Jaakko Paasonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jaakko Paasonen has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Olli Gröhn
A. I. Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
11 shared publications Raimo A. Salo
8 shared publicationsOlli Gröhn
AI Virtanen Institute for Molecular Sciences, University of Eastern Finland, Kuopio, Finland
7 shared publicationsHeikki Tanila
A. I. Virtanen Institute for Molecular Sciences, University of Eastern Finland , Neulaniementie 2, FI-70211, Kuopio
5 shared publications- Heikki Sinisalo
Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
4 shared publications - Juuso T. Korhonen
Department of Neuroscience and Biomedical Engineering, Aalto University School of Science, Espoo, Finland
4 shared publications
Latest Publications
- Open Access
- 6 May 2026
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
Mapping cardiac and respiratory pulsations simultaneously with functional connectivity in the rat brain using zero echo time fMRI
Vascular pulsations are increasingly recognized as key contributors to cerebral perfusion and brain clearance mechanisms, with alterations linked to aging and neurodegenerative diseases. However, capturing fast physiological dynamics in preclinical models remains technically challenging due to high cardiac frequencies and small brain size. Here, we investigated the feasibility of zero echo time (ZTE) functional MRI (fMRI) to capture cardiac- and respiration-related pulsations across multiple temporal scales in the rat brain under isoflurane anesthesia. We used retrospective binning to assess cardiac- and respiration-related pulsations. Cardiovascular state was modulated with medetomidine, and functional connectivity analyses were performed to evaluate slower neural dynamics. ZTE fMRI robustly detected physiological pulsations across the brain, achieving effective temporal resolution of 8 ms, with the strongest signals observed in large arteries, consistent with an inflow‑based contrast mechanism. Cardiac pulsation amplitudes increased significantly under combined medetomidine–isoflurane anesthesia, whereas respiration‑related pulsations remained stable. Functional connectivity decreased under combined anesthesia, confirming ZTE fMRI sensitivity to slower neural dynamics. ZTE fMRI enables simultaneous assessment of cerebrovascular pulsatility and functional connectivity, providing a powerful tool for studying physiological brain dynamics in vivo.
- 6 May 2026
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
Open AccessMapping cardiac and respiratory pulsations simultaneously with functional connectivity in the rat brain using zero echo time fMRI
Vascular pulsations are increasingly recognized as key contributors to cerebral perfusion and brain clearance mechanisms, with alterations linked to aging and neurodegenerative diseases. However, capturing fast physiological dynamics in preclinical models remains technically challenging due to high cardiac frequencies and small brain size. Here, we investigated the feasibility of zero echo time (ZTE) functional MRI (fMRI) to capture cardiac- and respiration-related pulsations across multiple temporal scales in the rat brain under isoflurane anesthesia. We used retrospective binning to assess cardiac- and respiration-related pulsations. Cardiovascular state was modulated with medetomidine, and functional connectivity analyses were performed to evaluate slower neural dynamics. ZTE fMRI robustly detected physiological pulsations across the brain, achieving effective temporal resolution of 8 ms, with the strongest signals observed in large arteries, consistent with an inflow‑based contrast mechanism. Cardiac pulsation amplitudes increased significantly under combined medetomidine–isoflurane anesthesia, whereas respiration‑related pulsations remained stable. Functional connectivity decreased under combined anesthesia, confirming ZTE fMRI sensitivity to slower neural dynamics. ZTE fMRI enables simultaneous assessment of cerebrovascular pulsatility and functional connectivity, providing a powerful tool for studying physiological brain dynamics in vivo.
- Open Access
- 6 January 2026
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 36 (1)
Secondary thalamic neuroinflammation associates with disturbed corticothalamic connectivity in a model of severe traumatic brain injury in male rats—a longitudinal study
Traumatic brain injury (TBI) is one of the leading causes of death and disability worldwide. The initial injury initiates a cascade of secondary injury mechanisms, including neuroinflammation and disruption of brain connectivity. In this study, we used the lateral fluid percussion injury model of TBI to investigate the relationship between secondary thalamic inflammation and corticothalamic connectivity disruptions. For this, we followed rats for six months post-injury, during which functional magnetic resonance imaging (fMRI) was conducted under light sedation, as well as diffusion tensor imaging (DTI) and positron emission tomography (PET). PET imaging with [18F]-FEPPA revealed neuroinflammation in the subacute stage in several ipsilateral thalamic nuclei, including the ventral posterior nucleus and lateral nucleus. In the fMRI analysis, we observed initial corticothalamic hypoconnectivity, which partially resolved by six months post-injury. DTI showed persistent increased mean, axial, and radial diffusivity in the ipsilateral thalamic nuclei from two months post-injury. Histological examination confirmed chronic thalamic neuroinflammation and neuronal loss eight months post-TBI. Correlation analyses showed that subacute thalamic neuroinflammation was associated with long-term structural and functional changes. These findings suggest that secondary thalamic inflammation contributes to enduring corticothalamic connectivity disruptions, which may underlie cognitive and sensorimotor deficits observed after TBI.
- 6 January 2026
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 36 (1)
Open AccessSecondary thalamic neuroinflammation associates with disturbed corticothalamic connectivity in a model of severe traumatic brain injury in male rats—a longitudinal study
Traumatic brain injury (TBI) is one of the leading causes of death and disability worldwide. The initial injury initiates a cascade of secondary injury mechanisms, including neuroinflammation and disruption of brain connectivity. In this study, we used the lateral fluid percussion injury model of TBI to investigate the relationship between secondary thalamic inflammation and corticothalamic connectivity disruptions. For this, we followed rats for six months post-injury, during which functional magnetic resonance imaging (fMRI) was conducted under light sedation, as well as diffusion tensor imaging (DTI) and positron emission tomography (PET). PET imaging with [18F]-FEPPA revealed neuroinflammation in the subacute stage in several ipsilateral thalamic nuclei, including the ventral posterior nucleus and lateral nucleus. In the fMRI analysis, we observed initial corticothalamic hypoconnectivity, which partially resolved by six months post-injury. DTI showed persistent increased mean, axial, and radial diffusivity in the ipsilateral thalamic nuclei from two months post-injury. Histological examination confirmed chronic thalamic neuroinflammation and neuronal loss eight months post-TBI. Correlation analyses showed that subacute thalamic neuroinflammation was associated with long-term structural and functional changes. These findings suggest that secondary thalamic inflammation contributes to enduring corticothalamic connectivity disruptions, which may underlie cognitive and sensorimotor deficits observed after TBI.
- Open Access
- 1 July 2025
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 35 (7)
Whisker pad stimulation with different frequencies reveals non-uniform modulation of functional MRI signal across sensory systems in awake rats
Primary sensory systems are traditionally considered separate units, but emerging evidence highlights notable interactions between them. Using a quiet and motion-tolerant zero-echo time functional magnetic resonance imaging technique, we examined brain-wide cross-sensory responses to whisker pad stimulation in awake and anesthetized rats. Our results indicate that whisker pad stimulation activated not only the whisker-mediated tactile system, but also auditory, visual, high-order, and cerebellar regions, demonstrating brain-wide cross-sensory and associative activity. Based on response characteristics, non-core regions responded to stimulation in a markedly different way compared to the primary sensory system, likely reflecting distinct encoding modes among primary sensory, cross-sensory, and integrative processing. Lastly, while low-order sensory activity was detectable under anesthesia, high-order processing and the complex differences between primary, cross-sensory, and associative systems were evident only in the awake state. This study reveals novel aspects of the cross-sensory interplay of the whisker-mediated tactile system and underscores the challenges of observing these phenomena in anesthetized rats.
- 1 July 2025
- Published by Oxford University Press (OUP) in Cerebral Cortex
- Vol. 35 (7)
Open AccessWhisker pad stimulation with different frequencies reveals non-uniform modulation of functional MRI signal across sensory systems in awake rats
Primary sensory systems are traditionally considered separate units, but emerging evidence highlights notable interactions between them. Using a quiet and motion-tolerant zero-echo time functional magnetic resonance imaging technique, we examined brain-wide cross-sensory responses to whisker pad stimulation in awake and anesthetized rats. Our results indicate that whisker pad stimulation activated not only the whisker-mediated tactile system, but also auditory, visual, high-order, and cerebellar regions, demonstrating brain-wide cross-sensory and associative activity. Based on response characteristics, non-core regions responded to stimulation in a markedly different way compared to the primary sensory system, likely reflecting distinct encoding modes among primary sensory, cross-sensory, and integrative processing. Lastly, while low-order sensory activity was detectable under anesthesia, high-order processing and the complex differences between primary, cross-sensory, and associative systems were evident only in the awake state. This study reveals novel aspects of the cross-sensory interplay of the whisker-mediated tactile system and underscores the challenges of observing these phenomena in anesthetized rats.
- Open Access
- 2 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Multi-coil TMS for preclinical applications in ultra-high-field MRI
Monitoring cortical responses to neuromodulation on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here, we report on a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, multi-coil transcranial magnetic stimulation (mTMS) is delivered with a 2-coil array, and the MRI signal is measured with a radiofrequency coil. The mTMS can change the stimulus orientation with 1° resolution in a millisecond. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. The mTMS system was successfully implemented and tested with the small-animal MRI, showing minimal interference with B0 and B1+ fields and uncompromised image quality. A delay of 40 ms between the stimulation pulse and fMRI acquisition—similar or even shorter than those previously described in humans—led to artifact-free images. Concurrent electronically targeted brain stimulation and neuroimaging provides a valuable tool for exploring whole-brain network functions, endorsing more efficient treatment protocols.
- 2 May 2025
- Published by MIT Press in Imaging Neuroscience
- Vol. 3
Open AccessMulti-coil TMS for preclinical applications in ultra-high-field MRI
Monitoring cortical responses to neuromodulation on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here, we report on a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, multi-coil transcranial magnetic stimulation (mTMS) is delivered with a 2-coil array, and the MRI signal is measured with a radiofrequency coil. The mTMS can change the stimulus orientation with 1° resolution in a millisecond. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. The mTMS system was successfully implemented and tested with the small-animal MRI, showing minimal interference with B0 and B1+ fields and uncompromised image quality. A delay of 40 ms between the stimulation pulse and fMRI acquisition—similar or even shorter than those previously described in humans—led to artifact-free images. Concurrent electronically targeted brain stimulation and neuroimaging provides a valuable tool for exploring whole-brain network functions, endorsing more efficient treatment protocols.
- Open Access
Whisker stimulation with different frequencies reveals non-uniform modulation of functional magnetic resonance imaging signal across sensory systems in awake rats
Primary sensory systems are classically considered to be separate units, however there is current evidence that there are notable interactions between them. We examined the cross-sensory interplay by applying a quiet and motion-tolerant zero echo time functional magnetic resonance imaging (fMRI) technique to elucidate the evoked brain-wide responses to whisker pad stimulation in awake and anesthetized rats. Specifically, characterized the brain-wide responses in core and non-core regions to whisker pad stimulation by the varying stimulation-frequency, and determined whether isoflurane-medetomidine anesthesia, traditionally used in preclinical imaging, confounded investigations related to sensory integration. We demonstrated that unilateral whisker pad stimulation not only elicited robust activity along the whisker-mediated tactile system, but also in auditory, visual, high-order, and cerebellar regions, indicative of brain-wide cross-sensory and associative activity. By inspecting the response profiles to different stimulation frequencies and temporal signal characteristics, we observed that the non-core regions responded to stimulation in a very different way compared to the primary sensory system, likely reflecting different encoding modes between the primary sensory, cross-sensory, and integrative processing. Lastly, while the activity evoked in low-order sensory structures could be reliably detected under anesthesia, the activity in high-order processing and the complex differences between primary, cross-sensory, and associative systems were visible only in the awake state. We conclude that our study reveals novel aspects of the cross-sensory interplay of whisker-mediated tactile system, and importantly, that these would be difficult to observe in anesthetized rats.
Open AccessWhisker stimulation with different frequencies reveals non-uniform modulation of functional magnetic resonance imaging signal across sensory systems in awake rats
Primary sensory systems are classically considered to be separate units, however there is current evidence that there are notable interactions between them. We examined the cross-sensory interplay by applying a quiet and motion-tolerant zero echo time functional magnetic resonance imaging (fMRI) technique to elucidate the evoked brain-wide responses to whisker pad stimulation in awake and anesthetized rats. Specifically, characterized the brain-wide responses in core and non-core regions to whisker pad stimulation by the varying stimulation-frequency, and determined whether isoflurane-medetomidine anesthesia, traditionally used in preclinical imaging, confounded investigations related to sensory integration. We demonstrated that unilateral whisker pad stimulation not only elicited robust activity along the whisker-mediated tactile system, but also in auditory, visual, high-order, and cerebellar regions, indicative of brain-wide cross-sensory and associative activity. By inspecting the response profiles to different stimulation frequencies and temporal signal characteristics, we observed that the non-core regions responded to stimulation in a very different way compared to the primary sensory system, likely reflecting different encoding modes between the primary sensory, cross-sensory, and integrative processing. Lastly, while the activity evoked in low-order sensory structures could be reliably detected under anesthesia, the activity in high-order processing and the complex differences between primary, cross-sensory, and associative systems were visible only in the awake state. We conclude that our study reveals novel aspects of the cross-sensory interplay of whisker-mediated tactile system, and importantly, that these would be difficult to observe in anesthetized rats.
- Open Access
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Modeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.
- 14 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (17) , 175001
Open AccessModeling the stress and forces on multi-channel TMS coil arrays in high-field MRI scanners
Transcranial magnetic stimulation (TMS) is a non-invasive method for stimulating the cortex. Concurrent functional magnetic resonance imaging can show changes in TMS-induced activity in the whole brain, with the potential to inform brain function research and to guide the development of TMS therapy. However, the interaction of the strong current pulses in the TMS coil in the static main magnetic field of the MRI produces high Lorentz forces, which may damage the coil enclosure and compromise the patient’s safety. We studied the time-dependent mechanical behavior and durability of two multi-locus TMS (mTMS) coil arrays inside a high-field MRI bore with finite element modeling. In addition, coil arrays were built and tested based on the simulation results. We found that the current pulses produce shock waves and time-dependent stress distribution in the coil plates. The intensity and location of the maximum stress depend on the current waveform, the coil combination, and the transducer orientation relative to the MRI magnetic field. We found that 30% glass-fiber-filled polyamide is the most durable material out of the six options studied. In addition, novel insights for more durable TMS coil designs were obtained. Our study contributes to a comprehensive understanding of the underlying mechanisms responsible for the structural failure of mTMS coil arrays during stimulation within high static magnetic fields. This knowledge is essential for developing mechanically stable and safe mTMS-MRI transducers.
- Open Access
A multi-channel TMS system enabling accurate stimulus orientation control during concurrent ultra-high-field MRI for preclinical applications
Monitoring cortical responses to neuromodulation protocols on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here we report a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, transcranial magnetic stimulation is delivered with a set of two coils and the MRI signals are recorded with a radiofrequency coil. The coil set provides millisecond-scale electronic control of the stimulus orientation with 1° resolution. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. We show that the stimulation pulses do not affect the anatomical imaging quality, and imaging signals are disrupted only if recorded before 10 ms after pulse delivery. Concurrent electronically targeted brain stimulation and neuroimaging sets the stage for the causal investigation of whole-brain network functions, endorsing more efficient treatment protocols.
Open AccessA multi-channel TMS system enabling accurate stimulus orientation control during concurrent ultra-high-field MRI for preclinical applications
Monitoring cortical responses to neuromodulation protocols on preclinical models can elucidate fundamental mechanisms of brain function. Concurrent brain stimulation and imaging is challenging, usually compromising spatiotemporal resolution, accuracy, and versatility. Here we report a non-invasive brain stimulation system with electronic control of neuromodulation parameters in a 9.4-T magnetic resonance imaging (MRI) environment. In the imaging scanner, transcranial magnetic stimulation is delivered with a set of two coils and the MRI signals are recorded with a radiofrequency coil. The coil set provides millisecond-scale electronic control of the stimulus orientation with 1° resolution. Without physically rotating the coils, we evoked orientation-specific muscle responses after cortical stimulation on an anesthetized rat. We show that the stimulation pulses do not affect the anatomical imaging quality, and imaging signals are disrupted only if recorded before 10 ms after pulse delivery. Concurrent electronically targeted brain stimulation and neuroimaging sets the stage for the causal investigation of whole-brain network functions, endorsing more efficient treatment protocols.
- Open Access
- 1 November 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (6) , 1606
The impulse noise of TMS inside a 3 T and 9.4 T MRI
- 1 November 2021
- Published by Elsevier in Brain Stimulation
- Vol. 14 (6) , 1606
Open AccessThe impulse noise of TMS inside a 3 T and 9.4 T MRI
- Open Access
Spatial signatures of anesthesia-induced burst-suppression differ between primates and rodents
During deep anesthesia, the electroencephalographic (EEG) signal of the brain alternates between bursts of activity and periods of relative silence (suppressions). The origin of burst-suppression and its distribution across the brain remain matters of debate. In this work, we used functional magnetic resonance imaging (fMRI) to map the brain areas involved in anesthesia-induced burst-suppression across four mammalian species: humans, long-tailed macaques, common marmosets, and rats. At first, we determined the fMRI signatures of burst-suppression in human EEG-fMRI data. Applying this method to animal fMRI datasets, we found distinct burst-suppression signatures in all species. The burst-suppression maps revealed a marked inter-species difference: in rats the entire neocortex engaged in burst-suppression, while in primates most sensory areas were excluded—predominantly the primary visual cortex. We anticipate that the identified species-specific fMRI signatures and whole-brain maps will guide future targeted studies investigating the cellular and molecular mechanisms of burst-suppression in unconscious states.
Open AccessSpatial signatures of anesthesia-induced burst-suppression differ between primates and rodents
During deep anesthesia, the electroencephalographic (EEG) signal of the brain alternates between bursts of activity and periods of relative silence (suppressions). The origin of burst-suppression and its distribution across the brain remain matters of debate. In this work, we used functional magnetic resonance imaging (fMRI) to map the brain areas involved in anesthesia-induced burst-suppression across four mammalian species: humans, long-tailed macaques, common marmosets, and rats. At first, we determined the fMRI signatures of burst-suppression in human EEG-fMRI data. Applying this method to animal fMRI datasets, we found distinct burst-suppression signatures in all species. The burst-suppression maps revealed a marked inter-species difference: in rats the entire neocortex engaged in burst-suppression, while in primates most sensory areas were excluded—predominantly the primary visual cortex. We anticipate that the identified species-specific fMRI signatures and whole-brain maps will guide future targeted studies investigating the cellular and molecular mechanisms of burst-suppression in unconscious states.
- Open Access
- 1 February 2020
- Published by Elsevier in NeuroImage
- Vol. 206, 116338
Multi-band SWIFT enables quiet and artefact-free EEG-fMRI and awake fMRI studies in rat
- 1 February 2020
- Published by Elsevier in NeuroImage
- Vol. 206, 116338
Open AccessMulti-band SWIFT enables quiet and artefact-free EEG-fMRI and awake fMRI studies in rat