Scott J. Thompson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Scott J. Thompson has a total of 145 co-authors. Here are the top co-authors by number of shared publications:
- David L. Chichester
Idaho National Laboratory, Idaho Falls, USA
16 shared publications - James T. Johnson
Idaho National Laboratory
15 shared publications - Luis A. Ocampo Giraldo
Idaho National Laboratory, Idaho Falls, ID 83415, USA
10 shared publications - Jay D. Hix
Idaho National Laboratory
8 shared publications David L. Chichester
Idaho National Laboratory, Idaho Falls, ID 83415 USA
5 shared publicationsUsdoe National Nuclear Security Administration (Nnsa)
5 shared publications
Latest Publications
- 1 October 2025
- Published by Office of Scientific and Technical Information (OSTI)
Unattended Monitoring of Uranium Holdup with Scintillating Fibers
This work evaluated the use of scintillating fiber (SciFi) radiation sensors as a cost-effective, unattended monitoring technique for uranium holdup accumulation in reprocessing equipment. With ruggedized packaging and an outer diameter of less than 1 cm, scintillating fibers offer deployment flexibility. Additionally, plastic scintillating fibers coupled with standard optical fibers provide an affordable option to monitor locations kilometers away from a localized control room or data acquisition (DAQ) system. These combinations of characteristics along with their relatively low manufacturing costs make scintillating fibers ideal for installation at key measurement points such as pipes, valves, and filtration systems.
- 1 October 2025
- Published by Office of Scientific and Technical Information (OSTI)
Unattended Monitoring of Uranium Holdup with Scintillating Fibers
This work evaluated the use of scintillating fiber (SciFi) radiation sensors as a cost-effective, unattended monitoring technique for uranium holdup accumulation in reprocessing equipment. With ruggedized packaging and an outer diameter of less than 1 cm, scintillating fibers offer deployment flexibility. Additionally, plastic scintillating fibers coupled with standard optical fibers provide an affordable option to monitor locations kilometers away from a localized control room or data acquisition (DAQ) system. These combinations of characteristics along with their relatively low manufacturing costs make scintillating fibers ideal for installation at key measurement points such as pipes, valves, and filtration systems.
- Open Access
- 30 September 2024
- Published by Office of Scientific and Technical Information (OSTI)
FASTPAC - Direct Alpha Spectrometry of Nuclear Fallout - NFUG2024 [Slides]
These are slides for the upcoming FNUG forensics meeting with the UK. These slides have been completely taken from previously released presentation - INL-CON-23-71391. I am resubmitting to LRS for completeness.
- 30 September 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessFASTPAC - Direct Alpha Spectrometry of Nuclear Fallout - NFUG2024 [Slides]
These are slides for the upcoming FNUG forensics meeting with the UK. These slides have been completely taken from previously released presentation - INL-CON-23-71391. I am resubmitting to LRS for completeness.
- Open Access
- 20 February 2024
- Published by Office of Scientific and Technical Information (OSTI)
Comparative Analysis of Explosion Signals on Smartphones and Seismometers [Poster]
Seismoacoustic signatures from a chemical explosion was recorded on two seismometers and eight smartphone accelerometers at Idaho National Laboratory (INL). The captured waveform’s propagation and its time frequency representations are compared. The smartphone accelerometers were able to pick up a clear seismoacoustic explosion signal at within 1 km (150 m/kg1/3) and a noisy signal up to 5.3 km (790 m/kg1/3).
- 20 February 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessComparative Analysis of Explosion Signals on Smartphones and Seismometers [Poster]
Seismoacoustic signatures from a chemical explosion was recorded on two seismometers and eight smartphone accelerometers at Idaho National Laboratory (INL). The captured waveform’s propagation and its time frequency representations are compared. The smartphone accelerometers were able to pick up a clear seismoacoustic explosion signal at within 1 km (150 m/kg1/3) and a noisy signal up to 5.3 km (790 m/kg1/3).
- Open Access
- 1 September 2023
- Published by Office of Scientific and Technical Information (OSTI)
Long-length Scintillating Fibers for Nuclear Waste Repository [Poster]
Containment verification in inaccessible radiological & nuclear waste repositories
- 1 September 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessLong-length Scintillating Fibers for Nuclear Waste Repository [Poster]
Containment verification in inaccessible radiological & nuclear waste repositories
- Open Access
- 22 May 2023
- Published by Office of Scientific and Technical Information (OSTI)
Assembly and Initial Testing of the Gamma-Ray Emission Tomography Assessment Prototype for Irradiated Fuel
The following report documents the final development, assembly, and initial testing of the gamma-ray emission tomography assessment system (GRETA-1) for post-irradiation examination of irradiated fuel. It includes descriptions of the system components, including the high-purity germanium gamma-ray detector, the surrounding shield and collimator, the sample scanning hardware, and the control and collection software package. A series of MCNP6 simulations were performed that modeled a fuel rod scan to test image reconstruction algorithms with a complex and understood source distribution. A bench-top scan of isotopic check sources was also performed and analyzed using standard image reconstruction algorithms. The system is currently awaiting deployment at Idaho National Laboratory’s Hot Fuel Examination Facility.
- 22 May 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessAssembly and Initial Testing of the Gamma-Ray Emission Tomography Assessment Prototype for Irradiated Fuel
The following report documents the final development, assembly, and initial testing of the gamma-ray emission tomography assessment system (GRETA-1) for post-irradiation examination of irradiated fuel. It includes descriptions of the system components, including the high-purity germanium gamma-ray detector, the surrounding shield and collimator, the sample scanning hardware, and the control and collection software package. A series of MCNP6 simulations were performed that modeled a fuel rod scan to test image reconstruction algorithms with a complex and understood source distribution. A bench-top scan of isotopic check sources was also performed and analyzed using standard image reconstruction algorithms. The system is currently awaiting deployment at Idaho National Laboratory’s Hot Fuel Examination Facility.
- Open Access
- 3 May 2023
- Published by Office of Scientific and Technical Information (OSTI)
Field Scoping Study of Gamma-Ray Measurement of UF6 Cristillini Samples with CZT and HPGe Detectors
A field scoping study was conducted to evaluate the ability of Cd-Zn-Te (CZT) detectors and High Purity Germanium (HPGe) detectors to quantify the U-235 enrichment in UF6 samples collected on alumina in P-10 tubes, similar to the Cristillini method of sample collection for analysis by mass spectrometry. With in-field gamma-ray spectroscopy methods, international safeguards and verification missions could benefit from quick in-field confirmation of declared enrichment values prior to or without the need for additional shipping, sample preparation and analysis. Samples of depleted (DU), low-enriched (LEU) and high-assay low-enriched (HALEU) uranium were collected on Cristillini-type alumina in P-10 tubes and measured with two H3D, Inc. M400 CZT detectors as well as a Canberra Falcon HPGe detector. The M400 detectors were able to confirm enrichment in the DU and LEU samples but not the HALEU sample in measurements 8-40 hrs after collection. The Falcon system was able to confirm enrichment in all three samples. Improvements in detector geometry, increase in number of detectors as well as increase sample mass loading may allow measurement of U-235 enrichment in these types of samples within 4-8hrs of collection with 5-10% uncertainty.
- 3 May 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessField Scoping Study of Gamma-Ray Measurement of UF6 Cristillini Samples with CZT and HPGe Detectors
A field scoping study was conducted to evaluate the ability of Cd-Zn-Te (CZT) detectors and High Purity Germanium (HPGe) detectors to quantify the U-235 enrichment in UF6 samples collected on alumina in P-10 tubes, similar to the Cristillini method of sample collection for analysis by mass spectrometry. With in-field gamma-ray spectroscopy methods, international safeguards and verification missions could benefit from quick in-field confirmation of declared enrichment values prior to or without the need for additional shipping, sample preparation and analysis. Samples of depleted (DU), low-enriched (LEU) and high-assay low-enriched (HALEU) uranium were collected on Cristillini-type alumina in P-10 tubes and measured with two H3D, Inc. M400 CZT detectors as well as a Canberra Falcon HPGe detector. The M400 detectors were able to confirm enrichment in the DU and LEU samples but not the HALEU sample in measurements 8-40 hrs after collection. The Falcon system was able to confirm enrichment in all three samples. Improvements in detector geometry, increase in number of detectors as well as increase sample mass loading may allow measurement of U-235 enrichment in these types of samples within 4-8hrs of collection with 5-10% uncertainty.
- Open Access
- 31 January 2023
- Published by Office of Scientific and Technical Information (OSTI)
Simulation Study of Monoenergetic Photon Source LiDAR System Performance for Emergency Response Applications
The following report summarizes the results of a Monte Carlo simulation and modeling study of the Lawrence Berkeley National Laboratory’s (LBL) Monoenergetic Photon Source (MPS) as part of a high-energy LiDAR system for use in emergency response applications. A set of image quality indicators (IQI) and nonsensitive phantoms or generalized surrogates for search targets have been identified for use in the planned measurement campaign at the Berkeley Lab Laser Accelerator (BELLA) Center toward the end FY2023. These items were modeled and the time-of-flight (TOF) spectral responses following irradiation were calculated for a set of varying operating conditions. The goal of this study was to both predict the LiDAR system performance as well as determine if minor modifications to the IQI and phantom designs were required before fabrication. It was found that the IQI and target designs both overlap and extend towards the limit of performance of the system and are thus suitable for the final project measurement campaign.
- 31 January 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessSimulation Study of Monoenergetic Photon Source LiDAR System Performance for Emergency Response Applications
The following report summarizes the results of a Monte Carlo simulation and modeling study of the Lawrence Berkeley National Laboratory’s (LBL) Monoenergetic Photon Source (MPS) as part of a high-energy LiDAR system for use in emergency response applications. A set of image quality indicators (IQI) and nonsensitive phantoms or generalized surrogates for search targets have been identified for use in the planned measurement campaign at the Berkeley Lab Laser Accelerator (BELLA) Center toward the end FY2023. These items were modeled and the time-of-flight (TOF) spectral responses following irradiation were calculated for a set of varying operating conditions. The goal of this study was to both predict the LiDAR system performance as well as determine if minor modifications to the IQI and phantom designs were required before fabrication. It was found that the IQI and target designs both overlap and extend towards the limit of performance of the system and are thus suitable for the final project measurement campaign.
- Open Access
- 1 November 2022
- Published by Office of Scientific and Technical Information (OSTI)
Preliminary Design Needs for High-Temperature Heat Pipe Imaging System
This report provides preliminary design needs for radiological imaging heat pipes to perform in operando assessment for high-temperature alkaline metal charged heat pipes (HPs). The measurement parameters of interest have been summarized for characterizing the operando HP behavior. Based on the current SPHERE experimental facility, the needs and modifications required for the experimental setup have also been identified to enable the X-ray-assisted visualizations for the single HP during its operating conditions.
- 1 November 2022
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessPreliminary Design Needs for High-Temperature Heat Pipe Imaging System
This report provides preliminary design needs for radiological imaging heat pipes to perform in operando assessment for high-temperature alkaline metal charged heat pipes (HPs). The measurement parameters of interest have been summarized for characterizing the operando HP behavior. Based on the current SPHERE experimental facility, the needs and modifications required for the experimental setup have also been identified to enable the X-ray-assisted visualizations for the single HP during its operating conditions.
- Open Access
- 30 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
TRIPWIRE Deployment and Field Testing Results Report
TRIPWIRE is a multi-modal system for containment verification in inaccessible radiological and nuclear waste repositories. The sensing modes are focused on radiation, electromagnetic and vibration. The radiation detection component has been developed over the last three years at Idaho National Laboratory (INL). This development has focused on the fabrication, characterization, and testing of long-length (greater than 10-m) plastic scintillating fibers. This fiscal year, the focus of TRIPWIRE has been on field testing and demonstration of the radiation sensing component in a relevant environment. After reviewing the static storage facilities at INL, the Radioactive Scrap Waste Facility (RSWF) south storage area outside the Materials and Fuels Complex (MFC) was selected due to its periodic changes in configuration and inventory. This report summarizes the research outcomes for the work performed in fiscal year (FY) 2023.
- 30 September 2022
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessTRIPWIRE Deployment and Field Testing Results Report
TRIPWIRE is a multi-modal system for containment verification in inaccessible radiological and nuclear waste repositories. The sensing modes are focused on radiation, electromagnetic and vibration. The radiation detection component has been developed over the last three years at Idaho National Laboratory (INL). This development has focused on the fabrication, characterization, and testing of long-length (greater than 10-m) plastic scintillating fibers. This fiscal year, the focus of TRIPWIRE has been on field testing and demonstration of the radiation sensing component in a relevant environment. After reviewing the static storage facilities at INL, the Radioactive Scrap Waste Facility (RSWF) south storage area outside the Materials and Fuels Complex (MFC) was selected due to its periodic changes in configuration and inventory. This report summarizes the research outcomes for the work performed in fiscal year (FY) 2023.