AVArturo Vargas-Olivares

Arturo Vargas-Olivares

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Arturo Vargas-Olivares has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Role: Role-Oriented Learning Environment

    by Donovan M. Esqueda-Merino, Diego Mondragon-Ugarte, Arturo Vargas-Olivares, J. Enrique Chong-Quero, Jose A. Herrera-Corral

    Higher Education is constantly adapting to the needs of their stakeholders, which has led through time into the use of strategies such as Problem-Based Learning (PBL), Project-Oriented Learning (POL) and Research-Based Learning (RBL). These strategies have been widely used as they let students move from the theory they learn in class, into practical examples that make sense to students in relation to their future professional activity. Yet, educational centers keep on adapting and adopting more strategies that promote the development of competences among students. This is due to the need of employers to have professionals having the required skill sets to overcome the challenges of a volatile, uncertain, complex and ambiguous environment. Thus, skillsets must not be limited to applying the knowledge they have, but also into giving them the tools to explore and understand alternatives outside their academic situations, by combining convergent and divergent thinking in a context that places them into the real-life situations they will be experiencing at work. Through this paper, we propose a methodology to adapt industrial needs into role-oriented learning.


  • Open Access

    Image Segmentation for the Treatment Planning of Magnetic Resonance-Guided High-Intensity Focused Ultrasound (MRgHIFU) Therapy: A Parametric Study

    by Arturo Vargas-Olivares, Octavio Navarro-Hinojosa, Samuel Pichardo, Laura Curiel, Moisés Alencastre-Miranda, Jesús Enrique Chong-Quero

    In the present research work, image segmentation methods were studied to find internal parameters that provide an efficient identification of the regions of interest in Magnetic Resonance (MR) images used for the therapy planning of High-Intensity Focused Ultrasound (HIFU), a minimally invasive therapeutic method used for selective ablation of tissue. The involved image segmentation methods were threshold, level set and watershed segmentation algorithm with markers (WSAM), and they were applied to transverse and sagittal MR images obtained from an experimental setup of a murine experiment. A parametric study, involving segmentation tests with different values for the internal parameters, was carried out. The F-measure results from the parametric study were analyzed by region using Welch’s ANOVA followed by post hoc Games-Howell test to determine the most appropriate method for region identification. In transverse images, the threshold method had the best performance for the air region with a F-measure median of 0.9802 (0.9743–0.9847, interquartile range IQR 0.0104), the WSAM for the tissue, gel-pad, transducer and water region with a F-measure median of 0.9224 (0.8718–0.9468, IQR 0.075), 0.9553 (0.9496–0.9606, IQR 0.011), 0.9416 (0.9330–0.9540, IQR 0.021) and 0.9769 (0.9741–0.9803, IQR 0.0062), respectively. In sagittal images, threshold method had the best performance for the air region with a F-measure median of 0.9680 (0.9589–0.9735, IQR 0.0146), the WSAM for the tissue and gel-pad regions with a F-measure median of 0.9241 (0.8870–0.9426, IQR 0.0556) and 0.9553 (0.9472–0.9625, IQR 0.0153), respectively, and the Geodesic Active Contours (GAC) method for the transducer and water regions with a F-measure median of 0.9323 (0.9221–0.9402, IQR 0.0181) and 0.9681 (0.9627–0.9715, IQR 0.0088), respectively. The present research work integrates preliminary results to generate more efficient procedures of image segmentation for treatment planning of the MRgHIFU therapy. Future work will address the search of an automatic segmentation process, regardless of the experimental setup.


  • Open Access

    Segmentation Method for Magnetic Resonance-Guided High-Intensity Focused Ultrasound Therapy Planning

    by A. Vargas-Olivares, O. Navarro-Hinojosa, M. Maqueo-Vicencio, L. Curiel, M. Alencastre-Miranda, J. E. Chong-Quero

    High-intensity focused ultrasound (HIFU) is a minimally invasive therapy modality in which ultrasound beams are concentrated at a focal region, producing a rise of temperature and selective ablation within the focal volume and leaving surrounding tissues intact. HIFU has been proposed for the safe ablation of both malignant and benign tissues and as an agent for drug delivery. Magnetic resonance imaging (MRI) has been proposed as guidance and monitoring method for the therapy. The identification of regions of interest is a crucial procedure in HIFU therapy planning. This procedure is performed in the MR images. The purpose of the present research work is to implement a time-efficient and functional segmentation scheme, based on the watershed segmentation algorithm, for the MR images used for the HIFU therapy planning. The achievement of a segmentation process with functional results is feasible, but preliminary image processing steps are required in order to define the markers for the segmentation algorithm. Moreover, the segmentation scheme is applied in parallel to an MR image data set through the use of a thread pool, achieving a near real-time execution and making a contribution to solve the time-consuming problem of the HIFU therapy planning.


  • Quantitative evaluation method of image segmentation techniques for Magnetic Resonance guided High Intensity Focused Ultrasound therapy

    by V. Rincon-Montes, A. Vargas-Olivares, S. Pichardo, L. Curiel, J. E. Chong-Quero

    This paper describes a quantitative evaluation method for the accuracy of two different segmentation techniques for the treatment planning of Magnetic Resonance guided High Intensity Focused Ultrasound (MRgHIFU). The first technique is a combination of image segmentation methods consisting of Otsu's method, global, edge detection with Laplacian of Gaussian method, region growing algorithm and variable thresholding method. The second technique is a combination of image segmentation methods consisting of Otsu's method and the selection of regions using variable thresholding. These methods were used to classify the pixels of real Magnetic Resonance (MR) images obtained for the study of the distribution of heat in abscess treatment in a murine model with High-Intensity Focused Ultrasound (HIFU). In the evaluation, a total of nine surveys of 48 images each were used, and a methodology including three main steps was followed: establishment of ground truth images and calculation of areas from the segmented images, discrepancy measure calculation, and data normalization. For the evaluation an area-based metric was used and it was based on a discrepancy measure proposed for two regions and on the generalized version for c regions. After the evaluation of both segmentation techniques it was found that they presented a better performance in axial MR images than in sagittal MR images. In sagittal MR images, the average error and standard deviation error measures indicated a high variability in the segmentation for both techniques. Due to the performance of the segmentation for sagittal images, improvements will be implemented taking into account the combination of the evaluated methods in order to exploit the benefits of each one.

  • Use of a variable thresholding-based image segmentation technique for magnetic resonance guided High Intensity Focused Ultrasound therapy: An in vivo validation

    by A. Vargas-Olivares, V. Rincon-Montes, S. Pichardo, L. Curiel, F. J. Ortiz-Cerecedo, J. E. Chong-Quero

    In this paper, the implementation of a segmentation technique based on Otsu's method, region growing algorithm and selection of regions using global and variable thresholding for the treatment planning of Magnetic Resonance guided High Intensity Focused Ultrasound (MRgHIFU) is described. The method is used to classify the pixels of real Magnetic Resonance (MR) images obtained for the study of the distribution of heat in abscess treatment in a murine model with High-Intensity Focused Ultrasound (HIFU). Using a discrepancy measure for evaluation, the proposed technique (segmentation technique I) demonstrated to be more efficient than an approach technique (segmentation technique II) based on Otsu's method, global thresholding, edge detection and region growing algorithm. In the evaluation, a total of nine surveys of 48 images each were used. For axial images the performance of segmentation technique I and the performance of segmentation technique II is very similar, having an average value of 92.05% for the former and an average value of 91.45% for the latter. On the other hand, for sagittal images, segmentation technique I presented an average performance of 85.46% while segmentation technique II presented an average performance of 69.01%.