SWStefan Weyers

Stefan Weyers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stefan Weyers has a total of 147 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Challenges in time and frequency metrology: accomplishments and overview of ongoing work

    by N Dimarcq, P Tavella, S Bize, D Calonico, P Defraigne, E A Donley, F Fang, M Fujieda, M Gertsvolf, Y Hanado, et al.

    This paper is an introduction to the Metrologia Focus on the Challenges in Time and Frequency (TF) Metrology. It presents the main consultative committee for time and frequency (CCTF) activities in different fields of TF metrology: primary and SFS, TF transfer techniques, and atomic time scales. This includes cross-cutting ‘hot topics’ that deserve special attention such as: redefinition of the international system of units second, continuous UTC and leap seconds, mutual benefits between UTC and global navigation satellite system. The CCTF aims to ensure the best services to the TF community, including focused training based on resource sharing to improve national and international timekeeping.

  • Open Access

    Transportable strontium lattice clock with 4 × 10 − 19 blackbody radiation shift uncertainty

    by I Nosske, C Vishwakarma, T Lücke, J Rahm, N Poudel, S Weyers, E Benkler, S Dörscher, C Lisdat

    We describe a transportable optical lattice clock based on the 1 S 0 → 3 P 0 transition of lattice-trapped 87 Sr atoms with a total systematic uncertainty of 2.1 × 10 − 18 . The blackbody radiation shift, which is the leading systematic effect in many strontium lattice clocks, is controlled at the level of 4.0 × 10 − 19 , as the atoms are interrogated inside a well-characterised, cold thermal shield. Using a transportable clock laser, the clock reaches a frequency instability of about 5 × 10 − 16 / τ / s , which enables fast reevaluations of systematic effects. By comparing this clock to the primary caesium fountain clocks CSF1 and CSF2 at Physikalisch-Technische Bundesanstalt, we measure the clock transition frequency with a fractional uncertainty of 1.9 × 10 − 16 , in agreement with previous results. The clock was successfully transported and operated at different locations. It holds the potential to be used for geodetic measurements with centimetre-level or better height resolution and for accurate inter-institute frequency comparisons.


  • Top Cited Papers
    Open Access

    88 Sr + optical clock with 7.9 × 10 − 19 systematic uncertainty and measurement of its absolute frequency with 9.8 × 10 − 17 uncertainty

    by T. Lindvall, T. Fordell, K.J. Hanhijärvi, M. Doležal, J. Rahm, S. Weyers, A.E. Wallin

    We report on a 88 Sr + single-ion optical clock with an estimated fractional systematic uncertainty of 7.9× 10 − 19 . The low uncertainty is enabled by small rf losses, a thorough evaluation of the blackbody-radiation temperature, and our recent measurement of the differential polarizability. A detailed uncertainty evaluation is presented. We also report on two absolute frequency measurements: one against a remote cesium fountain clock, and one against International Atomic Time (TAI). The former lasted 12 d and resulted in a frequency value of 444 779 044 095 485.49(15) Hz. The latter spanned 10 months with monthly optical-clock uptimes between 68% and 99%, and yielded a frequency value of 444 779 044 095 485.373(44) Hz. With a fractional uncertainty of 9.8× 10 − 17 , it is, to our knowledge, the most accurate optical frequency measurement reported to date. Both frequency values are in agreement with other recent measurements, providing further evidence that the 2021 CIPM recommended frequency value is too high by 1.6 times its uncertainty.


  • Top Cited Papers
    Open Access

    In+115−Yb+172 Coulomb Crystal Clock with 2.5×10−18 Systematic Uncertainty

    by H. N. Hausser, J. Keller, T. Nordmann, N. M. Bhatt, J. Kiethe, H. Liu, I. M. Richter, M. von Boehn, J. Rahm, S. Weyers, et al.

    We present a scalable mixed-species Coulomb crystal clock based on the S 0 1 ↔ P 3 0 transition in In + 115 . Yb + 172 ions are cotrapped and used for sympathetic cooling. Reproducible interrogation conditions for mixed-species Coulomb crystals are ensured by a conditional preparation sequence with permutation control. We demonstrate clock operation with a 1 In + − 3 Yb + crystal, achieving a relative systematic uncertainty of 2.5 × 10 − 18 and a relative frequency instability of 1.6 × 10 − 15 / τ / 1 s . We report on absolute frequency measurements with an uncertainty of 1.3 × 10 − 16 and optical frequency comparisons with clocks based on Yb + 171 ( E 3 ) and Sr 87 . With a fractional uncertainty of 4.4 × 10 − 18 , the former is—to our knowledge—the most accurate frequency ratio value reported to date. For the In + 115 / Sr 87 ratio, we improve upon the best previous measurement by more than an order of magnitude. We also demonstrate operation with four In + 115 clock ions, which reduces the instability to 9.2 × 10 − 16 / τ / 1 s .


  • Top Cited Papers
    Open Access

    Roadmap towards the redefinition of the second

    by Noel Dimarcq, Marina Gertsvolf, Gaetano Mileti, Sebastien Bize, Christopher Oates, Ekkehard Peik, Davide Calonico, Tetsuya Ido, Patrizia Tavella, Frédéric Meynadier, et al.

    This paper outlines the roadmap towards the redefinition of the second, which was recently updated by the CCTF Task Force created by the CCTF in 2020. The main achievements of optical frequency standards (OFS) call for reflection on the redefinition of the second, but open new challenges related to the performance of the OFS, their contribution to time scales and UTC, the possibility of their comparison, and the knowledge of the Earth’s gravitational potential to ensure a robust and accurate capacity to realize a new definition at the level of 10−18uncertainty. The mandatory criteria to be achieved before redefinition have been defined and their current fulfilment level is estimated showing the fields that still needed improvement. The possibility to base the redefinition on a single or on a set of transitions has also been evaluated. The roadmap indicates the steps to be followed in the next years to be ready for a sound and successful redefinition.


  • Open Access

    Continuous optical generation of microwave signals for fountain clocks

    by Burghard Lipphardt, Patrick Walkemeyer, Michael Kazda, Johannes Rahm, Stefan Weyers

    For the optical generation of ultrastable microwave signals for fountain clocks, we developed a setup based on a cavity stabilized laser and a commercial frequency comb. The robust system, in operation since 2020, is locked to a 100 MHz output frequency of a hydrogen maser and provides an ultrastable 9.6 GHz signal for the interrogation of atoms in two cesium fountain clocks, acting as primary frequency standards. Measurements reveal that the system provides a phase noise level that enables quantum projection noise limited fountain frequency instabilities at the low 10−14(τ/s)−1/2 level. At the same time, it offers largely maintenance-free operation.


  • GPS PPP-AR frequency transfer and its application for comparing atomic fountain primary frequency standards between NRC and PTB

    by Bin Jian, Scott Beattie, Stefan Weyers, Johannes Rahm, Brian Donahue, Marina Gertsvolf

    We report on the first characterization of the frequency transfer performance of the GPS precise point positioning with carrier-phase integer ambiguity resolution (PPP-AR) implemented by the Natural Resources Canada (NRCan) online service CSRS-PPP. We show that continuous PPP-AR links of multiple days can be formed by carefully fixing the day boundary phase discontinuity. The stability of the links can reach 7 × 10 − 16 and 1 × 10 − 16 (Allan deviation) at 1 d and 7 d averaging times, respectively, and mid to low 10−17 at 20 d–30 d. We compared the atomic fountain primary frequency standards (PFS) between NRC in Ottawa, Canada and PTB in Braunschweig, Germany for 135 d via GPS PPP-AR and precise point positioning links. The NRC and PTB PFS agree within a few parts in 1016, which is well below the combined systematic uncertainty. It is expected that with uncertainty at 10−17, the PPP-AR links will become a powerful tool for remote comparisons of atomic optical clocks, essential for the future redefinition of the SI second.


  • Top Cited Papers
    Open Access

    Improved Limits for Violations of Local Position Invariance from Atomic Clock Comparisons

    by R. Lange, N. Huntemann, J. M. Rahm, C. Sanner, H. Shao, B. Lipphardt, Chr. Tamm, S. Weyers, E. Peik

    We compare two optical clocks based on the S21/2(F=0)→D23/2(F=2) electric quadrupole (E2) and the S21/2(F=0)→F27/2(F=3) electric octupole (E3) transition of Yb171+ and measure the frequency ratio νE3/νE2=0.932829404530965376(32), improving upon previous measurements by an order of magnitude. Using two caesium fountain clocks, we find νE3=642121496772645.10(8)  Hz, the most accurate determination of an optical transition frequency to date. Repeated measurements of both quantities over several years are analyzed for potential violations of local position invariance. We improve by factors of about 20 and 2 the limits for fractional temporal variations of the fine structure constant α to 1.0(1.1)×10−18/yr and of the proton-to-electron mass ratio μ to −8(36)×10−18/yr. Using the annual variation of the Sun’s gravitational potential at Earth Φ, we improve limits for a potential coupling of both constants to gravity, (c2/α)(dα/dΦ)=14(11)×10−9 and (c2/μ)(dμ/dΦ)=7(45)×10−8.


  • Open Access

    Long term measurement of theSr87clock frequency at the limit of primary Cs clocks

    by R. Schwarz, S. Dörscher, A. Al-Masoudi, E. Benkler, T. Legero, U. Sterr, S. Weyers, J. Rahm, B. Lipphardt, C. Lisdat

    We report on a series of 42 measurements of the transition frequency of the 429 THz (5s2) S01–(5s5p) P03 line in Sr87 taken over three years from 2017 to 2019. They were performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as a flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of 429228004229873.00(0.07) Hz with 1.5×10−16 fractional uncertainty at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton-electron mass ratio μ and confirms the limits on the temporal drift of μ.


  • Open Access

    Direct comparisons of European primary and secondary frequency standards via satellite techniques

    by Franziska Riedel, Ali Al-Masoudi, Erik Benkler, Sören Dörscher, Vladislav Gerginov, Christian Grebing, Sebastian Häfner, Nils Huntemann, Burghard Lipphardt, Christian Lisdat, et al.

    We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of 1.8 × 10 −16 to 3.5 × 10 −16 for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of 6.9 × 10 −16 , and combined overall uncertainties in the range of 4.8 × 10 −16 to 7.7 × 10 −16 .