RKRanish Deedar Ali Khawaja

Ranish Deedar Ali Khawaja

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ranish Deedar Ali Khawaja has a total of 40 co-authors. Here are the top co-authors by number of shared publications:

  • Sarabjeet Singh

    MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA

    7 shared publications
  • Atul Padole

    Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA

    4 shared publications
  • Mannudeep K. Kalra

    MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA

    4 shared publications
  • Atul Padole

    MGH Imaging, Massachusetts General Hospital and Harvard Medical School, Boston, MA, USA

    3 shared publications
  • Mannudeep K. Kalra

    Department of Radiology, Massachusetts General Hospital, Boston, MA 02114, USA

    3 shared publications
  • Sarvenaz Pourjabbar

    From the Department of Diagnostic Radiology and Biomedical Imaging, Yale University School of Medicine, 333 Cedar St, PO Box 208042, Room TE-2, New Haven, CT 06520 (M.V.R., A.I., S.P., A.M., N.N., M.S.); Department of Radiology, Mayo Clinic Arizona, Phoenix, Ariz (C.M.); and Department of Radiology, Zucker School of Medicine at Hofstra/Northwell, Northwell Health System, Manhasset, NY (J.S.P.).

    3 shared publications

Latest Publications

  • Corrigendum to “Ultra-low dose abdominal MDCT: Using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study” [Eur. J. Radiol. 84 (2015) 2–10]

    by Ranish Deedar Ali Khawaja, Sarabjeet Singh, Michael Blake, Mukesh Harisinghani, Garry Choy, Ali Karaosmanoglu, Atul Padole, Synho Do, Kevin Brown, Richard Thompson, et al.

  • Dose reduction for chest CT: comparison of two iterative reconstruction techniques

    by Sarvenaz Pourjabbar, Sarabjeet Singh, Naveen Kulkarni, Victorine Muse, Subba R Digumarthy, Ranish Deedar Ali Khawaja, Atul Padole, Synho Do, Mannudeep K Kalra

    Background: Lowering radiation dose in computed tomography (CT) scan results in low quality noisy images. Iterative reconstruction techniques are used currently to lower image noise and improve the quality of images. Purpose: To evaluate lesion detection and diagnostic acceptability of chest CT images acquired at CTDIvol of 1.8 mGy and processed with two different iterative reconstruction techniques. Material and Methods: Twenty-two patients (mean age, 60 ± 14 years; men, 13; women, 9; body mass index, 27.4 ± 6.5 kg/m2) gave informed consent for acquisition of low dose (LD) series in addition to the standard dose (SD) chest CT on a 128 - multidetector CT (MDCT). LD images were reconstructed with SafeCT C4, L1, and L2 settings, and Safire S1, S2, and S3 settings. Three thoracic radiologists assessed LD image series (S1, S2, S3, C4, L1, and L2) for lesion detection and comparison of lesion margin, visibility of normal structures, and diagnostic confidence with SD chest CT. Inter-observer agreement (kappa) was calculated. Results: Average CTDIvol was 6.4 ± 2.7 mGy and 1.8 ± 0.2 mGy for SD and LD series, respectively. No additional lesion was found in SD as compared to LD images. Visibility of ground-glass opacities and lesion margins, as well as normal structures visibility were not affected on LD. CT image visibility of major fissure and pericardium was not optimal in some cases ( n = 5). Objective image noise in some low dose images processed with SafeCT and Safire was similar to SD images ( P value > 0.5). Conclusion: Routine LD chest CT reconstructed with iterative reconstruction technique can provide similar diagnostic information in terms of lesion detection, margin, and diagnostic confidence as compared to SD, regardless of the iterative reconstruction settings.


  • Assessment of Filtered Back Projection, Adaptive Statistical, and Model-Based Iterative Reconstruction for Reduced Dose Abdominal Computed Tomography

    by Atul Padole, Sarabjeet Singh, Diego Lira, Michael A. Blake, Sarvenaz Pourjabbar, Ranish Deedar Ali Khawaja, Garry Choy, Sanjay Saini, Synho Do, Mannudeep K. Kalra

    To compare standard of care and reduced dose (RD) abdominal computed tomography (CT) images reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), model-based iterative reconstruction (MBIR) techniques. In an Institutional Review Board-approved, prospective clinical study, 28 patients (mean age 59 ± 13 years ), undergoing clinically indicated routine abdominal CT on a 64-channel multi-detector CT scanner, gave written informed consent for acquisition of an additional RD (<1 milli-Sievert) abdomen CT series. Sinogram data of RD series were reconstructed with FBP, ASIR, and MBIR and compared with FBP images of standard dose abdomen CT. Two radiologists performed randomized, independent, and blinded comparison for lesion detection, lesion margin, visibility of normal structures, and diagnostic confidence. Mean CT dose index volume was 10 ± 3.4 mGy and 1.3 ± 0.3 mGy for standard and RD CT, respectively. There were 73 "true positive" lesions detected on standard of care CT. Nine lesions (<8 mm in size) were missed on RD abdominal CT images which included liver lesions, liver cysts, kidney cysts, and paracolonic abscess. These lesions were missed regardless of patient size and types of iterative reconstruction techniques used for reconstruction of RD data sets. The visibility of lesion margin was suboptimal in (23/28) patients with RD FBP, (15/28) patients with RD ASIR, and (14/28) patients with RD MBIR compared to standard of care FBP images (P < 0.001). Diagnostic confidence for the assessment of lesions on RD images was suboptimal in most patients regardless of iterative reconstruction techniques. Clinically significant lesions (< 8 mm) can be missed on abdominal CT examinations acquired at a CT dose index volume of 1.3 mGy regardless of patients' size and reconstruction techniques (FBP, ASIR, and MBIR).


  • Ultra-low dose abdominal MDCT: Using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study

    by Ranish Deedar Ali Khawaja, Sarabjeet Singh, Michael Blake, Mukesh Harisinghani, Garry Choy, Ali Karosmangulu, Atul Padole, Synho Do, Kevin Brown, Richard Thompson, et al.


  • Dose reduction in pediatric abdominal CT: use of iterative reconstruction techniques across different CT platforms

    by Ranish Deedar Ali Khawaja, Sarabjeet Singh, Alexi Otrakji, Atul Padole, Ruth Lim, Katherine Nimkin, Sjirk Westra, Mannudeep K. Kalra, Michael S. Gee

    Dose reduction in children undergoing CT scanning is an important priority for the radiology community and public at large. Drawbacks of radiation reduction are increased image noise and artifacts, which can affect image interpretation. Iterative reconstruction techniques have been developed to reduce noise and artifacts from reduced-dose CT examinations, although reconstruction algorithm, magnitude of dose reduction and effects on image quality vary. We review the reconstruction principles, radiation dose potential and effects on image quality of several iterative reconstruction techniques commonly used in clinical settings, including 3-D adaptive iterative dose reduction (AIDR-3D), adaptive statistical iterative reconstruction (ASIR), iDose, sinogram-affirmed iterative reconstruction (SAFIRE) and model-based iterative reconstruction (MBIR). We also discuss clinical applications of iterative reconstruction techniques in pediatric abdominal CT.


  • Ultra low-dose chest CT using filtered back projection: Comparison of 80-, 100- and 120kVp protocols in a prospective randomized study

    by Ranish Deedar Ali Khawaja, Sarabjeet Singh, Rachna Madan, Amita Sharma, Atul Padole, Sarvenaz Pourjabbar, Subba Digumarthy, Jo-Anne Shepard, Mannudeep K. Kalra


  • Role of Compressive Sensing Technique in Dose Reduction for Chest Computed Tomography

    by Ranish Deedar Ali Khawaja, Sarabjeet Singh, Diego Lira, Rolf Bippus, Synho Do, Atul Padole, Sarvenaz Pourjabbar, Thomas Koehler, Jo-Anne Shepard, Mannudeep K. Kalra

    Purpose: The purpose of this study was to assess pulmonary lesion detection, diagnostic confidence, and noise reduction in sparse-sampled (SpS) computed tomographic (CT) data of submillisievert (SubmSv) chest CT reconstructed with iterative reconstruction technique (IRT). Materials and Methods: This Human Insurance Portability and Accountability-compliant, institutional review board-approved prospective study was performed using SpS-SubmSv IRT chest CT in 10 non-obese patients (body-mass index, 21-35 kg/m(2); age range, 26-90 years). Written informed consent was obtained. The patients were scanned at standard-dose CT (mean [SD] volumetric CT dose index, 6 [0.9] mGy; mean [SD] dose-length product, 208 +/- 44 mGy . cm; and mean [SD] effective dose, 3 [0.6] mSv) and at SubmSv dose (1.8 [0.2] mGy, 67 [2] mGy . cm, 0.9 [0.03] mSv, respectively) on a Philips 128-slice CT scanner with double z-sampling. Sparse angular sampling data were reconstructed using 25% of the angular projections from the SubmSv sinogram to reduce the number of views and radiation dose by approximately 4-fold. Hence, the patients were scanned and then, simulation-based sparse sampling was performed with a resultant dose hypothetical SpS scan estimated mathematically (0.2 mSv). From each patient data, 3 digital imaging and communications in medicine series were generated: SpS-SubmSv with IRT, fully sampled SubmSv filtered back projection (FBP), and fully sampled standard-dose FBP (SD-FBP). Two radiologists independently assessed these image series for detection of lung lesions, visibility of small structures, and diagnostic acceptability. Objective noise was measured in the thoracic aorta, and noise spectral density was obtained for SpS-SubmSv IRT, SubmSv-FBP, and SD-FBP. Results: The SpS-SubmSv IRT resulted in 75% (0.2/0.9 mSv) and 92% (0.2/2.9 mSv) dose reduction, when compared with the fully sampled SubmSv-FBP and SD-FBP, respectively. Images of SpS-SubmSv displayed all 46 lesions (most < 1 cm, 30 lung nodules, 7 ground glass opacities, 9 emphysema) seen on the SubmSv-FBP and SD-FBP data sets. Lesion margins with sparse-sampled data were deemed acceptable compared with both SubmSv-FBP and SD-FBP. Overall diagnostic confidence was maintained with SpS-SubmSv IRT despite the presence of minor pixilation artifacts in 3 of 10 cases. The SpS-SubmSv IRT showed 63% and 38% noise reduction when compared with SubmSv-FBP (P < 0.0001) and SD-FBP (P < 0.01), respectively, with no significant change in Hounsfield unit values (P > 0.05). Noise-spectral density showed that SpS-SubmSv IRT gives a linear decrease over frequency in the semilog plot and an exponential decrease of noise power over frequency compared with SubmSv-FBP and SD-FBP. Conclusions: More than 90% dose reduction could be achieved with one-fourth sparse-sampled and SubmSv chest CT examination when reconstructed with IRT. Chest CT dose at one fourth of a millisievert with SpS is possible with optimal lesion detection and diagnostic confidence for the evaluation of pulmonary findings.