Alfredo Holgueras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alfredo Holgueras has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Alberto López-Miguel
Universidad de Valladolid
3 shared publications - Miguel J. Maldonado
Instituto de Oftalmobiología Aplicada (IOBA), Universidad de Valladolid, Valladolid, Spain
3 shared publications - Itziar Fernández
Institute of Applied Ophthalmobiology (IOBA), University of Valladolid, Valladolid, Spain
2 shared publications María Sanchidrián
IOBA, Institute of Applied Ophthalmobiology, Universidad de Valladolid, Paseo Belén, 17, 47011, Valladolid, Spain
2 shared publications- Alberto López-De la Rosa
Department of Theoretical Physics, Atomic and Optics University of Valladolid Valladolid Spain
1 shared publication - Elena Martínez-Plaza
Department of Optics, Pharmacology and Anatomy, University of Alicante, 03690 Alicante, Spain
1 shared publication
Latest Publications
- 1 February 2023
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 20 (2) , 75-83
EVO/EVO+ Visian Implantable Collamer Lenses for the correction of myopia and myopia with astigmatism
Intraocular lens implantation in phakic eyes for the correction of refractive error is currently a widespread procedure. The EVO and EVO+ Visian Implantable Collamer Lenses (ICL) are two of the mos...
- 1 February 2023
- Published by Taylor & Francis in Expert Review of Medical Devices
- Vol. 20 (2) , 75-83
EVO/EVO+ Visian Implantable Collamer Lenses for the correction of myopia and myopia with astigmatism
Intraocular lens implantation in phakic eyes for the correction of refractive error is currently a widespread procedure. The EVO and EVO+ Visian Implantable Collamer Lenses (ICL) are two of the mos...
- 11 February 2017
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 255 (4) , 839-840
Letter to the editor. “Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery”
- 11 February 2017
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 255 (4) , 839-840
Letter to the editor. “Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery”
- 22 November 2016
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 255 (2) , 387-392
Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
To compare specular microscopy (Topcon SP-3000P, Topcon Corporation, Tokyo, Japan) and ultrasound (US) technology when evaluating central corneal thickness (CCT) prior to and after phacoemulsification. Corneal edema was assessed in phacoemulsification patients due to senile cataract by measuring CCT preoperatively and 1 day, 1 month, and 3 months postoperatively. Bland–Altman analysis was performed to assess interchangeability between pachymetry techniques for each visit. Repeated measures analysis of variance was performed to evaluate variation in CCT agreement depending on the degree of corneal edema. One hundred and eighteen patients aged 73.9 ± 10.1 years were recruited. Topcon SP-3000P provided significant (p < 0.0001) lower CCT values than US with and without induced corneal edema. Mean differences between CCT techniques for baseline, 1 day, 1 month and 3 months after cataract surgery were −28.9 ± 22.6, −30.5 ± 41.4, −32.3 ± 16.2 and −33.0 ± 16.9 μm, respectively. The systematic bias observed was not significantly different among the 4 visits (p = 0.59). The estimated limits of agreement (based on 1.96 standard deviation) were substantial, being 90.5, 165.8, 64.9 and 67.5 um at baseline, 1 day and 1 and 3 months. Topcon SP-3000P provides similar systematic bias in comparison with US technique for CCT measurements regardless of the degree of corneal edema after phacoemulsification, which should be reduced after applying a constant calibration adjustment of ∼30 μm. However, interchangeability between techniques may be still limited by the notable random measurement error.
- 22 November 2016
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 255 (2) , 387-392
Comparison of specular microscopy and ultrasound pachymetry before and after cataract surgery
To compare specular microscopy (Topcon SP-3000P, Topcon Corporation, Tokyo, Japan) and ultrasound (US) technology when evaluating central corneal thickness (CCT) prior to and after phacoemulsification. Corneal edema was assessed in phacoemulsification patients due to senile cataract by measuring CCT preoperatively and 1 day, 1 month, and 3 months postoperatively. Bland–Altman analysis was performed to assess interchangeability between pachymetry techniques for each visit. Repeated measures analysis of variance was performed to evaluate variation in CCT agreement depending on the degree of corneal edema. One hundred and eighteen patients aged 73.9 ± 10.1 years were recruited. Topcon SP-3000P provided significant (p < 0.0001) lower CCT values than US with and without induced corneal edema. Mean differences between CCT techniques for baseline, 1 day, 1 month and 3 months after cataract surgery were −28.9 ± 22.6, −30.5 ± 41.4, −32.3 ± 16.2 and −33.0 ± 16.9 μm, respectively. The systematic bias observed was not significantly different among the 4 visits (p = 0.59). The estimated limits of agreement (based on 1.96 standard deviation) were substantial, being 90.5, 165.8, 64.9 and 67.5 um at baseline, 1 day and 1 and 3 months. Topcon SP-3000P provides similar systematic bias in comparison with US technique for CCT measurements regardless of the degree of corneal edema after phacoemulsification, which should be reduced after applying a constant calibration adjustment of ∼30 μm. However, interchangeability between techniques may be still limited by the notable random measurement error.