Yong-Jin Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yong-Jin Kim has a total of 69 co-authors. Here are the top co-authors by number of shared publications:
- Hak-Joon Kim
Eco-Friendly Energy & Environment Research Division, Korea Institute of Machinery and Materials, Daejeon, South Korea
20 shared publications - Bangwoo Han
Eco-Friendly Energy & Environment Research Division, Korea Institute of Machinery and Materials, Daejeon, South Korea
19 shared publications - Yeawan Lee
Department of Sustainable Environment Research, Korea Institute of Machinery and Materials, Daejeon, South Korea
11 shared publications Ye-Sle Kim
Department of Sustainable Environment, Korea Institute of Machinery and Materials, Daejeon, South Korea
6 shared publicationsBangwoo Han
4 shared publicationsHaneol Lee
Department of Sustainable Environment, Korea Institute of Machinery and Materials, Daejeon, South Korea
4 shared publications
Latest Publications
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 677-683
On-Site Test on Fine Dust Reduction in Subway Station Using Electrostatic Type Air Purifier
This study investigates the effect of an electrostatic-type air handling unit (ES-AHU) for improving indoor air quality at subway station. The ES-AHU features a pre-charger with carbon microfiber electrodes and a non- metallic collecting plate. It achieved particulate matter collection efficiency exceeding 90% for both PM2.5 and PM10. This performance is approximately 1.3 to 1.5 times higher than those of conventional filter-based air handling unit. In addition, the ES-AHU reduced PM2.5 concentration in the waiting room area and platform decreased by over 50%. The results of the spatial distribution analysis showed that the PM2.5 concentration in the waiting room varies depending on the location, suggesting that it is important to consider the spatial characteristics for effective air quality improvement. The ES- AHU applied in this study shows the potential to enhance air quality and promote a healthier environment for passengers by improving the existing ventilation system at subway stations.
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 677-683
On-Site Test on Fine Dust Reduction in Subway Station Using Electrostatic Type Air Purifier
This study investigates the effect of an electrostatic-type air handling unit (ES-AHU) for improving indoor air quality at subway station. The ES-AHU features a pre-charger with carbon microfiber electrodes and a non- metallic collecting plate. It achieved particulate matter collection efficiency exceeding 90% for both PM2.5 and PM10. This performance is approximately 1.3 to 1.5 times higher than those of conventional filter-based air handling unit. In addition, the ES-AHU reduced PM2.5 concentration in the waiting room area and platform decreased by over 50%. The results of the spatial distribution analysis showed that the PM2.5 concentration in the waiting room varies depending on the location, suggesting that it is important to consider the spatial characteristics for effective air quality improvement. The ES- AHU applied in this study shows the potential to enhance air quality and promote a healthier environment for passengers by improving the existing ventilation system at subway stations.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 8194-8200
Removal of Ammonium and Fluoride From Industrial Wastewater by Sonoelectrochemical Precipitation
Wastewater from the semiconductor industry typically contains substantial amounts of total ammonia nitrogen (TAN) and fluoride that can have adverse effects on the environment. The present study examined the efficacy of a sonoelectrochemical system which applies ultrasonic waves to an electrochemical process in removing these species from wastewater. Application of the sonoelectrochemical process with a current of 2 A, and a sonication frequency of 40 kHz to synthetic wastewater resulted in a TAN removal efficiency of 52.2% . pH was the main factor affecting TAN crystallization, with alkaline conditions in combination with a sonication frequency of 40 kHz being optimal for TAN removal. In terms of fluoride removal, application of the sonoelectrochemical process for 1.5 h achieved a removal efficiency of 98% at pH 7. The main precipitates obtained were Al-F complexes. The present findings indicate that the sonoelectrochemical process is a feasible and cost-effective approach for use in the recycling of industrial wastewater.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 8194-8200
Removal of Ammonium and Fluoride From Industrial Wastewater by Sonoelectrochemical Precipitation
Wastewater from the semiconductor industry typically contains substantial amounts of total ammonia nitrogen (TAN) and fluoride that can have adverse effects on the environment. The present study examined the efficacy of a sonoelectrochemical system which applies ultrasonic waves to an electrochemical process in removing these species from wastewater. Application of the sonoelectrochemical process with a current of 2 A, and a sonication frequency of 40 kHz to synthetic wastewater resulted in a TAN removal efficiency of 52.2% . pH was the main factor affecting TAN crystallization, with alkaline conditions in combination with a sonication frequency of 40 kHz being optimal for TAN removal. In terms of fluoride removal, application of the sonoelectrochemical process for 1.5 h achieved a removal efficiency of 98% at pH 7. The main precipitates obtained were Al-F complexes. The present findings indicate that the sonoelectrochemical process is a feasible and cost-effective approach for use in the recycling of industrial wastewater.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5649-5654
Evaluation of Antiviral Electrostatic Precipitator With Commercially Antiviral Films Coated on Collection Plates Against Aerosolized Viruses
The presence of particulate matter (PM), which may contain airborne pathogens, raises significant concerns because of its ability to facilitate the transmission of diseases through aerosols. In this study, we developed an antiviral electrostatic precipitator (ESP) with commercially available antiviral films. We applied antiviral surfaces on ESP collection plates and demonstrated that it was effective to remove and inactivate aerosolized viruses in a two-stage ESP. For practical applicability and versatility in indoor air management, the near-zero ozone generation system was applied on the ESP, and four types of viruses, namely MS2 bacteriophage, H1N1, HCoV-229E and -OC43, were selected as suitable surrogates for human and animal respiratory viruses such as SARS-CoV-2. After collection of aerosolized viruses on antiviral surfaces for 30 min, the survivability of the collected viruses was remarkably decreased. We are confident that the findings of this study will demonstrate the viability of ESPs as a promising indoor/private air pollution control technology, boasting exceptional bioaerosol removal and inactivation efficiency. In addition, we aspire for our research to contribute significantly to the prevention of future outbreaks such as COVID-19 by providing a solid foundation for effective measures.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5649-5654
Evaluation of Antiviral Electrostatic Precipitator With Commercially Antiviral Films Coated on Collection Plates Against Aerosolized Viruses
The presence of particulate matter (PM), which may contain airborne pathogens, raises significant concerns because of its ability to facilitate the transmission of diseases through aerosols. In this study, we developed an antiviral electrostatic precipitator (ESP) with commercially available antiviral films. We applied antiviral surfaces on ESP collection plates and demonstrated that it was effective to remove and inactivate aerosolized viruses in a two-stage ESP. For practical applicability and versatility in indoor air management, the near-zero ozone generation system was applied on the ESP, and four types of viruses, namely MS2 bacteriophage, H1N1, HCoV-229E and -OC43, were selected as suitable surrogates for human and animal respiratory viruses such as SARS-CoV-2. After collection of aerosolized viruses on antiviral surfaces for 30 min, the survivability of the collected viruses was remarkably decreased. We are confident that the findings of this study will demonstrate the viability of ESPs as a promising indoor/private air pollution control technology, boasting exceptional bioaerosol removal and inactivation efficiency. In addition, we aspire for our research to contribute significantly to the prevention of future outbreaks such as COVID-19 by providing a solid foundation for effective measures.
- 22 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1656-1664
Retrofitting of an Air Handling Unit by a Two-Stage Electrostatic Precipitator
A two-stage electrostatic precipitator (ESP) was developed using carbon brush ionizers and lightweight plastic electrodes to be used in an air handling unit (AHU). In a pilot study, the developed ESP emitted near-zero ozone (2.5 collection efficiency higher than 90%. Theoretical analysis revealed that diffusion charging was as important as field charging in the particle charging mechanism. Based on the results of the pilot study, a real AHU of Yuseong Oncheon subway station, South Korea, was retrofitted with the developed ESP. In the field study, a flow distributor was required to achieve uniform flow and minimize the spatial standard deviation of the air flow velocity. Compared to a filter with a minimum efficiency reporting value (MERV) = 14, typically used for particle removal, the pressure drop decreased from 157.1 to 15.2 Pa, and the PM 2.5 collection efficiency increased from 72.7% to 75.0% by the retrofitting of the AHU. The modified quality factor improved more than three-fold, and the required power consumption to operate the device and the fan decreased from 2.49 to 0.85 kW. During ESP operation, the indoor ozone concentration increased by only 1.1 ppbv, whereas the outdoor ozone concentration increased by 30 ppbv. Thus, ESP operation in this study barely increased the indoor ozone concentration.
- 22 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (1) , 1656-1664
Retrofitting of an Air Handling Unit by a Two-Stage Electrostatic Precipitator
A two-stage electrostatic precipitator (ESP) was developed using carbon brush ionizers and lightweight plastic electrodes to be used in an air handling unit (AHU). In a pilot study, the developed ESP emitted near-zero ozone (2.5 collection efficiency higher than 90%. Theoretical analysis revealed that diffusion charging was as important as field charging in the particle charging mechanism. Based on the results of the pilot study, a real AHU of Yuseong Oncheon subway station, South Korea, was retrofitted with the developed ESP. In the field study, a flow distributor was required to achieve uniform flow and minimize the spatial standard deviation of the air flow velocity. Compared to a filter with a minimum efficiency reporting value (MERV) = 14, typically used for particle removal, the pressure drop decreased from 157.1 to 15.2 Pa, and the PM 2.5 collection efficiency increased from 72.7% to 75.0% by the retrofitting of the AHU. The modified quality factor improved more than three-fold, and the required power consumption to operate the device and the fan decreased from 2.49 to 0.85 kW. During ESP operation, the indoor ozone concentration increased by only 1.1 ppbv, whereas the outdoor ozone concentration increased by 30 ppbv. Thus, ESP operation in this study barely increased the indoor ozone concentration.
- 10 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 2932-2942
Gas Absorption and Particle Removal Performance of Wet Parallel-Membrane Array System
In this study, the gas absorption and particle removal performance of wet parallel-membrane array systems were investigated. SO 2 and oil mist were used as the target gas and particles, respectively. To evaluate the gas absorption performance of the wet membrane, we compared it with a packed-bed scrubber at the same flow rate. Unlike a typical packed-bed scrubber, the membrane scrubber has a high absorption rate and easily absorbs water so that the liquid flows dynamically across the entire membrane. Therefore, the membrane exhibited a higher mass transfer rate than the packed bed. Additionally, the pressure drop was extremely low because the flow was not blocked. We evaluated the particle removal performance of a wet two-stage electrostatic precipitator (ESP) with a wet parallel-membrane array collection stage. A PM 2.5 removal efficiency higher than 90% at a flow velocity of 1 m/s was achieved using the proposed system. In addition, the wet-membrane-based two-stage ESP was easy to design according to the existing ESP design theory, Cochet's charging theory, and Deutsch equation. Also, our new wet-membrane-based two-stage ESP can remove acid gas and particles simultaneously. Therefore, this membrane can be a promising material for air pollution control devices, such as scrubbers and ESPs.
- 10 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 2932-2942
Gas Absorption and Particle Removal Performance of Wet Parallel-Membrane Array System
In this study, the gas absorption and particle removal performance of wet parallel-membrane array systems were investigated. SO 2 and oil mist were used as the target gas and particles, respectively. To evaluate the gas absorption performance of the wet membrane, we compared it with a packed-bed scrubber at the same flow rate. Unlike a typical packed-bed scrubber, the membrane scrubber has a high absorption rate and easily absorbs water so that the liquid flows dynamically across the entire membrane. Therefore, the membrane exhibited a higher mass transfer rate than the packed bed. Additionally, the pressure drop was extremely low because the flow was not blocked. We evaluated the particle removal performance of a wet two-stage electrostatic precipitator (ESP) with a wet parallel-membrane array collection stage. A PM 2.5 removal efficiency higher than 90% at a flow velocity of 1 m/s was achieved using the proposed system. In addition, the wet-membrane-based two-stage ESP was easy to design according to the existing ESP design theory, Cochet's charging theory, and Deutsch equation. Also, our new wet-membrane-based two-stage ESP can remove acid gas and particles simultaneously. Therefore, this membrane can be a promising material for air pollution control devices, such as scrubbers and ESPs.
- Open Access
- 25 November 2022
- Published by Wiley in Indoor Air
- Vol. 32 (11) , e13173
Prediction of indoor PM 2.5 concentrations and reduction strategies for cooking events through various IAQ management methods in an apartment of South Korea
Indoor PM2.5 in apartments must be effectively managed to minimize adverse impacts on human health. Cooking is the one of the main PM2.5 sources in apartments, and indoor air quality (IAQ) management methods (natural ventilation, mechanical ventilations, range hoods, and air purifiers) are typically used to reduce PM2.5 generated during cooking. For effective control of indoor PM2.5 , prediction of PM2.5 reduction for various IAQ management methods is necessary. This study carefully predicted indoor PM2.5 concentrations in an apartment when IAQ management methods were applied separately and/or in combination during cooking. The infiltration and exfiltration were verified by comparing the experimental results of CO2 concentration with those predicted with or without mechanical ventilation. The deposition rate for PM2.5 generated by cooking was also derived by comparing the experimental PM2.5 changes with the predicted values for PM2.5 natural decay. Through this method, effective PM2.5 control ways during cooking in apartments can be proposed, such as natural ventilation with a range hood for 30 min and then the operation of an air purifier for 30 min. Additionally, if this prediction is combined with energy consumption, it will be possible to propose the most energy-efficient indoor PM2.5 control methods for various seasons and outdoor conditions.
- 25 November 2022
- Published by Wiley in Indoor Air
- Vol. 32 (11) , e13173
Open AccessPrediction of indoor PM 2.5 concentrations and reduction strategies for cooking events through various IAQ management methods in an apartment of South Korea
Indoor PM2.5 in apartments must be effectively managed to minimize adverse impacts on human health. Cooking is the one of the main PM2.5 sources in apartments, and indoor air quality (IAQ) management methods (natural ventilation, mechanical ventilations, range hoods, and air purifiers) are typically used to reduce PM2.5 generated during cooking. For effective control of indoor PM2.5 , prediction of PM2.5 reduction for various IAQ management methods is necessary. This study carefully predicted indoor PM2.5 concentrations in an apartment when IAQ management methods were applied separately and/or in combination during cooking. The infiltration and exfiltration were verified by comparing the experimental results of CO2 concentration with those predicted with or without mechanical ventilation. The deposition rate for PM2.5 generated by cooking was also derived by comparing the experimental PM2.5 changes with the predicted values for PM2.5 natural decay. Through this method, effective PM2.5 control ways during cooking in apartments can be proposed, such as natural ventilation with a range hood for 30 min and then the operation of an air purifier for 30 min. Additionally, if this prediction is combined with energy consumption, it will be possible to propose the most energy-efficient indoor PM2.5 control methods for various seasons and outdoor conditions.
- Open Access
Improvement of an In-Duct Two-Stage Electrostatic Precipitator via Diffusion Charging
An in-duct two-stage electrostatic precipitator (ESP) improved by ion diffusion effect was studied. We increased the collection efficiency of a two-stage electrostatic precipitator without additional energy input by adjusting the space arrangement of the charger and the collector, which increased the particle diffusion charging time. The collection efficiency and the particle charge were systematically investigated according to the occurrence of diffusion charging and electric field charging in the charger as generated by the negative ions. The collection efficiency of the separated two-stage ESP was 39% higher, on average, than the theoretical efficiency at the same power consumption. Through simulation, it was verified that the ions generated in the carbon fiber ionizer penetrated the charger. We proposed a modified charging mechanism assuming that the penetrated ions cause additional particle charge. The optimal separation distance between the charger and the collector, which showed the maximum collection efficiency, was derived through the modified charging model. Therefore, the in-duct two-stage ESP developed in this study is a promising energy-efficient and cost-saving design for indoor air management.
Open AccessImprovement of an In-Duct Two-Stage Electrostatic Precipitator via Diffusion Charging
An in-duct two-stage electrostatic precipitator (ESP) improved by ion diffusion effect was studied. We increased the collection efficiency of a two-stage electrostatic precipitator without additional energy input by adjusting the space arrangement of the charger and the collector, which increased the particle diffusion charging time. The collection efficiency and the particle charge were systematically investigated according to the occurrence of diffusion charging and electric field charging in the charger as generated by the negative ions. The collection efficiency of the separated two-stage ESP was 39% higher, on average, than the theoretical efficiency at the same power consumption. Through simulation, it was verified that the ions generated in the carbon fiber ionizer penetrated the charger. We proposed a modified charging mechanism assuming that the penetrated ions cause additional particle charge. The optimal separation distance between the charger and the collector, which showed the maximum collection efficiency, was derived through the modified charging model. Therefore, the in-duct two-stage ESP developed in this study is a promising energy-efficient and cost-saving design for indoor air management.
- 28 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 486-491
A Study on the Particle Removal Efficiency and Durability According to the Material of the Ionizer of the Fiber Brush Type Electric Precipitator
In this study, we investigated the particulate matter (PM) removal efficiency and durability of the two-stage electrostatic precipitator (ESP) different materials of brush-typed ionizers (non-metal: carbon fiber/metal : stainless steel (SUS) fiber). The PM removal efficiency was reduced when the average diameter and number of fibers of the brush-typed ionizer increased due to thin and multi-edge in a large number of fibers, which decreased the average electric field, resulting in lower PM removal efficiencies. In contrast with the carbon fiber ionizer, when the SUS fiber ionizer was used, the PM removal efficiency was maintained for a long time, due to its lower electrical resistivity (∼ 6.9 × 10 -7 Ω*m) of the SUS fiber compared with the carbon fiber (∼ 5 × 10 -4 Ω*m), which prevents the positive ions to be stacked on the fiber. Therefore, the present research showed the potential use to apply SUS fiber ionizers as two-stage ESPs for a future air pollution control technology with high PM removal efficiency and durability without ozone emission and additional maintenance.
- 28 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 486-491
A Study on the Particle Removal Efficiency and Durability According to the Material of the Ionizer of the Fiber Brush Type Electric Precipitator
In this study, we investigated the particulate matter (PM) removal efficiency and durability of the two-stage electrostatic precipitator (ESP) different materials of brush-typed ionizers (non-metal: carbon fiber/metal : stainless steel (SUS) fiber). The PM removal efficiency was reduced when the average diameter and number of fibers of the brush-typed ionizer increased due to thin and multi-edge in a large number of fibers, which decreased the average electric field, resulting in lower PM removal efficiencies. In contrast with the carbon fiber ionizer, when the SUS fiber ionizer was used, the PM removal efficiency was maintained for a long time, due to its lower electrical resistivity (∼ 6.9 × 10 -7 Ω*m) of the SUS fiber compared with the carbon fiber (∼ 5 × 10 -4 Ω*m), which prevents the positive ions to be stacked on the fiber. Therefore, the present research showed the potential use to apply SUS fiber ionizers as two-stage ESPs for a future air pollution control technology with high PM removal efficiency and durability without ozone emission and additional maintenance.
- 17 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 473-478
The Electro-Thermal Antimicrobial Carbon Surface
Microorganisms on the surface are important contributors to producing a serious threat to global public health. Herein, we introduce an electro-thermal antimicrobial carbon surface. When a 9V direct voltage was applied to the carbon surface, the carbon fibre surface temperature reached 80°C. This electro-thermal-based antimicrobial carbon surface showed outstanding inactivation performance, exhibiting a potent inactivation rate of ∼99.99% against Gram-positive bacteria ( Staphylococcus epidermidis ) and Gram-negative bacteria ( Escherichia coli ) in just 10 min. Interestingly, under the same temperature, when alternating voltages were applied, electro-thermal antimicrobial performance was enhanced, resulting in a >6.0 log reduction against both Gram-positive and Gram-negative bacteria. In addition, under alternating voltage applied conditions, this excellent electro-thermal-based antimicrobial performance was maintained even at a lower surface temperature (50°C).
- 17 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (1) , 473-478
The Electro-Thermal Antimicrobial Carbon Surface
Microorganisms on the surface are important contributors to producing a serious threat to global public health. Herein, we introduce an electro-thermal antimicrobial carbon surface. When a 9V direct voltage was applied to the carbon surface, the carbon fibre surface temperature reached 80°C. This electro-thermal-based antimicrobial carbon surface showed outstanding inactivation performance, exhibiting a potent inactivation rate of ∼99.99% against Gram-positive bacteria ( Staphylococcus epidermidis ) and Gram-negative bacteria ( Escherichia coli ) in just 10 min. Interestingly, under the same temperature, when alternating voltages were applied, electro-thermal antimicrobial performance was enhanced, resulting in a >6.0 log reduction against both Gram-positive and Gram-negative bacteria. In addition, under alternating voltage applied conditions, this excellent electro-thermal-based antimicrobial performance was maintained even at a lower surface temperature (50°C).
- Open Access
Development of On-Demand Antiviral Electrostatic Precipitators with Electrothermal-Based Antiviral Surfaces against Airborne Virus Particles
Particulate matter, including airborne pathogens, is of particular concern because it can cause the spread of diseases through aerosol transmission. In this study, a new concept is proposed: on-demand antiviral electrostatic precipitators (ESPs) with electrothermal-based antiviral surfaces. We applied electrothermal-based antiviral surfaces to air-purifying applications and demonstrated that the proposed method is effective with regard to collecting airborne virus particles on collection plates in a two-stage ESP. With alternating current power, MS2 bacteriophage and H1N1 viruses were completely deactivated after exposure to 50 °C for 30 min. This remarkable antiviral performance via electrothermal effects indicates that on-demand platforms for self-antiviral surfaces can perform sterilization immediately without generating secondary pollutants, thus effectively preventing the spread of infectious microorganisms in public places. We believe that the results of this study can provide useful guidelines for the design and realization of practical and wearable devices for antiviral air-purifying applications.
Open AccessDevelopment of On-Demand Antiviral Electrostatic Precipitators with Electrothermal-Based Antiviral Surfaces against Airborne Virus Particles
Particulate matter, including airborne pathogens, is of particular concern because it can cause the spread of diseases through aerosol transmission. In this study, a new concept is proposed: on-demand antiviral electrostatic precipitators (ESPs) with electrothermal-based antiviral surfaces. We applied electrothermal-based antiviral surfaces to air-purifying applications and demonstrated that the proposed method is effective with regard to collecting airborne virus particles on collection plates in a two-stage ESP. With alternating current power, MS2 bacteriophage and H1N1 viruses were completely deactivated after exposure to 50 °C for 30 min. This remarkable antiviral performance via electrothermal effects indicates that on-demand platforms for self-antiviral surfaces can perform sterilization immediately without generating secondary pollutants, thus effectively preventing the spread of infectious microorganisms in public places. We believe that the results of this study can provide useful guidelines for the design and realization of practical and wearable devices for antiviral air-purifying applications.