Alexander J. Aranyosi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexander J. Aranyosi has a total of 194 co-authors. Here are the top co-authors by number of shared publications:
Roozbeh Ghaffari
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, USA
12 shared publicationsDennis M. Freeman
Research Laboratory of Electronics, MIT
7 shared publications- Roozbeh Ghaffari
Epicore Biosystems, Inc
6 shared publications - John Allen Rogers
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL, 60208, USA
5 shared publications Stephen P. Lee
Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, USA
4 shared publications- Stephen P. Lee
Epicore Biosystems, Inc
4 shared publications
Latest Publications
- Open Access
Validation of a Wearable Photoplethysmography-Based Sensor for Compensatory Reserve Measurement Monitoring in Simulated Human Hemorrhage
Hemorrhagic shock remains a leading cause of preventable death in trauma, yet traditional vital signs may fail to reflect early blood loss before physiological compensatory mechanisms are no longer able to maintain hemodynamic stability. The Compensatory Reserve Measurement (CRM) algorithm offers early detection capability using physiological waveforms but requires testing with emerging wearable sensor technologies for operational deployment. This study tested the Epicore Epidermal Patch for Imperceptible Care (EPIC) wearable healthcare device (WHD) for CRM-based hemodynamic monitoring during progressive central hypovolemia induced by lower-body negative pressure (LBNP) to simulate hemorrhage. Twenty participants underwent progressive LBNP while photoplethysmography (PPG) signals were recorded from EPIC sensors placed at the clavicle and triceps alongside a clinical-grade finger pulse oximeter for reference. Signal quality, heart-rate accuracy, and CRM predictions were evaluated across multiple filtering approaches. The triceps placement achieved signal quality comparable to the pulse oximeter reference when Chebyshev Type II filtering was applied, as well as high heart-rate accuracy. CRM derived from the EPIC sensor placed at the triceps tracked compensatory trends during progressive hypovolemia, but prediction magnitudes were inaccurate compared to calculated CRM values. In contrast, the clavicle placement consistently performed poorly across all measurements, regardless of the signal-processing approach. These findings support the feasibility of soft, flexible wearable sensors for continuous hemorrhage monitoring at the triceps location in operational environments where traditional finger-based pulse oximetry is impractical.
Open AccessValidation of a Wearable Photoplethysmography-Based Sensor for Compensatory Reserve Measurement Monitoring in Simulated Human Hemorrhage
Hemorrhagic shock remains a leading cause of preventable death in trauma, yet traditional vital signs may fail to reflect early blood loss before physiological compensatory mechanisms are no longer able to maintain hemodynamic stability. The Compensatory Reserve Measurement (CRM) algorithm offers early detection capability using physiological waveforms but requires testing with emerging wearable sensor technologies for operational deployment. This study tested the Epicore Epidermal Patch for Imperceptible Care (EPIC) wearable healthcare device (WHD) for CRM-based hemodynamic monitoring during progressive central hypovolemia induced by lower-body negative pressure (LBNP) to simulate hemorrhage. Twenty participants underwent progressive LBNP while photoplethysmography (PPG) signals were recorded from EPIC sensors placed at the clavicle and triceps alongside a clinical-grade finger pulse oximeter for reference. Signal quality, heart-rate accuracy, and CRM predictions were evaluated across multiple filtering approaches. The triceps placement achieved signal quality comparable to the pulse oximeter reference when Chebyshev Type II filtering was applied, as well as high heart-rate accuracy. CRM derived from the EPIC sensor placed at the triceps tracked compensatory trends during progressive hypovolemia, but prediction magnitudes were inaccurate compared to calculated CRM values. In contrast, the clavicle placement consistently performed poorly across all measurements, regardless of the signal-processing approach. These findings support the feasibility of soft, flexible wearable sensors for continuous hemorrhage monitoring at the triceps location in operational environments where traditional finger-based pulse oximetry is impractical.
- Top Cited PapersOpen Access
- 15 January 2026
- Published by Springer Nature in Nature Sensors
- Vol. 1 (1) , 85-98
Wearable lateral flow assays for cortisol monitoring with time-dynamic sweat sampling and sensing by electrochromic timers
- 15 January 2026
- Published by Springer Nature in Nature Sensors
- Vol. 1 (1) , 85-98
Top Cited PapersOpen AccessWearable lateral flow assays for cortisol monitoring with time-dynamic sweat sampling and sensing by electrochromic timers
- Open Access
- 12 August 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (33)
Remote analysis and management of sweat biomarkers using a wearable microfluidic sticker in adult cystic fibrosis patients
Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold standard for a CF diagnosis, but this technique is cumbersome and not suitable for remote settings or repeat measurements. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here, we conducted clinical studies assessing the accuracy of the CF Patch compared to chloridometry when using pilocarpine to induce sweat. We also tested the feasibility and accuracy of exercise-induced sweat chloride measurements in PwCF and healthy volunteers (HV). In the laboratory, using either pilocarpine or exercise to induce sweat, the CF Patch demonstrated strong correlations with sweat chloride measured by pilocarpine-induced chloridometry. In remote settings, exercise-induced sweat chlorides measured using the CF patch were strongly correlated with in-laboratory exercise-induced CF patch sweat chlorides in HV but had a weaker correlation in PwCF. For PwCF on CFTR modulators, there was greater day-to-day variability in sweat chloride compared to HV, which highlights the limitations of assessing CFTR modulator efficacy and pharmacodynamics based on a single in-laboratory chloridometry measurement. Moreover, these findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring serial sweat chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens but should not replace pilocarpine-based chloridometry for making a CF diagnosis.
- 12 August 2025
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 122 (33)
Open AccessRemote analysis and management of sweat biomarkers using a wearable microfluidic sticker in adult cystic fibrosis patients
Sweat parameters such as volume and chloride concentration may offer invaluable clinical insights for people with CF (PwCF). Pilocarpine-induced sweat collection for chloridometry measurement is the gold standard for a CF diagnosis, but this technique is cumbersome and not suitable for remote settings or repeat measurements. We have previously reported the utility of a skin-interfaced microfluidic device (CF Patch) in conjunction with a smartphone image processing platform that enables real-time measurement of sweating rates and sodium chloride loss in laboratory and remote settings. Here, we conducted clinical studies assessing the accuracy of the CF Patch compared to chloridometry when using pilocarpine to induce sweat. We also tested the feasibility and accuracy of exercise-induced sweat chloride measurements in PwCF and healthy volunteers (HV). In the laboratory, using either pilocarpine or exercise to induce sweat, the CF Patch demonstrated strong correlations with sweat chloride measured by pilocarpine-induced chloridometry. In remote settings, exercise-induced sweat chlorides measured using the CF patch were strongly correlated with in-laboratory exercise-induced CF patch sweat chlorides in HV but had a weaker correlation in PwCF. For PwCF on CFTR modulators, there was greater day-to-day variability in sweat chloride compared to HV, which highlights the limitations of assessing CFTR modulator efficacy and pharmacodynamics based on a single in-laboratory chloridometry measurement. Moreover, these findings demonstrate that the CF Patch is suitable as a remote management device capable of measuring serial sweat chloride concentrations and offers the potential of monitoring the efficacy of CF medication regimens but should not replace pilocarpine-based chloridometry for making a CF diagnosis.
- 9 June 2025
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 2 (6) , 371-372
Wearable electrochemical biosensors for remote hydration and health management
- 9 June 2025
- Published by Springer Nature in Nature Reviews Electrical Engineering
- Vol. 2 (6) , 371-372
Wearable electrochemical biosensors for remote hydration and health management
- Top Cited PapersOpen Access
- 1 February 2025
- Published by Springer Nature in npj Digital Medicine
- Vol. 8 (1) , 1-12
Wearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers
Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors. Here we present a closed-loop electrochemical/biophysical wearable sensing device and algorithms that directly measure whole-body sweat loss, sweating rate, sodium concentration, and sodium loss with electrode arrays embedded in a microfluidic channel. The device contains two temperature sensors for skin temperature and thermal flux recordings, and an accelerometer for real-time monitoring of activity level. An onboard haptic module enables vibratory feedback cues to the wearer once critical sweat loss thresholds are reached. Data is stored onboard in memory and autonomously transmitted via Bluetooth to a smartphone and cloud portal. Field studies conducted in physically demanding activities demonstrate the key capabilities of this platform to inform hydration interventions in highly challenging real-world settings.
- 1 February 2025
- Published by Springer Nature in npj Digital Medicine
- Vol. 8 (1) , 1-12
Top Cited PapersOpen AccessWearable microfluidic biosensors with haptic feedback for continuous monitoring of hydration biomarkers in workers
Real-time monitoring of hydration biomarkers in tandem with biophysical markers can offer valuable physiological insights about heat stress and related thermoregulatory response. These metrics have been challenging to achieve with wearable sensors. Here we present a closed-loop electrochemical/biophysical wearable sensing device and algorithms that directly measure whole-body sweat loss, sweating rate, sodium concentration, and sodium loss with electrode arrays embedded in a microfluidic channel. The device contains two temperature sensors for skin temperature and thermal flux recordings, and an accelerometer for real-time monitoring of activity level. An onboard haptic module enables vibratory feedback cues to the wearer once critical sweat loss thresholds are reached. Data is stored onboard in memory and autonomously transmitted via Bluetooth to a smartphone and cloud portal. Field studies conducted in physically demanding activities demonstrate the key capabilities of this platform to inform hydration interventions in highly challenging real-world settings.
- Top Cited Papers
- 4 September 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 16 (763) , eado5366
A skin-interfaced microfluidic platform supports dynamic sweat biochemical analysis during human exercise
Blood lactate concentration is an established circulating biomarker for measuring muscle acidity and can be evaluated for monitoring endurance, training routines, or athletic performance. Sweat is an alternative biofluid that may serve similar purposes and offers the advantage of noninvasive collection and continuous monitoring. The relationship between blood lactate and dynamic sweat biochemistry for wearable engineering applications in physiological fitness remains poorly defined. Here, we developed a microfluidic wearable band with an integrated colorimetric timer and biochemical assays that temporally captures sweat and measures pH and lactate concentration. A colorimetric silver nanoplasmonic assay was used to measure the concentration of lactate, and dye-conjugated SiO 2 nanoparticle–agarose composite materials supported dynamic pH analysis. We evaluated these sweat biomarkers in relation to blood lactate in human participant studies during cycling exercise of varying intensity. Iontophoresis-generated sweat pH from regions of actively working muscles decreased with increasing heart rate during exercise and was negatively correlated with blood lactate concentration. In contrast, sweat pH from nonworking muscles did not correlate with blood lactate concentration. Changes in sweat pH and blood lactate were observed in participants who did not regularly exercise but not in individuals who regularly exercised, suggesting a relationship to physical fitness and supporting further development for noninvasive, biochemical fitness evaluations.
- 4 September 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 16 (763) , eado5366
Top Cited PapersA skin-interfaced microfluidic platform supports dynamic sweat biochemical analysis during human exercise
Blood lactate concentration is an established circulating biomarker for measuring muscle acidity and can be evaluated for monitoring endurance, training routines, or athletic performance. Sweat is an alternative biofluid that may serve similar purposes and offers the advantage of noninvasive collection and continuous monitoring. The relationship between blood lactate and dynamic sweat biochemistry for wearable engineering applications in physiological fitness remains poorly defined. Here, we developed a microfluidic wearable band with an integrated colorimetric timer and biochemical assays that temporally captures sweat and measures pH and lactate concentration. A colorimetric silver nanoplasmonic assay was used to measure the concentration of lactate, and dye-conjugated SiO 2 nanoparticle–agarose composite materials supported dynamic pH analysis. We evaluated these sweat biomarkers in relation to blood lactate in human participant studies during cycling exercise of varying intensity. Iontophoresis-generated sweat pH from regions of actively working muscles decreased with increasing heart rate during exercise and was negatively correlated with blood lactate concentration. In contrast, sweat pH from nonworking muscles did not correlate with blood lactate concentration. Changes in sweat pH and blood lactate were observed in participants who did not regularly exercise but not in individuals who regularly exercised, suggesting a relationship to physical fitness and supporting further development for noninvasive, biochemical fitness evaluations.
- Top Cited Papers
- 31 March 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 13 (587)
Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management
A soft, wearable microfluidic platform collects and quantitatively analyzes sweat biomarkers to improve the diagnosis of cystic fibrosis.
- 31 March 2021
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 13 (587)
Top Cited PapersSoft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management
A soft, wearable microfluidic platform collects and quantitatively analyzes sweat biomarkers to improve the diagnosis of cystic fibrosis.
- Top Cited PapersOpen Access
- 11 December 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (50) , eabe3929
Skin-interfaced microfluidic system with personalized sweating rate and sweat chloride analytics for sports science applications
Advanced capabilities in noninvasive, in situ monitoring of sweating rate and sweat electrolyte losses could enable real-time personalized fluid-electrolyte intake recommendations. Established sweat analysis techniques using absorbent patches require post-collection harvesting and benchtop analysis of sweat and are thus impractical for ambulatory use. Here, we introduce a skin-interfaced wearable microfluidic device and smartphone image processing platform that enable analysis of regional sweating rate and sweat chloride concentration ([Cl−]). Systematic studies (n = 312 athletes) establish significant correlations for regional sweating rate and sweat [Cl−] in a controlled environment and during competitive sports under varying environmental conditions. The regional sweating rate and sweat [Cl−] results serve as inputs to algorithms implemented on a smartphone software application that predicts whole-body sweating rate and sweat [Cl−]. This low-cost wearable sensing approach could improve the accessibility of physiological insights available to sports scientists, practitioners, and athletes to inform hydration strategies in real-world ambulatory settings.
- 11 December 2020
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 6 (50) , eabe3929
Top Cited PapersOpen AccessSkin-interfaced microfluidic system with personalized sweating rate and sweat chloride analytics for sports science applications
Advanced capabilities in noninvasive, in situ monitoring of sweating rate and sweat electrolyte losses could enable real-time personalized fluid-electrolyte intake recommendations. Established sweat analysis techniques using absorbent patches require post-collection harvesting and benchtop analysis of sweat and are thus impractical for ambulatory use. Here, we introduce a skin-interfaced wearable microfluidic device and smartphone image processing platform that enable analysis of regional sweating rate and sweat chloride concentration ([Cl−]). Systematic studies (n = 312 athletes) establish significant correlations for regional sweating rate and sweat [Cl−] in a controlled environment and during competitive sports under varying environmental conditions. The regional sweating rate and sweat [Cl−] results serve as inputs to algorithms implemented on a smartphone software application that predicts whole-body sweating rate and sweat [Cl−]. This low-cost wearable sensing approach could improve the accessibility of physiological insights available to sports scientists, practitioners, and athletes to inform hydration strategies in real-world ambulatory settings.
- 12 October 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (23) , 4391-4403
Skin-interfaced soft microfluidic systems with modular and reusable electronics for in situ capacitive sensing of sweat loss, rate and conductivity
Important insights into human health can be obtained through the non-invasive collection and detailed analysis of sweat, a biofluid that contains a wide range of essential biomarkers. Skin-interfaced microfluidic platforms, characterized by soft materials and thin geometries, offer a collection of capabilities for in situ capture, storage, and analysis of sweat and its constituents. In ambulatory uses cases, the ability to provide real-time feedback on sweat loss, rate and content, without visual inspection of the device, can be important. This paper introduces a low-profile skin-interfaced system that couples disposable microfluidic sampling devices with reusable ‘stick-on’ electrodes and wireless readout electronics that remain isolated from the sweat. An ultra-thin capping layer on the microfluidic platform permits high-sensitivity, contactless capacitive measurements of both sweat loss and sweat conductivity. This architecture avoids the potential for corrosion of the sensing components and eliminates the need for cleaning/sterilizing the electronics, thereby resulting in a cost-effective platform that is simple to use. Optimized electrode designs follow from a combination of extensive benchtop testing, analytical calculations and FEA simulations for two sensing configurations: (1) sweat rate and loss, and (2) sweat conductivity, which contains information about electrolyte content. Both configurations couple to a flexible, wireless electronics platform that digitizes and transmits information to Bluetooth-enabled devices. On-body field testing during physical exercise validates the performance of the system in scenarios of practical relevance to human health and performance.
- 12 October 2020
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 20 (23) , 4391-4403
Skin-interfaced soft microfluidic systems with modular and reusable electronics for in situ capacitive sensing of sweat loss, rate and conductivity
Important insights into human health can be obtained through the non-invasive collection and detailed analysis of sweat, a biofluid that contains a wide range of essential biomarkers. Skin-interfaced microfluidic platforms, characterized by soft materials and thin geometries, offer a collection of capabilities for in situ capture, storage, and analysis of sweat and its constituents. In ambulatory uses cases, the ability to provide real-time feedback on sweat loss, rate and content, without visual inspection of the device, can be important. This paper introduces a low-profile skin-interfaced system that couples disposable microfluidic sampling devices with reusable ‘stick-on’ electrodes and wireless readout electronics that remain isolated from the sweat. An ultra-thin capping layer on the microfluidic platform permits high-sensitivity, contactless capacitive measurements of both sweat loss and sweat conductivity. This architecture avoids the potential for corrosion of the sensing components and eliminates the need for cleaning/sterilizing the electronics, thereby resulting in a cost-effective platform that is simple to use. Optimized electrode designs follow from a combination of extensive benchtop testing, analytical calculations and FEA simulations for two sensing configurations: (1) sweat rate and loss, and (2) sweat conductivity, which contains information about electrolyte content. Both configurations couple to a flexible, wireless electronics platform that digitizes and transmits information to Bluetooth-enabled devices. On-body field testing during physical exercise validates the performance of the system in scenarios of practical relevance to human health and performance.
- 3 September 2020
- Published by American Society for Engineering Education
- p. 9.64.1-9.64.12
A Microfluids Laboratory Teaching Module
- 3 September 2020
- Published by American Society for Engineering Education
- p. 9.64.1-9.64.12
A Microfluids Laboratory Teaching Module