SKShin-Ichiro Kuroki

Shin-Ichiro Kuroki

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Shin-Ichiro Kuroki has a total of 48 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Designing and fabrication of 4H-SiC neutron sensors for boron neutron capture therapy

    by Vu Thi Ha, Tatsuya Meguro, Kazutoshi Kojima, Hiroki Tanaka, Shin-Ichiro Kuroki

    In this work, 4H-SiC neutron sensors (NSs) for boron neutron capture therapy were designed, fabricated, and tested under ultraviolet (UV) light and neutron irradiation. A pinned photodiode (PPD) structure and a parasitic bipolar junction transistor were designed for the NS region. A large neutron conversion layer of 500 µm × 500 µm was formed on the PPD area by 10 B ions implanted into a 700 nm Al layer. The output characteristics under UV light tests have demonstrated the functional operation of the 4T-active pixel sensor structure of SiC NSs. No significant degradation was observed under the E-3 tube, with a total neutron fluence of 1.8 × 10 9 n cm −2 . The results, which were obtained under the heavy water neutron irradiation facility condition with a high neutron flux in the range of 1×10 9 n c m − 2 s − 1 and a cycle of 1.0 s, demonstrated the neutron detection capability of the 4H-SiC NS prototypes, despite signs of degradation due to neutron-induced damage and the TID effects.

  • Microstructural characteristics of Ni and Ni/Nb ohmic contacts on n-type 4H-SiC

    by Nguyen Anh Dung, Seiji Ishikawa, Tomonori Maeda, Hiroshi Sezaki, Shin-Ichiro Kuroki

    The microstructures of Ni and Ni/Nb ohmic contacts on 4H-SiC substrates were investigated. Ni-based and Ni/Nb ohmic contacts were successfully formed by rapid thermal annealing for 3 min in N 2 ambient. The Ni/Nb/4H-SiC sample exhibited a range of total resistance of 7.1–7.7 Ω, smaller than 16–24 Ω of the Ni/4H-SiC sample. A higher distribution of carbon atoms was observed in the Ni/4H-SiC sample (95% on the surface and 50% at the interface), confirmed by SEM-EDS and XPS results. Well-controlled carbon atoms, by forming Nb x C y compounds as shown in XRD results, lead to the rougher surface (6.39 nm) of the Ni/Nb/4H-SiC sample compared to the 5.06 nm of the Ni/4H-SiC sample. C-AFM results indicated that smaller variations in the peak current (0.245 nA) and better conductivity (3.6 nA) were achieved for the Ni/Nb/4H-SiC sample. The removal of excess carbon atoms in the presence of Nb enhanced the electrical properties.


  • Open Access

    In Situ Measurement of the Gain Stage of a SiC JFET Operational Amplifier under Gamma Ray Irradiation

    by Masayuki Yamamoto, Takanori Amamiya, Akinori Takeyama, Ryuya Hirose, Mikihiro Yuzuriha, Koji Nakayama, Hitoshi Umezawa, Takeharu Kuroiwa, Takahide Sato, Takahiro Makino, et al.

    In this study, we conducted in-situ measurements on a SiC JFET operational amplifier operating under gamma-ray irradiation. It shows that the radiation did not affect the output waveform or voltage gain, but shifted the output offset voltage. This shift may result mainly from holes generated by irradiation and trapped in the oxide layer, which modified the I-V characteristics of the level-shifting diodes. It can be compensated by applying bias voltage, and it may also be prevented by optimizing the diode structure and/or circuit topology.

  • Open Access

    Fabrication of the Planar SiC Gate-all-Around JFET with Channel Dose Modulation

    by Takanori Amamiya, Masayuki Yamamoto, Hitoshi Umezawa, Koji Nakayama, Takeharu Kuroiwa, Shinichiro Kuroki, Yasunori Tanaka

    Currently, silicon carbide (SiC) is widely recognized as a wide bandgap semiconductor, with expanding applications in harsh environments, such as high temperature and radiation exposure. In this study, we fabricated a planar structure 4H-SiC gate-all-around junction field-effect transistor (JFET), wherein the channel region is formed through ion implantation at varying doses. We successfully produced both normally-on and normally-off JFETs. Moreover, we constructed a JFET commonsource amplifier. The amplifiers achieved a maximum gain of -226.7 (47.1 dB) at a supply voltage of VDD = 30 V.


  • High-temperature reliability of Ni/Ti/Nb ohmic contact on p-type 4H-SiC

    by Vu Thi Ha, Vuong Van Cuong, Takamichi Miyazaki, Shin-Ichiro Kuroki

    In this study, the thermal stability of Ni/Ti and Ni/Ti/Nb ohmic contact on p-type 4H-SiC were investigated for 100 h at 400 °C in N2 environment. The results demonstrated that lower contact resistance and higher thermal stability could be achieved with the Ni/Ti/Nb candidate. After 100 h aging, the specific contact resistance of the Ni/Ti/Nb sample slightly increased from 2.56 × 10−3 to 3.04 × 10−3 Ω cm2. X-ray diffraction results showed that Ni2Si, Ti3SiC2 and Nb6C5 compounds contributed to low contact resistance and high-temperature reliability. By adding Nb, the surface of the Ni/Ti/Nb/4H-SiC ohmic contact becomes smoother than that of the Ni/Ti/4H-SiC ohmic contact. The metal/4H-SiC interface of the ohmic contacts was observed after 100 h aging by using TEM measurement. For the Ni/Ti/Nb sample, the excess carbon atoms were collected by the formation of Nb–C compounds and then increased high temperature reliability and reduced contact resistivity.


  • Open Access

    Thermal Stability of Gate Driver Circuits Based on 4H-SiC MOSFETs at 300°C for High-Power Applications

    by Vuong Van Cuong, Tatsuya Meguro, Seiji Ishikawa, Tomonori Maeda, Hiroshi Sezaki, Shin-Ichiro Kuroki

    The operation and reliability of gate driver circuits based on 4H-SiC MOSFETs at temperatures up to 300∘ C were reported. Due to the advantages of 4H-SiC MOSFETs, the driver circuit can overcome limitations in complicated circuit design and power dissipation associated with SiC BJT-based technology. Additionally, the stability of implanted 4H-SiC resistors can address the reliability issues of SiC CMOS-based driver circuits, which are caused by the instability in the threshold voltage of P-channel SiC MOSFETs. In this study, the switching characteristics of the gate driver circuit were improved when the ambient temperature increased. The decrease of threshold voltage and increase of carrier mobility of the 4H-SiC MOSFETs may account for the improvement in switching characteristics of the gate driver circuit. The output signal of the gate driver circuit still showed proper characteristics after 600 min of continuous operation at 300∘ C in an air ambient. These results indicate that the gate driver circuit based on 4H-SiC MOSFET technology is promising to apply for high power applications.


  • Open Access

    4H-SiC Radiation Hardened Static Random Access Memory

    by Shin-Ichiro Kuroki, Toya Kai, Taisei Ozaki, Kazutoshi Kojima, Akinori Takeyama, Takeshi Ohshima, Yasunori Tanaka

    4H-SiC static random-access memory (SRAM) was suggested and demonstrated for extreme-environment applications. The 4H-SiC SRAMs show the proper memory states with high static noise margins (SNMs). After exposure to a significant gamma-ray radiation of 810 kGy, the SRAMs continued to function effectively, maintaining positive SNM values necessary for proper memory operation. After the gamma-ray radiation, the SRAM operation was tested at high temperature, and it continued to function normally even at temperatures as high as 500°C.


  • Thermal stability of TiN gate electrode for 4H-SiC MOSFETs and integrated circuits

    by Vuong Van Cuong, Tatsuya Meguro, Seiji Ishikawa, Tomonori Maeda, Hiroshi Sezaki, Shin-Ichiro Kuroki

    In this research, the thermal stability of single-stage amplifiers based on a 4H-SiC MOSFET with a TiN gate electrode was investigated. The results show that after 100 h aging at 400 °C in N2 ambient, the amplifier maintained good performance with stable voltage gain. The thermal stability of the amplifier is attributed to the stability of Ni/Nb/4H-SiC source/drain ohmic contact, implanted load resistor, and MOS structure with the TiN gate electrode. The results obtained from the 4H-SiC MOS structure show that the interface trap density at the SiO2/SiC decreases during the aging process. While the gate leakage current of the capacitor based on the Al gate electrode increases, it remains stable in structures with TiN gate electrodes after 100 h aging. The results obtained in this study indicate that TiN is promising for the gate electrode of 4H-SiC MOSFETs for high-temperature applications.


  • Open Access

    4H-SiC 64 pixels CMOS image sensors with 3T/4T-APS arrays

    by Tatsuya Meguro, Masayuki Tsutsumi, Akinori Takeyama, Takeshi Ohshima, Yasunori Tanaka, Shin-Ichiro Kuroki

    For radiation-hardened CMOS image sensors (CIS), 4H-SiC 64 pixel array CIS were developed, and real time imaging with an operation frequency of 30 Hz was demonstrated. Two types of pixel arrays with a 3-transistor active pixel sensor (3T-APS) and a 4-transistor active pixel sensor (4T-APS) were fabricated with SiC MOSFETs, UV photodiodes and 3-layered Al interconnections. The SiC pixel arrays were combined with peripheral circuits and an optical lens, and SiC 64 pixel CIS with 3T-/4T-APS arrays were developed.


  • Open Access

    Impact of interface oxide type on the gamma radiation response of SiC TTL ICs

    by Alex Metreveli, Van Vuong Cuong, Shin-Ichiro Kuroki, Kenichi Tanaka, Carl-Mikael Zetterling

    In this study, we investigate the impact of Gamma Radiation on 4H Silicon Carbide (SiC) Transistor-Transistor Logic (TTL) integrated circuits (ICs), particularly focusing on inverters processed with distinct types of interface oxides: Thermally Grown, Chemical Vapor Deposition, and Atomic Layer Deposition. This research was conducted using a 60Co source at Hiroshima University, applying varied radiation doses (17.9 rad(Si)/s, 7.3 rad(Si)/s, and 2.47 rad(Si)/s) to assess the resilience of the SiC inverters under these conditions. Our findings reveal that thermal oxides (Batch 1: W1 and W2) demonstrate higher radiation resilience compared to ALD and CVD interface oxides (Batch 2: W3 and W4), attributable to their denser structure and fewer defects. The study also identifies that while the inverters exhibit marginal degradation at gamma doses nearing 700 krad (under 6%), the most critical operational state is the passive mode (VCC = VIN = 0 V), where the build-up of induced charge in the oxide and interface may lead to early IC degradation of the noise margins. The outcomes from this research provide insights into the processing flow and enhancement of SiC electronics. Our results underscore the potential of SiC-based ICs in environments with high radiation levels, such as space missions, nuclear reactors, and medical applications, due to their enhanced radiation tolerance.