Nick Karcher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nick Karcher has a total of 100 co-authors. Here are the top co-authors by number of shared publications:
- Oliver Sander
Institute for Data Processing and Electronics, Karlsruhe Institute of Technology, Eggenstein-Leopoldshafen, Germany
6 shared publications - Sebastian Kempf
Karlsruher Institut fr Technologie, Karlsruhe, Germany
5 shared publications C. Enss
Kirchhoff Institute for Physics, Heidelberg University, Heidelberg, Germany
3 shared publications- Christian Enss
Kirchhoff Institute for Physics, Heidelberg University, Heidelberg, Germany
3 shared publications - Daniel Richter
Kirchhoff Institute for Physics, Heidelberg University, Heidelberg, Germany
3 shared publications M. Weber
Institute for Data Processing and Electronics, Karlsruhe Institute of Technology, Karlsruhe, Germany
3 shared publications
Latest Publications
- Open Access
- 25 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (12) , 121801
Improved Limit on the Effective Electron Neutrino Mass with the ECHo-1k Experiment
The effective electron neutrino mass can be determined by analyzing the end-point region of the Ho 163 electron capture spectrum, provided a measurement with high-energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in Ho 163 Collaboration (ECHo) presents an analysis of the most precise Ho 163 spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of b const = 9.1 ( 1.3 ) × 10 − 6 eV/pixel/day was achieved allowing for a reliable analysis of the end-point region. The derived end-point energy Q = 2862 ( 4 ) eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of Q = 2863.2 ( 6 ) eV [Ch. Schweiger , ]. The upper limit of the effective electron neutrino mass is improved by almost a factor of 2 compared to the lowest current value [B. K. Alpert , ], reaching m ν e < 15 eV / c 2 (90% credible interval).
- 25 March 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (12) , 121801
Open AccessImproved Limit on the Effective Electron Neutrino Mass with the ECHo-1k Experiment
The effective electron neutrino mass can be determined by analyzing the end-point region of the Ho 163 electron capture spectrum, provided a measurement with high-energy resolution and high statistics using calorimetric techniques. Here, the Electron Capture in Ho 163 Collaboration (ECHo) presents an analysis of the most precise Ho 163 spectrum currently available, obtained with the ECHo-1k experiment and comprising about 200 million events. A very low background rate of b const = 9.1 ( 1.3 ) × 10 − 6 eV/pixel/day was achieved allowing for a reliable analysis of the end-point region. The derived end-point energy Q = 2862 ( 4 ) eV is in excellent agreement with the one independently determined via Penning-trap mass spectrometry of Q = 2863.2 ( 6 ) eV [Ch. Schweiger , ]. The upper limit of the effective electron neutrino mass is improved by almost a factor of 2 compared to the lowest current value [B. K. Alpert , ], reaching m ν e < 15 eV / c 2 (90% credible interval).
- Open Access
- 10 May 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Reconfigurable Technology and Systems
- Vol. 16 (2) , 1-23
QiCells: A Modular RFSoC-based Approach to Interface Superconducting Quantum Bits
Quantum computers will be a revolutionary extension of the heterogeneous computing world. They consist of many quantum bits (qubits) and require a careful design of the interface between the classical computer architecture and the quantum processor. For example, even single nanosecond variations of the interaction may have an influence on the quantum state. Designing a tailored interface electronics is therefore a major challenge, both in terms of signal integrity with respect to single channels, as well as the scaling of the signal count. We developed such an interface electronics, an RFSoC-based qubit control system called QiController. In this article, we present the modular FPGA firmware design of our system. It features so-called digital unit cells, or QiCells. Each cell contains all the logic necessary to interact with a single superconducting qubit, including a custom-built RISC-V-based sequencer. Synchronization and data exchange between the cells is facilitated using a special star-point structure. Versatile routing and frequency-division multiplexing of generated signals between QiCells and converters are also supported. High-level programmability is provided using a custom Python-based description language and an associated compiler. We furthermore provide the resource utilization of our design and demonstrate its correct operation using an actual superconducting five-qubit chip.
- 10 May 2023
- Published by Association for Computing Machinery (ACM) in ACM Transactions on Reconfigurable Technology and Systems
- Vol. 16 (2) , 1-23
Open AccessQiCells: A Modular RFSoC-based Approach to Interface Superconducting Quantum Bits
Quantum computers will be a revolutionary extension of the heterogeneous computing world. They consist of many quantum bits (qubits) and require a careful design of the interface between the classical computer architecture and the quantum processor. For example, even single nanosecond variations of the interaction may have an influence on the quantum state. Designing a tailored interface electronics is therefore a major challenge, both in terms of signal integrity with respect to single channels, as well as the scaling of the signal count. We developed such an interface electronics, an RFSoC-based qubit control system called QiController. In this article, we present the modular FPGA firmware design of our system. It features so-called digital unit cells, or QiCells. Each cell contains all the logic necessary to interact with a single superconducting qubit, including a custom-built RISC-V-based sequencer. Synchronization and data exchange between the cells is facilitated using a special star-point structure. Versatile routing and frequency-division multiplexing of generated signals between QiCells and converters are also supported. High-level programmability is provided using a custom Python-based description language and an associated compiler. We furthermore provide the resource utilization of our design and demonstrate its correct operation using an actual superconducting five-qubit chip.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Simultaneous MMC Readout Using a Tailored $\mu$MUX Based Readout System
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with thousands to millions of individual pixels is the realization of a SQUID based multiplexing technique particularly tailored for MMC readout. Within this context, we report on the first demonstration of a frequency-division multiplexed readout of an MMC based detector array using both, a custom microwave SQUID multiplexer as well as a dedicated software-defined radio (SDR) readout electronics. We successfully performed a simultaneous readout up to eight multiplexer channels, each monitoring two detector pixels. We show that the signal shape is not changed as compared to a dc-SQUID readout and that similar values for the energy resolution can be obtained. Nevertheless, we observed an influence of the internal quality factor of the microwave resonators used for frequency encoding on the energy resolution that affects the resolution of the co-added sum spectrum.
- 6 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Simultaneous MMC Readout Using a Tailored $\mu$MUX Based Readout System
Magnetic microcalorimeters (MMCs) are cryogenic, energy-dispersive single-particle detectors providing excellent energy resolution, intrinsically fast signal rise time, quantum efficiency close to 100%, large dynamic range as well as almost ideal linear response. One of the remaining challenges to be overcome to ultimately allow for the utilization of large-scale MMC based detector arrays with thousands to millions of individual pixels is the realization of a SQUID based multiplexing technique particularly tailored for MMC readout. Within this context, we report on the first demonstration of a frequency-division multiplexed readout of an MMC based detector array using both, a custom microwave SQUID multiplexer as well as a dedicated software-defined radio (SDR) readout electronics. We successfully performed a simultaneous readout up to eight multiplexer channels, each monitoring two detector pixels. We show that the signal shape is not changed as compared to a dc-SQUID readout and that similar values for the energy resolution can be obtained. Nevertheless, we observed an influence of the internal quality factor of the microwave resonators used for frequency encoding on the energy resolution that affects the resolution of the co-added sum spectrum.
- Open Access
- 26 September 2022
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 209 (3-4) , 581-588
Online Demodulation and Trigger for Flux-ramp Modulated SQUID Signals
Due to the periodic characteristics of SQUIDs, a suitable linearization technique is required for SQUID-based readout. Flux-ramp modulation is a common linearization technique and is typically applied for the readout of a microwave SQUID multiplexer as well as since recently also for dc-SQUIDs. Flux-ramp modulation requires another stage in the signal processing chain to demodulate the SQUID output signal before further processing. For cryogenic microcalorimeters, the signal contains events that are given by a fast exponentially rising and slowly exponentially decaying pulses shape. The events shall be detected by a trigger engine and recorded by a storage logic. Since the data rate can be decreased significantly by demodulation and event detection, it is desirable to do both steps on the deployed fast FPGA logic during measurement before passing the data to a general-purpose processor. In this contribution, we show the implementation of efficient multi-channel flux-ramp demodulation computed at run-time on a SoC-FPGA. Furthermore, a concept and implementation for an online trigger and buffer mechanism with its theoretical trigger loss rates depending on buffer size is presented. Both FPGA modules can be operated with up to 500 MHz clock frequency and can efficiently process 32 channels. Correct functionality and data reduction capability of the modules are demonstrated in measurements utilizing magnetic microcalorimeter irradiated with an Iron-55 source for event generation and read out by a microwave SQUID multiplexer.
- 26 September 2022
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 209 (3-4) , 581-588
Open AccessOnline Demodulation and Trigger for Flux-ramp Modulated SQUID Signals
Due to the periodic characteristics of SQUIDs, a suitable linearization technique is required for SQUID-based readout. Flux-ramp modulation is a common linearization technique and is typically applied for the readout of a microwave SQUID multiplexer as well as since recently also for dc-SQUIDs. Flux-ramp modulation requires another stage in the signal processing chain to demodulate the SQUID output signal before further processing. For cryogenic microcalorimeters, the signal contains events that are given by a fast exponentially rising and slowly exponentially decaying pulses shape. The events shall be detected by a trigger engine and recorded by a storage logic. Since the data rate can be decreased significantly by demodulation and event detection, it is desirable to do both steps on the deployed fast FPGA logic during measurement before passing the data to a general-purpose processor. In this contribution, we show the implementation of efficient multi-channel flux-ramp demodulation computed at run-time on a SoC-FPGA. Furthermore, a concept and implementation for an online trigger and buffer mechanism with its theoretical trigger loss rates depending on buffer size is presented. Both FPGA modules can be operated with up to 500 MHz clock frequency and can efficiently process 32 channels. Correct functionality and data reduction capability of the modules are demonstrated in measurements utilizing magnetic microcalorimeter irradiated with an Iron-55 source for event generation and read out by a microwave SQUID multiplexer.
- 11 June 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (6) , 064030
Quantum Nondemolition Dispersive Readout of a Superconducting Artificial Atom Using Large Photon Numbers
Reading out the state of superconducting artificial atoms typically relies on dispersive coupling to a readout resonator. For a given system noise temperature, increasing the circulating photon number in the resonator enables a shorter measurement time and is therefore expected to reduce readout errors caused by spontaneous atom transitions. However, increasing is generally observed to also monotonously increase these transition rates. Here we present a fluxonium artificial atom in which, despite the fact that the measured transition rates show nonmonotonous fluctuations within a factor of 6, for photon numbers up to , the signal-to-noise ratio continuously improves with increasing . Even without the use of a parametric amplifier, at , we achieve fidelities of 99% and 93% for feedback-assisted ground and excited state preparations, respectively. At higher , leakage outside the qubit computational space can no longer be neglected and it limits the fidelity of quantum state preparation.- 11 June 2021
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 15 (6) , 064030
Quantum Nondemolition Dispersive Readout of a Superconducting Artificial Atom Using Large Photon Numbers
Reading out the state of superconducting artificial atoms typically relies on dispersive coupling to a readout resonator. For a given system noise temperature, increasing the circulating photon number in the resonator enables a shorter measurement time and is therefore expected to reduce readout errors caused by spontaneous atom transitions. However, increasing is generally observed to also monotonously increase these transition rates. Here we present a fluxonium artificial atom in which, despite the fact that the measured transition rates show nonmonotonous fluctuations within a factor of 6, for photon numbers up to , the signal-to-noise ratio continuously improves with increasing . Even without the use of a parametric amplifier, at , we achieve fidelities of 99% and 93% for feedback-assisted ground and excited state preparations, respectively. At higher , leakage outside the qubit computational space can no longer be neglected and it limits the fidelity of quantum state preparation.- 27 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (8) , 1899-1906
Versatile Configuration and Control Framework for Real-Time Data Acquisition Systems
Modern physics experiments often utilize field-programmable gate array (FPGA)-based systems for real-time data acquisition (DAQ). Integrated analog electronics demand for complex calibration routines. Furthermore, versatile configuration and control of the whole system are key requirements. Besides a low-level register interface to the FPGA, also, access to I 2 C and SPI buses is often needed to configure the complete system. Calibration through an FPGA is inflexible and yields a complex hardware implementation. On the contrary, calibration through a remote system is possible but considerably slower due to repetitive network accesses. By using system-on-chip (SoC)-FPGA solutions with a microprocessor, more sophisticated configuration and calibration solutions, as well as standard remote access protocols, can be efficiently integrated into the software. Based on Xilinx Zynq US+ SoC-FPGAs, we implemented a versatile control framework. This software framework offers convenient access to the hardware and a flexible abstraction via remote-procedure calls (RPCs). Based on the open-source RPC library gRPC, functionality with low-latency control flow, complex algorithms, data conversions and processing, and configuration via external buses can be provided to a client via Ethernet. Furthermore, client interfaces for various programming languages can be generated automatically, which eases collaboration among different working groups and integration into existing software. This contribution presents the framework and benchmarks regarding latency and data throughput.
- 27 May 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 68 (8) , 1899-1906
Versatile Configuration and Control Framework for Real-Time Data Acquisition Systems
Modern physics experiments often utilize field-programmable gate array (FPGA)-based systems for real-time data acquisition (DAQ). Integrated analog electronics demand for complex calibration routines. Furthermore, versatile configuration and control of the whole system are key requirements. Besides a low-level register interface to the FPGA, also, access to I 2 C and SPI buses is often needed to configure the complete system. Calibration through an FPGA is inflexible and yields a complex hardware implementation. On the contrary, calibration through a remote system is possible but considerably slower due to repetitive network accesses. By using system-on-chip (SoC)-FPGA solutions with a microprocessor, more sophisticated configuration and calibration solutions, as well as standard remote access protocols, can be efficiently integrated into the software. Based on Xilinx Zynq US+ SoC-FPGAs, we implemented a versatile control framework. This software framework offers convenient access to the hardware and a flexible abstraction via remote-procedure calls (RPCs). Based on the open-source RPC library gRPC, functionality with low-latency control flow, complex algorithms, data conversions and processing, and configuration via external buses can be provided to a client via Ethernet. Furthermore, client interfaces for various programming languages can be generated automatically, which eases collaboration among different working groups and integration into existing software. This contribution presents the framework and benchmarks regarding latency and data throughput.
- Open Access
- 22 March 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 118 (12) , 122601
Flux ramp modulation based MHz frequency-division dc-SQUID multiplexer
We present a MHz frequency-division direct-current superconducting quantum interference device (dc-SQUID) multiplexer that is based on flux ramp modulation and a series array of N identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through additional modulation coils being tightly but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according to the sum of the flux-to-voltage characteristics of the individual SQUIDs within each cycle of the modulation signal. In this mode of operation, an input signal injected in the input coil of one of the SQUIDs and being quasi-static within a time frame adds a constant flux offset and leads to a phase shift of the associated SQUID characteristics. The latter is proportional to the input signal and can be inferred by channelizing and down-converting the sampled array output voltage. Using a prototype multiplexer as well as custom readout electronics, we demonstrate the simultaneous readout of four signal sources with MHz bandwidth per channel.
- 22 March 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 118 (12) , 122601
Open AccessFlux ramp modulation based MHz frequency-division dc-SQUID multiplexer
We present a MHz frequency-division direct-current superconducting quantum interference device (dc-SQUID) multiplexer that is based on flux ramp modulation and a series array of N identical current-sensing dc-SQUIDs with tightly coupled input coil. By running a periodic, sawtooth-shaped current signal through additional modulation coils being tightly but non-uniformly coupled to the individual SQUIDs, the voltage drop across the array changes according to the sum of the flux-to-voltage characteristics of the individual SQUIDs within each cycle of the modulation signal. In this mode of operation, an input signal injected in the input coil of one of the SQUIDs and being quasi-static within a time frame adds a constant flux offset and leads to a phase shift of the associated SQUID characteristics. The latter is proportional to the input signal and can be inferred by channelizing and down-converting the sampled array output voltage. Using a prototype multiplexer as well as custom readout electronics, we demonstrate the simultaneous readout of four signal sources with MHz bandwidth per channel.
- 11 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 28 (10709908) , 41-45
Readout of Energy Pulses on Microwave SQUID Multiplexer: A Sensor Array-Based Approach
Suitable techniques for reading out large arrays of metallic magnetic calorimeters are very challenging and demand optimal performance in each system stage to preserve intrinsic fast signal rise time, excellent energy resolution, large energy dynamic range, and highly linear detector response. A multiplexer based on superconducting quantum interference device is the key component in achieving this goal. Linearity of the response requires a technique called flux-ramp modulation, which generates a phase-modulated complex waveform according to the sensor signal. At the end-cap of the signal processing chain it is currently recovered by a demodulation process referred to as Fourier measurement. In this paper, we prove that the mentioned method is equivalent to a maximum likelihood estimation, build an analogy to the sensor array-based direction of arrival estimation, propose an alternative approach based on the eigenvalue decomposition of a correlation matrix, present the mathematical formulation, discuss the results, and compare both methods. Our method is robust against transients due to flux ramp returning point and allows proper estimation in large phase ranges.
- 11 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Signal Processing Letters
- Vol. 28 (10709908) , 41-45
Readout of Energy Pulses on Microwave SQUID Multiplexer: A Sensor Array-Based Approach
Suitable techniques for reading out large arrays of metallic magnetic calorimeters are very challenging and demand optimal performance in each system stage to preserve intrinsic fast signal rise time, excellent energy resolution, large energy dynamic range, and highly linear detector response. A multiplexer based on superconducting quantum interference device is the key component in achieving this goal. Linearity of the response requires a technique called flux-ramp modulation, which generates a phase-modulated complex waveform according to the sensor signal. At the end-cap of the signal processing chain it is currently recovered by a demodulation process referred to as Fourier measurement. In this paper, we prove that the mentioned method is equivalent to a maximum likelihood estimation, build an analogy to the sensor array-based direction of arrival estimation, propose an alternative approach based on the eigenvalue decomposition of a correlation matrix, present the mathematical formulation, discuss the results, and compare both methods. Our method is robust against transients due to flux ramp returning point and allows proper estimation in large phase ranges.
- Open Access
Versatile Configuration and Control Framework for Real Time Data Acquisition Systems
Modern physics experiments often utilize FPGA-based systems for real-time data acquisition. Integrated analog electronics demand for complex calibration routines. Furthermore, versatile configuration and control of the whole system is a key requirement. Beside low-level register interface to the FPGA, also access to I$^2$C and SPI buses is often needed to configure the complete system. Calibration through an FPGA is inflexible and yields a complex hardware implementation. On the contrary, calibration through a remote system is possible but considerably slower due to repetitive network accesses. By using SoC-FPGA solutions with a microprocessor, more sophisticated configuration and calibration solutions, as well as standard remote access protocols, can be efficiently integrated in software. Based on Xilinx Zynq US+ SoC-FPGAs, we implemented a versatile control framework. This software framework offers a convenient access to the hardware and a flexible abstraction via remote-procedure calls (RPCs). Based on the open source RPC library gRPC, functionality with low-latent control flow, complex algorithms, data conversions and processing, as well as configuration via external buses can be provided to a client via Ethernet. Furthermore, client interfaces for various programming languages can be generated automatically which eases collaboration among different working groups and integration into existing software. This contribution presents the framework as well as benchmarks regarding latency and data throughput.
Open AccessVersatile Configuration and Control Framework for Real Time Data Acquisition Systems
Modern physics experiments often utilize FPGA-based systems for real-time data acquisition. Integrated analog electronics demand for complex calibration routines. Furthermore, versatile configuration and control of the whole system is a key requirement. Beside low-level register interface to the FPGA, also access to I$^2$C and SPI buses is often needed to configure the complete system. Calibration through an FPGA is inflexible and yields a complex hardware implementation. On the contrary, calibration through a remote system is possible but considerably slower due to repetitive network accesses. By using SoC-FPGA solutions with a microprocessor, more sophisticated configuration and calibration solutions, as well as standard remote access protocols, can be efficiently integrated in software. Based on Xilinx Zynq US+ SoC-FPGAs, we implemented a versatile control framework. This software framework offers a convenient access to the hardware and a flexible abstraction via remote-procedure calls (RPCs). Based on the open source RPC library gRPC, functionality with low-latent control flow, complex algorithms, data conversions and processing, as well as configuration via external buses can be provided to a client via Ethernet. Furthermore, client interfaces for various programming languages can be generated automatically which eases collaboration among different working groups and integration into existing software. This contribution presents the framework as well as benchmarks regarding latency and data throughput.
- Open Access
- 30 April 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 200 (5-6) , 261-268
SDR-Based Readout Electronics for the ECHo Experiment
Due to their excellent energy resolution, the intrinsically fast signal rise time, the huge energy dynamic range, and the almost ideally linear detector response, metallic magnetic calorimeters (MMC)s are very well suited for a variety of applications in physics. In particular, the ECHo experiment aims to utilize large-scale MMC-based detector arrays to investigate the mass of the electron neutrino. Reading out such arrays is a challenging task which can be tackled using microwave SQUID multiplexing. Here, the detector signals are transduced into frequency shifts of superconducting microwave resonators, which can be deduced using a high-end software-defined radio (SDR) system. The ECHo SDR system is a custom-made modular electronics, which provides 400 channels equally distributed in a 4 to 8 GHz frequency band. The system consists of a superheterodyne RF frequency converter with two successive mixers, a modular conversion, and an FPGA board. For channelization, a novel heterogeneous approach, utilizing the integrated digital down conversion (DDC) of the ADC, a polyphase channelizer, and another DDC for demodulation, is proposed. This approach has excellent channelization properties while being resource-efficient at the same time. After signal demodulation, on-FPGA flux-ramp demodulation processes the signals before streaming it to the data processing and storage backend.
- 30 April 2020
- Published by Springer Nature in Journal of Low Temperature Physics
- Vol. 200 (5-6) , 261-268
Open AccessSDR-Based Readout Electronics for the ECHo Experiment
Due to their excellent energy resolution, the intrinsically fast signal rise time, the huge energy dynamic range, and the almost ideally linear detector response, metallic magnetic calorimeters (MMC)s are very well suited for a variety of applications in physics. In particular, the ECHo experiment aims to utilize large-scale MMC-based detector arrays to investigate the mass of the electron neutrino. Reading out such arrays is a challenging task which can be tackled using microwave SQUID multiplexing. Here, the detector signals are transduced into frequency shifts of superconducting microwave resonators, which can be deduced using a high-end software-defined radio (SDR) system. The ECHo SDR system is a custom-made modular electronics, which provides 400 channels equally distributed in a 4 to 8 GHz frequency band. The system consists of a superheterodyne RF frequency converter with two successive mixers, a modular conversion, and an FPGA board. For channelization, a novel heterogeneous approach, utilizing the integrated digital down conversion (DDC) of the ADC, a polyphase channelizer, and another DDC for demodulation, is proposed. This approach has excellent channelization properties while being resource-efficient at the same time. After signal demodulation, on-FPGA flux-ramp demodulation processes the signals before streaming it to the data processing and storage backend.