Paolo Durandetto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paolo Durandetto has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Eugenio Monticone
Istituto Nazionale di Ricerca Metrologica (INRiM)
9 shared publications - Andrea Sosso
Istituto Nazionale di Ricerca Metrologica (INRIM), Strada delle Cacce 91, Torino 10135, Italy
8 shared publications A. Sosso
INRiM - Istituto Nazionale di Ricerca Metrologica Strada delle Cacce, Torino, 91-10135, Italy
7 shared publicationsAndrea Sosso
INRIM - Istituto Nazionale di Ricerca Metrologica
5 shared publications- Matteo Fretto
Istituto Nazionale di Ricerca Metrologica (INRIM), Turin, Italy
5 shared publications B. Trinchera
4 shared publications
Latest Publications
- Open Access
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Metrological Assessment and Simulation of Charge Injection Phenomena in CMOS Electronic Switches
This paper presents the research activity and key findings from a technical task conducted as part of the True8DIGIT project, funded by the European Partnership on Metrology (EPM) research programme. A key objective of this activity was to develop a traceable metrological method for precisely characterizing the charge injection phenomenon in commercial CMOS switches, enabling the identification of top-performing devices with minimized charge-induced errors. These switches are critical components in the track-and-hold circuits of high-precision integrating digitizers, where charge injection introduces nonlinear distortions that ultimately degrade the digitizer’s accuracy. The proposed measurement method enables precise characterization of charge injection in discrete CMOS switches mounted in dedicated chip carriers, utilizing air-dielectric capacitor standards and a traceable digital sampling multimeter. Moreover, the temperature dependence of charge injection was investigated by modifying one of the carrier boards. The experimental setup achieves a resolution of 1 pC, and the Type-A uncertainty ranges from 10 fC to 70 fC, across different CMOS switches. The overall measurement uncertainties did not exceed 7% for charge injection values below 5 pC, and 3% for values between 50 pC to 350 pC. The lowest relative uncertainty achieved was below 0.5% for charge injection in the range 10 pC to 40 pC, indicating that charge injection behavior in CMOS switches is strongly dependent on the specific device under test.
- 27 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Open AccessMetrological Assessment and Simulation of Charge Injection Phenomena in CMOS Electronic Switches
This paper presents the research activity and key findings from a technical task conducted as part of the True8DIGIT project, funded by the European Partnership on Metrology (EPM) research programme. A key objective of this activity was to develop a traceable metrological method for precisely characterizing the charge injection phenomenon in commercial CMOS switches, enabling the identification of top-performing devices with minimized charge-induced errors. These switches are critical components in the track-and-hold circuits of high-precision integrating digitizers, where charge injection introduces nonlinear distortions that ultimately degrade the digitizer’s accuracy. The proposed measurement method enables precise characterization of charge injection in discrete CMOS switches mounted in dedicated chip carriers, utilizing air-dielectric capacitor standards and a traceable digital sampling multimeter. Moreover, the temperature dependence of charge injection was investigated by modifying one of the carrier boards. The experimental setup achieves a resolution of 1 pC, and the Type-A uncertainty ranges from 10 fC to 70 fC, across different CMOS switches. The overall measurement uncertainties did not exceed 7% for charge injection values below 5 pC, and 3% for values between 50 pC to 350 pC. The lowest relative uncertainty achieved was below 0.5% for charge injection in the range 10 pC to 40 pC, indicating that charge injection behavior in CMOS switches is strongly dependent on the specific device under test.
- Open Access
- 1 June 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (6) , 065013
Numerical analysis of Josephson junction arrays for multi-order quantum voltage steps
The dynamics of overdamped Josephson junctions under varying microwave-driving conditions have been studied through numerical simulations using the resistively-shunted junction model, with a focus on primary voltage metrology applications, where a significantly high number of series-connected junctions and stringent uniformity of their electrical parameters are required. The aim is to determine the optimal junction characteristics and external microwave (rf) parameters that maximize the width of quantum voltage levels (Shapiro steps) from order n = 0 to n > 1. Both the rf and dc power requirements, along with the junction parameter spread and power attenuation, are analyzed as key factors that need to be optimized for improved performance of the quantum device. This work aims to advance the development of next-generation programmable Josephson voltage standards with logic architectures that surpass the conventional binary and ternary codifications used in present quantum voltage arrays, while significantly reducing the overall number of junctions as well as the number of sub-arrays and bias lines. Existing technologies exploiting n = 0 and n = ± 1 voltage steps are first discussed and analyzed to verify the validity of the simulation model. They are then further investigated to extend their usability with multi-order quantum steps for n up to 3. From the simulation results, it follows that present junction technologies may be employed with no modifications for the simultaneous operation of quantum steps up to n = 2, although optimal power efficiency would require a retrimming of the junction’s electrical parameters. On the contrary, extending the highest step order to n = 3 strictly requires the junction’s characteristic parameters to be properly adjusted to maintain sustainable power levels as well as acceptable quantum-locking ranges.
- 1 June 2025
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 38 (6) , 065013
Open AccessNumerical analysis of Josephson junction arrays for multi-order quantum voltage steps
The dynamics of overdamped Josephson junctions under varying microwave-driving conditions have been studied through numerical simulations using the resistively-shunted junction model, with a focus on primary voltage metrology applications, where a significantly high number of series-connected junctions and stringent uniformity of their electrical parameters are required. The aim is to determine the optimal junction characteristics and external microwave (rf) parameters that maximize the width of quantum voltage levels (Shapiro steps) from order n = 0 to n > 1. Both the rf and dc power requirements, along with the junction parameter spread and power attenuation, are analyzed as key factors that need to be optimized for improved performance of the quantum device. This work aims to advance the development of next-generation programmable Josephson voltage standards with logic architectures that surpass the conventional binary and ternary codifications used in present quantum voltage arrays, while significantly reducing the overall number of junctions as well as the number of sub-arrays and bias lines. Existing technologies exploiting n = 0 and n = ± 1 voltage steps are first discussed and analyzed to verify the validity of the simulation model. They are then further investigated to extend their usability with multi-order quantum steps for n up to 3. From the simulation results, it follows that present junction technologies may be employed with no modifications for the simultaneous operation of quantum steps up to n = 2, although optimal power efficiency would require a retrimming of the junction’s electrical parameters. On the contrary, extending the highest step order to n = 3 strictly requires the junction’s characteristic parameters to be properly adjusted to maintain sustainable power levels as well as acceptable quantum-locking ranges.
- Open Access
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74, 1-15
Magnitude and Phase Calibration of Lock-In Amplifiers, and Analysis of the Noise Response
- 1 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74, 1-15
Open AccessMagnitude and Phase Calibration of Lock-In Amplifiers, and Analysis of the Noise Response
- Open Access
- 1 August 2023
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 12 (3) , 1-6
Recent advancements and perspectives of INRiM’s time-dependent Josephson voltage standards
Quantum voltage standards based on ac Josephson effect have been used in metrology since a few years after the discovery of the physical phenomenon. The role of quantum standards is now crucial following the SI redefinition in 2019: electrical units are today defined in terms of the fundamental constants e (elementary charge) and h (Planck’s constant). The extremely low uncertainty in dc measurements, that can be lower than 1 nV/V at 10 V, is stimulating research to extend application to ac and signals arbitrarily changing with time. Approaching the dc accuracy is challenging, however. The two main technologies used for the generation of non-steady voltage signals are programmable and pulsed Josephson junction arrays. In this work we discuss the main advancements obtained at the Italian Istituto Nazionale di Ricerca Metrologica (INRiM) with both technologies, and the most recent developments taking advantage of He-free device cooling techniques.
- 1 August 2023
- Published by IMEKO International Measurement Confederation in ACTA IMEKO
- Vol. 12 (3) , 1-6
Open AccessRecent advancements and perspectives of INRiM’s time-dependent Josephson voltage standards
Quantum voltage standards based on ac Josephson effect have been used in metrology since a few years after the discovery of the physical phenomenon. The role of quantum standards is now crucial following the SI redefinition in 2019: electrical units are today defined in terms of the fundamental constants e (elementary charge) and h (Planck’s constant). The extremely low uncertainty in dc measurements, that can be lower than 1 nV/V at 10 V, is stimulating research to extend application to ac and signals arbitrarily changing with time. Approaching the dc accuracy is challenging, however. The two main technologies used for the generation of non-steady voltage signals are programmable and pulsed Josephson junction arrays. In this work we discuss the main advancements obtained at the Italian Istituto Nazionale di Ricerca Metrologica (INRiM) with both technologies, and the most recent developments taking advantage of He-free device cooling techniques.
- 23 February 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 34 (4) , 045008
Using a Josephson junction as an effective on-chip temperature sensor
Temperature sensing and control are essential in experiments running in cryocooled systems, as with the case of liquid helium-free superconducting devices. A Josephson junction as on-chip temperature sensor operated in ac provides the highest sensitivity and minimal power loading to the cryogenic environment, thanks to the noise rejection of lock-in detection. To demonstrate the advantages of on-chip sensing, we tested it with a Josephson voltage standard array in cryocooler and compared with the conventional case of a sensor on the cold surface of the refrigerator, showing that the power dissipated within the chip may further increment the device temperature up to some tenths of kelvin. An ac Josephson junction sensor is proven to be capable of directly stabilizing the temperature of the superconductive circuit from fluctuations of dissipated power during operation. Reliability issues related to flux trapping are discussed and solutions are proposed suited to different applications. Overall, on-chip control with ac Josephson temperature sensing has the advantage of avoiding the complexities in minimization of cryogenic thermal links, virtually reducing to zero the contact resistance and keeping the operating temperature of the superconductor constant, independently of instantaneous operating power.
- 23 February 2021
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 34 (4) , 045008
Using a Josephson junction as an effective on-chip temperature sensor
Temperature sensing and control are essential in experiments running in cryocooled systems, as with the case of liquid helium-free superconducting devices. A Josephson junction as on-chip temperature sensor operated in ac provides the highest sensitivity and minimal power loading to the cryogenic environment, thanks to the noise rejection of lock-in detection. To demonstrate the advantages of on-chip sensing, we tested it with a Josephson voltage standard array in cryocooler and compared with the conventional case of a sensor on the cold surface of the refrigerator, showing that the power dissipated within the chip may further increment the device temperature up to some tenths of kelvin. An ac Josephson junction sensor is proven to be capable of directly stabilizing the temperature of the superconductive circuit from fluctuations of dissipated power during operation. Reliability issues related to flux trapping are discussed and solutions are proposed suited to different applications. Overall, on-chip control with ac Josephson temperature sensing has the advantage of avoiding the complexities in minimization of cryogenic thermal links, virtually reducing to zero the contact resistance and keeping the operating temperature of the superconductor constant, independently of instantaneous operating power.
- 29 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (4) , 1294-1301
Non-Conventional PJVS Exploiting First and Second Steps to Reduce Junctions and Bias Lines
- 29 April 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 69 (4) , 1294-1301
Non-Conventional PJVS Exploiting First and Second Steps to Reduce Junctions and Bias Lines
- 25 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 9 (7) , 1264-1270
Thermal Performances of an Improved Package for Cryocooled Josephson Standards
Complex cryogenics still represents a strong limitation to the spread of Josephson voltage standards and cryogen-free cooling is particularly suitable to simplify their operation. The main downsides of liquid helium-free systems are related to the chip thermalization: indeed, at low temperature the heat transfer between the chip and the coldplate of a cryocooler in vacuum is strongly affected by the quality of the interfaces. In order to increase the thermal performances of cryocooled programmable Josephson standards we devised and tested a special cryopackage: the chip is embedded into a sandwich structure with high thermal conductivity materials subject to a controlled mechanical pressure to reduce thermal contact resistances. A thin sapphire lamina placed upon the chip allows the heat to be dissipated from the top, thus creating an additional path for the thermal flow. A special bridge-like system with a screw is used as reproducible torque-to-force converter to exert known pressures to the sandwich. Furthermore, we analyzed the effect of thermal contraction to the actual pressure exerted on the chip, showing a non-negligible increase when cooled down to cryogenic temperature that can be calculated and corrected for.
- 25 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 9 (7) , 1264-1270
Thermal Performances of an Improved Package for Cryocooled Josephson Standards
Complex cryogenics still represents a strong limitation to the spread of Josephson voltage standards and cryogen-free cooling is particularly suitable to simplify their operation. The main downsides of liquid helium-free systems are related to the chip thermalization: indeed, at low temperature the heat transfer between the chip and the coldplate of a cryocooler in vacuum is strongly affected by the quality of the interfaces. In order to increase the thermal performances of cryocooled programmable Josephson standards we devised and tested a special cryopackage: the chip is embedded into a sandwich structure with high thermal conductivity materials subject to a controlled mechanical pressure to reduce thermal contact resistances. A thin sapphire lamina placed upon the chip allows the heat to be dissipated from the top, thus creating an additional path for the thermal flow. A special bridge-like system with a screw is used as reproducible torque-to-force converter to exert known pressures to the sandwich. Furthermore, we analyzed the effect of thermal contraction to the actual pressure exerted on the chip, showing a non-negligible increase when cooled down to cryogenic temperature that can be calculated and corrected for.
- Open Access
- 17 December 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (12) , e0209246
A modular and customizable open-source package for quantum voltage standards operation and control
This paper presents an open-source package developed in Python that controls and drives a programmable Josephson array to synthesize dc and ac quantum-accurate voltages. Programmable arrays are devices subdivided into independent subsections, each counting a number of series connected Josephson junctions that follows a binary sequence (1, 2, 4, 8, …) to control the output voltage. Our software allows to independently measure the current-voltage characteristics of each subsection by means of a set of arbitrary waveform generators and a nanovoltmeter that measures the voltage across the whole array with high sensitivity. A quantization test tool is also provided to check with sub-microvolt resolution whether the array is operating on its quantum margins. The code is modular and easily expandable with the support of many libraries, allowing prompt reconfiguration for different calibration and testing purposes. It is aimed at being a starting point for cooperation between National Metrology Institutes towards the realization of a shared quantum voltage calibration infrastructure.
- 17 December 2018
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 13 (12) , e0209246
Open AccessA modular and customizable open-source package for quantum voltage standards operation and control
This paper presents an open-source package developed in Python that controls and drives a programmable Josephson array to synthesize dc and ac quantum-accurate voltages. Programmable arrays are devices subdivided into independent subsections, each counting a number of series connected Josephson junctions that follows a binary sequence (1, 2, 4, 8, …) to control the output voltage. Our software allows to independently measure the current-voltage characteristics of each subsection by means of a set of arbitrary waveform generators and a nanovoltmeter that measures the voltage across the whole array with high sensitivity. A quantization test tool is also provided to check with sub-microvolt resolution whether the array is operating on its quantum margins. The code is modular and easily expandable with the support of many libraries, allowing prompt reconfiguration for different calibration and testing purposes. It is aimed at being a starting point for cooperation between National Metrology Institutes towards the realization of a shared quantum voltage calibration infrastructure.
- Open Access
- 1 October 2018
- Published by Elsevier in Data in Brief
- Vol. 20, 1468-1470
Data of cryocooler temperature dynamical response to time-varying power inputs at 4 K
- 1 October 2018
- Published by Elsevier in Data in Brief
- Vol. 20, 1468-1470
Open AccessData of cryocooler temperature dynamical response to time-varying power inputs at 4 K
- Open Access
- 1 August 2018
- Published by Elsevier in International Journal of Refrigeration
- Vol. 92, 125-132
Experimental analysis of the thermal behavior of a GM cryocooler based on linear system theory
- 1 August 2018
- Published by Elsevier in International Journal of Refrigeration
- Vol. 92, 125-132
Open AccessExperimental analysis of the thermal behavior of a GM cryocooler based on linear system theory