XYXiaodong Yang

Xiaodong Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Xiaodong Yang has a total of 51 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Mitad thermal load: quantifying a culturally non-negotiable internal heat gain overlooked by building performance simulation in Global South housing

    by Tilaye Sitotaw Akale, Jiayu Zhang, Xiaodong Yang

    Building performance simulation inherits internal heat gain schedules from datasets assembled almost entirely in North American and European housing. Global South housing departs from those antecedents, so inherited schedules can misstate the dwellings they describe. This paper quantifies one such load: the Mitad, the electric injera cooker used in most Ethiopian households. Evidence comes from 48 households in Addis Ababa condominium housing: 3,584 diary entries, 20 key-informant interviews, four focus groups, and a four-stage EnergyPlus calibration against ASHRAE Guideline 14. The Mitad dissipates 2,000 W into kitchens of roughly 20 m³ in 83.3% of households for a mean of 72 minutes each evening. Under security-constrained ventilation, calibrated models place the kitchen 5.8 °C above the living room during operation and 2.4 °C an hour later, and evenings with baking are 0.41 points warmer than baking-free evenings within the same household (p < .001, d = 0.68). Incorporating the load as a zone-level scheduled gain cut mean bias error from -30.0% to -7.5% and the coefficient of variation of the root-mean-square error from 31% to 24%, within Guideline 14 limits. Because injera preparation is culturally non-negotiable, the findings support ventilation-first design and a five-step protocol for other culturally embedded cooking loads.

  • Open Access

    The Security-Thermal Comfort Paradox: Quantifying the Hidden Night-Ventilation Performance Gap in Tropical-Highland Public Housing

    by Tilaye Sitotaw Akale, Jiayu Zhang, Xiaodong Yang

    Passive retrofit strategies for public housing in the Global South consistently underperform their simulated potential because conventional building energy models treat occupant behaviour as fixed rather than as a stochastic, culturally embedded variable. This study develops and empirically validates the Predictive Socio-Technical Modeling Framework, linking technical and stochastic behavioural subsystems to thermal resilience and comfort outcomes through a validated mediating construct, the Integration and Adoption Procedure, with an institutional subsystem as moderator. The framework tested across two condominium typologies across Bole, Yeka, Nifas Silk-Lafto, and Kolfe Keranio sub-cities in Addis Ababa, Ethiopia, sampling 60 households (48 retained after a 25% buffer), yielding N = 3,584 valid longitudinal diary entries (77.7% response rate). Diary data were converted into time-of-day-stratified Bernoulli occupancy schedules in EnergyPlus, calibrated to ASHRAE Guideline 14 (MBE within ±4.2%; CV(RMSE) within 21.3%). The central empirical finding is a Security-Thermal Comfort Paradox: driven by crime-prevention norms rather than thermal preference, night-time window opening occurred at 0.12 [0.08, 0.16], compared with the 52% standard default, thereby erasing 40–60% of achievable night-ventilation cooling potential. Behaviour-informed retrofit simulation reduced annual overheating hours by 22–34% relative to baseline, with security-compatible ventilation the best-performing strategy (IAP = 4.1/5). Multilevel modelling supported all five pathways, including significant IAP mediation (indirect β = 0.31, p = 0.012) and institutional moderation (ΔR² = 0.09, p = 0.034). The PSTM Framework provides the first empirically validated instrument linking socio-technical integration quality to passive retrofit performance, with structural features suggesting transferability to comparable security-constrained tropical-highland contexts, pending local calibration.

  • Open Access

    Quantifying the Security-Closure Thermal Penalty:,A Behaviour-Informed Calibration Framework for,Building Performance Simulation in Security-Constrained Housing

    by Tilaye Sitotaw Akale, Jiayu Zhang, Xiaodong Yang

    Standard building performance simulation tools, including EnergyPlus, use ASHRAE 90.1 residential occupancy schedules that assume nighttime window-opening rates of 50–60%. These rates were measured in low-security, temperate Western housing and have never been validated for urban public housing in Sub-Saharan Africa. In security-constrained multi-story housing, where documented nighttime security risks make window closure a near-universal behavior, this assumption generates a large, systematic, and uncorrected simulation error that distorts every retrofit investment informed by it. This study defines, quantifies, and corrects the Security-Closure Thermal Penalty: the systematic overestimation of the cooling benefit from natural ventilation when applying security-neutral occupancy schedules to security-constrained residential buildings. Security-Closure Thermal Penalty is the hot-climate, Global South counterpart of the European prebound effect. Where income constraints suppress heating below cold-climate model predictions, security constraints suppress ventilation below hot-climate model predictions. No prior study has named, measured, or provided a validated correction instrument for this error class. A Longitudinal Structured Digital Diary protocol was deployed in n=48 stratified households within Addis Ababa’s Condominium Housing Program (CHP), yielding N=2,688 twice-daily observations across hot (March–April 2024) and cool (July–August 2024) seasons. Households were stratified by typology (G+4; G+10), façade orientation (N/S/E/W), and floor level (low/mid/high). EnergyPlus v9.6 models were calibrated through a validated four-stage protocol; at Stage 3, ASHRAE default schedules were replaced with LSDD-derived probabilistic window-operation inputs formatted directly for EnergyPlus IDF integration. Multilevel modelling (MLM; n=2,688 observations; n=48 households; 5,000 bootstrap replications) and the novel Thermal Trap Index, the proportion of diary entries in which TSV ≥+2 and no adaptive action was available, completed the analytical framework. Observed night-time window opening rates were 8–12% (95% CI: 7–13%), against the 50–60% ASHRAE default, a 44 percentage-point structural divergence that was statistically identical across both seasons (χ² (1) =1.8, p=0.18). This divergence results in a mean peak indoor temperature penalty of 1.8–2.6°C and a 25–38% overestimation of the ventilation cooling benefit in the standard simulation. Security behaviour explains 41% of the variance between predicted and observed thermal outcomes (95% CI: 37–45%). Replacing the ASHRAE default schedule with LSDD-derived inputs reduced Mean Bias Error from -32% (SD=4.2%) to -7.8%, a 24.2 percentage-point improvement that meets ASHRAE Guideline 14 accuracy thresholds achieved through schedule correction alone, with no changes to physical building parameters. The Thermal Trap Index revealed a structural equity gradient: the lowest-control households had TTI=0.41, meaning 41% of their discomfort hours lacked an available adaptive response, a threefold burden relative to the highest-control group (TTI=0.14). Security context is not a qualitative annotation to BPS workflows; it is a mandatory boundary condition. The LSDD protocol operable at USD 0–15/month via standard SMS infrastructure and producing outputs directly compatible with EnergyPlus IDF files provides a generalizable, low-cost calibration pathway for data-scarce urban environments. A documented three

  • Open Access

    A Predictive Socio-Technical Modelling Framework for Occupant-Informed Passive Retrofitting: Integrating Stochastic Behaviour Tracking, EnergyPlus Simulation, and Multilevel Modelling

    by Tilaye Sitotaw Akale, Jiayu Zhang, Xiaodong Yang

    Building retrofit research relies on deterministic models treating occupant behaviour as fixed, an assumption failing in practice. In the Global South, rapid urbanisation creates millions of climate-insensitive housing units, yielding persistent gaps between predicted and actual performance. No validated framework yet combines Socio-Technical Systems theory, stochastic occupant behaviour data, and calibrated simulation into a testable causal model for tropical-highland climates. This study mathematically operationalises STS theory as a predictive engineering instrument beyond descriptive sociology via the novel Integration and Adoption Procedure (IAP) index, validated through two-level Multilevel Modelling with bootstrapped mediation in Global South public housing. A sequential mixed-methods design targeted two Addis Ababa condominium typologies (G+4, G+10). Components were: (1) ASHRAE Guideline 14-calibrated EnergyPlus simulation with behaviour-informed dynamic occupancy; (2) Longitudinal Stochastic Occupant Behavior Tracking protocol (n=36 households, two seasons, twice-daily ASHRAE seven-point reports) converting empirical frequencies to probabilistic inputs; (3) two-level MLM with bootstrapped mediation (5,000 replications, 95% CI), interaction moderation, and IAP as mediator (power>0.85; Cohen’s f²=0.15; ICC=0.21; α=0.05)., Behaviour-informed passive retrofits cut overheating by 22–34% and peak temperatures by 3.8°C versus baseline (487–521 hours/year). IAP correlated with Thermal Resilience (β=0.62, p<0.001) and Perceived Comfort (β=0.58, p<0.001), proving socio-technical integration drives outcomes beyond technical performance. Security-constrained night window closure (p=0.12) eliminated 40–60% of natural ventilation potential, quantifying the behavioural contribution to the tropical-highland performance gap. The Predictive Socio-Technical Modelling Framework scales to rapidly urbanising Global South cities (Nairobi, Dhaka, Lagos, Kampala, Bogotá) where stochastic behaviour, institutional constraints, and climate sensitivity converge on performance gaps.

  • Open Access

    Experimental Investigation on Combustion Characteristics of Massage Chairs in Waiting Halls of High-Speed Railway Stations

    by Xiaodong Yang, Wenbin Wei, Yujia Chen, Jiaming Zhao, Yanlong Li, Cheng Zhang, Saiya Feng

    In order to provide fire-scene parameters for fire protection design and data support for fire safety management of waiting halls in high-speed railway stations, this study systematically investigated the combustion characteristics of single, two, and three massage chairs using an industrial calorimeter. The results showed the following: The change in heat release rate in the growth stage of the massage chairs’ combustion tests was consistent with the t2 fast fire (with a growth coefficient of 0.04689). The maximum HRR was 1.2 MW for the single-massage-chair combustion test, 2.5 MW for the two-massage-chairs combustion test, and 3.5 MW for the three-massage-chairs combustion test. In the full-scale massage chairs combustion test, setting a 6.0 m fire isolation zone could effectively serve the functions of fire prevention and heat insulation. Considering a certain safety margin, and with a safety factor of 1.5 adopted, it is recommended that a fire isolation zone with a width of 9.0 m be used in the waiting halls of high-speed railway stations, which provides a direct, actionable design basis for engineering practice.


  • Coordination of interests in the government-led urban regeneration fund in China: an evolutionary game perspective

    by Chenying Liu, Xiaodong Yang, Jiayu Zhang

    Purpose: As an innovative cooperation mode, the government-led urban regeneration fund has stimulated the guiding role of financial resources in China’s urbanization process. However, the differences in roles and objectives have led to conflicts of interests and decision-making contradictions, which affect the efficiency and sustainability of the fund. This study aims to examine critical factors necessary for the interest coordination. Design/methodology/approach: Considering the interest relationship between local governments and fund managers, an evolutionary game model is established to examine their strategy selection in the urban regeneration fund. Four scenarios of equilibriums and corresponding evolutionarily stable strategies are analyzed. A case study is further conducted to simulate and analyze the evolutionary process and critical parameters of interest coordination. Findings: The results illustrate that local governments can effectively guide the fund managers by management measures. Significantly, it is unsustainable to constantly relying on the government external support like a blood transfusion in the long term. A market-oriented operational model should be established for interest coordination, including the full-process dynamic regulation, improved income distribution mechanism and performance appraisal. Originality/value: A dynamic strategy selection model and a case simulation analysis framework are developed to explore interest relationships in the urban regeneration fund. It is a novel attempt to introduce the fund manager, a specific stakeholder in financing process, into urban regeneration. Under the background of existing stock construction, this paper serves as a reference for governments in urban regeneration financing decisions, fund structure design and sustainable development.

  • Risk coupling analysis of causal factors in construction fall-from-height accidents

    by Hongying Niu, Xiaodong Yang, Jiayu Zhang, Shengyu Guo

    Purpose: Construction fall-from-height accidents are not only caused by a single factor but also by the risk coupling between two or more factors. The purpose of this paper is to quantitatively analyze the risk coupling relationships between multiple factors and identify critical factors in construction fall-from-height accidents. Design/methodology/approach: A cause analysis framework was established from the perspective of human, machine, material, management and environmental factors. The definition, the classification and the process of risk coupling were proposed. The data from 824 historical accident reports from 2011 to 2021 were collected on government websites. A risk coupling analysis model was constructed to quantitatively analyze the risk coupling relationships of multiple factors based on the N-K model. The results were classified using K-means clustering analysis. Findings: The results indicated that the greater the number of causal factors involved in risk coupling, the higher the risk coupling value and the higher the risk of accidents. However, specific risk coupling combinations occurred when the number of their coupling factors was not large. Human, machine and material factors were determined to be the critical factors when risk coupling between them tended to pose a greater risk of accidents. Originality/value: This study established a cause analysis framework from five aspects and constructed a theoretical model to quantitatively analyze multi-factor coupling. Several suggestions were proposed for construction units to manage accident risks more effectively by controlling the number of factors and paying more attention to critical factors coupling and management and environmental factors.


  • Open Access

    Guidance experiments on residents’ participation in decision-making activities related to urban settlement regeneration in China

    by Jiayu Zhang, Xiaodong Yang, Manman Xia, Dagang Lu

    In China, how to guide residents on actively participating in decision-making activities related to urban settlement regeneration is critical and must be addressed. Referring to the theory of planned behavior (TPB), combined with the characteristics of regeneration decision-making, the external environmental factors affecting residents’ participation in such decision-making activities, through impacting psychological environmental factors, were determined by establishing the structural equation model (SEM) and conducting a survey. The guidance measures of enhancing external pressure and providing regeneration information were selected. Participation guidance experiments were designed, and the typical communities located in the development zone and city center of Harbin, China were selected as the experiment regions. Forty-eight subjects were screened in each experimental region and divided into six groups; three participated in the experiments regarding the leading role of representatives, enhancing communication, and incentives, and three in the experiments on policy advocacy, regeneration technology popularization, and regeneration case sharing. Guidance measures’ effects for introversion or extraversion, regardless of region are, from large to small, incentives, regeneration case sharing, leading role of representatives, enhancing communication, policy advocacy and regeneration technology popularization. There are significant differences in the effects of enhancing external pressure measures between different personalities, and enhancing external pressure measures are more effective for extraversion. Although the differences in the effects of providing regeneration information measures are statistically insignificant, providing such measures is more effective for introversion. The results reflect the analysis of the influencing factors. TPB application is enriched and the guidance experiments used to verify guiding measures’ effectiveness are provided. Practically-significant implications include: communities and proprietor committees should organize neighborhood-relationship to enhance community activities, with the proprietor committee solving residents’ daily problems to win authority and trust, positively guiding residents’ participation. Community staff can also understand, via daily participation, residents’ personality traits, so as to implement the above-mentioned guidance measures.


  • Evaluation of smart community resilience: empirical evidence from Heilongjiang province, China

    by Shuyi Niu, Shuyi Niu, Xiaodong Yang, Xiaodong Yang, Huili Li, Huili Li, Jiayu Zhang, Jiayu Zhang