Michael R. Schock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Michael R. Schock has a total of 51 co-authors. Here are the top co-authors by number of shared publications:
- Darren A. Lytle
Office of Research and Development (ORD), U.S. Environmental Protection Agency, 26 W. Martin Luther King Dr., Cincinnati, Ohio 45268, United States
10 shared publications - Jennifer Tully
US Environmental Protection Agency
5 shared publications - Michael K. DeSantis
US Environmental Protection Agency
5 shared publications - Jonathan B. Burkhardt
Office of Research and Development US Environmental Protection Agency Cincinnati Ohio USA
3 shared publications Simoni Triantafyllidou
Environmental Engineer, Water Infrastructure Div., Drinking Water Management Branch, and Center for Environmental Solutions and Emergency Response, US Environmental Protection Agency, 26 W. Martin Luther King Dr., Cincinnati, OH 45268
3 shared publications- Christina Bennett-Stamper
U.S. Environmental Protection Agency, Center for Environmental Solutions and Emergency Response, Water Infrastructure Division, 26 W. Martin Luther King Dr, Cincinnati, OH 45268, USA
2 shared publications
Latest Publications
- 13 November 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (6)
Drinking water buffer intensity simulator (BIS): Development and practical simulations
An established body of research over many decades has identified the importance of both bulk‐water and pipe scale surface microenvironment buffering to meet distribution system pH targets and reduce corrosivity toward metallic piping and components. Buffer intensity quantifies the ability of water to resist pH changes, and the greater the buffer intensity, the more resistant the water is to pH changes. To provide a practical tool for exploring buffer intensity, a buffer intensity simulator (BIS) was implemented in open‐source R code, incorporating typical chemical species (e.g., carbonate and orthophosphate) that contribute to drinking water buffer intensity along with temperature and ionic strength impacts. The BIS was verified against a parallel spreadsheet implementation and is publicly available at https://github.com/USEPA/BIS. Simulations were conducted to illustrate impacts related to buffer intensity using three practical scenarios: carbonate buffering in drinking waters, temperature impacts, and free ammonia presence from chloramine use and/or source water presence.
- 13 November 2024
- Published by Wiley in AWWA Water Science
- Vol. 6 (6)
Drinking water buffer intensity simulator (BIS): Development and practical simulations
An established body of research over many decades has identified the importance of both bulk‐water and pipe scale surface microenvironment buffering to meet distribution system pH targets and reduce corrosivity toward metallic piping and components. Buffer intensity quantifies the ability of water to resist pH changes, and the greater the buffer intensity, the more resistant the water is to pH changes. To provide a practical tool for exploring buffer intensity, a buffer intensity simulator (BIS) was implemented in open‐source R code, incorporating typical chemical species (e.g., carbonate and orthophosphate) that contribute to drinking water buffer intensity along with temperature and ionic strength impacts. The BIS was verified against a parallel spreadsheet implementation and is publicly available at https://github.com/USEPA/BIS. Simulations were conducted to illustrate impacts related to buffer intensity using three practical scenarios: carbonate buffering in drinking waters, temperature impacts, and free ammonia presence from chloramine use and/or source water presence.
- Open Access
- 22 January 2024
- Published by IWA Publishing in Journal of Water and Health
- Vol. 22 (2) , 296-308
An evaluation of properly operated NSF/ANSI-53 Pb certified drinking water filters in Benton Harbor, MI
Communities across the United States and particularly in the Midwest continue to grapple with the complications associated with aging infrastructure. This includes the presence of lead (Pb)-bearing plumbing components such as lead service lines, downstream galvanized iron pipes, and Pb/tin solder. The community of Benton Harbor, MI, experienced six Pb action level exceedances between 2018 and 2021, leading to increasing community concern and a request from the state of Michigan for the US Environmental Protection Agency involvement. Between 9 November and 17 December 2021, US EPA Region 5 and Office of Research and Development, along with the state of Michigan, conducted a water filter efficacy and Pb-nanoparticulate (<100 nm) study to evaluate the performance of NSF/ANSI-53 Pb-certified drinking water filters and the presence of nanoparticulate. In this study, a total of 199 properly installed and operated drinking water filters (combination of faucet mounted and pitcher) were tested in their residential locations. One hundred percent of the water filters were found to perform to the standard to which they were certified, with filtered drinking water Pb concentrations below 5 ppb (maximum observed was 2.5 ppb). In addition, Pb particulate was identified; however, discrete Pb-containing nanoparticles were not widely found or identified.
- 22 January 2024
- Published by IWA Publishing in Journal of Water and Health
- Vol. 22 (2) , 296-308
Open AccessAn evaluation of properly operated NSF/ANSI-53 Pb certified drinking water filters in Benton Harbor, MI
Communities across the United States and particularly in the Midwest continue to grapple with the complications associated with aging infrastructure. This includes the presence of lead (Pb)-bearing plumbing components such as lead service lines, downstream galvanized iron pipes, and Pb/tin solder. The community of Benton Harbor, MI, experienced six Pb action level exceedances between 2018 and 2021, leading to increasing community concern and a request from the state of Michigan for the US Environmental Protection Agency involvement. Between 9 November and 17 December 2021, US EPA Region 5 and Office of Research and Development, along with the state of Michigan, conducted a water filter efficacy and Pb-nanoparticulate (<100 nm) study to evaluate the performance of NSF/ANSI-53 Pb-certified drinking water filters and the presence of nanoparticulate. In this study, a total of 199 properly installed and operated drinking water filters (combination of faucet mounted and pitcher) were tested in their residential locations. One hundred percent of the water filters were found to perform to the standard to which they were certified, with filtered drinking water Pb concentrations below 5 ppb (maximum observed was 2.5 ppb). In addition, Pb particulate was identified; however, discrete Pb-containing nanoparticles were not widely found or identified.
- Open Access
- 17 March 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (2)
A holistic approach to lead pipe scale analysis: Importance, methodology, and limitations
With lead service lines (LSLs) remaining for decades to come, scale analyses are critical to helping limit lead exposure from drinking water. This laboratory has used an integrated suite of analytical techniques to characterize the elemental composition, mineral identification, and physical features of scales, helping the water industry to evaluate, predict, and reduce lead corrosion. The methods used in this laboratory to prepare and analyze the LSL scale, and guidance to achieving reliable and meaningful results, are described. Primary methods include the following: optical microscopy, powder X‐ray diffraction, inductively coupled plasma spectroscopy, X‐ray fluorescence, scanning electron microscopy with energy dispersive spectroscopy, combustion and coulometric analyses of C and S, and X‐ray absorption spectroscopy. Examples of associated pitfalls and ways to avoid them are provided, including pipe excavation/transport, sample preparation, analysis, and data interpretation. Illustrative examples are presented of practical scale analysis questions that could be answered by combinations of pipe scale analyses.
- 17 March 2022
- Published by Wiley in AWWA Water Science
- Vol. 4 (2)
Open AccessA holistic approach to lead pipe scale analysis: Importance, methodology, and limitations
With lead service lines (LSLs) remaining for decades to come, scale analyses are critical to helping limit lead exposure from drinking water. This laboratory has used an integrated suite of analytical techniques to characterize the elemental composition, mineral identification, and physical features of scales, helping the water industry to evaluate, predict, and reduce lead corrosion. The methods used in this laboratory to prepare and analyze the LSL scale, and guidance to achieving reliable and meaningful results, are described. Primary methods include the following: optical microscopy, powder X‐ray diffraction, inductively coupled plasma spectroscopy, X‐ray fluorescence, scanning electron microscopy with energy dispersive spectroscopy, combustion and coulometric analyses of C and S, and X‐ray absorption spectroscopy. Examples of associated pitfalls and ways to avoid them are provided, including pipe excavation/transport, sample preparation, analysis, and data interpretation. Illustrative examples are presented of practical scale analysis questions that could be answered by combinations of pipe scale analyses.
- 1 February 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 148 (2) , 07021023
Closure to “Framework for Modeling Lead in Premise Plumbing Systems Using EPANET” by Jonathan B. Burkhardt, Hyoungmin Woo, James Mason, Feng Shang, Simoni Triantafyllidou, Michael R. Schock, Darren Lytle, and Regan Murray
Sponsored by the Environmental & Water Resources Institute (EWRI)
- 1 February 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 148 (2) , 07021023
Closure to “Framework for Modeling Lead in Premise Plumbing Systems Using EPANET” by Jonathan B. Burkhardt, Hyoungmin Woo, James Mason, Feng Shang, Simoni Triantafyllidou, Michael R. Schock, Darren Lytle, and Regan Murray
Sponsored by the Environmental & Water Resources Institute (EWRI)
- 1 September 2021
- Published by Wiley in AWWA Water Science
- Vol. 3 (5) , e1255-1255
Rapid and simple lead service line detection screening protocol using water sampling
Many water systems are challenged with uncertainty regarding service line material type. This work investigated using a simple drinking water flushed sampling approach and a more complicated and invasive sequential profile sampling approach to predict whether homes had an existing lead service line (LSL). Homes that never had an LSL (control groups) and homes with LSLs (study groups) in two communities having different degrees of corrosion control were sampled. Using control groups' results, community‐specific “threshold” lead levels were determined and compared to results from study groups. The flushed sampling maximum lead concentration (FMC) of lead accurately predicted 100% and 60% of LSL sites for the community with poor and good corrosion control, respectively. The weighted average sequential profile lead concentration (WASLC) increased the 40% not identified as LSL sites by fully flushed samples to 100%. The WASLC closely followed by the maximum sequential profile lead concentration were most reliable in identifying LSLs.
- 1 September 2021
- Published by Wiley in AWWA Water Science
- Vol. 3 (5) , e1255-1255
Rapid and simple lead service line detection screening protocol using water sampling
Many water systems are challenged with uncertainty regarding service line material type. This work investigated using a simple drinking water flushed sampling approach and a more complicated and invasive sequential profile sampling approach to predict whether homes had an existing lead service line (LSL). Homes that never had an LSL (control groups) and homes with LSLs (study groups) in two communities having different degrees of corrosion control were sampled. Using control groups' results, community‐specific “threshold” lead levels were determined and compared to results from study groups. The flushed sampling maximum lead concentration (FMC) of lead accurately predicted 100% and 60% of LSL sites for the community with poor and good corrosion control, respectively. The weighted average sequential profile lead concentration (WASLC) increased the 40% not identified as LSL sites by fully flushed samples to 100%. The WASLC closely followed by the maximum sequential profile lead concentration were most reliable in identifying LSLs.
- 1 September 2021
- Published by Wiley in AWWA Water Science
- Vol. 3 (5) , e1250
Theoretical equilibrium lead(II) solubility revisited: Open source code and practical relationships
A theoretical equilibrium lead(II) (Pb(II)) solubility model coded in Fortran (LEADSOL) was updated and implemented in open source R code, verified against LEADSOL output, and used to simulate theoretical equilibrium total soluble Pb(II) (TOTSOLPb) concentrations under a variety of practical scenarios. The developed R code file (app.R) is publicly available for download at GitHub (https://github.com/USEPA/TELSS) along with instructions to run the R code locally, allowing the user to explore Pb(II) solubility by selecting desired simulation conditions (e.g., water quality, equilibrium constants, and Pb(II) solids to consider). In addition, the R code serves as a reproducible baseline for alternative model development and future model improvements, allowing users to update, modify, and share the R code to meet their needs. Using the R code, several solubility diagrams were generated to highlight practical relationships related to TOTSOLPb concentrations, including the impact of pH and dissolved inorganic carbon, orthophosphate, sulfate, and chloride concentrations.
- 1 September 2021
- Published by Wiley in AWWA Water Science
- Vol. 3 (5) , e1250
Theoretical equilibrium lead(II) solubility revisited: Open source code and practical relationships
A theoretical equilibrium lead(II) (Pb(II)) solubility model coded in Fortran (LEADSOL) was updated and implemented in open source R code, verified against LEADSOL output, and used to simulate theoretical equilibrium total soluble Pb(II) (TOTSOLPb) concentrations under a variety of practical scenarios. The developed R code file (app.R) is publicly available for download at GitHub (https://github.com/USEPA/TELSS) along with instructions to run the R code locally, allowing the user to explore Pb(II) solubility by selecting desired simulation conditions (e.g., water quality, equilibrium constants, and Pb(II) solids to consider). In addition, the R code serves as a reproducible baseline for alternative model development and future model improvements, allowing users to update, modify, and share the R code to meet their needs. Using the R code, several solubility diagrams were generated to highlight practical relationships related to TOTSOLPb concentrations, including the impact of pH and dissolved inorganic carbon, orthophosphate, sulfate, and chloride concentrations.
- Open Access
- 16 December 2020
- Published by Elsevier in Environment International
- Vol. 146, 106259
Variability and sampling of lead (Pb) in drinking water: Assessing potential human exposure depends on the sampling protocol
- 16 December 2020
- Published by Elsevier in Environment International
- Vol. 146, 106259
Open AccessVariability and sampling of lead (Pb) in drinking water: Assessing potential human exposure depends on the sampling protocol
- 1 December 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 146 (12) , 04020094
Framework for Modeling Lead in Premise Plumbing Systems Using EPANET
The lead contamination of drinking water in homes and buildings remains an important public health concern. In order to assess strategies to measure and reduce exposure to lead from drinking water, models are needed that incorporate the multiple factors affecting lead concentrations in premise plumbing systems (PPS). In this study, the use of EPANET, a commonly used hydraulic and water quality model for water distribution systems, was assessed for its ability to predict lead concentrations in PPS. The model was calibrated and validated against data collected from multiple experiments in the EPA’s Home Plumbing Simulator that contained a lead service line and other lead sources. The EPANET’s first-order saturation kinetics model was used to simulate the dissolution of lead in the lead service line. A version of EPANET was developed to include one-dimensional mass dispersion. Modeling results were compared to experimental data, and recommendations were made to improve the EPANET-based modeling framework for predicting lead concentrations in PPS.
- 1 December 2020
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 146 (12) , 04020094
Framework for Modeling Lead in Premise Plumbing Systems Using EPANET
The lead contamination of drinking water in homes and buildings remains an important public health concern. In order to assess strategies to measure and reduce exposure to lead from drinking water, models are needed that incorporate the multiple factors affecting lead concentrations in premise plumbing systems (PPS). In this study, the use of EPANET, a commonly used hydraulic and water quality model for water distribution systems, was assessed for its ability to predict lead concentrations in PPS. The model was calibrated and validated against data collected from multiple experiments in the EPA’s Home Plumbing Simulator that contained a lead service line and other lead sources. The EPANET’s first-order saturation kinetics model was used to simulate the dissolution of lead in the lead service line. A version of EPANET was developed to include one-dimensional mass dispersion. Modeling results were compared to experimental data, and recommendations were made to improve the EPANET-based modeling framework for predicting lead concentrations in PPS.
- 26 October 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (22) , 14302-14311
Orthophosphate Interactions with Destabilized PbO2 Scales
This research presents two case studies in which a change in the disinfectant from free chlorine to chloramine caused an increase in lead corrosion. In both systems, the predominantly tetravalent lead (PbO2) scales destabilized as a result of disinfectant change. Orthophosphate corrosion control was used in both systems, and the effect of this treatment chemical on the destabilized PbO2 scales was examined. The absence of chemical reactivity between PbO2 and phosphorus is well known, and this research confirms that phosphorus does not interact with the legacy PbO2 scales. Instead, phosphorus and calcium were found to permeate through the destabilized PbO2 material and react with divalent lead [Pb(II)] at the surface of a basal litharge (PbO) layer. This reaction precipitated a crystalline lead phosphate in both systems, which could not be specifically identified by any known powder diffraction files. Further analysis suggested that the compound formed was not the typically modeled hydroxypyromorphite but rather a calcium-substituted hydroxypyromorphite. During scale formation, calcium is frequently bound to the Pb(II) phosphate crystal lattice structure, causing measurable crystal lattice distortion in powder X-ray diffraction patterns. The results of this study illustrate the longevity of legacy scales and how disequilibrium compounds persist long after treatment changes have been made.
- 26 October 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (22) , 14302-14311
Orthophosphate Interactions with Destabilized PbO2 Scales
This research presents two case studies in which a change in the disinfectant from free chlorine to chloramine caused an increase in lead corrosion. In both systems, the predominantly tetravalent lead (PbO2) scales destabilized as a result of disinfectant change. Orthophosphate corrosion control was used in both systems, and the effect of this treatment chemical on the destabilized PbO2 scales was examined. The absence of chemical reactivity between PbO2 and phosphorus is well known, and this research confirms that phosphorus does not interact with the legacy PbO2 scales. Instead, phosphorus and calcium were found to permeate through the destabilized PbO2 material and react with divalent lead [Pb(II)] at the surface of a basal litharge (PbO) layer. This reaction precipitated a crystalline lead phosphate in both systems, which could not be specifically identified by any known powder diffraction files. Further analysis suggested that the compound formed was not the typically modeled hydroxypyromorphite but rather a calcium-substituted hydroxypyromorphite. During scale formation, calcium is frequently bound to the Pb(II) phosphate crystal lattice structure, causing measurable crystal lattice distortion in powder X-ray diffraction patterns. The results of this study illustrate the longevity of legacy scales and how disequilibrium compounds persist long after treatment changes have been made.
- 22 October 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (21) , 13672-13679
Lead Particle Size Fractionation and Identification in Newark, New Jersey’s Drinking Water
Following a pH reduction in their drinking water over a span of more than 20 years, the City of Newark, New Jersey, has struggled with elevated lead (Pb) release from Pb service lines and domestic plumbing in the zone fed by the Pequannock Water Treatment Plant. In response, Newark initiated orthophosphate addition and provided faucet-mounted point-of-use (POU) filters and pitcher filters certified for Pb and particulate reduction under NSF/ANSI Standards 53 and 42 to residential homes in that zone. Water chemistry analysis and size fractionation sampling were performed at four of these houses. Analysis of the particulate material retained by the fractionation filters revealed that Pb was dominantly present in the water as fine Pb(II) orthophosphate particles. A considerable amount of the particulates occurred as a nanoscale fraction that sometimes passed through the POU faucet or pitcher filtration units. Scanning electron microscopy, transmission electron microscopy, and energy-dispersive spectroscopy analyses showed that the nanoparticles (5(PO4)3Cl. Electron diffraction and X-ray analyses supported the presence of hydroxypyromorphite and chloropyromorphite nanoparticles and the size range estimates from the imaging. This research confirmed that nonadherent Pb(II)-orthophosphate nanoparticles were an important form of Pb in drinking water in the Pequannock water quality zone of Newark.
- 22 October 2020
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 54 (21) , 13672-13679
Lead Particle Size Fractionation and Identification in Newark, New Jersey’s Drinking Water
Following a pH reduction in their drinking water over a span of more than 20 years, the City of Newark, New Jersey, has struggled with elevated lead (Pb) release from Pb service lines and domestic plumbing in the zone fed by the Pequannock Water Treatment Plant. In response, Newark initiated orthophosphate addition and provided faucet-mounted point-of-use (POU) filters and pitcher filters certified for Pb and particulate reduction under NSF/ANSI Standards 53 and 42 to residential homes in that zone. Water chemistry analysis and size fractionation sampling were performed at four of these houses. Analysis of the particulate material retained by the fractionation filters revealed that Pb was dominantly present in the water as fine Pb(II) orthophosphate particles. A considerable amount of the particulates occurred as a nanoscale fraction that sometimes passed through the POU faucet or pitcher filtration units. Scanning electron microscopy, transmission electron microscopy, and energy-dispersive spectroscopy analyses showed that the nanoparticles (5(PO4)3Cl. Electron diffraction and X-ray analyses supported the presence of hydroxypyromorphite and chloropyromorphite nanoparticles and the size range estimates from the imaging. This research confirmed that nonadherent Pb(II)-orthophosphate nanoparticles were an important form of Pb in drinking water in the Pequannock water quality zone of Newark.