Roozbeh Ghaffari
Roozbeh Ghaffari has a total of 288 co-authors. Here are the top co-authors by number of shared publications:
- John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
17 shared publications Stephen P. Lee
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, USA
7 shared publications- Stephen P. Lee
Epicore Biosystems, Inc
7 shared publications - Alexander J. Aranyosi
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, USA
6 shared publications Alexander J. Aranyosi
Epicore Biosystems, Inc., Cambridge, USA
5 shared publicationsDa Som Yang
School of Mechanical Engineering, Chung-Ang University
5 shared publications
Latest Publications
- Open Access
Validation of a Wearable Photoplethysmography-Based Sensor for Compensatory Reserve Measurement Monitoring in Simulated Human Hemorrhage
Hemorrhagic shock remains a leading cause of preventable death in trauma, yet traditional vital signs may fail to reflect early blood loss before physiological compensatory mechanisms are no longer able to maintain hemodynamic stability. The Compensatory Reserve Measurement (CRM) algorithm offers early detection capability using physiological waveforms but requires testing with emerging wearable sensor technologies for operational deployment. This study tested the Epicore Epidermal Patch for Imperceptible Care (EPIC) wearable healthcare device (WHD) for CRM-based hemodynamic monitoring during progressive central hypovolemia induced by lower-body negative pressure (LBNP) to simulate hemorrhage. Twenty participants underwent progressive LBNP while photoplethysmography (PPG) signals were recorded from EPIC sensors placed at the clavicle and triceps alongside a clinical-grade finger pulse oximeter for reference. Signal quality, heart-rate accuracy, and CRM predictions were evaluated across multiple filtering approaches. The triceps placement achieved signal quality comparable to the pulse oximeter reference when Chebyshev Type II filtering was applied, as well as high heart-rate accuracy. CRM derived from the EPIC sensor placed at the triceps tracked compensatory trends during progressive hypovolemia, but prediction magnitudes were inaccurate compared to calculated CRM values. In contrast, the clavicle placement consistently performed poorly across all measurements, regardless of the signal-processing approach. These findings support the feasibility of soft, flexible wearable sensors for continuous hemorrhage monitoring at the triceps location in operational environments where traditional finger-based pulse oximetry is impractical.
Open AccessValidation of a Wearable Photoplethysmography-Based Sensor for Compensatory Reserve Measurement Monitoring in Simulated Human Hemorrhage
Hemorrhagic shock remains a leading cause of preventable death in trauma, yet traditional vital signs may fail to reflect early blood loss before physiological compensatory mechanisms are no longer able to maintain hemodynamic stability. The Compensatory Reserve Measurement (CRM) algorithm offers early detection capability using physiological waveforms but requires testing with emerging wearable sensor technologies for operational deployment. This study tested the Epicore Epidermal Patch for Imperceptible Care (EPIC) wearable healthcare device (WHD) for CRM-based hemodynamic monitoring during progressive central hypovolemia induced by lower-body negative pressure (LBNP) to simulate hemorrhage. Twenty participants underwent progressive LBNP while photoplethysmography (PPG) signals were recorded from EPIC sensors placed at the clavicle and triceps alongside a clinical-grade finger pulse oximeter for reference. Signal quality, heart-rate accuracy, and CRM predictions were evaluated across multiple filtering approaches. The triceps placement achieved signal quality comparable to the pulse oximeter reference when Chebyshev Type II filtering was applied, as well as high heart-rate accuracy. CRM derived from the EPIC sensor placed at the triceps tracked compensatory trends during progressive hypovolemia, but prediction magnitudes were inaccurate compared to calculated CRM values. In contrast, the clavicle placement consistently performed poorly across all measurements, regardless of the signal-processing approach. These findings support the feasibility of soft, flexible wearable sensors for continuous hemorrhage monitoring at the triceps location in operational environments where traditional finger-based pulse oximetry is impractical.
- Open Access
- 12 August 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (33)
Remote analysis and management of sweat biomarkers using a wearable microfluidic sticker in adult cystic fibrosis patients
Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold standard for a CF diagnosis, but this technique is cumbersome and not suitable for remote settings or repeat measurements. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here, we conducted clinical studies assessing the accuracy of the CF Patch compared to chloridometry when using pilocarpine to induce sweat. We also tested the feasibility and accuracy of exercise-induced sweat chloride measurements in PwCF and healthy volunteers (HV). In the laboratory, using either pilocarpine or exercise to induce sweat, the CF Patch demonstrated strong correlations with sweat chloride measured by pilocarpine-induced chloridometry. In remote settings, exercise-induced sweat chlorides measured using the CF patch were strongly correlated with in-laboratory exercise-induced CF patch sweat chlorides in HV but had a weaker correlation in PwCF. For PwCF on CFTR modulators, there was greater day-to-day variability in sweat chloride compared to HV, which highlights the limitations of assessing CFTR modulator efficacy and pharmacodynamics based on a single in-laboratory chloridometry measurement. Moreover, these findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring serial sweat chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens but should not replace pilocarpine-based chloridometry for making a CF diagnosis.
- 12 August 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (33)
Open AccessRemote analysis and management of sweat biomarkers using a wearable microfluidic sticker in adult cystic fibrosis patients
Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold standard for a CF diagnosis, but this technique is cumbersome and not suitable for remote settings or repeat measurements. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here, we conducted clinical studies assessing the accuracy of the CF Patch compared to chloridometry when using pilocarpine to induce sweat. We also tested the feasibility and accuracy of exercise-induced sweat chloride measurements in PwCF and healthy volunteers (HV). In the laboratory, using either pilocarpine or exercise to induce sweat, the CF Patch demonstrated strong correlations with sweat chloride measured by pilocarpine-induced chloridometry. In remote settings, exercise-induced sweat chlorides measured using the CF patch were strongly correlated with in-laboratory exercise-induced CF patch sweat chlorides in HV but had a weaker correlation in PwCF. For PwCF on CFTR modulators, there was greater day-to-day variability in sweat chloride compared to HV, which highlights the limitations of assessing CFTR modulator efficacy and pharmacodynamics based on a single in-laboratory chloridometry measurement. Moreover, these findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring serial sweat chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens but should not replace pilocarpine-based chloridometry for making a CF diagnosis.
- 9 June 2025
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 2 (6) , 371-372
Wearable electrochemical biosensors for remote hydration and health management
- 9 June 2025
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 2 (6) , 371-372
Wearable electrochemical biosensors for remote hydration and health management
- Open Access
Remote exercise-induced sweat chloride measurements using a wearable microfluidic sticker in cystic fibrosis patients
Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold-standard for sweat chloride, but this technique is cumbersome and not suitable for remote settings. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here we conducted clinical studies characterizing the accuracy of the CF Patch compared to pilocarpine-induced sweat measurements using chloridometry and tested the feasibility of exercise-induced sweat chloride measurements in PwCF. The CF Patch demonstrated strong correlations compared to sweat chloride measured by chloridometry across clinic and remote settings and detected greater day-to-day sweat chloride variability in PwCF on CFTR modulators than healthy volunteers. These findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens.
Open AccessRemote exercise-induced sweat chloride measurements using a wearable microfluidic sticker in cystic fibrosis patients
Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold-standard for sweat chloride, but this technique is cumbersome and not suitable for remote settings. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here we conducted clinical studies characterizing the accuracy of the CF Patch compared to pilocarpine-induced sweat measurements using chloridometry and tested the feasibility of exercise-induced sweat chloride measurements in PwCF. The CF Patch demonstrated strong correlations compared to sweat chloride measured by chloridometry across clinic and remote settings and detected greater day-to-day sweat chloride variability in PwCF on CFTR modulators than healthy volunteers. These findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens.
- Top Cited PapersOpen Access
- 1 February 2025
- Published by Springer Nature in npj Digital Medicine
- Vol. 8 (1) , 1-12
Wearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers
Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors. Here we present a closed-loop electrochemical/biophysical wearable sensing device and algorithms that directly measure whole-body sweat loss, sweating rate, sodium concentration, and sodium loss with electrode arrays embedded in a microfluidic channel. The device contains two temperature sensors for skin temperature and thermal flux recordings, and an accelerometer for real-time monitoring of activity level. An onboard haptic module enables vibratory feedback cues to the wearer once critical sweat loss thresholds are reached. Data is stored onboard in memory and autonomously transmitted via Bluetooth to a smartphone and cloud portal. Field studies conducted in physically demanding activities demonstrate the key capabilities of this platform to inform hydration interventions in highly challenging real-world settings.
- 1 February 2025
- Published by Springer Nature in npj Digital Medicine
- Vol. 8 (1) , 1-12
Top Cited PapersOpen AccessWearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers
Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors. Here we present a closed-loop electrochemical/biophysical wearable sensing device and algorithms that directly measure whole-body sweat loss, sweating rate, sodium concentration, and sodium loss with electrode arrays embedded in a microfluidic channel. The device contains two temperature sensors for skin temperature and thermal flux recordings, and an accelerometer for real-time monitoring of activity level. An onboard haptic module enables vibratory feedback cues to the wearer once critical sweat loss thresholds are reached. Data is stored onboard in memory and autonomously transmitted via Bluetooth to a smartphone and cloud portal. Field studies conducted in physically demanding activities demonstrate the key capabilities of this platform to inform hydration interventions in highly challenging real-world settings.
- 20 March 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (3) , 182-184
The potential of wearable sweat sensors in heart failure management
- 20 March 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (3) , 182-184
The potential of wearable sweat sensors in heart failure management
- 23 February 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 253, 116166
A skin-interfaced, miniaturized platform for triggered induction, capture and colorimetric multicomponent analysis of microliter volumes of sweat
- 23 February 2024
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 253, 116166
A skin-interfaced, miniaturized platform for triggered induction, capture and colorimetric multicomponent analysis of microliter volumes of sweat
- 16 January 2024
- Published by Elsevier in Trends in Biotechnology
- Vol. 42 (3) , 255-257
Next-generation digital biomarkers: continuous molecular health monitoring using wearable devices
- 16 January 2024
- Published by Elsevier in Trends in Biotechnology
- Vol. 42 (3) , 255-257
Next-generation digital biomarkers: continuous molecular health monitoring using wearable devices
- Open Access
- 3 January 2024
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 104 (2)
Early Prediction of Poststroke Rehabilitation Outcomes Using Wearable Sensors
Objective: Inpatient rehabilitation represents a critical setting for stroke treatment, providing intensive, targeted therapy and task-specific practice to minimize a patient’s functional deficits and facilitate their reintegration into the community. However, impairment and recovery vary greatly after stroke, making it difficult to predict a patient’s future outcomes or response to treatment. In this study, the authors examined the value of early-stage wearable sensor data to predict 3 functional outcomes (ambulation, independence, and risk of falling) at rehabilitation discharge.Methods: Fifty-five individuals undergoing inpatient stroke rehabilitation participated in this study. Supervised machine learning classifiers were retrospectively trained to predict discharge outcomes using data collected at hospital admission, including patient information, functional assessment scores, and inertial sensor data from the lower limbs during gait and/or balance tasks. Model performance was compared across different data combinations and was benchmarked against a traditional model trained without sensor data.Results: For patients who were ambulatory at admission, sensor data improved the predictions of ambulation and risk of falling (with weighted F1 scores increasing by 19.6% and 23.4%, respectively) and maintained similar performance for predictions of independence, compared to a benchmark model without sensor data. The best-performing sensor-based models predicted discharge ambulation (community vs household), independence (high vs low), and risk of falling (normal vs high) with accuracies of 84.4%, 68.8%, and 65.9%, respectively. Most misclassifications occurred with admission or discharge scores near the classification boundary. For patients who were nonambulatory at admission, sensor data recorded during simple balance tasks did not offer predictive value over the benchmark models.Conclusion: These findings support the continued investigation of wearable sensors as an accessible, easy-to-use tool to predict the functional recovery after stroke.Impact: Accurate, early prediction of poststroke rehabilitation outcomes from wearable sensors would improve our ability to deliver personalized, effective care and discharge planning in the inpatient setting and beyond.
- 3 January 2024
- Published by Oxford University Press (OUP) in Physical Therapy
- Vol. 104 (2)
Open AccessEarly Prediction of Poststroke Rehabilitation Outcomes Using Wearable Sensors
Objective: Inpatient rehabilitation represents a critical setting for stroke treatment, providing intensive, targeted therapy and task-specific practice to minimize a patient’s functional deficits and facilitate their reintegration into the community. However, impairment and recovery vary greatly after stroke, making it difficult to predict a patient’s future outcomes or response to treatment. In this study, the authors examined the value of early-stage wearable sensor data to predict 3 functional outcomes (ambulation, independence, and risk of falling) at rehabilitation discharge.Methods: Fifty-five individuals undergoing inpatient stroke rehabilitation participated in this study. Supervised machine learning classifiers were retrospectively trained to predict discharge outcomes using data collected at hospital admission, including patient information, functional assessment scores, and inertial sensor data from the lower limbs during gait and/or balance tasks. Model performance was compared across different data combinations and was benchmarked against a traditional model trained without sensor data.Results: For patients who were ambulatory at admission, sensor data improved the predictions of ambulation and risk of falling (with weighted F1 scores increasing by 19.6% and 23.4%, respectively) and maintained similar performance for predictions of independence, compared to a benchmark model without sensor data. The best-performing sensor-based models predicted discharge ambulation (community vs household), independence (high vs low), and risk of falling (normal vs high) with accuracies of 84.4%, 68.8%, and 65.9%, respectively. Most misclassifications occurred with admission or discharge scores near the classification boundary. For patients who were nonambulatory at admission, sensor data recorded during simple balance tasks did not offer predictive value over the benchmark models.Conclusion: These findings support the continued investigation of wearable sensors as an accessible, easy-to-use tool to predict the functional recovery after stroke.Impact: Accurate, early prediction of poststroke rehabilitation outcomes from wearable sensors would improve our ability to deliver personalized, effective care and discharge planning in the inpatient setting and beyond.
- Top Cited Papers
- 27 April 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1252-1269
A wireless and battery-less implant for multimodal closed-loop neuromodulation in small animals
- 27 April 2023
- Published by Springer Nature in Nature Biomedical Engineering
- Vol. 7 (10) , 1252-1269
Top Cited PapersA wireless and battery-less implant for multimodal closed-loop neuromodulation in small animals