Yusuke Aoyama
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yusuke Aoyama has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Yutaka Tabe
Hokkaido University
7 shared publications - Kengo Suzuki
University of Tsukuba
4 shared publications Takemi Chikahisa
Division of Energy and Environmental Systems, Graduate School of Engineering, Hokkaido University, Sapporo, Hokkaido 060-8628, Japan
4 shared publications- Suguru Uemura
Department of Mechanical Engineering, Tokyo Institute of Technology, 2-12-1 Ookayama, Meguro-ku, Tokyo 152-8552, Japan
3 shared publications Toshihiro Tanuma
Asahi Glass Co., Ltd. Research Center, Yokohama, Kanagawa 221-8875, Japan
2 shared publicationsAkira Nagata
Energy & Functional Materials Research Lab, Sumitomo Chemical Co. Ltd, Ehime, Japan
1 shared publication
Latest Publications
- 27 December 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 100, 853-862
Electricity storage and hydrogen generation system using the electrochemical reaction of lithium and water
- 27 December 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 100, 853-862
Electricity storage and hydrogen generation system using the electrochemical reaction of lithium and water
- 2 June 2020
- Published by Taylor & Francis in Welding International
- Vol. 34 (4-6) , 125-137
Friction stir welding of ultra high-purity aluminium thin sheets never to lower high conductivity at ultra-low temperature
Ultrahigh-purity aluminium sheets with excellent electrical and thermal conductivity at ultra-low temperature have uses in heat dissipation components in, for example, superconducting equipment. Recently, here has been a requirement for the development of methods of welding these sheets without degrading their excellent conductivity. This study focused on friction stir welding (FSW), which was conducted for 99.999 wt.% (5 N) Al thin sheets with thickness of 0.8 mm. The FSW tool rotation speed was set to 3000 rpm, and both the welding speed and tool insertion depth were varied. Decreasing welding speed suppressed the occurrence of a kissing bond on an FSW back side and increased the area of the stir zone that had ultrafine grains, although residual strain in all the joints was greater than in tungsten inert gas (TIG)-welded joints which consisted of coarse grains similar to the base metal. Fracture occurred in the base metal in tensile tests of the FSW joints except for those made at the maximum welding speed, in contrast to rupture near the fusion line of the TIG-welded joint due to blowholes. On the other hand, the residual resistivity ratio (RRR) of FSW and TIG-welded joints decreased to almost half of that of the base metal. The heat treatment at 500°C for 3 h increased the RRR of the FSW joints to almost the same value as that of the base metal. This is attributed to a significant reduction of residual strain as well as grain coarsening. In TIG-welded joint, there is an evident decrease in the RRR associated with a decrease in purity. Therefore, FSW in conjunction with post-weld heat treatment would be a better choice to achieve high conductivity at ultra-low temperatures in 5 N-Al thin sheet joints, while maintaining a high joining strength.
- 2 June 2020
- Published by Taylor & Francis in Welding International
- Vol. 34 (4-6) , 125-137
Friction stir welding of ultra high-purity aluminium thin sheets never to lower high conductivity at ultra-low temperature
Ultrahigh-purity aluminium sheets with excellent electrical and thermal conductivity at ultra-low temperature have uses in heat dissipation components in, for example, superconducting equipment. Recently, here has been a requirement for the development of methods of welding these sheets without degrading their excellent conductivity. This study focused on friction stir welding (FSW), which was conducted for 99.999 wt.% (5 N) Al thin sheets with thickness of 0.8 mm. The FSW tool rotation speed was set to 3000 rpm, and both the welding speed and tool insertion depth were varied. Decreasing welding speed suppressed the occurrence of a kissing bond on an FSW back side and increased the area of the stir zone that had ultrafine grains, although residual strain in all the joints was greater than in tungsten inert gas (TIG)-welded joints which consisted of coarse grains similar to the base metal. Fracture occurred in the base metal in tensile tests of the FSW joints except for those made at the maximum welding speed, in contrast to rupture near the fusion line of the TIG-welded joint due to blowholes. On the other hand, the residual resistivity ratio (RRR) of FSW and TIG-welded joints decreased to almost half of that of the base metal. The heat treatment at 500°C for 3 h increased the RRR of the FSW joints to almost the same value as that of the base metal. This is attributed to a significant reduction of residual strain as well as grain coarsening. In TIG-welded joint, there is an evident decrease in the RRR associated with a decrease in purity. Therefore, FSW in conjunction with post-weld heat treatment would be a better choice to achieve high conductivity at ultra-low temperatures in 5 N-Al thin sheet joints, while maintaining a high joining strength.
- Open Access
- 10 May 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (7) , F484-F491
Analysis of Water Transport inside Hydrophilic Carbon Fiber Micro-Porous Layers with High-Performance Operation in PEFC
Polymer electrolyte membrane fuel cells using a hydrophilic micro-porous layer (MPL) consisting of carbon fiber (CF) and ionomer show better performance than those using conventional hydrophobic MPL with carbon black (CB) under a wide range of humidity conditions. This study investigates the effects of the wettability and structure of the MPL on cell performance and discusses the mechanism for improving cell performance by the hydrophilic CF-MPL at high humidity conditions. The water distribution inside the MPL is evaluated by a freezing method and cryo-SEM observations, and a comparison of the distribution and the cell performance of hydrophilic and hydrophobic MPL cells with various structures is made. The results show that the performance improvement is caused by preventing increases in concentration overvoltage at high current densities; where the fiber structure and thicker layers are important with hydrophilic MPL. In hydrophilic CF-MPL with better performance, liquid water accumulates in pores at the catalyst layer (CL) side, while there is no liquid water at the gas diffusion layer side. These results indicate that the hydrophilic CF-MPL enhances the liquid water transport from the CL due to the hydrophilic properties, and promotes water evaporation due to the large pores in the thick fiber structure.
- 10 May 2018
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 165 (7) , F484-F491
Open AccessAnalysis of Water Transport inside Hydrophilic Carbon Fiber Micro-Porous Layers with High-Performance Operation in PEFC
Polymer electrolyte membrane fuel cells using a hydrophilic micro-porous layer (MPL) consisting of carbon fiber (CF) and ionomer show better performance than those using conventional hydrophobic MPL with carbon black (CB) under a wide range of humidity conditions. This study investigates the effects of the wettability and structure of the MPL on cell performance and discusses the mechanism for improving cell performance by the hydrophilic CF-MPL at high humidity conditions. The water distribution inside the MPL is evaluated by a freezing method and cryo-SEM observations, and a comparison of the distribution and the cell performance of hydrophilic and hydrophobic MPL cells with various structures is made. The results show that the performance improvement is caused by preventing increases in concentration overvoltage at high current densities; where the fiber structure and thicker layers are important with hydrophilic MPL. In hydrophilic CF-MPL with better performance, liquid water accumulates in pores at the catalyst layer (CL) side, while there is no liquid water at the gas diffusion layer side. These results indicate that the hydrophilic CF-MPL enhances the liquid water transport from the CL due to the hydrophilic properties, and promotes water evaporation due to the large pores in the thick fiber structure.
- Open Access
- 2 August 2016
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 163 (10) , F1139-F1145
Ice Formation Processes in PEM Fuel Cell Catalyst Layers during Cold Startup Analyzed by Cryo-SEM
For further improvements in the startup ability below freezing and the durability of polymer electrolyte fuel cells, understanding the ice formation mechanism during cold startup is particularly significant. This study observes cross-sectional ice distributions in a catalyst layer (CL) during isothermal galvanostatic operation at −20°C using a cryo-scanning electron microscope. The effects of current density, cathode gas conditions, initial water content of the membrane, and cell temperature on the cold start characteristics and the ice formation process in the CL are evaluated. The observational results show that at higher current densities, the region with active ice formation moves from the membrane to the gas diffusion layer sides during the freezing period and vacant pores remain near the membrane even after cell shutdown, while the pores are completely filled with nearly-uniformly growing ice at lower current density operation. This is consistent with the experimental finding from the cold start characteristics that the estimated amount of ice accumulated in the cell until the shutdown decreases as the current density increases. Contrary to expectations, these changes are largely independent of cathode gas conditions, even with pure oxygen. Additional factors controlling the ice formation process are discussed based on the experimental results.
- 2 August 2016
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 163 (10) , F1139-F1145
Open AccessIce Formation Processes in PEM Fuel Cell Catalyst Layers during Cold Startup Analyzed by Cryo-SEM
For further improvements in the startup ability below freezing and the durability of polymer electrolyte fuel cells, understanding the ice formation mechanism during cold startup is particularly significant. This study observes cross-sectional ice distributions in a catalyst layer (CL) during isothermal galvanostatic operation at −20°C using a cryo-scanning electron microscope. The effects of current density, cathode gas conditions, initial water content of the membrane, and cell temperature on the cold start characteristics and the ice formation process in the CL are evaluated. The observational results show that at higher current densities, the region with active ice formation moves from the membrane to the gas diffusion layer sides during the freezing period and vacant pores remain near the membrane even after cell shutdown, while the pores are completely filled with nearly-uniformly growing ice at lower current density operation. This is consistent with the experimental finding from the cold start characteristics that the estimated amount of ice accumulated in the cell until the shutdown decreases as the current density increases. Contrary to expectations, these changes are largely independent of cathode gas conditions, even with pure oxygen. Additional factors controlling the ice formation process are discussed based on the experimental results.
- Open Access
- 27 January 2016
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 163 (5) , F359-F366
Water Transport and PEFC Performance with Different Interface Structure between Micro-Porous Layer and Catalyst Layer
For interfaces between micro-porous layers (MPL) and catalyst layers (CL) made by the gas diffusion electrode (GDE) method, a seamless interface without gaps, shows better performance than that of cells with an interface made by the decal transfer method. With the decal transfer method, the MPL is simply hot-pressed to the CL-membrane assembly. This study investigates the effect of interface structure on cell performance and water transport in the MPL. Water distribution in cross sections of multiple layers were observed by a freezing method, where the cell is cooled below freezing temperature in short time and the water was observed in ice form by Cryo-SEM. The results show that a membrane electrode assembly (MEA) using the GDE method improves cell performance at high current densities. Direct observations by the freezing method and cryo-SEM show that there is no water accumulation at the MPL/CL interface made by the GDE method, while water accumulates at the interface made by the decal method. Other observations show that the water amount inside the MPL increases similarly in the two types of MEA when lowering the temperature, and the difference between the two types of MEA was only the water amount in the interface.
- 27 January 2016
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 163 (5) , F359-F366
Open AccessWater Transport and PEFC Performance with Different Interface Structure between Micro-Porous Layer and Catalyst Layer
For interfaces between micro-porous layers (MPL) and catalyst layers (CL) made by the gas diffusion electrode (GDE) method, a seamless interface without gaps, shows better performance than that of cells with an interface made by the decal transfer method. With the decal transfer method, the MPL is simply hot-pressed to the CL-membrane assembly. This study investigates the effect of interface structure on cell performance and water transport in the MPL. Water distribution in cross sections of multiple layers were observed by a freezing method, where the cell is cooled below freezing temperature in short time and the water was observed in ice form by Cryo-SEM. The results show that a membrane electrode assembly (MEA) using the GDE method improves cell performance at high current densities. Direct observations by the freezing method and cryo-SEM show that there is no water accumulation at the MPL/CL interface made by the GDE method, while water accumulates at the interface made by the decal method. Other observations show that the water amount inside the MPL increases similarly in the two types of MEA when lowering the temperature, and the difference between the two types of MEA was only the water amount in the interface.