DRDaniel Richter

Daniel Richter

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daniel Richter has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Simultaneous MMC Readout Using a Tailored $\mu$MUX Based Readout System

    by D. Richter, M. Wegner, F. Ahrens, C. Enss, N. Karcher, O. Sander, C. Schuster, M. Weber, T. Wolber, S. Kempf

    Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with thousands to millions of individual pixels is the realization of a SQUID based multiplexing technique particularly tailored for MMC readout. Within this context, we report on the first demonstration of a frequency-division multiplexed readout of an MMC based detector array using both, a custom microwave SQUID multiplexer as well as a dedicated software-defined radio (SDR) readout electronics. We successfully performed a simultaneous readout up to eight multiplexer channels, each monitoring two detector pixels. We show that the signal shape is not changed as compared to a dc-SQUID readout and that similar values for the energy resolution can be obtained. Nevertheless, we observed an influence of the internal quality factor of the microwave resonators used for frequency encoding on the energy resolution that affects the resolution of the co-added sum spectrum.


  • Open Access

    Online Demodulation and Trigger for Flux-ramp Modulated SQUID Signals

    by N. Karcher, T. Muscheid, T. Wolber, D. Richter, C. Enss, S. Kempf, O. Sander

    Due to the periodic characteristics of SQUIDs, a suitable linearization technique is required for SQUID-based readout. Flux-ramp modulation is a common linearization technique and is typically applied for the readout of a microwave SQUID multiplexer as well as since recently also for dc-SQUIDs. Flux-ramp modulation requires another stage in the signal processing chain to demodulate the SQUID output signal before further processing. For cryogenic microcalorimeters, the signal contains events that are given by a fast exponentially rising and slowly exponentially decaying pulses shape. The events shall be detected by a trigger engine and recorded by a storage logic. Since the data rate can be decreased significantly by demodulation and event detection, it is desirable to do both steps on the deployed fast FPGA logic during measurement before passing the data to a general-purpose processor. In this contribution, we show the implementation of efficient multi-channel flux-ramp demodulation computed at run-time on a SoC-FPGA. Furthermore, a concept and implementation for an online trigger and buffer mechanism with its theoretical trigger loss rates depending on buffer size is presented. Both FPGA modules can be operated with up to 500 MHz clock frequency and can efficiently process 32 channels. Correct functionality and data reduction capability of the modules are demonstrated in measurements utilizing magnetic microcalorimeter irradiated with an Iron-55 source for event generation and read out by a microwave SQUID multiplexer.


  • Open Access

    Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer

    by Daniel Richter, Ludwig Hoibl, Thomas Wolber, Nick Karcher, Andreas Fleischmann, Christian Enss, Marc Weber, Oliver Sander, Sebastian Kempf

    We present a MHz frequency-division direct-current superconducting quantum interference device (dc-SQUID) multiplexer that is based on flux ramp modulation and a series array of N identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through additional modulation coils being tightly but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according to the sum of the flux-to-voltage characteristics of the individual SQUIDs within each cycle of the modulation signal. In this mode of operation, an input signal injected in the input coil of one of the SQUIDs and being quasi-static within a time frame adds a constant flux offset and leads to a phase shift of the associated SQUID characteristics. The latter is proportional to the input signal and can be inferred by channelizing and down-converting the sampled array output voltage. Using a prototype multiplexer as well as custom readout electronics, we demonstrate the simultaneous readout of four signal sources with MHz bandwidth per channel.


  • Open Access

    Proof of Concept for Through Silicon Vias (TSVs) in Application Specific Integrated Circuits (ASICs) for Hard X-ray Imaging Detectors

    by Jaesub Hong, Jonathan Grindlay, Branden Allen, Daniel P. Violette, Hiromasa Miyasaka, Dean Malta, Jennifer Ovental, David Bordelon, Daniel Richter

    Application Specific Integrated Circuits (ASICs) are commonly used to efficiently process the signals from sensors and detectors in space. Wire bonding is a space qualified technique of making interconnections between ASICs and their substrate packaging board for power, control and readout of the ASICs. Wire bonding is nearly ubiquitous in modern space programs, but their exposed wires can be prone to damage during assembly and subject to electric interference during operations. Additional space around the ASICs needed for wire bonding also impedes efficient packaging of large arrays of detectors. Here we introduce the Through Silicon Vias (TSV) technology that replaces wire bonds and eliminates their shortcomings. We have successfully demonstrated the feasibility of implementing TSVs to existing ASIC wafers (a.k.a. a via-last process) developed for processing the X-ray signals from the X-ray imaging CdZnTe detectors on the Nuclear Spectroscopic Telescope Array (NuSTAR) Small Explorer mission that was launched in 2012. While TSVs are common in the semiconductor industry, this is the first (to our knowledge) successful application for Astrophysics imaging instrumentation. We expect that the TSV technology will simplify the detector assembly, and thus will enable significant cost and schedule savings in assembly of large area CdZnTe detectors.

  • Dc-SQUID Readout with High Dynamic Range and Intrinsic MHz Frequency-Division Multiplexing Capability

    by Daniel Richter, Andreas Fleischmann, Christian Enss, Sebastian Kempf

    We present a novel dc-SQUID readout scheme that provides linearization of the relation between the input and output signal without using a conventional flux-locked loop circuit. It relies on applying a periodic, sawtooth-shaped magnetic flux signal to the modulation coil of the SQUID to continuously measure the flux-to-voltage SQUID characteristic within each period of the flux ramp. In case that the amplitude and repetition rate of the ramp are chosen such that multiple flux quanta are induced in the SQUID and that the input signal is quasistatic within one period of the flux ramp, the input signal adds a constant magnetic flux offset to the SQUID that leads to a phase shift of the SQUID characteristic being proportional to the input signal. We show that this scheme allows for significantly increasing the dynamic range and that it intrinsically allows for MHz frequency-division SQUID multiplexing.


  • Open Access

    Demonstration of a scalable frequency-domain readout of metallic magnetic calorimeters by means of a microwave SQUID multiplexer

    by Sebastian Kempf, Mathias Wegner, Andreas Fleischmann, Loredana Gastaldo, Felix Herrmann, Maximilian Papst, Daniel Richter, Christian Enss

    We report on the first demonstration of a scalable GHz frequency-domain readout of metallic magnetic calorimeters (MMCs) using a 64 pixel detector array that is read out by an integrated, on-chip microwave SQUID multiplexer. The detector array is optimized for detecting soft X-ray photons and the multiplexer is designed to provide a signal rise time τrise<400ns and an intrinsic energy sensitivity ϵ<30h . This results in an expected energy resolution ΔEFWHM<10eV . We measured a signal rise time τrise as low as 90ns and an energy resolution ΔEFWHM as low as 50eV for 5.9keV photons. The rise time is about an order of magnitude faster compared to other multiplexed low-temperature microcalorimeters and close to the intrinsic value set by the coupling between electron and spins. The energy resolution is degraded with respect to our design value due to a rather low intrinsic quality factor of the microwave resonators that is caused by the quality of the Josephson junction of the associated rf-SQUID as well as an elevated chip temperature as compared to the heat bath. Though the achieved energy resolution is not yet compatible with state-of-the-art single-channel MMCs, this demonstration of a scalable readout approach for MMCs in combination with the full understanding of the device performance showing ways how to improve represents an important milestone for the development of future large-scale MMC detector arrays.