Chiarasole Fiamozzi Zignani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chiarasole Fiamozzi Zignani has a total of 161 co-authors. Here are the top co-authors by number of shared publications:
- Gianluca De Marzi
NUC department, ENEA, Frascati, Italy
14 shared publications - Luigi Muzzi
NUC department, ENEA, Frascati, Italy
13 shared publications - Aldo Di Zenobio
Superconductivity Laboratory, ENEA, Frascati, Italy
7 shared publications - Antonio della Corte
ENEA, Frascati, Italy
7 shared publications - Simonetta Turtu
Superconductivity Laboratory, ENEA, Frascati, Italy
7 shared publications - Giuseppe Messina
National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA)
5 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (11) , 115005
Technical innovation assessment of SiC varistors for quench protection of DEMO toroidal field superconducting coils
This paper investigates the feasibility and technical advantages of utilizing silicon carbide (SiC) varistors for the energy extraction systems of the toroidal field coils (TFC) in case of a quench in the present European DEMO fusion reactor design. Varistors offer a non-linear voltage-current response that provides faster discharge times and voltage limiting behavior compared to traditional linear resistors. Using the Metrosil 9000 series varistors as a baseline, comprehensive discharge simulations were conducted for both 8 and 16 Fast Discharge Unit configurations. The study integrates electrical transient simulations to assess clamping voltages and advanced thermal modeling to evaluate the corresponding stress on the superconducting cables. Specifically, the quench propagation and the hotspot temperature evolution were investigated using both conservative adiabatic calculations and detailed transient thermal-hydraulic modeling (via the 4 C code). Results indicate that, in normal operation mode, while voltage limits are successfully managed, the Joule integral limit is currently exceeded. Consequently, the thermal-hydraulic analysis reveals that jacket hotspot temperatures surpass the 150 K acceptance limit with varistor-based discharges, inducing higher thermal stresses than traditional resistors. This highlights a dual requirement: the need for varistor material optimizations in the case of DEMO TFCs–specifically targeting a lower non-linearity parameter ( β < 0.3 )— , in order to fully realize the benefits of SiC varistors for high-energy fusion applications, and a potential reassessment of the conductor design, in terms of both copper stabilizer amount and cross-section geometry, to improve current sharing during the discharge and conductor stability against small disturbances.
- 1 November 2026
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 39 (11) , 115005
Open AccessTechnical innovation assessment of SiC varistors for quench protection of DEMO toroidal field superconducting coils
This paper investigates the feasibility and technical advantages of utilizing silicon carbide (SiC) varistors for the energy extraction systems of the toroidal field coils (TFC) in case of a quench in the present European DEMO fusion reactor design. Varistors offer a non-linear voltage-current response that provides faster discharge times and voltage limiting behavior compared to traditional linear resistors. Using the Metrosil 9000 series varistors as a baseline, comprehensive discharge simulations were conducted for both 8 and 16 Fast Discharge Unit configurations. The study integrates electrical transient simulations to assess clamping voltages and advanced thermal modeling to evaluate the corresponding stress on the superconducting cables. Specifically, the quench propagation and the hotspot temperature evolution were investigated using both conservative adiabatic calculations and detailed transient thermal-hydraulic modeling (via the 4 C code). Results indicate that, in normal operation mode, while voltage limits are successfully managed, the Joule integral limit is currently exceeded. Consequently, the thermal-hydraulic analysis reveals that jacket hotspot temperatures surpass the 150 K acceptance limit with varistor-based discharges, inducing higher thermal stresses than traditional resistors. This highlights a dual requirement: the need for varistor material optimizations in the case of DEMO TFCs–specifically targeting a lower non-linearity parameter ( β < 0.3 )— , in order to fully realize the benefits of SiC varistors for high-energy fusion applications, and a potential reassessment of the conductor design, in terms of both copper stabilizer amount and cross-section geometry, to improve current sharing during the discharge and conductor stability against small disturbances.
- 6 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Analysis of Silicon Carbide Varistors for Fast Discharge Units of DEMO Toroidal Field Superconducting Magnets in Case of a Quench
This work investigates innovative technologies for DEMOnstration power plant (DEMO) Fast Discharge Units (FDUs), in comparison with traditional temperature-dependent discharge resistors. The protection system for the DEMO Toroidal Field (TF) superconducting magnets is designed to respond to a quench, which is a rapid transition from the superconducting state to normal conduction, or other faults. This system helps prevent severe damage to the TF magnets, which can experience significant thermal and voltage stresses during a quench, due to the intervention of the FDUs. These stresses can damage the insulation and compromise the magnet's integrity. FDUs play a crucial role in rapidly discharging the magnetic energy stored in the magnets. Silicon Carbide (SiC) varistors within the FDU, with their nonlinear behavior, can significantly reduce the voltage peak across the TF magnet at fast discharge with respect to normal resistors. In the high current configuration, the DEMO TF magnet system is composed of 16 TF coils, with: a total inductance of 22.56 H, an operating current of 105 kA and a total magnetic energy stored of about 124 GJ. Maximum voltage limits for TF coils are 6 kV terminal-to-terminal and 3 kV terminal-to-ground. Performance of technologies are compared considering voltage and hotspot temperature.
- 6 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 36 (5) , 1-5
Analysis of Silicon Carbide Varistors for Fast Discharge Units of DEMO Toroidal Field Superconducting Magnets in Case of a Quench
This work investigates innovative technologies for DEMOnstration power plant (DEMO) Fast Discharge Units (FDUs), in comparison with traditional temperature-dependent discharge resistors. The protection system for the DEMO Toroidal Field (TF) superconducting magnets is designed to respond to a quench, which is a rapid transition from the superconducting state to normal conduction, or other faults. This system helps prevent severe damage to the TF magnets, which can experience significant thermal and voltage stresses during a quench, due to the intervention of the FDUs. These stresses can damage the insulation and compromise the magnet's integrity. FDUs play a crucial role in rapidly discharging the magnetic energy stored in the magnets. Silicon Carbide (SiC) varistors within the FDU, with their nonlinear behavior, can significantly reduce the voltage peak across the TF magnet at fast discharge with respect to normal resistors. In the high current configuration, the DEMO TF magnet system is composed of 16 TF coils, with: a total inductance of 22.56 H, an operating current of 105 kA and a total magnetic energy stored of about 124 GJ. Maximum voltage limits for TF coils are 6 kV terminal-to-terminal and 3 kV terminal-to-ground. Performance of technologies are compared considering voltage and hotspot temperature.
- Open Access
- 18 March 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (4) , 045605
Test results of the DTT poloidal field conductor samples in SULTAN: DC and AC characterization
The poloidal field (PF) magnet system of the Divertor Tokamak Test (DTT) facility consists of 6 superconducting coils with full top-down symmetry, realized in Nb3Sn (PF1 and PF6) and NbTi (PF2, PF3, PF4 and PF5). To validate the NbTi PF coil design, short samples of the cable-in-conduit-conductor cables (CICCs) have been qualified by dedicated cryogenic tests in the SULTAN facility at Swiss Plasma Centre (SPC, EPFL). In this work, we present the results of the two test campaigns conducted in August and September 2022, for the PF2/5 and PF3/4, respectively. The extensive characterization of the NbTi PF samples included a set of AC loss measurements using bipolar sinusoidal pulsing, as well as a set of DC tests spanning the range of the coils operability to assess the critical current, I c, and the current sharing temperature, T cs . The performances have been checked after electro-magnetic (EM) cyclic loading (up to 1000 cycles) at different B/I loads. The minimum quench energy (MQE) has also been measured at different temperatures. All tests confirmed the effectiveness of the PF CICCs design, showing good performance above the minimum acceptance values even at currents 110% higher than the nominal value.
- 18 March 2025
- Published by IOP Publishing in Physica Scripta
- Vol. 100 (4) , 045605
Open AccessTest results of the DTT poloidal field conductor samples in SULTAN: DC and AC characterization
The poloidal field (PF) magnet system of the Divertor Tokamak Test (DTT) facility consists of 6 superconducting coils with full top-down symmetry, realized in Nb3Sn (PF1 and PF6) and NbTi (PF2, PF3, PF4 and PF5). To validate the NbTi PF coil design, short samples of the cable-in-conduit-conductor cables (CICCs) have been qualified by dedicated cryogenic tests in the SULTAN facility at Swiss Plasma Centre (SPC, EPFL). In this work, we present the results of the two test campaigns conducted in August and September 2022, for the PF2/5 and PF3/4, respectively. The extensive characterization of the NbTi PF samples included a set of AC loss measurements using bipolar sinusoidal pulsing, as well as a set of DC tests spanning the range of the coils operability to assess the critical current, I c, and the current sharing temperature, T cs . The performances have been checked after electro-magnetic (EM) cyclic loading (up to 1000 cycles) at different B/I loads. The minimum quench energy (MQE) has also been measured at different temperatures. All tests confirmed the effectiveness of the PF CICCs design, showing good performance above the minimum acceptance values even at currents 110% higher than the nominal value.
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Characterization of the Full-Size Superconducting ASG Joint Designed for the DTT Toroidal Field Coils
The Divertor Tokamak Test (DTT) facility is a challenging high-field and compact tokamak, currently under construction at the Frascati ENEA Research Center. Its purpose is to significantly contribute to the exploration, design and assessment of systems intended for the management of heat exhaust. Its superconducting magnetic system consists of 18 Toroidal Field (TF) coils, 6 Poloidal Field (PF) coils and a Central Solenoid (CS). This work is focused on the superconducting praying-hands joint, manufactured by ASG-Superconductors for the DTT TF coils terminations and for the connection among the adjacent double-pancakes constituting the TF winding pack. The joint has been tested and fully characterized by dedicated 2-weeks cryogenic tests in the SULTAN facility at Swiss Plasma Centre (SPC, EPFL) in November 2023. The tests included 3000 EM cycles at the maximum foreseen operative load of 8.1 T–21 kA and two Warm-Up-Cool-Down (WUCD) cycles, while reference DC measurements were done in normal and reversed polarity up to 42.5 kA and to 4 T, before, during and after cyclic loading and WUCDs. Assessment of AC losses, performed through bipolar sinusoidal pulsing at frequencies up to 2 Hz, and pressure drop measurements as a function of He mass flow rate, were conducted on the virgin sample and after full cyclic loading. The Minimum Quench Energy (MQE) has also been measured at different temperatures under nominal current conditions. All the conducted tests confirmed the efficacy and goodness of the joint design, with its resistance at self-field consistently remaining below the nominal allowable value of 2 nΩ.
- 17 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 35 (5) , 1-5
Characterization of the Full-Size Superconducting ASG Joint Designed for the DTT Toroidal Field Coils
The Divertor Tokamak Test (DTT) facility is a challenging high-field and compact tokamak, currently under construction at the Frascati ENEA Research Center. Its purpose is to significantly contribute to the exploration, design and assessment of systems intended for the management of heat exhaust. Its superconducting magnetic system consists of 18 Toroidal Field (TF) coils, 6 Poloidal Field (PF) coils and a Central Solenoid (CS). This work is focused on the superconducting praying-hands joint, manufactured by ASG-Superconductors for the DTT TF coils terminations and for the connection among the adjacent double-pancakes constituting the TF winding pack. The joint has been tested and fully characterized by dedicated 2-weeks cryogenic tests in the SULTAN facility at Swiss Plasma Centre (SPC, EPFL) in November 2023. The tests included 3000 EM cycles at the maximum foreseen operative load of 8.1 T–21 kA and two Warm-Up-Cool-Down (WUCD) cycles, while reference DC measurements were done in normal and reversed polarity up to 42.5 kA and to 4 T, before, during and after cyclic loading and WUCDs. Assessment of AC losses, performed through bipolar sinusoidal pulsing at frequencies up to 2 Hz, and pressure drop measurements as a function of He mass flow rate, were conducted on the virgin sample and after full cyclic loading. The Minimum Quench Energy (MQE) has also been measured at different temperatures under nominal current conditions. All the conducted tests confirmed the efficacy and goodness of the joint design, with its resistance at self-field consistently remaining below the nominal allowable value of 2 nΩ.
- Open Access
- 19 May 2024
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 37 (7) , 075009
DTT toroidal field conductor samples test in Sultan: DC and AC characterization
The superconducting magnet system of the Divertor Tokamak Test (DTT) facility, composed of 18 toroidal field (TF) coils, 6 poloidal field coils and a central solenoid, has been designed and many procurements have been launched. Some manufacturing aspects and some conductor features require characterization under relevant close-to-operative conditions. To confirm the design choices in all details, cryogenic tests in qualified facilities have been foreseen. In this work, the results of the TF samples characterization at the SULTAN facility at the Swiss Plasma Centre (SPC, EPFL) are presented. The 3 week test campaign started on July the 8th, 2022. The DTT TF SULTAN sample was made of two Nb3Sn cable-in-conduit conductor ‘legs’, namely ‘TF-A’ and ‘TF-B’, made with wires produced by Kiswire Advanced Technology, differing for the cabling twist pitch sequence only, and designed to work in DTT at 42.5 kA at 11.9 T peak field. The extensive characterization comprised 3000 electro-magnetic (EM) cycles and two warm-up-cool-down (WUCD) steps, and in detail it included: AC measurements on the virgin conductors, on cyclic loaded conductors and after WUCDs; DC tests at 10.85 T/42.5 kA with intermediate EM cycles at 10.85 T/45 kA before and after WUCDs; DC tests using partial Lorentz force loads, and Minimum Quench Energy tests at 9 T/42.5 kA after cycles and WUCDs. The results of the DC measurement analysis verified the design, in terms of current sharing temperature (T cs) and critical current (I c), as both samples are over the minimum acceptance values. In particular, the ‘TF-A’ sample, characterized by a so-called ‘long twist pitch’ cabling sequence, showed higher performance without any degradation with loading and WUCD cycles, whereas sample ‘TF-B’ presented an initial T cs reduction that afterwards substantially remained unchanged. In terms of strain acting at the Nb3Sn filaments level, this result can be described by a lower effective strain in the ‘TF-A’ sample. AC losses were measured with a calorimetric method as a function of frequency for each series of AC sinusoidal pulsing measurements, and the characteristic coupling time constants were determined.
- 19 May 2024
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 37 (7) , 075009
Open AccessDTT toroidal field conductor samples test in Sultan: DC and AC characterization
The superconducting magnet system of the Divertor Tokamak Test (DTT) facility, composed of 18 toroidal field (TF) coils, 6 poloidal field coils and a central solenoid, has been designed and many procurements have been launched. Some manufacturing aspects and some conductor features require characterization under relevant close-to-operative conditions. To confirm the design choices in all details, cryogenic tests in qualified facilities have been foreseen. In this work, the results of the TF samples characterization at the SULTAN facility at the Swiss Plasma Centre (SPC, EPFL) are presented. The 3 week test campaign started on July the 8th, 2022. The DTT TF SULTAN sample was made of two Nb3Sn cable-in-conduit conductor ‘legs’, namely ‘TF-A’ and ‘TF-B’, made with wires produced by Kiswire Advanced Technology, differing for the cabling twist pitch sequence only, and designed to work in DTT at 42.5 kA at 11.9 T peak field. The extensive characterization comprised 3000 electro-magnetic (EM) cycles and two warm-up-cool-down (WUCD) steps, and in detail it included: AC measurements on the virgin conductors, on cyclic loaded conductors and after WUCDs; DC tests at 10.85 T/42.5 kA with intermediate EM cycles at 10.85 T/45 kA before and after WUCDs; DC tests using partial Lorentz force loads, and Minimum Quench Energy tests at 9 T/42.5 kA after cycles and WUCDs. The results of the DC measurement analysis verified the design, in terms of current sharing temperature (T cs) and critical current (I c), as both samples are over the minimum acceptance values. In particular, the ‘TF-A’ sample, characterized by a so-called ‘long twist pitch’ cabling sequence, showed higher performance without any degradation with loading and WUCD cycles, whereas sample ‘TF-B’ presented an initial T cs reduction that afterwards substantially remained unchanged. In terms of strain acting at the Nb3Sn filaments level, this result can be described by a lower effective strain in the ‘TF-A’ sample. AC losses were measured with a calorimetric method as a function of frequency for each series of AC sinusoidal pulsing measurements, and the characteristic coupling time constants were determined.
- 5 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Electromechanical Characterization of Advanced Internal-Tin Nb3Sn Strands for the DTT Magnet System
This paper presents a practical parameterization of the critical surface of the 0.82-mm diameter Nb 3 Sn strands used for the Toroidal Field coils of the Italian Divertor Tokamak Test Facility. The critical current has been measured by means of a Walters Spring device as a function of uniaxial applied strain (±0.5% intrinsic strain) at different field (up to 14 T) and in the temperature range comprised between 4.5 K and 10 K. The experimental results have been analyzed in the framework of the ITER-2008 parameterization and the Extrapolative Scaling Expression, by using a multi-step approach for the data fitting. The accuracy of the scaling laws provides an accurate parameterization of the critical surface in terms of field, temperature and strain, to be used for the characterization and production follow-up of the DTT qualification samples and coils.
- 5 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Electromechanical Characterization of Advanced Internal-Tin Nb3Sn Strands for the DTT Magnet System
This paper presents a practical parameterization of the critical surface of the 0.82-mm diameter Nb 3 Sn strands used for the Toroidal Field coils of the Italian Divertor Tokamak Test Facility. The critical current has been measured by means of a Walters Spring device as a function of uniaxial applied strain (±0.5% intrinsic strain) at different field (up to 14 T) and in the temperature range comprised between 4.5 K and 10 K. The experimental results have been analyzed in the framework of the ITER-2008 parameterization and the Extrapolative Scaling Expression, by using a multi-step approach for the data fitting. The accuracy of the scaling laws provides an accurate parameterization of the critical surface in terms of field, temperature and strain, to be used for the characterization and production follow-up of the DTT qualification samples and coils.
- 15 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
DC Characterization of a Low-Field Nb3Sn Prototype Conductor for a DEMO TF Coil
A Low Field W&R (Wind and React) conductor, developed in the frame of the conceptual design studies for the Toroidal Field (TF) coils of DEMO, has been designed to be constituted of a small number of superconducting Nb 3 Sn strands and a high number of stabilization copper wires. It has been extensively characterized at the SULTAN facility at Swiss Plasma Center (SPC) in February 2021. The conductor has been operated up to its target current, 70.8 kA, and characterized up to a background magnetic field of 10.78 T. The test program included AC loss measurements, current sharing temperature ( Tcs ) and critical current ( Ic ) measurements before and after cyclic loading. Critical temperature ( Tc ) measurements were performed on the virgin conductor at the beginning and at the end of the test campaign. In this work we are focusing on the DC characterization, while the AC measurements analysis will be the object of a following work. Concerning DC tests, premature quench phenomena prevented from operating the conductor at the target current – field conditions. Nevertheless, at lower currents Tcs stability was observed, with no performance degradation due to cycling. The present paper investigates these results and tries to give an explanation through measurements and tomographic analysis. Furthermore, the achieved strain distribution in the conductor, obtained by means of inductive measurements analysis, will be shown. The implications of the design approach on the performance, based on the outcome of such tests, are discussed.
- 15 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
DC Characterization of a Low-Field Nb3Sn Prototype Conductor for a DEMO TF Coil
A Low Field W&R (Wind and React) conductor, developed in the frame of the conceptual design studies for the Toroidal Field (TF) coils of DEMO, has been designed to be constituted of a small number of superconducting Nb 3 Sn strands and a high number of stabilization copper wires. It has been extensively characterized at the SULTAN facility at Swiss Plasma Center (SPC) in February 2021. The conductor has been operated up to its target current, 70.8 kA, and characterized up to a background magnetic field of 10.78 T. The test program included AC loss measurements, current sharing temperature ( Tcs ) and critical current ( Ic ) measurements before and after cyclic loading. Critical temperature ( Tc ) measurements were performed on the virgin conductor at the beginning and at the end of the test campaign. In this work we are focusing on the DC characterization, while the AC measurements analysis will be the object of a following work. Concerning DC tests, premature quench phenomena prevented from operating the conductor at the target current – field conditions. Nevertheless, at lower currents Tcs stability was observed, with no performance degradation due to cycling. The present paper investigates these results and tries to give an explanation through measurements and tomographic analysis. Furthermore, the achieved strain distribution in the conductor, obtained by means of inductive measurements analysis, will be shown. The implications of the design approach on the performance, based on the outcome of such tests, are discussed.
- 1 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Primary Quench Detection Analysis for DTT Central Solenoid and Poloidal Field Coils
The Central Solenoid (CS) and the Poloidal Field (PF) coils of the DTT tokamak (Divertor Tokamak Test facility, currently being built in the site of ENEA C.R. Frascati – Italy) are operated in dynamic mode and, even in normal operation, the self and mutual voltages induced across each coil are of the order of magnitude of ≈100 V. In DTT, these coils will be realized with superconducting materials and, as a consequence, a reliable and fast quench detection system is required in order to protect the magnets. Being the quench signals 4 orders of magnitude smaller than the operating voltages, the cowound (CW) technology must be adopted for the quench sensors, the only degree of freedom being among a wiring configuration merely aligned with the coil winding (CWA) or aligned and twisted to the coil winding (CWA&TW). In this study, a model of the DTT poloidal magnetic system has been developed up to the details of the single windings (layer or pancake) of the various coils. CWA sensors have also been implemented in the model. Signals coming from the magnetic system and the CWA sensors during the Single Null plasma event have been simulated and compared. The analysis has been carried out up to the level of the elementary winding of each coil, using a lumped parameters circuital model. Finally, a simple theory has been developed aimed at the estimations of the improvements coming from the CWA&TW architecture.
- 1 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-4
Primary Quench Detection Analysis for DTT Central Solenoid and Poloidal Field Coils
The Central Solenoid (CS) and the Poloidal Field (PF) coils of the DTT tokamak (Divertor Tokamak Test facility, currently being built in the site of ENEA C.R. Frascati – Italy) are operated in dynamic mode and, even in normal operation, the self and mutual voltages induced across each coil are of the order of magnitude of ≈100 V. In DTT, these coils will be realized with superconducting materials and, as a consequence, a reliable and fast quench detection system is required in order to protect the magnets. Being the quench signals 4 orders of magnitude smaller than the operating voltages, the cowound (CW) technology must be adopted for the quench sensors, the only degree of freedom being among a wiring configuration merely aligned with the coil winding (CWA) or aligned and twisted to the coil winding (CWA&TW). In this study, a model of the DTT poloidal magnetic system has been developed up to the details of the single windings (layer or pancake) of the various coils. CWA sensors have also been implemented in the model. Signals coming from the magnetic system and the CWA sensors during the Single Null plasma event have been simulated and compared. The analysis has been carried out up to the level of the elementary winding of each coil, using a lumped parameters circuital model. Finally, a simple theory has been developed aimed at the estimations of the improvements coming from the CWA&TW architecture.
- 24 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
DTT: A Challenging Framework for a Sound Superconducting Magnets Design
At the ENEA's research center of Frascati, the DTT (Divertor Tokamak Test) facility is currently under construction. The activity of this experimental nuclear fusion reactor, will be focused on the optimization of the power exhaust management in view of DEMO. The project has been started during year 2015, when also the superconducting magnet system has been initially designed, basing on the available inputs coming from physics and on the desired goals for the machine. At present, the coils engineering design has almost been completed and the production of crucial components, such as the superconducting strands, conductors and toroidal field coils, have already been started. For the remaining superconducting elements, the engineering design is being finalized and other tenders are going to be launched soon. The result is a compact and flexible tokamak, with highly demanding requirements in terms of superconducting and structural performances, sometime close to the intrinsic mechanical limits of the adopted materials. Tight constraints on time, budget and resources forced the design team to walk through a complex path in these years for reaching a sound and satisfactory design of the complete magnet system. In fact, it was not possible to rely entirely on state-of-the-art and already assessed superconducting technologies, as was initially assumed. In particular, the trade-off between limiting the R&D phase and extending the performance demonstrated in other projects to the specific DTT requirements, pushed the team to take some risks, while providing a robust and fully performing magnet system design.
- 24 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
DTT: A Challenging Framework for a Sound Superconducting Magnets Design
At the ENEA's research center of Frascati, the DTT (Divertor Tokamak Test) facility is currently under construction. The activity of this experimental nuclear fusion reactor, will be focused on the optimization of the power exhaust management in view of DEMO. The project has been started during year 2015, when also the superconducting magnet system has been initially designed, basing on the available inputs coming from physics and on the desired goals for the machine. At present, the coils engineering design has almost been completed and the production of crucial components, such as the superconducting strands, conductors and toroidal field coils, have already been started. For the remaining superconducting elements, the engineering design is being finalized and other tenders are going to be launched soon. The result is a compact and flexible tokamak, with highly demanding requirements in terms of superconducting and structural performances, sometime close to the intrinsic mechanical limits of the adopted materials. Tight constraints on time, budget and resources forced the design team to walk through a complex path in these years for reaching a sound and satisfactory design of the complete magnet system. In fact, it was not possible to rely entirely on state-of-the-art and already assessed superconducting technologies, as was initially assumed. In particular, the trade-off between limiting the R&D phase and extending the performance demonstrated in other projects to the specific DTT requirements, pushed the team to take some risks, while providing a robust and fully performing magnet system design.
- 29 November 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 35 (1) , 014002
A methodological approach for the optimal design of the toroidal field coils of a tokamak device using artificial intelligence
As prototypes of future commercial tokamaks, DEMOs nuclear fusion power plants are expected to be able to produce cost-effective electrical power. In this view, an optimized design becomes crucial in the whole engineering workflow. Up to now, the design of one of the most critical components, the cross-section of each of the toroidal field coils inner leg winding pack, was performed using a sequential trial-and-error procedure. In this work, a novel comprehensive approach is proposed to include all the main design aspects into a unified tool taking advantage of artificial neural networks for faster computation in finding optimal design configurations. This procedure overcomes several difficulties including dealing with both real-valued and discrete design variables, the significant CPU-time of magneto-structural analysis and also guarantees the optimality for the winding pack configuration. The proposed methodology was demonstrated for the 2019 ENEA DEMO configuration which includes 16 toroidal field coils, made-up of 6 Nb3Sn double layers and a Wind and React manufacturing technique.
- 29 November 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 35 (1) , 014002
A methodological approach for the optimal design of the toroidal field coils of a tokamak device using artificial intelligence
As prototypes of future commercial tokamaks, DEMOs nuclear fusion power plants are expected to be able to produce cost-effective electrical power. In this view, an optimized design becomes crucial in the whole engineering workflow. Up to now, the design of one of the most critical components, the cross-section of each of the toroidal field coils inner leg winding pack, was performed using a sequential trial-and-error procedure. In this work, a novel comprehensive approach is proposed to include all the main design aspects into a unified tool taking advantage of artificial neural networks for faster computation in finding optimal design configurations. This procedure overcomes several difficulties including dealing with both real-valued and discrete design variables, the significant CPU-time of magneto-structural analysis and also guarantees the optimality for the winding pack configuration. The proposed methodology was demonstrated for the 2019 ENEA DEMO configuration which includes 16 toroidal field coils, made-up of 6 Nb3Sn double layers and a Wind and React manufacturing technique.