the proposed ML-based sizing algorithm is demonstrated via simulation studies.
- 12 November 2024
- Published by MDPI AG in Inventions
- Vol. 9 (6) , 114
Open AccessMulti-Objective Optimization Algorithm Based Bidirectional Long Short Term Memory Network Model for Optimum Sizing of Distributed Generators and Shunt Capacitors for Distribution Systems
In this paper, a multi-objective grey wolf optimization (GWO) algorithm based Bidirectional Long Short Term Memory (BiLSTM) network machine learning (ML) model is proposed for finding the optimum sizing of distributed generators (DGs) and shunt capacitors (SHCs) to enhance the performance of distribution systems at any desired load factor. The stochastic traits of evolutionary computing methods necessitate running the algorithm repeatedly to confirm the global optimum. In order to save utility engineers time and effort, this study introduces a BiLSTM network-based machine learning model to directly estimate the optimal values of DGs and SHCs, rather than relying on load flow estimates. At first, a multi-objective grey wolf optimizer determines the most suitable locations and capacities of DGs and SHCs at the unity load factor and the same locations are used to obtain optimum sizing of DGs and SHCs at other load factors also. The base case data sets consisting of substation apparent power, real power load, reactive power load, real power loss, reactive power loss and minimum node voltage at various load factors in per unit values are taken as input training data for the machine learning model. The optimal sizes of the DGs and SHCs for the corresponding load factors obtained using GWO algorithm are taken as target data sets in per unit values for the machine learning model. An adaptive moment estimation (adam) optimization approach is employed to train the BiLSTM ML model for identifying the ideal values of distributed generations and shunt capacitors at different load factors. The efficacy of the proposed ML-based sizing algorithm is demonstrated via simulation studies.
- Open Access
- 20 March 2024
- Published by FOREX Publication in International Journal of Electrical and Electronics Research
- Vol. 12 (1) , 219-227
Improving Intrusion Detection using Satin Bowerbird Optimization with Deep Learning Model for IIoT Environment
Intrusion Detection in the Industrial Internet of Things (IIoT) concentrations on the security and safety of critical structures and industrial developments. IIoT extends IoT principles to industrial environments, but linked sensors and devices can be deployed for monitoring, automation, and control of manufacturing, energy, and other critical systems. Intrusion detection systems (IDS) in IoT drive to monitor network traffic, device behavior, and system anomalies for detecting and responding to security breaches. These IDS solutions exploit a range of systems comprising signature-based detection, anomaly detection, machine learning (ML), and behavioral analysis, for identifying suspicious actions like device tampering, unauthorized access, data exfiltration, and denial-of-service (DoS) attacks. This study presents an Improving Intrusion Detection using Satin Bowerbird Optimization with Deep Learning (IID-SBODL) model for IIoT Environment. The IID-SBODL technique initially preprocesses the input data for compatibility. Next, the IID-SBODL technique applies Echo State Network (ESN) model for effectual recognition and classification of the intrusions. Finally, the SBO algorithm optimizes the configuration of the ESN, boosting its capability for precise identification of anomalies and significant security breaches within IIoT networks. By widespread simulation evaluation, the experimental results pointed out that the IID-SBODL technique reaches maximum detection rate and improves the security of the IIoT environment. Through comprehensive experimentation on both UNSW-NB15 and UCI SECOM datasets, the model exhibited exceptional performance, achieving an average accuracy of 99.55% and 98.87%, precision of 98.90% and 98.93%, recall of 98.87% and 98.80%, and F-score of 98.88% and 98.87% for the respective datasets. The IID-SBODL model contributes to the development of robust intrusion detection mechanisms for safeguarding critical industrial processes in the era of interconnected and smart IIoT environments.
- 20 March 2024
- Published by FOREX Publication in International Journal of Electrical and Electronics Research
- Vol. 12 (1) , 219-227
Open AccessImproving Intrusion Detection using Satin Bowerbird Optimization with Deep Learning Model for IIoT Environment
Intrusion Detection in the Industrial Internet of Things (IIoT) concentrations on the security and safety of critical structures and industrial developments. IIoT extends IoT principles to industrial environments, but linked sensors and devices can be deployed for monitoring, automation, and control of manufacturing, energy, and other critical systems. Intrusion detection systems (IDS) in IoT drive to monitor network traffic, device behavior, and system anomalies for detecting and responding to security breaches. These IDS solutions exploit a range of systems comprising signature-based detection, anomaly detection, machine learning (ML), and behavioral analysis, for identifying suspicious actions like device tampering, unauthorized access, data exfiltration, and denial-of-service (DoS) attacks. This study presents an Improving Intrusion Detection using Satin Bowerbird Optimization with Deep Learning (IID-SBODL) model for IIoT Environment. The IID-SBODL technique initially preprocesses the input data for compatibility. Next, the IID-SBODL technique applies Echo State Network (ESN) model for effectual recognition and classification of the intrusions. Finally, the SBO algorithm optimizes the configuration of the ESN, boosting its capability for precise identification of anomalies and significant security breaches within IIoT networks. By widespread simulation evaluation, the experimental results pointed out that the IID-SBODL technique reaches maximum detection rate and improves the security of the IIoT environment. Through comprehensive experimentation on both UNSW-NB15 and UCI SECOM datasets, the model exhibited exceptional performance, achieving an average accuracy of 99.55% and 98.87%, precision of 98.90% and 98.93%, recall of 98.87% and 98.80%, and F-score of 98.88% and 98.87% for the respective datasets. The IID-SBODL model contributes to the development of robust intrusion detection mechanisms for safeguarding critical industrial processes in the era of interconnected and smart IIoT environments.
- 12 April 2022
- Published by Springer Nature in Soft Computing
- Vol. 26 (13) , 6265-6291
Power system security enhancement in FACTS devices based on Yin–Yang pair optimization algorithm
- 12 April 2022
- Published by Springer Nature in Soft Computing
- Vol. 26 (13) , 6265-6291
Power system security enhancement in FACTS devices based on Yin–Yang pair optimization algorithm
- Open Access
- 16 April 2021
- Published by European Alliance for Innovation n.o. in EAI Endorsed Transactions on Energy Web
- Vol. 8 (36) , e9
Security Enhancement in Power System Using FACTS Devices and Atom Search Optimization Algorithm
In power systems, control, system operations are an important and difficult task by enhancing the power systems' security. An enhancement of the security system is done by the optimal location selection of the Flexible Alternating Current Transmission System (FACTS) devices, for instance, Unified Power Flow Controller (UPFC), Thyristor-Controlled Series Capacitor (TCSC), Interlink Power Flow Controller (IPFC), and Static VAR Compensator (SVC). Therefore, the Atom Search Algorithm (ASO) is utilized to compute the precise optimal placement of the FACTS device. FACTS devices must be in the correct location on the power system to improve system safety. The performances are evaluated by severity index, Line Overload Sensitivity Index (LOSI), voltage, voltage deviation ̧, power loss, fitness function, and the fuel cost with the IEEE 30, IEEE 118, and IEEE 300 bus system. To validate the proposed methodology, it is contrasted with the conventional techniques like Dragonfly Algorithm (DA), Whale Optimization Algorithm (WOA), Jaya, Flower Pollination Algorithm (FPA), Grey Wolf Algorithm (GWA), and the Jaya Flower Pollination (JA-FPA) systems.
- 16 April 2021
- Published by European Alliance for Innovation n.o. in EAI Endorsed Transactions on Energy Web
- Vol. 8 (36) , e9
Open AccessSecurity Enhancement in Power System Using FACTS Devices and Atom Search Optimization Algorithm
In power systems, control, system operations are an important and difficult task by enhancing the power systems' security. An enhancement of the security system is done by the optimal location selection of the Flexible Alternating Current Transmission System (FACTS) devices, for instance, Unified Power Flow Controller (UPFC), Thyristor-Controlled Series Capacitor (TCSC), Interlink Power Flow Controller (IPFC), and Static VAR Compensator (SVC). Therefore, the Atom Search Algorithm (ASO) is utilized to compute the precise optimal placement of the FACTS device. FACTS devices must be in the correct location on the power system to improve system safety. The performances are evaluated by severity index, Line Overload Sensitivity Index (LOSI), voltage, voltage deviation ̧, power loss, fitness function, and the fuel cost with the IEEE 30, IEEE 118, and IEEE 300 bus system. To validate the proposed methodology, it is contrasted with the conventional techniques like Dragonfly Algorithm (DA), Whale Optimization Algorithm (WOA), Jaya, Flower Pollination Algorithm (FPA), Grey Wolf Algorithm (GWA), and the Jaya Flower Pollination (JA-FPA) systems.