Stephen P. Lee
Stephen P. Lee has a total of 191 co-authors. Here are the top co-authors by number of shared publications:
- John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
7 shared publications - Roozbeh Ghaffari
Epicore Biosystems, Inc
7 shared publications Roozbeh Ghaffari
Center for Bio-Integrated Electronics, Simpson Querrey Institute for BioNanotechnology, Northwestern University, Evanston, IL 60208, USA
6 shared publications- Alexander J. Aranyosi
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, USA
4 shared publications John A. Wright
Epicore Biosystems, Inc
4 shared publications- Jungil Choi
Department of Mechanical Engineering, Ajou University, Suwon, Republic of Korea
4 shared publications
Latest Publications
- Open Access
- 12 August 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (33)
Remote analysis and management of sweat biomarkers using a wearable microfluidic sticker in adult cystic fibrosis patients
Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold standard for a CF diagnosis, but this technique is cumbersome and not suitable for remote settings or repeat measurements. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here, we conducted clinical studies assessing the accuracy of the CF Patch compared to chloridometry when using pilocarpine to induce sweat. We also tested the feasibility and accuracy of exercise-induced sweat chloride measurements in PwCF and healthy volunteers (HV). In the laboratory, using either pilocarpine or exercise to induce sweat, the CF Patch demonstrated strong correlations with sweat chloride measured by pilocarpine-induced chloridometry. In remote settings, exercise-induced sweat chlorides measured using the CF patch were strongly correlated with in-laboratory exercise-induced CF patch sweat chlorides in HV but had a weaker correlation in PwCF. For PwCF on CFTR modulators, there was greater day-to-day variability in sweat chloride compared to HV, which highlights the limitations of assessing CFTR modulator efficacy and pharmacodynamics based on a single in-laboratory chloridometry measurement. Moreover, these findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring serial sweat chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens but should not replace pilocarpine-based chloridometry for making a CF diagnosis.
- 12 August 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (33)
Open AccessRemote analysis and management of sweat biomarkers using a wearable microfluidic sticker in adult cystic fibrosis patients
Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold standard for a CF diagnosis, but this technique is cumbersome and not suitable for remote settings or repeat measurements. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here, we conducted clinical studies assessing the accuracy of the CF Patch compared to chloridometry when using pilocarpine to induce sweat. We also tested the feasibility and accuracy of exercise-induced sweat chloride measurements in PwCF and healthy volunteers (HV). In the laboratory, using either pilocarpine or exercise to induce sweat, the CF Patch demonstrated strong correlations with sweat chloride measured by pilocarpine-induced chloridometry. In remote settings, exercise-induced sweat chlorides measured using the CF patch were strongly correlated with in-laboratory exercise-induced CF patch sweat chlorides in HV but had a weaker correlation in PwCF. For PwCF on CFTR modulators, there was greater day-to-day variability in sweat chloride compared to HV, which highlights the limitations of assessing CFTR modulator efficacy and pharmacodynamics based on a single in-laboratory chloridometry measurement. Moreover, these findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring serial sweat chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens but should not replace pilocarpine-based chloridometry for making a CF diagnosis.
- Top Cited PapersOpen Access
- 1 February 2025
- Published by Springer Nature in npj Digital Medicine
- Vol. 8 (1) , 1-12
Wearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers
Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors. Here we present a closed-loop electrochemical/biophysical wearable sensing device and algorithms that directly measure whole-body sweat loss, sweating rate, sodium concentration, and sodium loss with electrode arrays embedded in a microfluidic channel. The device contains two temperature sensors for skin temperature and thermal flux recordings, and an accelerometer for real-time monitoring of activity level. An onboard haptic module enables vibratory feedback cues to the wearer once critical sweat loss thresholds are reached. Data is stored onboard in memory and autonomously transmitted via Bluetooth to a smartphone and cloud portal. Field studies conducted in physically demanding activities demonstrate the key capabilities of this platform to inform hydration interventions in highly challenging real-world settings.
- 1 February 2025
- Published by Springer Nature in npj Digital Medicine
- Vol. 8 (1) , 1-12
Top Cited PapersOpen AccessWearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers
Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors. Here we present a closed-loop electrochemical/biophysical wearable sensing device and algorithms that directly measure whole-body sweat loss, sweating rate, sodium concentration, and sodium loss with electrode arrays embedded in a microfluidic channel. The device contains two temperature sensors for skin temperature and thermal flux recordings, and an accelerometer for real-time monitoring of activity level. An onboard haptic module enables vibratory feedback cues to the wearer once critical sweat loss thresholds are reached. Data is stored onboard in memory and autonomously transmitted via Bluetooth to a smartphone and cloud portal. Field studies conducted in physically demanding activities demonstrate the key capabilities of this platform to inform hydration interventions in highly challenging real-world settings.
- Top Cited Papers
- 31 March 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 13 (587)
Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management
A soft, wearable microfluidic platform collects and quantitatively analyzes sweat biomarkers to improve the diagnosis of cystic fibrosis.
- 31 March 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 13 (587)
Top Cited PapersSoft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management
A soft, wearable microfluidic platform collects and quantitatively analyzes sweat biomarkers to improve the diagnosis of cystic fibrosis.
- Top Cited Papers
- 29 March 2021
- Published by Springer Nature in Nature Electronics
- Vol. 4 (4) , 302-312
An on-skin platform for wireless monitoring of flow rate, cumulative loss and temperature of sweat in real time
- 29 March 2021
- Published by Springer Nature in Nature Electronics
- Vol. 4 (4) , 302-312
Top Cited PapersAn on-skin platform for wireless monitoring of flow rate, cumulative loss and temperature of sweat in real time
- Top Cited PapersOpen Access
- 11 December 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (50) , eabe3929
Skin-interfaced microfluidic system with personalized sweating rate and sweat chloride analytics for sports science applications
Advanced capabilities in noninvasive, in situ monitoring of sweating rate and sweat electrolyte losses could enable real-time personalized fluid-electrolyte intake recommendations. Established sweat analysis techniques using absorbent patches require post-collection harvesting and benchtop analysis of sweat and are thus impractical for ambulatory use. Here, we introduce a skin-interfaced wearable microfluidic device and smartphone image processing platform that enable analysis of regional sweating rate and sweat chloride concentration ([Cl−]). Systematic studies (n = 312 athletes) establish significant correlations for regional sweating rate and sweat [Cl−] in a controlled environment and during competitive sports under varying environmental conditions. The regional sweating rate and sweat [Cl−] results serve as inputs to algorithms implemented on a smartphone software application that predicts whole-body sweating rate and sweat [Cl−]. This low-cost wearable sensing approach could improve the accessibility of physiological insights available to sports scientists, practitioners, and athletes to inform hydration strategies in real-world ambulatory settings.
- 11 December 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (50) , eabe3929
Top Cited PapersOpen AccessSkin-interfaced microfluidic system with personalized sweating rate and sweat chloride analytics for sports science applications
Advanced capabilities in noninvasive, in situ monitoring of sweating rate and sweat electrolyte losses could enable real-time personalized fluid-electrolyte intake recommendations. Established sweat analysis techniques using absorbent patches require post-collection harvesting and benchtop analysis of sweat and are thus impractical for ambulatory use. Here, we introduce a skin-interfaced wearable microfluidic device and smartphone image processing platform that enable analysis of regional sweating rate and sweat chloride concentration ([Cl−]). Systematic studies (n = 312 athletes) establish significant correlations for regional sweating rate and sweat [Cl−] in a controlled environment and during competitive sports under varying environmental conditions. The regional sweating rate and sweat [Cl−] results serve as inputs to algorithms implemented on a smartphone software application that predicts whole-body sweating rate and sweat [Cl−]. This low-cost wearable sensing approach could improve the accessibility of physiological insights available to sports scientists, practitioners, and athletes to inform hydration strategies in real-world ambulatory settings.
- 13 July 2020
- Published by Springer Nature in Nature Electronics
- Vol. 3 (9) , 554-562
Sweat-activated biocompatible batteries for epidermal electronic and microfluidic systems
- 13 July 2020
- Published by Springer Nature in Nature Electronics
- Vol. 3 (9) , 554-562
Sweat-activated biocompatible batteries for epidermal electronic and microfluidic systems
- Top Cited PapersOpen Access
- 4 January 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (1) , eaav3294
Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat
Battery-free, wireless microfluidic/electronic system for multiparameter sweat analysis.
- 4 January 2019
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 5 (1) , eaav3294
Top Cited PapersOpen AccessBattery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat
Battery-free, wireless microfluidic/electronic system for multiparameter sweat analysis.
- Open Access
- 25 January 2018
- Published by Springer Nature in npj Digital Medicine
- Vol. 1 (1) , 1-7
Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring
Contemporary cardiac and heart rate monitoring devices capture physiological signals using optical and electrode-based sensors. However, these devices generally lack the form factor and mechanical flexibility necessary for use in ambulatory and home environments. Here, we report an ultrathin (~1 mm average thickness) and highly flexible wearable cardiac sensor (WiSP) designed to be minimal in cost (disposable), light weight (1.2 g), water resistant, and capable of wireless energy harvesting. Theoretical analyses of system-level bending mechanics show the advantages of WiSP’s flexible electronics, soft encapsulation layers and bioadhesives, enabling intimate skin coupling. A clinical feasibility study conducted in atrial fibrillation patients demonstrates that the WiSP device effectively measures cardiac signals matching the Holter monitor, and is more comfortable. WiSP’s physical attributes and performance results demonstrate its utility for monitoring cardiac signals during daily activity, exertion and sleep, with implications for home-based care.
- 25 January 2018
- Published by Springer Nature in npj Digital Medicine
- Vol. 1 (1) , 1-7
Open AccessHighly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring
Contemporary cardiac and heart rate monitoring devices capture physiological signals using optical and electrode-based sensors. However, these devices generally lack the form factor and mechanical flexibility necessary for use in ambulatory and home environments. Here, we report an ultrathin (~1 mm average thickness) and highly flexible wearable cardiac sensor (WiSP) designed to be minimal in cost (disposable), light weight (1.2 g), water resistant, and capable of wireless energy harvesting. Theoretical analyses of system-level bending mechanics show the advantages of WiSP’s flexible electronics, soft encapsulation layers and bioadhesives, enabling intimate skin coupling. A clinical feasibility study conducted in atrial fibrillation patients demonstrates that the WiSP device effectively measures cardiac signals matching the Holter monitor, and is more comfortable. WiSP’s physical attributes and performance results demonstrate its utility for monitoring cardiac signals during daily activity, exertion and sleep, with implications for home-based care.
- 1 April 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 78, 290-299
Flexible opto-electronics enabled microfluidics systems with cloud connectivity for point-of-care micronutrient analysis
- 1 April 2016
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 78, 290-299
Flexible opto-electronics enabled microfluidics systems with cloud connectivity for point-of-care micronutrient analysis
- Open Access
- 1 September 2015
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 5, 55-61
Rapid light transmittance measurements in paper-based microfluidic devices
- 1 September 2015
- Published by Elsevier in Sensing and Bio-Sensing Research
- Vol. 5, 55-61
Open AccessRapid light transmittance measurements in paper-based microfluidic devices