Yutaka Tabe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Yutaka Tabe has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
Takemi Chikahisa
Division of Mechanical and Aerospace Engineering, Graduate School of Engineering, Hokkaido University, Sapporo, Hokkaido 060-8628, Japan
90 shared publicationsKengo Suzuki
Graduate School of Engineering, Hokkaido University
12 shared publicationsSuguru Uemura
Hokkaido University
12 shared publicationsSatoshi Sakaida
Ibaraki University
9 shared publications- Kengo Suzuki
University of Tsukuba
7 shared publications - Yusuke Aoyama
Division of Energy and Environmental Systems, Graduate School of Engineering, Hokkaido University, Sapporo, Hokkaido 060-8628, Japan
7 shared publications
Latest Publications
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (6) , 921
Low-Dimensionalization Experiments on Porous Cathodes and Analysis of Oxygen Transport and Reaction Distributions Toward High-Power Lithium-Air Batteries
Lithium-air batteries (LABs), with their exceptionally high theoretical energy density, are considered promising candidates for next-generation energy storage[1]. However, LABs still have many challenges in terms of improving cycle characteristics and increasing power output. Currently, it is difficult to supply sufficient oxygen to the cathode reaction surface, preventing the realization of high-power output. In typical LAB designs employing porous cathodes, oxygen must diffuse through narrow, electrolyte-filled pores [2, 3]. Due to its low solubility and diffusivity in the electrolyte, oxygen transport is significantly limited. Oxygen transport phenomena within the pores are considered to affect the discharge characteristics of the cathode; however, the detailed mechanisms remain unclear. In this study, we investigated fundamental discharge characteristics of LABs by using a low-dimensionalized cathode that mimics the oxygen transport phenomena in a porous cathode. The approach was based on a combination of experimental discharge tests and analysis using a transmission line model. The distributions of oxygen concentration in the electrolyte of the low-dimensional cathode and current density distribution on the reaction surface were investigated. Figure 1 shows the concept of low-dimensionalization and the structure of the cell used in the experiments of this study. To isolate and study these phenomena, a custom experimental setup was fabricated using flat glassy carbon (GC) plates. By covering part of the GC plate with resin and alkaline-resistant tape the area available for oxygen dissolution into the electrolyte was restricted. This configuration enabled analysis to focus on the transport properties within the pores of the porous cathode. By varying the thickness and number of tape layers, the area available for oxygen dissolution was controlled. This configuration enabled the investigation of how the size of the oxygen supply area affects discharge performance. As a result of discharge tests, in cathodes without restriction of the oxygen dissolution area, the decrease in cathode potential was gradual even under high current conditions. It is due to the easy supply of oxygen from the atmosphere to the reaction surface. In contrast, when the oxygen dissolution area was restricted, the cathode potential dropped sharply with increasing current. This behavior is caused by a significant increase in concentration overpotential resulting from the limited oxygen supply, and similar behavior is expected to occur in porous cathodes with small pores. To analyze these experimental results, a transmission line model incorporating the Butler–Volmer equation and Fick's law was constructed. The model assumes a uniform potential distribution on the cathode reaction surface and calculates the local current density as a function of the overpotential and oxygen concentration. This model also takes into account the rate of oxygen dissolution at the electrolyte interface. By fitting the main parameters, the simulation results showed good agreement with the experimental data, as illustrated in the Figure 2 particularly in the high-current region where the cathode potential drops sharply. Using this model, the reaction distribution and oxygen concentration distribution were calculated. As shown in Figure 3, when the current is low (2 mA), oxygen is transported to a depth of approximately 2 mm into the cathode, and the reaction distribution remains relatively uniform. In contrast, when the current is increased to 5 mA, oxygen is transported only to a depth of around 0.4 mm, and the oxygen concentration near the interface falls below the saturation concentration. These results suggest that the rate of oxygen dissolution becomes the limiting factor for discharge performance under higher current conditions. References [1] Girishkumar, G., McCloskey, B., Luntz, A. C., Swanson, S., Wilcke, W., “Lithium−air battery: promise and challenges,” J. Phys. Chem. Lett., 1(14), pp 2193–2203, (2010). [2] Shibata, K., Uemura, S., Tsushima, S., Hirai, S., “Reaction and mass transport simulations by LBM in electrolyte of aqueous lithium-air battery,” ECS Trans. , 64(19), pp 39-46, (2015). [3] Fujimoto, S., Uemura, S., Imanihsi, N., Hirai, S., “Oxygen concentration measurement in the porous cathode of a lithium-air battery using a fine optical fiber sensor,” Mechanical Engineering Letters , 5, pp 19-00095, (2019). Figure 1
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (6) , 921
Low-Dimensionalization Experiments on Porous Cathodes and Analysis of Oxygen Transport and Reaction Distributions Toward High-Power Lithium-Air Batteries
Lithium-air batteries (LABs), with their exceptionally high theoretical energy density, are considered promising candidates for next-generation energy storage[1]. However, LABs still have many challenges in terms of improving cycle characteristics and increasing power output. Currently, it is difficult to supply sufficient oxygen to the cathode reaction surface, preventing the realization of high-power output. In typical LAB designs employing porous cathodes, oxygen must diffuse through narrow, electrolyte-filled pores [2, 3]. Due to its low solubility and diffusivity in the electrolyte, oxygen transport is significantly limited. Oxygen transport phenomena within the pores are considered to affect the discharge characteristics of the cathode; however, the detailed mechanisms remain unclear. In this study, we investigated fundamental discharge characteristics of LABs by using a low-dimensionalized cathode that mimics the oxygen transport phenomena in a porous cathode. The approach was based on a combination of experimental discharge tests and analysis using a transmission line model. The distributions of oxygen concentration in the electrolyte of the low-dimensional cathode and current density distribution on the reaction surface were investigated. Figure 1 shows the concept of low-dimensionalization and the structure of the cell used in the experiments of this study. To isolate and study these phenomena, a custom experimental setup was fabricated using flat glassy carbon (GC) plates. By covering part of the GC plate with resin and alkaline-resistant tape the area available for oxygen dissolution into the electrolyte was restricted. This configuration enabled analysis to focus on the transport properties within the pores of the porous cathode. By varying the thickness and number of tape layers, the area available for oxygen dissolution was controlled. This configuration enabled the investigation of how the size of the oxygen supply area affects discharge performance. As a result of discharge tests, in cathodes without restriction of the oxygen dissolution area, the decrease in cathode potential was gradual even under high current conditions. It is due to the easy supply of oxygen from the atmosphere to the reaction surface. In contrast, when the oxygen dissolution area was restricted, the cathode potential dropped sharply with increasing current. This behavior is caused by a significant increase in concentration overpotential resulting from the limited oxygen supply, and similar behavior is expected to occur in porous cathodes with small pores. To analyze these experimental results, a transmission line model incorporating the Butler–Volmer equation and Fick's law was constructed. The model assumes a uniform potential distribution on the cathode reaction surface and calculates the local current density as a function of the overpotential and oxygen concentration. This model also takes into account the rate of oxygen dissolution at the electrolyte interface. By fitting the main parameters, the simulation results showed good agreement with the experimental data, as illustrated in the Figure 2 particularly in the high-current region where the cathode potential drops sharply. Using this model, the reaction distribution and oxygen concentration distribution were calculated. As shown in Figure 3, when the current is low (2 mA), oxygen is transported to a depth of approximately 2 mm into the cathode, and the reaction distribution remains relatively uniform. In contrast, when the current is increased to 5 mA, oxygen is transported only to a depth of around 0.4 mm, and the oxygen concentration near the interface falls below the saturation concentration. These results suggest that the rate of oxygen dissolution becomes the limiting factor for discharge performance under higher current conditions. References [1] Girishkumar, G., McCloskey, B., Luntz, A. C., Swanson, S., Wilcke, W., “Lithium−air battery: promise and challenges,” J. Phys. Chem. Lett., 1(14), pp 2193–2203, (2010). [2] Shibata, K., Uemura, S., Tsushima, S., Hirai, S., “Reaction and mass transport simulations by LBM in electrolyte of aqueous lithium-air battery,” ECS Trans. , 64(19), pp 39-46, (2015). [3] Fujimoto, S., Uemura, S., Imanihsi, N., Hirai, S., “Oxygen concentration measurement in the porous cathode of a lithium-air battery using a fine optical fiber sensor,” Mechanical Engineering Letters , 5, pp 19-00095, (2019). Figure 1
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (43) , 2180
Flow Field Structure for Improving Start-up Performance and Power Output in Non-Humidified High-Temperature PEFC
Polymer electrolyte fuel cells (PEFCs) are used for automobiles and other applications due to their excellent start-up ability and high energy efficiency, etc. Although the PEFCs are expected to be widely applied to commercial applications in the near future, low cooling capacity is one of the issues. Non-humidified high-temperature PEFCs (HT-PEFCs) can operate at high temperatures above 100°C by doping the polymer electrolyte membrane with acid and are effective in improving the cooling capacity with the larger temperature difference. However, HT-PEFCs have problems such as low oxygen concentration at high temperatures and condensation of water generated during start-up below 100°C. Low oxygen concentration increases the concentration overpotential. Condensed water leaches acids contained in the membrane electrode assembly (MEA), causing degradation. In this study, we focused on the flow field structure for a non-humidified HT-PEFC, and aimed to improve the generated water discharge during start-up and the power output above 100°C. Figure 1 shows the structure and picture of HT-PEFC single cell used in this study. Polybenzimidazole (PBI) based MEA APM STD25 (reaction area: 5 x 5 cm 2 ) manufactured by Advent Technologies was used. In the experiments to investigate the start-up performance, a single cell with a similar structure and PRIMEA (Gore) were used to avoid degradation due to condensed water. Figure 2 shows the structure of four types of flow fields: (a) 1.0 mm straight, (b) 0.5 mm straight, (c) interdigitated, and (d) porous (porosity: 91 %) flow fields. All experiments are conducted with non-humidified air for the cathode and hydrogen for the anode. Figure 3 compares the I-V characteristics of the cells with various flow fields at (a) 120°C and (b) 140°C with back pressure of 120 kPa and 200 kPa. The results show that higher pressure increases the current densities. The high pressure increases the volume molar concentration of oxygen, resulting in a decrease in the concentration overpotential. The activation overpotential also decreases under high temperature and high-pressure conditions (1) . Comparing the effects of flow field structures, the interdigitated flow field can operate up to the highest current densities. This suggests that air flow in the gas diffusion layer (GDL) with the interdigitated flow field (Fig. 2 (c)) can enhance the oxygen supply to the catalyst layer (CL) and decrease the concentration overpotential. Figure 4 shows the experimental results of steady state operation, (a) the cell voltage and (b) the cell resistance, at low temperatures below 100°C. The cell voltage of the 1.0 mm straight flow field increases as the cell temperature increase between 40 and 52°C, followed by a decrease in the voltage at the high temperatures. The decrease in cell voltage is accompanied by an increase in the cell resistance, and this is estimated due to drying of the MEA, suggesting that the cell with the 1.0 mm straight flow field can suppress condensation of generated water above 52°C. In the interdigitated flow field, the cell voltage starts to decrease at 48°C, and the cell resistance starts to increase at 44°C. The operation above 52°C was not possible. This indicates that the interdigitated flow field may prevent generated water from condensing from lower temperatures than the 1.0 mm straight flow field. However, the cell voltage of the interdigitated flow field is the lowest at around 40°C, and this may be because the produced water accumulates in the inlet channels, making it difficult to supply oxygen under the plugging region. In the 0.5 mm straight and the porous flow fields, the cell voltages start to decrease from even lower temperatures. This may be due to the narrower rib width of the 0.5 mm straight flow field and the ribless structure of the porous flow field promote the discharge of generated water from the CL. Additionally, our previous study reported that the temperature of MEA in the porous flow field tends to easily increase (2) due to low thermal conductivity of the porous material. These results indicate that the 0.5 mm straight and the porous flow fields are effective in enhancing water removal from the MEA and improving start-up performance. Acknowledgement We would like to thank the Suzuki Foundation in Japan for supporting this study. References (1) A. R. Korsgaad, et al., Journal of Power Sources , 162 (2006). (2) Y. Tabe, et al., Journal of Power Sources , 238, (2013). Figure 1
- 24 November 2025
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2025-02 (43) , 2180
Flow Field Structure for Improving Start-up Performance and Power Output in Non-Humidified High-Temperature PEFC
Polymer electrolyte fuel cells (PEFCs) are used for automobiles and other applications due to their excellent start-up ability and high energy efficiency, etc. Although the PEFCs are expected to be widely applied to commercial applications in the near future, low cooling capacity is one of the issues. Non-humidified high-temperature PEFCs (HT-PEFCs) can operate at high temperatures above 100°C by doping the polymer electrolyte membrane with acid and are effective in improving the cooling capacity with the larger temperature difference. However, HT-PEFCs have problems such as low oxygen concentration at high temperatures and condensation of water generated during start-up below 100°C. Low oxygen concentration increases the concentration overpotential. Condensed water leaches acids contained in the membrane electrode assembly (MEA), causing degradation. In this study, we focused on the flow field structure for a non-humidified HT-PEFC, and aimed to improve the generated water discharge during start-up and the power output above 100°C. Figure 1 shows the structure and picture of HT-PEFC single cell used in this study. Polybenzimidazole (PBI) based MEA APM STD25 (reaction area: 5 x 5 cm 2 ) manufactured by Advent Technologies was used. In the experiments to investigate the start-up performance, a single cell with a similar structure and PRIMEA (Gore) were used to avoid degradation due to condensed water. Figure 2 shows the structure of four types of flow fields: (a) 1.0 mm straight, (b) 0.5 mm straight, (c) interdigitated, and (d) porous (porosity: 91 %) flow fields. All experiments are conducted with non-humidified air for the cathode and hydrogen for the anode. Figure 3 compares the I-V characteristics of the cells with various flow fields at (a) 120°C and (b) 140°C with back pressure of 120 kPa and 200 kPa. The results show that higher pressure increases the current densities. The high pressure increases the volume molar concentration of oxygen, resulting in a decrease in the concentration overpotential. The activation overpotential also decreases under high temperature and high-pressure conditions (1) . Comparing the effects of flow field structures, the interdigitated flow field can operate up to the highest current densities. This suggests that air flow in the gas diffusion layer (GDL) with the interdigitated flow field (Fig. 2 (c)) can enhance the oxygen supply to the catalyst layer (CL) and decrease the concentration overpotential. Figure 4 shows the experimental results of steady state operation, (a) the cell voltage and (b) the cell resistance, at low temperatures below 100°C. The cell voltage of the 1.0 mm straight flow field increases as the cell temperature increase between 40 and 52°C, followed by a decrease in the voltage at the high temperatures. The decrease in cell voltage is accompanied by an increase in the cell resistance, and this is estimated due to drying of the MEA, suggesting that the cell with the 1.0 mm straight flow field can suppress condensation of generated water above 52°C. In the interdigitated flow field, the cell voltage starts to decrease at 48°C, and the cell resistance starts to increase at 44°C. The operation above 52°C was not possible. This indicates that the interdigitated flow field may prevent generated water from condensing from lower temperatures than the 1.0 mm straight flow field. However, the cell voltage of the interdigitated flow field is the lowest at around 40°C, and this may be because the produced water accumulates in the inlet channels, making it difficult to supply oxygen under the plugging region. In the 0.5 mm straight and the porous flow fields, the cell voltages start to decrease from even lower temperatures. This may be due to the narrower rib width of the 0.5 mm straight flow field and the ribless structure of the porous flow field promote the discharge of generated water from the CL. Additionally, our previous study reported that the temperature of MEA in the porous flow field tends to easily increase (2) due to low thermal conductivity of the porous material. These results indicate that the 0.5 mm straight and the porous flow fields are effective in enhancing water removal from the MEA and improving start-up performance. Acknowledgement We would like to thank the Suzuki Foundation in Japan for supporting this study. References (1) A. R. Korsgaad, et al., Journal of Power Sources , 162 (2006). (2) Y. Tabe, et al., Journal of Power Sources , 238, (2013). Figure 1
- 27 December 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 100, 853-862
Electricity storage and hydrogen generation system using the electrochemical reaction of lithium and water
- 27 December 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 100, 853-862
Electricity storage and hydrogen generation system using the electrochemical reaction of lithium and water
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (44) , 2988
Enhancement of Liquid Water and Oxygen Transport By Partially Hydrophilic Mpls in a PEFC
Management of produced water is extremely important to increase the output of PEFCs. Several methods have been investigated to improve the ability to manage liquid water transport by partially adding hydrophilicity to hydrophobic MPLs. In this study, we focused on MPLs coated with a hydrophilic layer(1). By separating the oxygen transport resistance inside and outside the catalyst layer (CL), we analyzed the effect of condensed water in the cell on the oxygen transport phenomenon, and aimed to provide guidelines for the production of MPLs for further power enhancement. A mixture of carbon black: Li-400 (made by DENKA CO.) and Nafion dispersion liquid in a solvent consisting of pure water and ethanol was coated on the MPL side of the gas diffusion layer: 28BC (made by SGL CO.) and allowed to dry to produce the hydrophilic layer. The ratio of carbon black and Nafion in the hydrophilic layer was 10 : 1, and the thickness was about 5 μm. In this study, active area of the cell was 1.8 cm2 (0.9 cm × 2.0 cm). The MPL on the anode side was 28BC and the cathode side was 28BC with a hydrophilic layer applied. The anode side was supplied with hydrogen, and the cathode side was supplied with a mixed gas of oxygen and nitrogen. The gas flow rates were 500 sccm for the anode and 4000 sccm for the cathode. Experiments were conducted at a cell temperature of 35°C with supplied gases of 81% RH. The catalyst coated membrane was produced by Japan Gore-Tex Inc. The oxygen transport resistances were measured by using the limiting current method(2). Inside the CL (pressure independence), it was assumed that the water production rate dominates the water accumulation, which is proportional to current densities. Outside the CL (pressure dependence), it was assumed that the product of total pressure and current density determined the component of oxygen transport resistance. Based on this assumption, the division of oxygen transport resistance was determined by a least square error calculation of actual total oxygen transport resistances and theoretical values(2). This experiment was conducted with different pressure (100 kPa, 140 kPa, 180 kPa), and different oxygen concentration (1%, 2%, 4%, 6%, 8%, 12%, 15%, 18%, 21%). Figure 1 shows the results of oxygen transport resistance in each inside and outside CL. Here, I Lim is limiting current density, and R P (Figure 1 (a)) and R NP (Figure 1 (b)) are pressure-dependent or independent oxygen transport resistances, respectively. These corresponds to the oxygen transport resistance outside and inside the CL. The MPL-1 is 28BC and the MPL-2 is 28BC with a hydrophilic layer applied. In Figure 1(a), the R P of MPL-2 is larger by the hydrophilic layer, and the tendency of change is similar: the R P increases from the low current density region. This shows that the effect of the hydrophilic layer on condensed water is negligible. In Figure 1(b), the R NP of MPL-2 is kept smaller in the low current density region, while it is slightly smaller than that of MPL-1 in the medium and high current density regions. This suggests that condensed water is efficiently sucked out of the CL in the low current density region, but the ability of water removal is insufficient in the medium and high current density regions. The condensed water may be retained in the hydrophilic layer due to its strong hydrophilicity. In this study, the oxygen transport resistance was separated based on the pressure dependence, allowing quantitative investigation of mass transport phenomena inside the cell. The analysis suggested the improvement of water removal ability from the CL by adding the hydrophilic layer to the MPL. We try to apply adding carbon nanotubes to the MPL for further improvement of the ability of water management. Reference (1) T. Kitahara, et al., Transactions of the JSME (B) (in Japanese), 78-794, 1849 (2012). (2) Y. Iizuka, et al, J. Electrochem. Soc., 169-12, 124510 (2022). Figure 1
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (44) , 2988
Enhancement of Liquid Water and Oxygen Transport By Partially Hydrophilic Mpls in a PEFC
Management of produced water is extremely important to increase the output of PEFCs. Several methods have been investigated to improve the ability to manage liquid water transport by partially adding hydrophilicity to hydrophobic MPLs. In this study, we focused on MPLs coated with a hydrophilic layer(1). By separating the oxygen transport resistance inside and outside the catalyst layer (CL), we analyzed the effect of condensed water in the cell on the oxygen transport phenomenon, and aimed to provide guidelines for the production of MPLs for further power enhancement. A mixture of carbon black: Li-400 (made by DENKA CO.) and Nafion dispersion liquid in a solvent consisting of pure water and ethanol was coated on the MPL side of the gas diffusion layer: 28BC (made by SGL CO.) and allowed to dry to produce the hydrophilic layer. The ratio of carbon black and Nafion in the hydrophilic layer was 10 : 1, and the thickness was about 5 μm. In this study, active area of the cell was 1.8 cm2 (0.9 cm × 2.0 cm). The MPL on the anode side was 28BC and the cathode side was 28BC with a hydrophilic layer applied. The anode side was supplied with hydrogen, and the cathode side was supplied with a mixed gas of oxygen and nitrogen. The gas flow rates were 500 sccm for the anode and 4000 sccm for the cathode. Experiments were conducted at a cell temperature of 35°C with supplied gases of 81% RH. The catalyst coated membrane was produced by Japan Gore-Tex Inc. The oxygen transport resistances were measured by using the limiting current method(2). Inside the CL (pressure independence), it was assumed that the water production rate dominates the water accumulation, which is proportional to current densities. Outside the CL (pressure dependence), it was assumed that the product of total pressure and current density determined the component of oxygen transport resistance. Based on this assumption, the division of oxygen transport resistance was determined by a least square error calculation of actual total oxygen transport resistances and theoretical values(2). This experiment was conducted with different pressure (100 kPa, 140 kPa, 180 kPa), and different oxygen concentration (1%, 2%, 4%, 6%, 8%, 12%, 15%, 18%, 21%). Figure 1 shows the results of oxygen transport resistance in each inside and outside CL. Here, I Lim is limiting current density, and R P (Figure 1 (a)) and R NP (Figure 1 (b)) are pressure-dependent or independent oxygen transport resistances, respectively. These corresponds to the oxygen transport resistance outside and inside the CL. The MPL-1 is 28BC and the MPL-2 is 28BC with a hydrophilic layer applied. In Figure 1(a), the R P of MPL-2 is larger by the hydrophilic layer, and the tendency of change is similar: the R P increases from the low current density region. This shows that the effect of the hydrophilic layer on condensed water is negligible. In Figure 1(b), the R NP of MPL-2 is kept smaller in the low current density region, while it is slightly smaller than that of MPL-1 in the medium and high current density regions. This suggests that condensed water is efficiently sucked out of the CL in the low current density region, but the ability of water removal is insufficient in the medium and high current density regions. The condensed water may be retained in the hydrophilic layer due to its strong hydrophilicity. In this study, the oxygen transport resistance was separated based on the pressure dependence, allowing quantitative investigation of mass transport phenomena inside the cell. The analysis suggested the improvement of water removal ability from the CL by adding the hydrophilic layer to the MPL. We try to apply adding carbon nanotubes to the MPL for further improvement of the ability of water management. Reference (1) T. Kitahara, et al., Transactions of the JSME (B) (in Japanese), 78-794, 1849 (2012). (2) Y. Iizuka, et al, J. Electrochem. Soc., 169-12, 124510 (2022). Figure 1
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (46) , 3245
Overpotential Characteristic and Flow Field Structure for High Power Output of HT-PEFC
Polymer electrolyte fuel cells (PEFCs) are used for automobiles and other applications due to their excellent startup ability and load followability. From now on, PEFCs are expected to be widely applied to commercial applications. However, when conventional PEFC needs high-load operation, insufficient cooling capacity becomes a major issue. This is due to the small temperature difference between the FC stack and the outside air. The conventional electrolyte membrane uses the water as a proton-conducting path, so PEFC’s operation temperature must be controlled below 100°C. Therefore, applying high-temperature PEFC (HT-PEFC) is effective to improve cooling capacity. HT-PEFC can operate at high-temperature (above 100°C) by doping the acid as a proton conducting path in the polymer electrolyte membrane. In this study, we evaluated the effects of the temperature, the gas pressure, and the gas flow field structure on the power output at high-temperature. Figure 1 shows the structure and picture of HT-PEFC single cell used in this study. Polybenzimidazole (PBI) -based MEA APM STD25 (reaction area: 5 x 5 cm2) manufactured by Advent Technologies was used. The performance was compared by using the straight flow channels (pitch: 2.0 mm, 1.0 mm) and the porous flow field (porosity: 91%) for the separator. All experiments are conducted with non-humidified air and hydrogen. Figure 2 shows the I-V characteristics at various cell temperature and gas pressure with the 2.0 mm pitch straight flow channel. As the cell temperature increases, the I-V characteristic improves, especially in the low-medium current density region. In addition, increasing the gas pressure improves the performance in the entire current density range. The overpotential was separated to discuss these results. The activation overpotential was calculated by Tafel equation, and the concentration overpotential was calculated by subtracting the activation overpotential and the resistance overpotential (= IR) from the total overpotential. Figure 3 shows the results of the activation overpotential and the concentration overpotential at the current density of 2.0 A/cm2. The activation overpotential is reduced at high-temperature and high-pressure. These trends agree with the previous studies. The exchange current density of PBI-MEA increases at high-temperature(1). The oxygen molar concentration become high and the exchange current density is increased at high-pressure(2). On the other hand, the concentration overpotential increases at high-temperature. This is because the air expands at high-temperature and the oxygen’s molar concentration decreases. Although this phenomenon is a major issue in HT-PEFC, the concentration overpotential can be reduced even at high-temperature by increasing the gas pressure. Figure 4 shows the results of I-V characteristics for the three gas flow fields. Here, IR corrected voltage is used to eliminate the influence of the contact resistance due to the flow field structure. Compared to the 2.0 mm pitch straight flow channel, the concentration overpotentials of the 1.0 mm pitch straight flow channel and the porous flow field are reduced. As shown in Figure 5, this is due to improving the oxygen supply under the flow channel ribs(3). Especially, this effect is significant at high-temperature where the oxygen molar concentration is lower. Additionally, in our previous study(4), when using the porous flow field in conventional PEFC (below 100°C), performance degradation due to dry-out was a major issue. However, the porous flow field is useful for HT-PEFC because the polymer electrolyte membrane has low durability against the liquid water and active drainage of generated water is required. Acknowledgement We would like to thank the Suzuki Foundation in Japan for supporting this study. References (1) A. R. Korsgaad, et al., Journal of Power Sources, 162 (2006). (2) Y. Tabe, et al., Journal of Electrochemical Society, 158 (2011). (3) Y. Iizuka, et al., Journal of Electrochemical Society, 169, (2022). (4) Y. Tabe, et al., Journal of Power Sources, 238, (2013). Figure 1
- 22 November 2024
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2024-02 (46) , 3245
Overpotential Characteristic and Flow Field Structure for High Power Output of HT-PEFC
Polymer electrolyte fuel cells (PEFCs) are used for automobiles and other applications due to their excellent startup ability and load followability. From now on, PEFCs are expected to be widely applied to commercial applications. However, when conventional PEFC needs high-load operation, insufficient cooling capacity becomes a major issue. This is due to the small temperature difference between the FC stack and the outside air. The conventional electrolyte membrane uses the water as a proton-conducting path, so PEFC’s operation temperature must be controlled below 100°C. Therefore, applying high-temperature PEFC (HT-PEFC) is effective to improve cooling capacity. HT-PEFC can operate at high-temperature (above 100°C) by doping the acid as a proton conducting path in the polymer electrolyte membrane. In this study, we evaluated the effects of the temperature, the gas pressure, and the gas flow field structure on the power output at high-temperature. Figure 1 shows the structure and picture of HT-PEFC single cell used in this study. Polybenzimidazole (PBI) -based MEA APM STD25 (reaction area: 5 x 5 cm2) manufactured by Advent Technologies was used. The performance was compared by using the straight flow channels (pitch: 2.0 mm, 1.0 mm) and the porous flow field (porosity: 91%) for the separator. All experiments are conducted with non-humidified air and hydrogen. Figure 2 shows the I-V characteristics at various cell temperature and gas pressure with the 2.0 mm pitch straight flow channel. As the cell temperature increases, the I-V characteristic improves, especially in the low-medium current density region. In addition, increasing the gas pressure improves the performance in the entire current density range. The overpotential was separated to discuss these results. The activation overpotential was calculated by Tafel equation, and the concentration overpotential was calculated by subtracting the activation overpotential and the resistance overpotential (= IR) from the total overpotential. Figure 3 shows the results of the activation overpotential and the concentration overpotential at the current density of 2.0 A/cm2. The activation overpotential is reduced at high-temperature and high-pressure. These trends agree with the previous studies. The exchange current density of PBI-MEA increases at high-temperature(1). The oxygen molar concentration become high and the exchange current density is increased at high-pressure(2). On the other hand, the concentration overpotential increases at high-temperature. This is because the air expands at high-temperature and the oxygen’s molar concentration decreases. Although this phenomenon is a major issue in HT-PEFC, the concentration overpotential can be reduced even at high-temperature by increasing the gas pressure. Figure 4 shows the results of I-V characteristics for the three gas flow fields. Here, IR corrected voltage is used to eliminate the influence of the contact resistance due to the flow field structure. Compared to the 2.0 mm pitch straight flow channel, the concentration overpotentials of the 1.0 mm pitch straight flow channel and the porous flow field are reduced. As shown in Figure 5, this is due to improving the oxygen supply under the flow channel ribs(3). Especially, this effect is significant at high-temperature where the oxygen molar concentration is lower. Additionally, in our previous study(4), when using the porous flow field in conventional PEFC (below 100°C), performance degradation due to dry-out was a major issue. However, the porous flow field is useful for HT-PEFC because the polymer electrolyte membrane has low durability against the liquid water and active drainage of generated water is required. Acknowledgement We would like to thank the Suzuki Foundation in Japan for supporting this study. References (1) A. R. Korsgaad, et al., Journal of Power Sources, 162 (2006). (2) Y. Tabe, et al., Journal of Electrochemical Society, 158 (2011). (3) Y. Iizuka, et al., Journal of Electrochemical Society, 169, (2022). (4) Y. Tabe, et al., Journal of Power Sources, 238, (2013). Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (37) , 1704
Performance Analysis of Non-Humidified High-Temperature PEFC by Fuel Cell System Simulator
Polymer electrolyte fuel cells (PEFCs) are widely used for automobiles and other applications due to their excellent start-ability and load followability. For further popularization in the future, it is expected to be applied to commercial vehicles such as large trucks and buses. However, insufficient cooling of the PEFC becomes a major issue, for example when heavy-duty vehicle needs to operate on uphill roads at high-loads and high- temperatures. This is because conventional electrolyte membranes use water as a proton-conducting carrier, so PEFC’s operation temperature must be controlled below 100°C. In this study, we focus on high-temperature PEFC (HT-PEFC), which is expected to improve cooling performance by high-temperature operation (over 100°C). HT-PEFC can operate under non-humidified high-temperature environment by doping phosphoric acid as a proton-conducting carrier in the electrolyte membrane. Then, we evaluate the usefulness of the HT-PEFC by performance analysis using a FC system simulator. We use FC-DynaMo(1),(2), which is researched and developed by NEDO's industry-academia-government collaboration project, as the FC system simulator. FC-DynaMo is based on the FC stack system of Toyota motor corporation's 2nd generation MIRAI. As shown in Figure 1, in addition to the FC stack, hydrogen system, air system, and cooling system are also modeled, making it possible to simulate unsteady operation. The target vehicle for the simulation is a heavy-duty truck (Class8), and the results of a survey conducted by Zhang et al.(3) on the various uses of in the United States were used as a reference. From the results including output power, vehicle speed, and road gradient, we extracted and used the driving data of long-haul with continuous uphill and downhill roads, which is considered to be the high-load and high-temperature operation. For the membrane electrode assembly (MEA) of HT-PEFC, we used APM STD (PBI-MEA) manufactured by Advent technologies, which uses a polybenzimidazole membrane. We give the characteristic that the exchange current density increases exponentially as the temperature rises, referring to the study of Korsgaard et al.(4). In addition, proton conductivity is given as 10S/m published by Advent technologies. Figure 2(a) shows the calculated IV characteristic of MIRAI-MEA. And Figure 2(b) shows the that of PBI-MEA. As the temperature rises, the effect of reducing the activation overpotential by increasing the exchange current density can be confirmed. These results are in good agreement with the study which investigated the operation characteristics of PBI-MEA by Chen et al.(5) and Waller et al.(6). However, compared to the IV characteristic of MIRAI-MEA shown in Figure 2(a), the overpotential is too large, the maximum output is less than half, and the heat generation is nearly double. This is because it is nearly twice as large as the MIRAI-MEA’s activation overpotential, which causes a decrease in output power and an increase in heat generation. With this current PBI-MEA performance, it is difficult to evaluate the system compared with MIRAI-MEA. Therefore, in this study, we hypothetically set up a high-temperature MEA assuming future development (Virtual HT-MEA). Virtual HT-MEA is given MIRAI-MEA’s low activation overpotential and the characteristics of PBI-MEA that don’t dry-out at high-temperature. Figure 2(c) shows the Virtual HT-MEA’s IV characteristics. Here, at high current density, the performance at 120°C and 180°C is lower than that at 70°C because the concentration overpotential increases due to the decrease in the oxygen molar concentration at high-temperature. Figure 3 shows the results of Class8 driving simulation with each MEA adapted to the FC stack. In the MIRAI-MEA shown in Figure 3(a), a combination of 4-FC stack systems and 5-cooling systems is optimal. With this combination, the FC cell temperature can be controlled below 95°C. Figure 3(b) shows the analysis results of the FC stack using PBI-MEA. As shown in Figure 2(b), the PBI-MEA has a large overpotential, so a combination of 10-FC stack systems and 5-cooling systems is required to meet the request power. The current PBI-MEA’s performance cannot show the merits of non-humidified high-temperature operation. Figure 3(c) shows the analysis results of the FC stack using the Virtual HT-MEA. Stable operation is possible with 4-FC stack systems and 2-cooling systems. This means that 3-cooling systems can be reduced compared to the MIRAI-MEA’s system. This is because the cooling performance is improved due to the larger temperature difference between the outside air and the FC stacks. Reference (1)S.Hasegawa, et al., ECS Transactions,104, (2021) (2)S.Hasegawa, et al., ECS Transactions,109, (2022) (3)C.Zhang, et al., Transportation Research,Part D95, (2021) (4)A.R.Korsgaad, et al., Journal of Power Sources,162, (2006) (5)C.-Y.Chen, et al., Journal of Power Sources,195, (2010) (6)M.G.Waller, et al., International Journal of Hydrogen Energy,41, (2016) Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (37) , 1704
Performance Analysis of Non-Humidified High-Temperature PEFC by Fuel Cell System Simulator
Polymer electrolyte fuel cells (PEFCs) are widely used for automobiles and other applications due to their excellent start-ability and load followability. For further popularization in the future, it is expected to be applied to commercial vehicles such as large trucks and buses. However, insufficient cooling of the PEFC becomes a major issue, for example when heavy-duty vehicle needs to operate on uphill roads at high-loads and high- temperatures. This is because conventional electrolyte membranes use water as a proton-conducting carrier, so PEFC’s operation temperature must be controlled below 100°C. In this study, we focus on high-temperature PEFC (HT-PEFC), which is expected to improve cooling performance by high-temperature operation (over 100°C). HT-PEFC can operate under non-humidified high-temperature environment by doping phosphoric acid as a proton-conducting carrier in the electrolyte membrane. Then, we evaluate the usefulness of the HT-PEFC by performance analysis using a FC system simulator. We use FC-DynaMo(1),(2), which is researched and developed by NEDO's industry-academia-government collaboration project, as the FC system simulator. FC-DynaMo is based on the FC stack system of Toyota motor corporation's 2nd generation MIRAI. As shown in Figure 1, in addition to the FC stack, hydrogen system, air system, and cooling system are also modeled, making it possible to simulate unsteady operation. The target vehicle for the simulation is a heavy-duty truck (Class8), and the results of a survey conducted by Zhang et al.(3) on the various uses of in the United States were used as a reference. From the results including output power, vehicle speed, and road gradient, we extracted and used the driving data of long-haul with continuous uphill and downhill roads, which is considered to be the high-load and high-temperature operation. For the membrane electrode assembly (MEA) of HT-PEFC, we used APM STD (PBI-MEA) manufactured by Advent technologies, which uses a polybenzimidazole membrane. We give the characteristic that the exchange current density increases exponentially as the temperature rises, referring to the study of Korsgaard et al.(4). In addition, proton conductivity is given as 10S/m published by Advent technologies. Figure 2(a) shows the calculated IV characteristic of MIRAI-MEA. And Figure 2(b) shows the that of PBI-MEA. As the temperature rises, the effect of reducing the activation overpotential by increasing the exchange current density can be confirmed. These results are in good agreement with the study which investigated the operation characteristics of PBI-MEA by Chen et al.(5) and Waller et al.(6). However, compared to the IV characteristic of MIRAI-MEA shown in Figure 2(a), the overpotential is too large, the maximum output is less than half, and the heat generation is nearly double. This is because it is nearly twice as large as the MIRAI-MEA’s activation overpotential, which causes a decrease in output power and an increase in heat generation. With this current PBI-MEA performance, it is difficult to evaluate the system compared with MIRAI-MEA. Therefore, in this study, we hypothetically set up a high-temperature MEA assuming future development (Virtual HT-MEA). Virtual HT-MEA is given MIRAI-MEA’s low activation overpotential and the characteristics of PBI-MEA that don’t dry-out at high-temperature. Figure 2(c) shows the Virtual HT-MEA’s IV characteristics. Here, at high current density, the performance at 120°C and 180°C is lower than that at 70°C because the concentration overpotential increases due to the decrease in the oxygen molar concentration at high-temperature. Figure 3 shows the results of Class8 driving simulation with each MEA adapted to the FC stack. In the MIRAI-MEA shown in Figure 3(a), a combination of 4-FC stack systems and 5-cooling systems is optimal. With this combination, the FC cell temperature can be controlled below 95°C. Figure 3(b) shows the analysis results of the FC stack using PBI-MEA. As shown in Figure 2(b), the PBI-MEA has a large overpotential, so a combination of 10-FC stack systems and 5-cooling systems is required to meet the request power. The current PBI-MEA’s performance cannot show the merits of non-humidified high-temperature operation. Figure 3(c) shows the analysis results of the FC stack using the Virtual HT-MEA. Stable operation is possible with 4-FC stack systems and 2-cooling systems. This means that 3-cooling systems can be reduced compared to the MIRAI-MEA’s system. This is because the cooling performance is improved due to the larger temperature difference between the outside air and the FC stacks. Reference (1)S.Hasegawa, et al., ECS Transactions,104, (2021) (2)S.Hasegawa, et al., ECS Transactions,109, (2022) (3)C.Zhang, et al., Transportation Research,Part D95, (2021) (4)A.R.Korsgaad, et al., Journal of Power Sources,162, (2006) (5)C.-Y.Chen, et al., Journal of Power Sources,195, (2010) (6)M.G.Waller, et al., International Journal of Hydrogen Energy,41, (2016) Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (1) , 108
Proposal and Fundamental Investigation of Energy Storage and Hydrogen Supply System Using the Lithium
In recent years, variable renewable energy such as solar power and wind power spreads rapidly. At the same time, taking measures against output fluctuations and utilization of surplus electricity become important issues. Conversion of electricity to hydrogen is considered as one of the utilizations of surplus electricity [1]. The hydrogen is stored and can be supplied to the fuel cell vehicles according to demand, regardless of weather or time. However, the disadvantage of hydrogen is its low energy density. Although several methods have been investigated for high-density storage of hydrogen, there are still issues about safety, energy loss, cost, and durability [2]. In this study, we propose a new energy storage and hydrogen supply method using lithium (Figure 1). The surplus electricity can be converted by the following reaction, and the energy is stored as the lithium. Li+ + e- → Li (-3.04 V vs. SHE) (1) 4LiOH → 4Li+ + O2 + 2H2O + 4e- (0.41 V vs. SHE) (2) The lithium can be stored at room temperature and pressure, and its volumetric energy is higher than that of conventional hydrogen storage methods. When hydrogen is needed, the system can be discharged to produce hydrogen by the following reaction. Li → Li+ + e- (-3.04 V vs. SHE) (3) 2Li+ + 2H2O + 2e-→ 2LiOH + H2 (-0.82 V vs. SHE) (4) Since the lithium is highly reactive, discharge reaction with water occurs, and hydrogen can be produced without energy input from the outside. As shown in Equation (2) and Equation (4), charge and discharge reactions at the cathode are different, and this system combines the characteristics of lithium-air cell [3] and lithium-water cell [4]. This system has a potential to utilize the surplus electricity; but it has not been fully evaluated from the viewpoint of hydrogen production [5]. Therefore, present study investigated the characteristics of the discharge reaction and hydrogen production behavior. Figure 2 shows experimental cell. The composite anode was water-stable and had a multilayer structure [6]. LATP (Li1+x+yAlxTi2-xSiyP3-y, Ohara Co., Kanagawa, Japan), which is a water-stable lithium-ion-conducting glass ceramic, was used, along with PEO18LiTFSI as the organic electrolyte. The lithium foil and polyethylene oxide (PEO) membrane were sealed inside the cell to prevent direct contact with water vapor and oxygen. Since the cell resistance depends on the temperature, the composite anode was kept at 70°C. For the cathode, glassy carbon rod was used. Figure 3 shows current-voltage (I-V) characteristics. The cathode potential at low-current discharge is higher than theoretical value (-0.82 V). It was caused by reaction with dissolved oxygen in the electrolyte. As the current value is increased, the cathode potential drops sharply, and many bubbles were observed on the cathode end face. It is thought that oxygen concentration overvoltage increased significantly and the discharge reaction with water (hydrogen production as shown in Equation (4)) was occurred. The volume of the produced bubble was measured with using a sealed cathode and adding a liquid level gauge (not shown in Figure 2). As a result, the measured volume showed good agreement with the theoretical hydrogen volume produced by the reaction of Equation (4). It is considered that the reaction shifts to hydrogen production and the effect of dissolved oxygen can be negligible at sufficiently low cathode potential (i.e. high current discharge). The efficiency of this system was estimated by using the obtained experimental results. Generated electricity and enthalpy of produced hydrogen was calculated. When a 20 μA discharge test was conducted by using experimental cell, the discharge efficiency and conversion rate to hydrogen were 30% and 39%, respectively. For comparison, the experimental cell was converted to the lithium-air battery mode and discharged at 20 μA. The discharge efficiency was 56%. Considering the conversion ratio of lithium to electricity and hydrogen, the proposed hydrogen supply system using the lithium can utilize the variable renewable energy. References: [1] Y. Meiling et al., Renew. Sustain. Energy Rev., 46, 111180 (2021) [2] I.A. Hassan et al., Renewable Sustainable Energy Rev., 149, 111311 (2021) [3] S. Uemura et al., ECS Trans., 58-12, 15-20 (2019) [4] N. Shuster, Proceedings of the 34th International Power Sources Symposium, 118-123 (1990) [5] Y. Wang et al., ChemSusChem, 3, 571-574 (2010) [6] T. Zhang et al., J. Electrochem. Soc., 155, A965 (2008) Figure 1
- 22 December 2023
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2023-02 (1) , 108
Proposal and Fundamental Investigation of Energy Storage and Hydrogen Supply System Using the Lithium
In recent years, variable renewable energy such as solar power and wind power spreads rapidly. At the same time, taking measures against output fluctuations and utilization of surplus electricity become important issues. Conversion of electricity to hydrogen is considered as one of the utilizations of surplus electricity [1]. The hydrogen is stored and can be supplied to the fuel cell vehicles according to demand, regardless of weather or time. However, the disadvantage of hydrogen is its low energy density. Although several methods have been investigated for high-density storage of hydrogen, there are still issues about safety, energy loss, cost, and durability [2]. In this study, we propose a new energy storage and hydrogen supply method using lithium (Figure 1). The surplus electricity can be converted by the following reaction, and the energy is stored as the lithium. Li+ + e- → Li (-3.04 V vs. SHE) (1) 4LiOH → 4Li+ + O2 + 2H2O + 4e- (0.41 V vs. SHE) (2) The lithium can be stored at room temperature and pressure, and its volumetric energy is higher than that of conventional hydrogen storage methods. When hydrogen is needed, the system can be discharged to produce hydrogen by the following reaction. Li → Li+ + e- (-3.04 V vs. SHE) (3) 2Li+ + 2H2O + 2e-→ 2LiOH + H2 (-0.82 V vs. SHE) (4) Since the lithium is highly reactive, discharge reaction with water occurs, and hydrogen can be produced without energy input from the outside. As shown in Equation (2) and Equation (4), charge and discharge reactions at the cathode are different, and this system combines the characteristics of lithium-air cell [3] and lithium-water cell [4]. This system has a potential to utilize the surplus electricity; but it has not been fully evaluated from the viewpoint of hydrogen production [5]. Therefore, present study investigated the characteristics of the discharge reaction and hydrogen production behavior. Figure 2 shows experimental cell. The composite anode was water-stable and had a multilayer structure [6]. LATP (Li1+x+yAlxTi2-xSiyP3-y, Ohara Co., Kanagawa, Japan), which is a water-stable lithium-ion-conducting glass ceramic, was used, along with PEO18LiTFSI as the organic electrolyte. The lithium foil and polyethylene oxide (PEO) membrane were sealed inside the cell to prevent direct contact with water vapor and oxygen. Since the cell resistance depends on the temperature, the composite anode was kept at 70°C. For the cathode, glassy carbon rod was used. Figure 3 shows current-voltage (I-V) characteristics. The cathode potential at low-current discharge is higher than theoretical value (-0.82 V). It was caused by reaction with dissolved oxygen in the electrolyte. As the current value is increased, the cathode potential drops sharply, and many bubbles were observed on the cathode end face. It is thought that oxygen concentration overvoltage increased significantly and the discharge reaction with water (hydrogen production as shown in Equation (4)) was occurred. The volume of the produced bubble was measured with using a sealed cathode and adding a liquid level gauge (not shown in Figure 2). As a result, the measured volume showed good agreement with the theoretical hydrogen volume produced by the reaction of Equation (4). It is considered that the reaction shifts to hydrogen production and the effect of dissolved oxygen can be negligible at sufficiently low cathode potential (i.e. high current discharge). The efficiency of this system was estimated by using the obtained experimental results. Generated electricity and enthalpy of produced hydrogen was calculated. When a 20 μA discharge test was conducted by using experimental cell, the discharge efficiency and conversion rate to hydrogen were 30% and 39%, respectively. For comparison, the experimental cell was converted to the lithium-air battery mode and discharged at 20 μA. The discharge efficiency was 56%. Considering the conversion ratio of lithium to electricity and hydrogen, the proposed hydrogen supply system using the lithium can utilize the variable renewable energy. References: [1] Y. Meiling et al., Renew. Sustain. Energy Rev., 46, 111180 (2021) [2] I.A. Hassan et al., Renewable Sustainable Energy Rev., 149, 111311 (2021) [3] S. Uemura et al., ECS Trans., 58-12, 15-20 (2019) [4] N. Shuster, Proceedings of the 34th International Power Sources Symposium, 118-123 (1990) [5] Y. Wang et al., ChemSusChem, 3, 571-574 (2010) [6] T. Zhang et al., J. Electrochem. Soc., 155, A965 (2008) Figure 1
- Open Access
- 1 December 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (12) , 124510
Component Analysis of Oxygen Transport Resistance Increased due to Water Accumulated in a PEFC
To increase the power output of polymer electrolyte fuel cells, care in the water management is important. This study extends the limiting current analysis to evaluate the effects of condensed water in the oxygen transport resistance. The resistance increase by water accumulation is separated into pressure-dependent and -independent components by introducing two indices determining the condensed water effects. The components approximately correspond to the transport resistances outside and inside of the catalyst layer (CL) respectively. The results show that both of the components increase from the low index region at 35 °C. At 80 °C, the increase in the pressure-dependent resistance is suppressed, while the pressure-independent resistance increases gradually as the current density increases. This gradual increase is confirmed in a cell with 1.0 mm wide channels, and the increase is suppressed with 0.3 mm wide channels. The observation of water distributions by a freezing method and cryo-SEM shows that there is ice at the interface between the micro-porous layer and CL only with the wider channel at 80 °C. These suggest that poorer contact of the interface under the wider channel allows condensed water to accumulate and expand at the interface, disturbing the oxygen transport to the CL.
- 1 December 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (12) , 124510
Open AccessComponent Analysis of Oxygen Transport Resistance Increased due to Water Accumulated in a PEFC
To increase the power output of polymer electrolyte fuel cells, care in the water management is important. This study extends the limiting current analysis to evaluate the effects of condensed water in the oxygen transport resistance. The resistance increase by water accumulation is separated into pressure-dependent and -independent components by introducing two indices determining the condensed water effects. The components approximately correspond to the transport resistances outside and inside of the catalyst layer (CL) respectively. The results show that both of the components increase from the low index region at 35 °C. At 80 °C, the increase in the pressure-dependent resistance is suppressed, while the pressure-independent resistance increases gradually as the current density increases. This gradual increase is confirmed in a cell with 1.0 mm wide channels, and the increase is suppressed with 0.3 mm wide channels. The observation of water distributions by a freezing method and cryo-SEM shows that there is ice at the interface between the micro-porous layer and CL only with the wider channel at 80 °C. These suggest that poorer contact of the interface under the wider channel allows condensed water to accumulate and expand at the interface, disturbing the oxygen transport to the CL.