Hak-Joon Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hak-Joon Kim has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Bangwoo Han
Eco-Friendly Energy & Environment Research Division, Korea Institute of Machinery and Materials, Daejeon, South Korea
35 shared publications - Yong-Jin Kim
Eco-Friendly Energy & Environment Research Division, Korea Institute of Machinery and Materials, Daejeon, South Korea
20 shared publications - Yeawan Lee
Department of Sustainable Environment Research, Korea Institute of Machinery and Materials, Daejeon, South Korea
15 shared publications Yong-Jin Kim
11 shared publicationsYe-Sle Kim
9 shared publicationsBangwoo Han
7 shared publications
Latest Publications
- Open Access
- 25 October 2026
- Published by Elsevier in SSRN Electronic Journal
Characterization and optimization of an ion spray air cleaner: housing material and ionizer geometry effects on clean air delivery rate
Indoor particulate matter exposure has become a critical global health concern, and filter-based air cleaners have been widely used. However, it has critical shortcomings regarding frequent filter replacement and high energy consumption caused by the pressure drop across the filter. Electrostatic precipitator-based cleaners are a promising alternative, and the ion-spray configuration offers low pressure drop and low ozone emission. Therefore, we designed and evaluated an ion-spray ESP to maximize the clean air delivery rate (CADR). Although the local ion concentration differed by four orders of magnitude between a near-source and a far zone, the 8.3 m3 min-1 non-metal-frame lab device in a 30 m3 chamber achieved similar CADRs of 7.44 and 7.24 m3 min-1. The metal-frame CADR ranged from 5.6 to 7.4 m3 min-1 with ionizer length (0.4–15 cm) and from 5.9 to 7.1 m3 min-1 with tilt angle (0–90°), whereas the non-metal-frame CADR remained essentially constant at approximately 7.3 m3 min-1 regardless of geometry. The 40 m3 min-1 metal-frame pilot device in a 300 m3 chamber reached 29 m3 min-1 CADR at 0° tilt, and average CADRs were 23.8 m3 min-1. In addition, the ion-spray ESP exhibited a pressure drop of 13.5 Pa, which was 3.5-fold lower than that of the HEPA filter, and an ozone emission below 2 ppb. Therefore, the ion-spray ESP is expected to be an efficient low-energy, low-ozone air-cleaning system for improving indoor air quality in large spaces, offering a promising alternative to conventional filter- and two-stage ESP-based cleaners.
- 25 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessCharacterization and optimization of an ion spray air cleaner: housing material and ionizer geometry effects on clean air delivery rate
Indoor particulate matter exposure has become a critical global health concern, and filter-based air cleaners have been widely used. However, it has critical shortcomings regarding frequent filter replacement and high energy consumption caused by the pressure drop across the filter. Electrostatic precipitator-based cleaners are a promising alternative, and the ion-spray configuration offers low pressure drop and low ozone emission. Therefore, we designed and evaluated an ion-spray ESP to maximize the clean air delivery rate (CADR). Although the local ion concentration differed by four orders of magnitude between a near-source and a far zone, the 8.3 m3 min-1 non-metal-frame lab device in a 30 m3 chamber achieved similar CADRs of 7.44 and 7.24 m3 min-1. The metal-frame CADR ranged from 5.6 to 7.4 m3 min-1 with ionizer length (0.4–15 cm) and from 5.9 to 7.1 m3 min-1 with tilt angle (0–90°), whereas the non-metal-frame CADR remained essentially constant at approximately 7.3 m3 min-1 regardless of geometry. The 40 m3 min-1 metal-frame pilot device in a 300 m3 chamber reached 29 m3 min-1 CADR at 0° tilt, and average CADRs were 23.8 m3 min-1. In addition, the ion-spray ESP exhibited a pressure drop of 13.5 Pa, which was 3.5-fold lower than that of the HEPA filter, and an ozone emission below 2 ppb. Therefore, the ion-spray ESP is expected to be an efficient low-energy, low-ozone air-cleaning system for improving indoor air quality in large spaces, offering a promising alternative to conventional filter- and two-stage ESP-based cleaners.
- Open Access
- 9 September 2026
- Published by Elsevier in SSRN Electronic Journal
Chemical-free Non-Packing Scrubber–Electrochemical System for Industrial Gaseous NH3 Removal
Ammonia (NH3) emitted from semiconductor manufacturing is conventionally treated by packed-bed wet scrubber. However, this approach suffers from absorbent acidity depletion and high pressure drop inherent to the packing design. To overcome these limitations, an integrated non-packing scrubber-electrochemical regeneration system was developed for continuous, chemical-free NH3 removal and absorbent reuse. In the non-packing scrubber, NH3 removal reached 98% at an L/G ratio of 7 L m-3 and remained above 95% at absorbent pH < 8. However, scrubber-only operation could not maintain stable performance without chemical addition because the absorbent progressively lost acidity during NH3 absorption. With 0.005 M H2SO4, the NH3 removal efficiency decreased from >95% to ~45% and recovered to 95% only after additional acid addition. However, the integrated system with electrochemical cell maintained the absorbent under acidic conditions without external chemical dosing and sustained NH3 removal above 95% for 3 h. Under total ammonia nitrogen (TAN)-enriched conditions, the electrochemical nitrogen flux reached 250–260 g N m⁻2 d⁻1, which was comparable to or greater than the nitrogen loading from 100 ppm NH3 scrubbing, indicating that absorbed ammonium could be removed from the recirculating solution as rapidly as it was introduced. In addition, TAN was enriched above 5000 ppm, the average energy consumption was 3.7 kWh kg N⁻1. These results show that, unlike scrubber-only operation requiring repeated chemical addition, the integrated system enables stable and more energy-efficient continuous NH3 removal and recovery.
- 9 September 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessChemical-free Non-Packing Scrubber–Electrochemical System for Industrial Gaseous NH3 Removal
Ammonia (NH3) emitted from semiconductor manufacturing is conventionally treated by packed-bed wet scrubber. However, this approach suffers from absorbent acidity depletion and high pressure drop inherent to the packing design. To overcome these limitations, an integrated non-packing scrubber-electrochemical regeneration system was developed for continuous, chemical-free NH3 removal and absorbent reuse. In the non-packing scrubber, NH3 removal reached 98% at an L/G ratio of 7 L m-3 and remained above 95% at absorbent pH < 8. However, scrubber-only operation could not maintain stable performance without chemical addition because the absorbent progressively lost acidity during NH3 absorption. With 0.005 M H2SO4, the NH3 removal efficiency decreased from >95% to ~45% and recovered to 95% only after additional acid addition. However, the integrated system with electrochemical cell maintained the absorbent under acidic conditions without external chemical dosing and sustained NH3 removal above 95% for 3 h. Under total ammonia nitrogen (TAN)-enriched conditions, the electrochemical nitrogen flux reached 250–260 g N m⁻2 d⁻1, which was comparable to or greater than the nitrogen loading from 100 ppm NH3 scrubbing, indicating that absorbed ammonium could be removed from the recirculating solution as rapidly as it was introduced. In addition, TAN was enriched above 5000 ppm, the average energy consumption was 3.7 kWh kg N⁻1. These results show that, unlike scrubber-only operation requiring repeated chemical addition, the integrated system enables stable and more energy-efficient continuous NH3 removal and recovery.
- Open Access
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1)
A Wearable Electronic Device With an Air Curtain Shield and Two‐Stage Curved Electrostatic Precipitation Module for Personal Respirator Protection
Conventional face masks suffer from limitations such as high pressure drop, discomfort, and limited reusability. To address these issues, we developed a wearable respiratory protection device (WRPD) that combines an air curtain shield with a curved electrostatic precipitation (EP) module. The curved EP module showed a high fine particle (0.3 μ m) removal efficiency of 99.3 % ± 0.6 % at −3.5 kV and generated low levels of ozone below 0.24 ppb. However, the efficiency of the EP module decreased to 85.8 % ± 0.8 % when it was integrated into the WRPD. In the WRPD, the air curtain shield efficiently blocked airborne and droplet‐sized particles with 91.6 % ± 1.8 % efficiency at flow rates exceeding 241 L/min under 0.7 m/s particle intrusion but showed limited effectiveness for submicron particles. However, the full WRPD system with both the air curtain shield and curved EP module operating achieved 94.5% removal efficiency for submicron particles and 99.8 % ± 0.2 % for larger airborne and droplet‐sized particles. The air curtain shield not only prevented ambient air mixing but also enhanced the purity of the air delivered by the curved EP module by more than 10% compared to the WRPD operated using only the EP module.
- 1 January 2026
- Published by Wiley in Indoor Air
- Vol. 2026 (1)
Open AccessA Wearable Electronic Device With an Air Curtain Shield and Two‐Stage Curved Electrostatic Precipitation Module for Personal Respirator Protection
Conventional face masks suffer from limitations such as high pressure drop, discomfort, and limited reusability. To address these issues, we developed a wearable respiratory protection device (WRPD) that combines an air curtain shield with a curved electrostatic precipitation (EP) module. The curved EP module showed a high fine particle (0.3 μ m) removal efficiency of 99.3 % ± 0.6 % at −3.5 kV and generated low levels of ozone below 0.24 ppb. However, the efficiency of the EP module decreased to 85.8 % ± 0.8 % when it was integrated into the WRPD. In the WRPD, the air curtain shield efficiently blocked airborne and droplet‐sized particles with 91.6 % ± 1.8 % efficiency at flow rates exceeding 241 L/min under 0.7 m/s particle intrusion but showed limited effectiveness for submicron particles. However, the full WRPD system with both the air curtain shield and curved EP module operating achieved 94.5% removal efficiency for submicron particles and 99.8 % ± 0.2 % for larger airborne and droplet‐sized particles. The air curtain shield not only prevented ambient air mixing but also enhanced the purity of the air delivered by the curved EP module by more than 10% compared to the WRPD operated using only the EP module.
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 677-683
On-Site Test on Fine Dust Reduction in Subway Station Using Electrostatic Type Air Purifier
This study investigates the effect of an electrostatic-type air handling unit (ES-AHU) for improving indoor air quality at subway station. The ES-AHU features a pre-charger with carbon microfiber electrodes and a non- metallic collecting plate. It achieved particulate matter collection efficiency exceeding 90% for both PM2.5 and PM10. This performance is approximately 1.3 to 1.5 times higher than those of conventional filter-based air handling unit. In addition, the ES-AHU reduced PM2.5 concentration in the waiting room area and platform decreased by over 50%. The results of the spatial distribution analysis showed that the PM2.5 concentration in the waiting room varies depending on the location, suggesting that it is important to consider the spatial characteristics for effective air quality improvement. The ES- AHU applied in this study shows the potential to enhance air quality and promote a healthier environment for passengers by improving the existing ventilation system at subway stations.
- 21 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (1) , 677-683
On-Site Test on Fine Dust Reduction in Subway Station Using Electrostatic Type Air Purifier
This study investigates the effect of an electrostatic-type air handling unit (ES-AHU) for improving indoor air quality at subway station. The ES-AHU features a pre-charger with carbon microfiber electrodes and a non- metallic collecting plate. It achieved particulate matter collection efficiency exceeding 90% for both PM2.5 and PM10. This performance is approximately 1.3 to 1.5 times higher than those of conventional filter-based air handling unit. In addition, the ES-AHU reduced PM2.5 concentration in the waiting room area and platform decreased by over 50%. The results of the spatial distribution analysis showed that the PM2.5 concentration in the waiting room varies depending on the location, suggesting that it is important to consider the spatial characteristics for effective air quality improvement. The ES- AHU applied in this study shows the potential to enhance air quality and promote a healthier environment for passengers by improving the existing ventilation system at subway stations.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 8194-8200
Removal of Ammonium and Fluoride From Industrial Wastewater by Sonoelectrochemical Precipitation
Wastewater from the semiconductor industry typically contains substantial amounts of total ammonia nitrogen (TAN) and fluoride that can have adverse effects on the environment. The present study examined the efficacy of a sonoelectrochemical system which applies ultrasonic waves to an electrochemical process in removing these species from wastewater. Application of the sonoelectrochemical process with a current of 2 A, and a sonication frequency of 40 kHz to synthetic wastewater resulted in a TAN removal efficiency of 52.2% . pH was the main factor affecting TAN crystallization, with alkaline conditions in combination with a sonication frequency of 40 kHz being optimal for TAN removal. In terms of fluoride removal, application of the sonoelectrochemical process for 1.5 h achieved a removal efficiency of 98% at pH 7. The main precipitates obtained were Al-F complexes. The present findings indicate that the sonoelectrochemical process is a feasible and cost-effective approach for use in the recycling of industrial wastewater.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (5) , 8194-8200
Removal of Ammonium and Fluoride From Industrial Wastewater by Sonoelectrochemical Precipitation
Wastewater from the semiconductor industry typically contains substantial amounts of total ammonia nitrogen (TAN) and fluoride that can have adverse effects on the environment. The present study examined the efficacy of a sonoelectrochemical system which applies ultrasonic waves to an electrochemical process in removing these species from wastewater. Application of the sonoelectrochemical process with a current of 2 A, and a sonication frequency of 40 kHz to synthetic wastewater resulted in a TAN removal efficiency of 52.2% . pH was the main factor affecting TAN crystallization, with alkaline conditions in combination with a sonication frequency of 40 kHz being optimal for TAN removal. In terms of fluoride removal, application of the sonoelectrochemical process for 1.5 h achieved a removal efficiency of 98% at pH 7. The main precipitates obtained were Al-F complexes. The present findings indicate that the sonoelectrochemical process is a feasible and cost-effective approach for use in the recycling of industrial wastewater.
- 10 April 2025
- Published by Elsevier in Chemosphere
- Vol. 378, 144387
Absorption of nitrogen dioxide via a non-packing scrubber using a sulfite/thiosulfate complex absorbent
- 10 April 2025
- Published by Elsevier in Chemosphere
- Vol. 378, 144387
Absorption of nitrogen dioxide via a non-packing scrubber using a sulfite/thiosulfate complex absorbent
- Open Access
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Development of an Electrostatic Precipitator With a Novel Dry‐Cleaning Apparatus for Building Ventilation Systems
Electrostatic precipitators (ESPs) offer a durable solution for enhancing indoor air quality. However, traditional cleaning techniques often pose financial burdens and result in issues such as electrode degradation and particle re‐entrainment, which is crucial for building management. In this study, we introduced an ESP with a novel dry‐cleaning apparatus tailored for indoor air purification systems. The novel cleaning apparatus utilized a combination of compressed air‐blasting and vacuum suction mechanisms to dislodge and extract particles from the collection plates. Moreover, the ESP incorporated a two‐stage design featuring a charger equipped with carbon brush ionizers and a collector comprising carbon ink–coated plastic plates. This design not only mitigates ozone emissions but also reduces installation costs. Our results revealed a consistent cleaning efficiency exceeding 98% under optimal operational conditions, restoring reduced collection efficiency due to contamination. Finally, we conducted field demonstration experiments in subway stations. We retrofitted an air handling unit with our ESP system and dry‐cleaning apparatus, showing a collection efficiency of 99.4% for PM 1 . To validate the efficacy of our dry‐cleaning apparatus, we conducted a 16‐day test at a vent outlet of a subway station. The field demonstration of the dry‐cleaning apparatus showcased nearly flawless recovery of collection efficiency to the initial state. In summary, our investigation represents a significant advancement in overcoming the prevailing challenges associated with ESP utilization in indoor air purification applications.
- 1 January 2025
- Published by Wiley in Indoor Air
- Vol. 2025 (1)
Open AccessDevelopment of an Electrostatic Precipitator With a Novel Dry‐Cleaning Apparatus for Building Ventilation Systems
Electrostatic precipitators (ESPs) offer a durable solution for enhancing indoor air quality. However, traditional cleaning techniques often pose financial burdens and result in issues such as electrode degradation and particle re‐entrainment, which is crucial for building management. In this study, we introduced an ESP with a novel dry‐cleaning apparatus tailored for indoor air purification systems. The novel cleaning apparatus utilized a combination of compressed air‐blasting and vacuum suction mechanisms to dislodge and extract particles from the collection plates. Moreover, the ESP incorporated a two‐stage design featuring a charger equipped with carbon brush ionizers and a collector comprising carbon ink–coated plastic plates. This design not only mitigates ozone emissions but also reduces installation costs. Our results revealed a consistent cleaning efficiency exceeding 98% under optimal operational conditions, restoring reduced collection efficiency due to contamination. Finally, we conducted field demonstration experiments in subway stations. We retrofitted an air handling unit with our ESP system and dry‐cleaning apparatus, showing a collection efficiency of 99.4% for PM 1 . To validate the efficacy of our dry‐cleaning apparatus, we conducted a 16‐day test at a vent outlet of a subway station. The field demonstration of the dry‐cleaning apparatus showcased nearly flawless recovery of collection efficiency to the initial state. In summary, our investigation represents a significant advancement in overcoming the prevailing challenges associated with ESP utilization in indoor air purification applications.
- 26 March 2024
- Published by Elsevier in Chemosphere
- Vol. 355, 141809
Lab- and pilot-scale wet scrubber study on the redox-mediated simultaneous removal of NOx and SO2 using a CaCO3-based slurry with KI as a redox catalyst
- 26 March 2024
- Published by Elsevier in Chemosphere
- Vol. 355, 141809
Lab- and pilot-scale wet scrubber study on the redox-mediated simultaneous removal of NOx and SO2 using a CaCO3-based slurry with KI as a redox catalyst
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5649-5654
Evaluation of Antiviral Electrostatic Precipitator With Commercially Antiviral Films Coated on Collection Plates Against Aerosolized Viruses
The presence of particulate matter (PM), which may contain airborne pathogens, raises significant concerns because of its ability to facilitate the transmission of diseases through aerosols. In this study, we developed an antiviral electrostatic precipitator (ESP) with commercially available antiviral films. We applied antiviral surfaces on ESP collection plates and demonstrated that it was effective to remove and inactivate aerosolized viruses in a two-stage ESP. For practical applicability and versatility in indoor air management, the near-zero ozone generation system was applied on the ESP, and four types of viruses, namely MS2 bacteriophage, H1N1, HCoV-229E and -OC43, were selected as suitable surrogates for human and animal respiratory viruses such as SARS-CoV-2. After collection of aerosolized viruses on antiviral surfaces for 30 min, the survivability of the collected viruses was remarkably decreased. We are confident that the findings of this study will demonstrate the viability of ESPs as a promising indoor/private air pollution control technology, boasting exceptional bioaerosol removal and inactivation efficiency. In addition, we aspire for our research to contribute significantly to the prevention of future outbreaks such as COVID-19 by providing a solid foundation for effective measures.
- 25 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 60 (4) , 5649-5654
Evaluation of Antiviral Electrostatic Precipitator With Commercially Antiviral Films Coated on Collection Plates Against Aerosolized Viruses
The presence of particulate matter (PM), which may contain airborne pathogens, raises significant concerns because of its ability to facilitate the transmission of diseases through aerosols. In this study, we developed an antiviral electrostatic precipitator (ESP) with commercially available antiviral films. We applied antiviral surfaces on ESP collection plates and demonstrated that it was effective to remove and inactivate aerosolized viruses in a two-stage ESP. For practical applicability and versatility in indoor air management, the near-zero ozone generation system was applied on the ESP, and four types of viruses, namely MS2 bacteriophage, H1N1, HCoV-229E and -OC43, were selected as suitable surrogates for human and animal respiratory viruses such as SARS-CoV-2. After collection of aerosolized viruses on antiviral surfaces for 30 min, the survivability of the collected viruses was remarkably decreased. We are confident that the findings of this study will demonstrate the viability of ESPs as a promising indoor/private air pollution control technology, boasting exceptional bioaerosol removal and inactivation efficiency. In addition, we aspire for our research to contribute significantly to the prevention of future outbreaks such as COVID-19 by providing a solid foundation for effective measures.
- Open Access
- 1 February 2024
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2702 (1) , 012008
Particle removal performance of a novel ESP type air cleaning system for indoor air quality in a subway station
A novel electrostatic precipitation type air cleaning technology with near zero ozone emission for indoor air quality of a subway station was developed. To minimize ozone emission and achieve high particle removal performance against ultrafine particulate matters (PMs), a multi-channel charging method using soft ionization by micrometre carbon fibers and a narrow gap collection method using high electric field by thin conductive plastic sheets as a high voltage electrode were used. In this study, the novel electrostatic charging and collection technologies were applied to a real scale air cleaning system in an Air Handling Unit (AHU) with air flow rate of 950 m3/min in Yuseong Oncheon subway station with an area of 3000 m2 in Daejeon, South Korea. The particle removal performance of the demonstration system was evaluated with real suspended particles in the subway station during test period with high PM concentrations in Korea over 40 μg/m3. Particle collection efficiency, pressure drop and ozone emission were evaluated, and compared to those of the a minimum efficiency reporting value (MERV) 10 and 14 filters used in the typical subway stations in Korea. In the field researches, the developed ESP achieved over 80% of the PM collection efficiency higher than those of the filters with MERV-10 and -14, and even 10% higher efficiency against PM1.0, while generating only 10% of pressure drop and also emitting nearly zero ozone. It is concluded that a novel ESP type air cleaning system with near zero ozone emission could be a promising air cleaning method for a large indoor environment such as a subway station where polluted air with ultrafine particles flowed in with a very high flow rate.
- 1 February 2024
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2702 (1) , 012008
Open AccessParticle removal performance of a novel ESP type air cleaning system for indoor air quality in a subway station
A novel electrostatic precipitation type air cleaning technology with near zero ozone emission for indoor air quality of a subway station was developed. To minimize ozone emission and achieve high particle removal performance against ultrafine particulate matters (PMs), a multi-channel charging method using soft ionization by micrometre carbon fibers and a narrow gap collection method using high electric field by thin conductive plastic sheets as a high voltage electrode were used. In this study, the novel electrostatic charging and collection technologies were applied to a real scale air cleaning system in an Air Handling Unit (AHU) with air flow rate of 950 m3/min in Yuseong Oncheon subway station with an area of 3000 m2 in Daejeon, South Korea. The particle removal performance of the demonstration system was evaluated with real suspended particles in the subway station during test period with high PM concentrations in Korea over 40 μg/m3. Particle collection efficiency, pressure drop and ozone emission were evaluated, and compared to those of the a minimum efficiency reporting value (MERV) 10 and 14 filters used in the typical subway stations in Korea. In the field researches, the developed ESP achieved over 80% of the PM collection efficiency higher than those of the filters with MERV-10 and -14, and even 10% higher efficiency against PM1.0, while generating only 10% of pressure drop and also emitting nearly zero ozone. It is concluded that a novel ESP type air cleaning system with near zero ozone emission could be a promising air cleaning method for a large indoor environment such as a subway station where polluted air with ultrafine particles flowed in with a very high flow rate.