David L. Chichester
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
David L. Chichester has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- James T. Johnson
Idaho National Laboratory
22 shared publications - Luis A. Ocampo Giraldo
Idaho National Laboratory, Idaho Falls, ID 83415, USA
16 shared publications - Scott J. Thompson
Idaho National Laboratory
16 shared publications Usdoe National Nuclear Security Administration (Nnsa)
13 shared publications- Jay D. Hix
Idaho National Laboratory
10 shared publications - Scott M. Watson
Idaho National Laboratory (INL), Idaho Falls, ID (United States)
8 shared publications
Latest Publications
- 1 October 2025
- Published by Office of Scientific and Technical Information (OSTI)
Unattended Monitoring of Uranium Holdup with Scintillating Fibers
This work evaluated the use of scintillating fiber (SciFi) radiation sensors as a cost-effective, unattended monitoring technique for uranium holdup accumulation in reprocessing equipment. With ruggedized packaging and an outer diameter of less than 1 cm, scintillating fibers offer deployment flexibility. Additionally, plastic scintillating fibers coupled with standard optical fibers provide an affordable option to monitor locations kilometers away from a localized control room or data acquisition (DAQ) system. These combinations of characteristics along with their relatively low manufacturing costs make scintillating fibers ideal for installation at key measurement points such as pipes, valves, and filtration systems.
- 1 October 2025
- Published by Office of Scientific and Technical Information (OSTI)
Unattended Monitoring of Uranium Holdup with Scintillating Fibers
This work evaluated the use of scintillating fiber (SciFi) radiation sensors as a cost-effective, unattended monitoring technique for uranium holdup accumulation in reprocessing equipment. With ruggedized packaging and an outer diameter of less than 1 cm, scintillating fibers offer deployment flexibility. Additionally, plastic scintillating fibers coupled with standard optical fibers provide an affordable option to monitor locations kilometers away from a localized control room or data acquisition (DAQ) system. These combinations of characteristics along with their relatively low manufacturing costs make scintillating fibers ideal for installation at key measurement points such as pipes, valves, and filtration systems.
- Open Access
Explosion Detection Using Smartphones: Ensemble Learning with the Smartphone High-Explosive Audio Recordings Dataset and the ESC-50 Dataset
Explosion monitoring is performed by infrasound and seismoacoustic sensor networks that are distributed globally, regionally, and locally. However, these networks are unevenly and sparsely distributed, especially at the local scale, as maintaining and deploying networks is costly. With increasing interest in smaller-yield explosions, the need for more dense networks has increased. To address this issue, we propose using smartphone sensors for explosion detection as they are cost-effective and easy to deploy. Although there are studies using smartphone sensors for explosion detection, the field is still in its infancy and new technologies need to be developed. We applied a machine learning model for explosion detection using smartphone microphones. The data used were from the Smartphone High-explosive Audio Recordings Dataset (SHAReD), a collection of 326 waveforms from 70 high-explosive (HE) events recorded on smartphones, and the ESC-50 dataset, a benchmarking dataset commonly used for environmental sound classification. Two machine learning models were trained and combined into an ensemble model for explosion detection. The resulting ensemble model classified audio signals as either “explosion”, “ambient”, or “other” with true positive rates (recall) greater than 96% for all three categories.
Open AccessExplosion Detection Using Smartphones: Ensemble Learning with the Smartphone High-Explosive Audio Recordings Dataset and the ESC-50 Dataset
Explosion monitoring is performed by infrasound and seismoacoustic sensor networks that are distributed globally, regionally, and locally. However, these networks are unevenly and sparsely distributed, especially at the local scale, as maintaining and deploying networks is costly. With increasing interest in smaller-yield explosions, the need for more dense networks has increased. To address this issue, we propose using smartphone sensors for explosion detection as they are cost-effective and easy to deploy. Although there are studies using smartphone sensors for explosion detection, the field is still in its infancy and new technologies need to be developed. We applied a machine learning model for explosion detection using smartphone microphones. The data used were from the Smartphone High-explosive Audio Recordings Dataset (SHAReD), a collection of 326 waveforms from 70 high-explosive (HE) events recorded on smartphones, and the ESC-50 dataset, a benchmarking dataset commonly used for environmental sound classification. Two machine learning models were trained and combined into an ensemble model for explosion detection. The resulting ensemble model classified audio signals as either “explosion”, “ambient”, or “other” with true positive rates (recall) greater than 96% for all three categories.
- Open Access
- 30 September 2024
- Published by Office of Scientific and Technical Information (OSTI)
FASTPAC - Direct Alpha Spectrometry of Nuclear Fallout - NFUG2024 [Slides]
These are slides for the upcoming FNUG forensics meeting with the UK. These slides have been completely taken from previously released presentation - INL-CON-23-71391. I am resubmitting to LRS for completeness.
- 30 September 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessFASTPAC - Direct Alpha Spectrometry of Nuclear Fallout - NFUG2024 [Slides]
These are slides for the upcoming FNUG forensics meeting with the UK. These slides have been completely taken from previously released presentation - INL-CON-23-71391. I am resubmitting to LRS for completeness.
- Open Access
- 1 September 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (3) , 1509-1523
A comparison of smartphone and infrasound microphone data from a fuel air explosive and a high explosive
For prompt detection of large (>1 kt) above-ground explosions, infrasound microphone networks and arrays are deployed at surveyed locations across the world. Denser regional and local networks are deployed for smaller explosions, however, they are limited in number and are often deployed temporarily for experiments. With the expanded interest in smaller yield explosions targeted at vulnerable areas such as population centers and key infrastructures, the need for more dense microphone networks has increased. An “attritable” (affordable, reusable, and replaceable) and flexible alternative can be provided by smartphone networks. Explosion signals from a fuel air explosive (thermobaric bomb) and a high explosive with trinitrotoluene equivalent yields of 6.35 and 3.63 kg, respectively, were captured on both an infrasound microphone and a network of smartphones. The resulting waveforms were compared in time, frequency, and time-frequency domains. The acoustic waveforms collected on smartphones produced a filtered explosion pulse due to the smartphone's diminishing frequency response at infrasound frequencies (<20 Hz) and was found difficult to be used with explosion characterization methods utilizing waveform features (peak overpressure, impulse, etc.). However, the similarities in time frequency representations and additional sensor inputs are promising for other explosion signal identification and analysis. As an example, a method utilizing the relative acoustic amplitudes for source localization using the smartphone sensor network is presented.
- 1 September 2024
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 156 (3) , 1509-1523
Open AccessA comparison of smartphone and infrasound microphone data from a fuel air explosive and a high explosive
For prompt detection of large (>1 kt) above-ground explosions, infrasound microphone networks and arrays are deployed at surveyed locations across the world. Denser regional and local networks are deployed for smaller explosions, however, they are limited in number and are often deployed temporarily for experiments. With the expanded interest in smaller yield explosions targeted at vulnerable areas such as population centers and key infrastructures, the need for more dense microphone networks has increased. An “attritable” (affordable, reusable, and replaceable) and flexible alternative can be provided by smartphone networks. Explosion signals from a fuel air explosive (thermobaric bomb) and a high explosive with trinitrotoluene equivalent yields of 6.35 and 3.63 kg, respectively, were captured on both an infrasound microphone and a network of smartphones. The resulting waveforms were compared in time, frequency, and time-frequency domains. The acoustic waveforms collected on smartphones produced a filtered explosion pulse due to the smartphone's diminishing frequency response at infrasound frequencies (<20 Hz) and was found difficult to be used with explosion characterization methods utilizing waveform features (peak overpressure, impulse, etc.). However, the similarities in time frequency representations and additional sensor inputs are promising for other explosion signal identification and analysis. As an example, a method utilizing the relative acoustic amplitudes for source localization using the smartphone sensor network is presented.
- Open Access
- 25 July 2024
- Published by MDPI AG in Preprints.org
Explosion Detection using Smartphones: Ensemble Learning with the Smartphone High-explosive Audio Recordings Dataset and the ESC-50 Dataset
Explosion monitoring is performed by infrasound and seismoacoustic sensor networks that are distributed globally, regionally, and locally. However, these networks are unevenly and sparsely distributed, especially in the local scale as maintaining and deploying networks is costly. With increasing interest in smaller yield explosions, the need for more dense networks has increased. To address this issue, we propose using smartphone sensors for explosion detection as they are cost-effective and easy to deploy. Although there are studies using smartphone sensors for explosion detection, the field is still in its infancy and new technologies need to be developed. We applied a machine learning model for explosion detection using smartphone microphones. The data used were from the Smartphone High-explosion Audio Recordings Dataset (SHAReD), a collection of 326 waveforms from 70 high-explosive (HE) events recorded on smartphones, and the ESC-50 dataset, a benchmarking dataset commonly used for environmental sound classification. Two machine learning models were trained and combined into an ensemble model for explosion detection. The resulting ensemble model classified audio signals as either “explosion,” “ambient,” or “other” with true positive rates (recall) greater than 96% for all three categories.
- 25 July 2024
- Published by MDPI AG in Preprints.org
Open AccessExplosion Detection using Smartphones: Ensemble Learning with the Smartphone High-explosive Audio Recordings Dataset and the ESC-50 Dataset
Explosion monitoring is performed by infrasound and seismoacoustic sensor networks that are distributed globally, regionally, and locally. However, these networks are unevenly and sparsely distributed, especially in the local scale as maintaining and deploying networks is costly. With increasing interest in smaller yield explosions, the need for more dense networks has increased. To address this issue, we propose using smartphone sensors for explosion detection as they are cost-effective and easy to deploy. Although there are studies using smartphone sensors for explosion detection, the field is still in its infancy and new technologies need to be developed. We applied a machine learning model for explosion detection using smartphone microphones. The data used were from the Smartphone High-explosion Audio Recordings Dataset (SHAReD), a collection of 326 waveforms from 70 high-explosive (HE) events recorded on smartphones, and the ESC-50 dataset, a benchmarking dataset commonly used for environmental sound classification. Two machine learning models were trained and combined into an ensemble model for explosion detection. The resulting ensemble model classified audio signals as either “explosion,” “ambient,” or “other” with true positive rates (recall) greater than 96% for all three categories.
- Open Access
- 29 April 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Passive high explosive neutron inspection (PHENIX): a new method to confirm the presence or absence of high explosives for nuclear treaty verification
Advanced instruments and methods need to be developed now to create a technical basis to support the negotiation of future nuclear arms control treaties. One new capability that is anticipated is the ability to confirm either the declared presence or declared absence of high explosive (HE) material in the presence of special nuclear material (SNM). Towards this goal, Passive HE Neutron Inspection (PHENIX) has been developed and demonstrated as a method for confirming the presence or absence of HE in the presence of plutonium. The method exploits the inherent presence of neutrons associated with the decay of plutonium as an internal probe source for performing prompt gamma-ray neutron activation analysis (PGNAA), searching for the presence of HE as revealed by the emission of characteristic gamma rays following neutron absorption in hydrogen and nitrogen which are building blocks of present-day, military-grade HE. Tests using stoichiometrically-correct hemishells of mock HE with plutonium show that a system can be expected to positively confirm the presence or absence of these signatures, supporting determination of HE presence or absence with Pu, in a few hours. To protect other potentially sensitive gamma-ray signatures from a treaty accountable item, an analog information barrier has been conceptualized and tested which physically prevents the collection of gamma-ray spectral data outside of user selected energy windows strategically chosen to view only narrow spectral regions corresponding to the hydrogen (2223.2 keV) and nitrogen (9807.2 keV, 10,318.2 keV, and 10,829.2 keV) PGNAA signatures.
- 29 April 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-8
Open AccessPassive high explosive neutron inspection (PHENIX): a new method to confirm the presence or absence of high explosives for nuclear treaty verification
Advanced instruments and methods need to be developed now to create a technical basis to support the negotiation of future nuclear arms control treaties. One new capability that is anticipated is the ability to confirm either the declared presence or declared absence of high explosive (HE) material in the presence of special nuclear material (SNM). Towards this goal, Passive HE Neutron Inspection (PHENIX) has been developed and demonstrated as a method for confirming the presence or absence of HE in the presence of plutonium. The method exploits the inherent presence of neutrons associated with the decay of plutonium as an internal probe source for performing prompt gamma-ray neutron activation analysis (PGNAA), searching for the presence of HE as revealed by the emission of characteristic gamma rays following neutron absorption in hydrogen and nitrogen which are building blocks of present-day, military-grade HE. Tests using stoichiometrically-correct hemishells of mock HE with plutonium show that a system can be expected to positively confirm the presence or absence of these signatures, supporting determination of HE presence or absence with Pu, in a few hours. To protect other potentially sensitive gamma-ray signatures from a treaty accountable item, an analog information barrier has been conceptualized and tested which physically prevents the collection of gamma-ray spectral data outside of user selected energy windows strategically chosen to view only narrow spectral regions corresponding to the hydrogen (2223.2 keV) and nitrogen (9807.2 keV, 10,318.2 keV, and 10,829.2 keV) PGNAA signatures.
- Open Access
- 20 February 2024
- Published by Office of Scientific and Technical Information (OSTI)
Comparative Analysis of Explosion Signals on Smartphones and Seismometers [Poster]
Seismoacoustic signatures from a chemical explosion was recorded on two seismometers and eight smartphone accelerometers at Idaho National Laboratory (INL). The captured waveform’s propagation and its time frequency representations are compared. The smartphone accelerometers were able to pick up a clear seismoacoustic explosion signal at within 1 km (150 m/kg1/3) and a noisy signal up to 5.3 km (790 m/kg1/3).
- 20 February 2024
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessComparative Analysis of Explosion Signals on Smartphones and Seismometers [Poster]
Seismoacoustic signatures from a chemical explosion was recorded on two seismometers and eight smartphone accelerometers at Idaho National Laboratory (INL). The captured waveform’s propagation and its time frequency representations are compared. The smartphone accelerometers were able to pick up a clear seismoacoustic explosion signal at within 1 km (150 m/kg1/3) and a noisy signal up to 5.3 km (790 m/kg1/3).
- Open Access
- 1 September 2023
- Published by Office of Scientific and Technical Information (OSTI)
Long-length Scintillating Fibers for Nuclear Waste Repository [Poster]
Containment verification in inaccessible radiological & nuclear waste repositories
- 1 September 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessLong-length Scintillating Fibers for Nuclear Waste Repository [Poster]
Containment verification in inaccessible radiological & nuclear waste repositories