Bangwoo Han
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bangwoo Han has a total of 101 co-authors. Here are the top co-authors by number of shared publications:
- Hak-Joon Kim
Eco-Friendly Energy & Environment Research Division, Korea Institute of Machinery and Materials, Daejeon, South Korea
35 shared publications Yong-Jin Kim
Department of Sustainable Environment Research, Korea Institute of Machinery & Materials, Daejeon, Republic of Korea
19 shared publications- Yong-Jin Kim
Eco-Friendly Energy & Environment Research Division, Korea Institute of Machinery and Materials, Daejeon, South Korea
19 shared publications - Yeawan Lee
Department of Sustainable Environment Research, Korea Institute of Machinery and Materials, Daejeon, South Korea
12 shared publications - Gunhee Lee
Department of Urban Environment Research, Korea Institute of Machinery and Materials, Daejeon, Republic of Korea
11 shared publications Hak-Joon Kim
Department of Sustainable Environment Research, Korea Institute of Machinery & Materials, Daejeon, Republic of Korea
11 shared publications
Latest Publications
- Open Access
- 25 October 2026
- Published by Elsevier in SSRN Electronic Journal
Characterization and optimization of an ion spray air cleaner: housing material and ionizer geometry effects on clean air delivery rate
Indoor particulate matter exposure has become a critical global health concern, and filter-based air cleaners have been widely used. However, it has critical shortcomings regarding frequent filter replacement and high energy consumption caused by the pressure drop across the filter. Electrostatic precipitator-based cleaners are a promising alternative, and the ion-spray configuration offers low pressure drop and low ozone emission. Therefore, we designed and evaluated an ion-spray ESP to maximize the clean air delivery rate (CADR). Although the local ion concentration differed by four orders of magnitude between a near-source and a far zone, the 8.3 m3 min-1 non-metal-frame lab device in a 30 m3 chamber achieved similar CADRs of 7.44 and 7.24 m3 min-1. The metal-frame CADR ranged from 5.6 to 7.4 m3 min-1 with ionizer length (0.4–15 cm) and from 5.9 to 7.1 m3 min-1 with tilt angle (0–90°), whereas the non-metal-frame CADR remained essentially constant at approximately 7.3 m3 min-1 regardless of geometry. The 40 m3 min-1 metal-frame pilot device in a 300 m3 chamber reached 29 m3 min-1 CADR at 0° tilt, and average CADRs were 23.8 m3 min-1. In addition, the ion-spray ESP exhibited a pressure drop of 13.5 Pa, which was 3.5-fold lower than that of the HEPA filter, and an ozone emission below 2 ppb. Therefore, the ion-spray ESP is expected to be an efficient low-energy, low-ozone air-cleaning system for improving indoor air quality in large spaces, offering a promising alternative to conventional filter- and two-stage ESP-based cleaners.
- 25 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCharacterization and optimization of an ion spray air cleaner: housing material and ionizer geometry effects on clean air delivery rate
Indoor particulate matter exposure has become a critical global health concern, and filter-based air cleaners have been widely used. However, it has critical shortcomings regarding frequent filter replacement and high energy consumption caused by the pressure drop across the filter. Electrostatic precipitator-based cleaners are a promising alternative, and the ion-spray configuration offers low pressure drop and low ozone emission. Therefore, we designed and evaluated an ion-spray ESP to maximize the clean air delivery rate (CADR). Although the local ion concentration differed by four orders of magnitude between a near-source and a far zone, the 8.3 m3 min-1 non-metal-frame lab device in a 30 m3 chamber achieved similar CADRs of 7.44 and 7.24 m3 min-1. The metal-frame CADR ranged from 5.6 to 7.4 m3 min-1 with ionizer length (0.4–15 cm) and from 5.9 to 7.1 m3 min-1 with tilt angle (0–90°), whereas the non-metal-frame CADR remained essentially constant at approximately 7.3 m3 min-1 regardless of geometry. The 40 m3 min-1 metal-frame pilot device in a 300 m3 chamber reached 29 m3 min-1 CADR at 0° tilt, and average CADRs were 23.8 m3 min-1. In addition, the ion-spray ESP exhibited a pressure drop of 13.5 Pa, which was 3.5-fold lower than that of the HEPA filter, and an ozone emission below 2 ppb. Therefore, the ion-spray ESP is expected to be an efficient low-energy, low-ozone air-cleaning system for improving indoor air quality in large spaces, offering a promising alternative to conventional filter- and two-stage ESP-based cleaners.
- Open Access
- 14 October 2026
- Published by Elsevier in Building and Environment
- Vol. 306
Air purifier performance in an occupied office: Field CADR and effectiveness from a reconstructed device-off condition
- 14 October 2026
- Published by Elsevier in Building and Environment
- Vol. 306
Open AccessAir purifier performance in an occupied office: Field CADR and effectiveness from a reconstructed device-off condition
- Open Access
- 9 September 2026
- Published by Elsevier in SSRN Electronic Journal
Chemical-free Non-Packing Scrubber–Electrochemical System for Industrial Gaseous NH3 Removal
Ammonia (NH3) emitted from semiconductor manufacturing is conventionally treated by packed-bed wet scrubber. However, this approach suffers from absorbent acidity depletion and high pressure drop inherent to the packing design. To overcome these limitations, an integrated non-packing scrubber-electrochemical regeneration system was developed for continuous, chemical-free NH3 removal and absorbent reuse. In the non-packing scrubber, NH3 removal reached 98% at an L/G ratio of 7 L m-3 and remained above 95% at absorbent pH < 8. However, scrubber-only operation could not maintain stable performance without chemical addition because the absorbent progressively lost acidity during NH3 absorption. With 0.005 M H2SO4, the NH3 removal efficiency decreased from >95% to ~45% and recovered to 95% only after additional acid addition. However, the integrated system with electrochemical cell maintained the absorbent under acidic conditions without external chemical dosing and sustained NH3 removal above 95% for 3 h. Under total ammonia nitrogen (TAN)-enriched conditions, the electrochemical nitrogen flux reached 250–260 g N m⁻2 d⁻1, which was comparable to or greater than the nitrogen loading from 100 ppm NH3 scrubbing, indicating that absorbed ammonium could be removed from the recirculating solution as rapidly as it was introduced. In addition, TAN was enriched above 5000 ppm, the average energy consumption was 3.7 kWh kg N⁻1. These results show that, unlike scrubber-only operation requiring repeated chemical addition, the integrated system enables stable and more energy-efficient continuous NH3 removal and recovery.
- 9 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessChemical-free Non-Packing Scrubber–Electrochemical System for Industrial Gaseous NH3 Removal
Ammonia (NH3) emitted from semiconductor manufacturing is conventionally treated by packed-bed wet scrubber. However, this approach suffers from absorbent acidity depletion and high pressure drop inherent to the packing design. To overcome these limitations, an integrated non-packing scrubber-electrochemical regeneration system was developed for continuous, chemical-free NH3 removal and absorbent reuse. In the non-packing scrubber, NH3 removal reached 98% at an L/G ratio of 7 L m-3 and remained above 95% at absorbent pH < 8. However, scrubber-only operation could not maintain stable performance without chemical addition because the absorbent progressively lost acidity during NH3 absorption. With 0.005 M H2SO4, the NH3 removal efficiency decreased from >95% to ~45% and recovered to 95% only after additional acid addition. However, the integrated system with electrochemical cell maintained the absorbent under acidic conditions without external chemical dosing and sustained NH3 removal above 95% for 3 h. Under total ammonia nitrogen (TAN)-enriched conditions, the electrochemical nitrogen flux reached 250–260 g N m⁻2 d⁻1, which was comparable to or greater than the nitrogen loading from 100 ppm NH3 scrubbing, indicating that absorbed ammonium could be removed from the recirculating solution as rapidly as it was introduced. In addition, TAN was enriched above 5000 ppm, the average energy consumption was 3.7 kWh kg N⁻1. These results show that, unlike scrubber-only operation requiring repeated chemical addition, the integrated system enables stable and more energy-efficient continuous NH3 removal and recovery.
- Open Access
- 29 July 2026
- Published by Elsevier in Building and Environment
- Vol. 304
Field-informed reinforcement learning for multi-objective indoor air quality control in naturally ventilated buildings
- 29 July 2026
- Published by Elsevier in Building and Environment
- Vol. 304
Open AccessField-informed reinforcement learning for multi-objective indoor air quality control in naturally ventilated buildings
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 677-683
On-Site Test on Fine Dust Reduction in Subway Station Using Electrostatic Type Air Purifier
This study investigates the effect of an electrostatic-type air handling unit (ES-AHU) for improving indoor air quality at subway station. The ES-AHU features a pre-charger with carbon microfiber electrodes and a non- metallic collecting plate. It achieved particulate matter collection efficiency exceeding 90% for both PM2.5 and PM10. This performance is approximately 1.3 to 1.5 times higher than those of conventional filter-based air handling unit. In addition, the ES-AHU reduced PM2.5 concentration in the waiting room area and platform decreased by over 50%. The results of the spatial distribution analysis showed that the PM2.5 concentration in the waiting room varies depending on the location, suggesting that it is important to consider the spatial characteristics for effective air quality improvement. The ES- AHU applied in this study shows the potential to enhance air quality and promote a healthier environment for passengers by improving the existing ventilation system at subway stations.
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 677-683
On-Site Test on Fine Dust Reduction in Subway Station Using Electrostatic Type Air Purifier
This study investigates the effect of an electrostatic-type air handling unit (ES-AHU) for improving indoor air quality at subway station. The ES-AHU features a pre-charger with carbon microfiber electrodes and a non- metallic collecting plate. It achieved particulate matter collection efficiency exceeding 90% for both PM2.5 and PM10. This performance is approximately 1.3 to 1.5 times higher than those of conventional filter-based air handling unit. In addition, the ES-AHU reduced PM2.5 concentration in the waiting room area and platform decreased by over 50%. The results of the spatial distribution analysis showed that the PM2.5 concentration in the waiting room varies depending on the location, suggesting that it is important to consider the spatial characteristics for effective air quality improvement. The ES- AHU applied in this study shows the potential to enhance air quality and promote a healthier environment for passengers by improving the existing ventilation system at subway stations.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 8194-8200
Removal of Ammonium and Fluoride From Industrial Wastewater by Sonoelectrochemical Precipitation
Wastewater from the semiconductor industry typically contains substantial amounts of total ammonia nitrogen (TAN) and fluoride that can have adverse effects on the environment. The present study examined the efficacy of a sonoelectrochemical system which applies ultrasonic waves to an electrochemical process in removing these species from wastewater. Application of the sonoelectrochemical process with a current of 2 A, and a sonication frequency of 40 kHz to synthetic wastewater resulted in a TAN removal efficiency of 52.2% . pH was the main factor affecting TAN crystallization, with alkaline conditions in combination with a sonication frequency of 40 kHz being optimal for TAN removal. In terms of fluoride removal, application of the sonoelectrochemical process for 1.5 h achieved a removal efficiency of 98% at pH 7. The main precipitates obtained were Al-F complexes. The present findings indicate that the sonoelectrochemical process is a feasible and cost-effective approach for use in the recycling of industrial wastewater.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 8194-8200
Removal of Ammonium and Fluoride From Industrial Wastewater by Sonoelectrochemical Precipitation
Wastewater from the semiconductor industry typically contains substantial amounts of total ammonia nitrogen (TAN) and fluoride that can have adverse effects on the environment. The present study examined the efficacy of a sonoelectrochemical system which applies ultrasonic waves to an electrochemical process in removing these species from wastewater. Application of the sonoelectrochemical process with a current of 2 A, and a sonication frequency of 40 kHz to synthetic wastewater resulted in a TAN removal efficiency of 52.2% . pH was the main factor affecting TAN crystallization, with alkaline conditions in combination with a sonication frequency of 40 kHz being optimal for TAN removal. In terms of fluoride removal, application of the sonoelectrochemical process for 1.5 h achieved a removal efficiency of 98% at pH 7. The main precipitates obtained were Al-F complexes. The present findings indicate that the sonoelectrochemical process is a feasible and cost-effective approach for use in the recycling of industrial wastewater.
- 10 April 2025
- Published by Elsevier in Chemosphere
- Vol. 378, 144387
Absorption of nitrogen dioxide via a non-packing scrubber using a sulfite/thiosulfate complex absorbent
- 10 April 2025
- Published by Elsevier in Chemosphere
- Vol. 378, 144387
Absorption of nitrogen dioxide via a non-packing scrubber using a sulfite/thiosulfate complex absorbent
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5649-5654
Evaluation of Antiviral Electrostatic Precipitator With Commercially Antiviral Films Coated on Collection Plates Against Aerosolized Viruses
The presence of particulate matter (PM), which may contain airborne pathogens, raises significant concerns because of its ability to facilitate the transmission of diseases through aerosols. In this study, we developed an antiviral electrostatic precipitator (ESP) with commercially available antiviral films. We applied antiviral surfaces on ESP collection plates and demonstrated that it was effective to remove and inactivate aerosolized viruses in a two-stage ESP. For practical applicability and versatility in indoor air management, the near-zero ozone generation system was applied on the ESP, and four types of viruses, namely MS2 bacteriophage, H1N1, HCoV-229E and -OC43, were selected as suitable surrogates for human and animal respiratory viruses such as SARS-CoV-2. After collection of aerosolized viruses on antiviral surfaces for 30 min, the survivability of the collected viruses was remarkably decreased. We are confident that the findings of this study will demonstrate the viability of ESPs as a promising indoor/private air pollution control technology, boasting exceptional bioaerosol removal and inactivation efficiency. In addition, we aspire for our research to contribute significantly to the prevention of future outbreaks such as COVID-19 by providing a solid foundation for effective measures.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5649-5654
Evaluation of Antiviral Electrostatic Precipitator With Commercially Antiviral Films Coated on Collection Plates Against Aerosolized Viruses
The presence of particulate matter (PM), which may contain airborne pathogens, raises significant concerns because of its ability to facilitate the transmission of diseases through aerosols. In this study, we developed an antiviral electrostatic precipitator (ESP) with commercially available antiviral films. We applied antiviral surfaces on ESP collection plates and demonstrated that it was effective to remove and inactivate aerosolized viruses in a two-stage ESP. For practical applicability and versatility in indoor air management, the near-zero ozone generation system was applied on the ESP, and four types of viruses, namely MS2 bacteriophage, H1N1, HCoV-229E and -OC43, were selected as suitable surrogates for human and animal respiratory viruses such as SARS-CoV-2. After collection of aerosolized viruses on antiviral surfaces for 30 min, the survivability of the collected viruses was remarkably decreased. We are confident that the findings of this study will demonstrate the viability of ESPs as a promising indoor/private air pollution control technology, boasting exceptional bioaerosol removal and inactivation efficiency. In addition, we aspire for our research to contribute significantly to the prevention of future outbreaks such as COVID-19 by providing a solid foundation for effective measures.
- Open Access
Strategies for Effective Management of Indoor Air Quality in a Kindergarten: CO2 and Fine Particulate Matter Concentrations
The educational and play-related activities of children proceed mainly indoors in a kindergarten. High concentrations of indoor PM2.5 and CO2 have been linked to various harmful effects on children, considerably impacting their educational outcomes in kindergarten. In this study, we explore different scenarios involving the operation of mechanical ventilation systems and air purifiers in kindergartens. Using numerical models to analyze indoor CO2 and PM2.5 concentration, we aim to optimize strategies that effectively reduce these harmful pollutants. We found that the amount of ventilation required to maintain good air quality, per child, was approximately 20.4 m3/h. However, we also found that as the amount of ventilation increased, so did the concentration of indoor PM2.5; we found that this issue can be resolved using a high-grade filter (i.e., a MERV 13 grade filter with a collection efficiency of 75%). This study provides a scientific basis for reducing PM2.5 concentrations in kindergartens, while keeping CO2 levels low.
Open AccessStrategies for Effective Management of Indoor Air Quality in a Kindergarten: CO2 and Fine Particulate Matter Concentrations
The educational and play-related activities of children proceed mainly indoors in a kindergarten. High concentrations of indoor PM2.5 and CO2 have been linked to various harmful effects on children, considerably impacting their educational outcomes in kindergarten. In this study, we explore different scenarios involving the operation of mechanical ventilation systems and air purifiers in kindergartens. Using numerical models to analyze indoor CO2 and PM2.5 concentration, we aim to optimize strategies that effectively reduce these harmful pollutants. We found that the amount of ventilation required to maintain good air quality, per child, was approximately 20.4 m3/h. However, we also found that as the amount of ventilation increased, so did the concentration of indoor PM2.5; we found that this issue can be resolved using a high-grade filter (i.e., a MERV 13 grade filter with a collection efficiency of 75%). This study provides a scientific basis for reducing PM2.5 concentrations in kindergartens, while keeping CO2 levels low.
- Open Access
The Effectiveness of a Mechanical Ventilation System for Indoor PM2.5 in Residential Houses
The mechanical ventilation systems used in houses are designed to reduce carbon dioxide emissions while minimizing the energy loss resulting from ventilation. However, the increase in indoor fine particulate (PM2.5) concentration because of external PM2.5 influx through the ventilation system poses a problem. Here, we analyzed the changes in indoor PM2.5 concentration, distinguishing between cases of high and low outdoor PM2.5 concentrations and considering the efficiency of the filters used in residential mechanical ventilation systems. When using filters with the minimum efficiency reporting value (MERV) of 10 in the ventilation system, the outdoor PM2.5 concentration was 5 μg/m³; compared to the initial concentration, the indoor PM2.5 concentration after 60 min decreased to 73%. When the outdoor PM2.5 concentration was 30–40 μg/m³, the indoor PM2.5 concentration reached 91%. However, when MERV 13 filters were used, the indoor PM2.5 concentration consistently dropped to 73–76%, regardless of the outdoor PM2.5 concentration. Furthermore, by comparing the established equation with the mass balance model, the error was confirmed to be within 5%, indicating a good fit. This allows for the prediction of indoor PM2.5 under various conditions when using mechanical ventilation systems, enabling the formulation of strategies for maintaining indoor PM2.5, as recommended by the World Health Organization.
Open AccessThe Effectiveness of a Mechanical Ventilation System for Indoor PM2.5 in Residential Houses
The mechanical ventilation systems used in houses are designed to reduce carbon dioxide emissions while minimizing the energy loss resulting from ventilation. However, the increase in indoor fine particulate (PM2.5) concentration because of external PM2.5 influx through the ventilation system poses a problem. Here, we analyzed the changes in indoor PM2.5 concentration, distinguishing between cases of high and low outdoor PM2.5 concentrations and considering the efficiency of the filters used in residential mechanical ventilation systems. When using filters with the minimum efficiency reporting value (MERV) of 10 in the ventilation system, the outdoor PM2.5 concentration was 5 μg/m³; compared to the initial concentration, the indoor PM2.5 concentration after 60 min decreased to 73%. When the outdoor PM2.5 concentration was 30–40 μg/m³, the indoor PM2.5 concentration reached 91%. However, when MERV 13 filters were used, the indoor PM2.5 concentration consistently dropped to 73–76%, regardless of the outdoor PM2.5 concentration. Furthermore, by comparing the established equation with the mass balance model, the error was confirmed to be within 5%, indicating a good fit. This allows for the prediction of indoor PM2.5 under various conditions when using mechanical ventilation systems, enabling the formulation of strategies for maintaining indoor PM2.5, as recommended by the World Health Organization.