Emil Toft Petersen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emil Toft Petersen has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- Maiken Stilling
Aarhus University Hospital
14 shared publications - Thomas Falstie-Jensen
Department of Orthopedic Surgery, Aarhus University Hospital, Aarhus, Denmark
4 shared publications - Jonathan Hugo Jürgens-Lahnstein
AutoRSA Research Group, Orthopedic Research Unit Aarhus University Hospital Aarhus Denmark
3 shared publications - Josephine Olsen Kipp
AutoRSA Research Group, Orthopaedic Research Unit, Aarhus University Hospital, Aarhus, Denmark
3 shared publications Sepp de Raedt
AutoRSA Research Group, Orthopaedic Research Unit Aarhus University Hospital Aarhus Denmark
3 shared publications- Theis Muncholm Thillemann
Department of Orthopaedic Surgery, Aarhus University Hospital, Aarhus, Denmark
3 shared publications
Latest Publications
- Open Access
- 7 February 2026
- Published by Springer Nature in Trials
- Vol. 27 (1)
Evaluation of femoral neck fracture migration after internal fixation with an angle stable implant compared with gold standard cannulated cancellous screws in young adults: study protocol for a clinical RCT using radiostereometric analysis
Hip fractures are most commonly suffered by elderly patients, but 2–11% of hip fractures affect younger patients. In young adults with femoral neck f
- 7 February 2026
- Published by Springer Nature in Trials
- Vol. 27 (1)
Open AccessEvaluation of femoral neck fracture migration after internal fixation with an angle stable implant compared with gold standard cannulated cancellous screws in young adults: study protocol for a clinical RCT using radiostereometric analysis
Hip fractures are most commonly suffered by elderly patients, but 2–11% of hip fractures affect younger patients. In young adults with femoral neck f
- Open Access
- 1 January 2026
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2026 (1) , 4780901
Corrective Osteotomy With Volar Plating of Distal Radius Malunions Using CT‐Based 3D Modeling: A Case Series of Four Patients
Distal radius malunion is the most common complication following distal radius fractures and may lead to reduced forearm rotation, distal radioulnar joint (DRUJ) instability, and wrist pain. Corrective osteotomy is particularly challenging in complex three‐dimensional (3D) deformities. We evaluated the feasibility and outcomes of CT‐based 3D planning for corrective osteotomy in four patients with symptomatic distal radius malunion. Surgical planning was based on mirrored 3D models of the contralateral healthy radius. Two patients underwent simultaneous foveal triangular fibrocartilage complex (TFCC) reinsertion, while a third underwent delayed TFCC reinsertion combined with ulnar shortening osteotomy. Patients were assessed preoperatively and at 1‐year follow‐up using CT‐based 3D bone models, dynamic radiostereometric analysis (dRSA) of DRUJ kinematics, radiographic parameters, clinical examination, and patient‐reported outcome measures (QuickDASH and PRWHE). Anatomical correction improved in all patients, with the greatest improvements observed in rotational alignment. Radiographic parameters improved in all cases, although adequate radial length was restored in only two patients. QuickDASH scores improved in three patients, and PRWHE scores improved in all four. DRUJ kinematics demonstrated improved stability in two patients, no change in one, and worsening in one. Grip strength remained unchanged, while wrist range of motion improved in one patient. CT‐based 3D planning was feasible in all cases and facilitated accurate correction of complex distal radius malunions, particularly rotational deformities. Bony realignment improved DRUJ stability with and without TFCC reinsertion but did not restore normal kinematics in all patients. These findings suggest that TFCC stabilization should be reserved for patients with persistent symptomatic DRUJ instability after osteotomy healing and rehabilitation.
- 1 January 2026
- Published by Wiley in Case Reports in Orthopedics
- Vol. 2026 (1) , 4780901
Open AccessCorrective Osteotomy With Volar Plating of Distal Radius Malunions Using CT‐Based 3D Modeling: A Case Series of Four Patients
Distal radius malunion is the most common complication following distal radius fractures and may lead to reduced forearm rotation, distal radioulnar joint (DRUJ) instability, and wrist pain. Corrective osteotomy is particularly challenging in complex three‐dimensional (3D) deformities. We evaluated the feasibility and outcomes of CT‐based 3D planning for corrective osteotomy in four patients with symptomatic distal radius malunion. Surgical planning was based on mirrored 3D models of the contralateral healthy radius. Two patients underwent simultaneous foveal triangular fibrocartilage complex (TFCC) reinsertion, while a third underwent delayed TFCC reinsertion combined with ulnar shortening osteotomy. Patients were assessed preoperatively and at 1‐year follow‐up using CT‐based 3D bone models, dynamic radiostereometric analysis (dRSA) of DRUJ kinematics, radiographic parameters, clinical examination, and patient‐reported outcome measures (QuickDASH and PRWHE). Anatomical correction improved in all patients, with the greatest improvements observed in rotational alignment. Radiographic parameters improved in all cases, although adequate radial length was restored in only two patients. QuickDASH scores improved in three patients, and PRWHE scores improved in all four. DRUJ kinematics demonstrated improved stability in two patients, no change in one, and worsening in one. Grip strength remained unchanged, while wrist range of motion improved in one patient. CT‐based 3D planning was feasible in all cases and facilitated accurate correction of complex distal radius malunions, particularly rotational deformities. Bony realignment improved DRUJ stability with and without TFCC reinsertion but did not restore normal kinematics in all patients. These findings suggest that TFCC stabilization should be reserved for patients with persistent symptomatic DRUJ instability after osteotomy healing and rehabilitation.
- 17 December 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (9) , 3387-3398
Similar tibial and femoral component fixation of mobile‐bearing and fixed‐bearing lateral unicompartmental knee arthroplasty: A radiostereometry study with 5‐year follow‐up
Purpose: To compare tibial and femoral component fixation of lateral unicompartmental knee arthroplasty (UKA) with mobile‐bearing (MB) and fixed‐bearing (FB) designs up to 5 years follow‐up. The primary outcome was mean tibial component maximal total point motion (MTPM) at 1‐year follow‐up. Methods: The Oxford lateral domed UKA ( n = 14) and the Oxford Fixed Lateral UKA ( n = 13) were inserted in 27 patients with posterolateral unicompartmental knee osteoarthritis. Tibial implants were cemented, while femoral implants were either cemented ( n = 17) or cementless ( n = 10). At baseline, 1‐, 2‐, and 5‐year follow‐up, radiostereometry (RSA) imaging, Oxford Knee Score (OKS) and EQ‐5D‐5L quality of life score were collected. A newly updated 1‐year migration threshold was used to determine 15‐year revision‐risk with migration above 0.4 mm termed ‘at‐risk’. Results: At 1‐year follow‐up, tibial implant MTPM was 0.47 mm (confidence interval [CI]: 0.32; 0.62) for MB UKA and 0.52 mm (CI: 0.36; 0.68) for FB UKA. Femoral implant MTPM was 0.56 mm (CI: 0.34; 0.79) for MB UKA and 0.54 mm (CI: 0.30; 0.77) for FB UKA. Migration patterns were similar between cemented and cementless femoral components. No differences in tibial implant MTPM were found between groups at follow‐up, with a mean difference of −0.06 (CI: −0.28; 0.15) at 2‐year and −0.06 (CI: −0.31; 0.18) at 5‐year follow‐up. Further, 16/25 (MB: 7/13, FB: 9/12) implants were in the “at‐risk” group for 15‐year revision. Both groups demonstrated clinically relevant improvements in OKS and European quality of life score (EQ‐5D‐5L), no differences between FB and MB were found. Conclusion: The MB and FB tibial components had similar good fixation and clinical improvement until 5 years of follow‐up. MTPM migration for both tibial groups was in the ‘at risk’ group for revision based on the newly established 1‐year migration threshold, but showed no measurable migration after the 1‐year follow‐up. Level of Evidence: Level III.
- 17 December 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 34 (9) , 3387-3398
Similar tibial and femoral component fixation of mobile‐bearing and fixed‐bearing lateral unicompartmental knee arthroplasty: A radiostereometry study with 5‐year follow‐up
Purpose: To compare tibial and femoral component fixation of lateral unicompartmental knee arthroplasty (UKA) with mobile‐bearing (MB) and fixed‐bearing (FB) designs up to 5 years follow‐up. The primary outcome was mean tibial component maximal total point motion (MTPM) at 1‐year follow‐up. Methods: The Oxford lateral domed UKA ( n = 14) and the Oxford Fixed Lateral UKA ( n = 13) were inserted in 27 patients with posterolateral unicompartmental knee osteoarthritis. Tibial implants were cemented, while femoral implants were either cemented ( n = 17) or cementless ( n = 10). At baseline, 1‐, 2‐, and 5‐year follow‐up, radiostereometry (RSA) imaging, Oxford Knee Score (OKS) and EQ‐5D‐5L quality of life score were collected. A newly updated 1‐year migration threshold was used to determine 15‐year revision‐risk with migration above 0.4 mm termed ‘at‐risk’. Results: At 1‐year follow‐up, tibial implant MTPM was 0.47 mm (confidence interval [CI]: 0.32; 0.62) for MB UKA and 0.52 mm (CI: 0.36; 0.68) for FB UKA. Femoral implant MTPM was 0.56 mm (CI: 0.34; 0.79) for MB UKA and 0.54 mm (CI: 0.30; 0.77) for FB UKA. Migration patterns were similar between cemented and cementless femoral components. No differences in tibial implant MTPM were found between groups at follow‐up, with a mean difference of −0.06 (CI: −0.28; 0.15) at 2‐year and −0.06 (CI: −0.31; 0.18) at 5‐year follow‐up. Further, 16/25 (MB: 7/13, FB: 9/12) implants were in the “at‐risk” group for 15‐year revision. Both groups demonstrated clinically relevant improvements in OKS and European quality of life score (EQ‐5D‐5L), no differences between FB and MB were found. Conclusion: The MB and FB tibial components had similar good fixation and clinical improvement until 5 years of follow‐up. MTPM migration for both tibial groups was in the ‘at risk’ group for revision based on the newly established 1‐year migration threshold, but showed no measurable migration after the 1‐year follow‐up. Level of Evidence: Level III.
- Open Access
- 7 July 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (11) , 3840-3852
Similar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double‐blinded controlled radiostereometry trial with 24 months of follow‐up
Purpose: To assess the influence of a higher constraint medial congruent (MC) versus a cruciate retaining (CR) (gold standard) polyethylene insert on the migration of cemented tibial and femoral components of the Persona Total Knee System. High‐constraint inserts may increase forces on components and potentially affect implant migration and long‐term fixation. Methods: A cohort of 66 patients with primary knee osteoarthritis received a cemented Persona total knee arthroplasty and were randomised to either an MC or a CR polyethylene insert. Tibial and femoral component migration was assessed using static radiostereometric analysis, with the first stereo‐radiograph taken supine on the first postoperative day (baseline) and again at 3‐, 12‐, and 24‐month follow‐up. Tibial and femoral component migration was evaluated in six degrees of freedom and as maximum total point motion (MTPM). Results: At the 12‐month follow‐up, the mean difference in tibial component MTPM was 0.04 mm (95% confidence interval [CI]: −0.21 to 0.28). The mean MTPM was 0.81 mm (95% CI: 0.64–0.99) in the MC group and 0.85 mm (95% CI: 0.68–1.03) in the CR group. Signed migrations were similar for the MC and the CR group throughout 24 months of follow‐up ( p > 0.09). At the 12‐month follow‐up, the mean difference in femoral component MTPM was 0.18 mm (95% CI: −0.17 to 0.53). The mean MTPM was 1.08 mm (95% CI: 0.83–1.32) in the MC group and 1.26 mm (95% CI: 1.01–1.51) in the CR group. The femoral components with MC insert had 0.18 mm (95% CI: 0.03–0.32) and 0.20 mm (95% CI: 0.01–0.39) more lateral migration at 3‐ and 12‐month follow‐up, respectively. At the 24‐month follow‐up, there was no statistically significant differences in migration for either translations, rotations or MTPM. Conclusions: Both tibial and femoral components had similar and acceptable fixation regardless of the type of polyethylene insert. Level of Evidence: Level I.
- 7 July 2025
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 33 (11) , 3840-3852
Open AccessSimilar fixation of total knee arthroplasty components with medial congruent and cruciate retaining polyethylene inserts. A randomised double‐blinded controlled radiostereometry trial with 24 months of follow‐up
Purpose: To assess the influence of a higher constraint medial congruent (MC) versus a cruciate retaining (CR) (gold standard) polyethylene insert on the migration of cemented tibial and femoral components of the Persona Total Knee System. High‐constraint inserts may increase forces on components and potentially affect implant migration and long‐term fixation. Methods: A cohort of 66 patients with primary knee osteoarthritis received a cemented Persona total knee arthroplasty and were randomised to either an MC or a CR polyethylene insert. Tibial and femoral component migration was assessed using static radiostereometric analysis, with the first stereo‐radiograph taken supine on the first postoperative day (baseline) and again at 3‐, 12‐, and 24‐month follow‐up. Tibial and femoral component migration was evaluated in six degrees of freedom and as maximum total point motion (MTPM). Results: At the 12‐month follow‐up, the mean difference in tibial component MTPM was 0.04 mm (95% confidence interval [CI]: −0.21 to 0.28). The mean MTPM was 0.81 mm (95% CI: 0.64–0.99) in the MC group and 0.85 mm (95% CI: 0.68–1.03) in the CR group. Signed migrations were similar for the MC and the CR group throughout 24 months of follow‐up ( p > 0.09). At the 12‐month follow‐up, the mean difference in femoral component MTPM was 0.18 mm (95% CI: −0.17 to 0.53). The mean MTPM was 1.08 mm (95% CI: 0.83–1.32) in the MC group and 1.26 mm (95% CI: 1.01–1.51) in the CR group. The femoral components with MC insert had 0.18 mm (95% CI: 0.03–0.32) and 0.20 mm (95% CI: 0.01–0.39) more lateral migration at 3‐ and 12‐month follow‐up, respectively. At the 24‐month follow‐up, there was no statistically significant differences in migration for either translations, rotations or MTPM. Conclusions: Both tibial and femoral components had similar and acceptable fixation regardless of the type of polyethylene insert. Level of Evidence: Level I.
- Open Access
- 3 June 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (6) , 506-515
One-year follow-up of 20 patients undergoing the Latarjet procedure
Aims: The Latarjet procedure is the treatment of choice for patients who have recurrent anterior shoulder instability with glenoid bone loss. However, the stabilizing effect of the Latarjet procedure in patients is sparsely described. The aim of this study was to evaluate the glenohumeral joint (GHJ) kinematics during an apprehension-relocation test in patients with anterior shoulder instability before and after their Latarjet procedure, and in comparison with their contralateral healthy shoulder.Methods: A total of 20 patients scheduled for the Latarjet procedure were enrolled. The patients were examined preoperatively with bilateral radiostereometric analysis (RSA) and one year after surgery on the operated shoulder with an apprehension-relocation test. Bone models were obtained from CT scans and aligned with the RSA images. The GHJ kinematics was evaluated with two methods: the humeral head centre location relative to the glenoid centre, and the GHJ contact point relative to the glenoid centre.Results: No difference in GHJ kinematics was found between the healthy and the postoperative GHJ. Compared with the preoperative injured shoulder, the postoperative mean (95% CI) humeral head centre was 0.8 mm (0.1 to 1.4) more superior and 0.7 mm (-0.1. to 1.4) more posterior during the apprehension test, and 0.5 mm (0.0 to 1.1) more posterior during the relocation test. The postoperative contact point was posterior to the coracoid bone block and 0.9 mm (-0.2 to 2.0) more posterior than in the preoperative injured shoulder during the apprehension test. The articulating area of the coracoid bone block was decreased by 63.9% (75.5 to 114.6) one year after surgery.Conclusion: The Latarjet procedure restored the humeral head centre location posterior and superior, and the contact point posterior, to the coracoid bone block. This suggests that the stabilizing effect of the GHJ following the Latarjet procedure is primarily due to the conjoined tendon rather than the coracoid bone block itself.Cite this article: Bone Joint Res 2025;14(6):506–515.
- 3 June 2025
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 14 (6) , 506-515
Open AccessOne-year follow-up of 20 patients undergoing the Latarjet procedure
Aims: The Latarjet procedure is the treatment of choice for patients who have recurrent anterior shoulder instability with glenoid bone loss. However, the stabilizing effect of the Latarjet procedure in patients is sparsely described. The aim of this study was to evaluate the glenohumeral joint (GHJ) kinematics during an apprehension-relocation test in patients with anterior shoulder instability before and after their Latarjet procedure, and in comparison with their contralateral healthy shoulder.Methods: A total of 20 patients scheduled for the Latarjet procedure were enrolled. The patients were examined preoperatively with bilateral radiostereometric analysis (RSA) and one year after surgery on the operated shoulder with an apprehension-relocation test. Bone models were obtained from CT scans and aligned with the RSA images. The GHJ kinematics was evaluated with two methods: the humeral head centre location relative to the glenoid centre, and the GHJ contact point relative to the glenoid centre.Results: No difference in GHJ kinematics was found between the healthy and the postoperative GHJ. Compared with the preoperative injured shoulder, the postoperative mean (95% CI) humeral head centre was 0.8 mm (0.1 to 1.4) more superior and 0.7 mm (-0.1. to 1.4) more posterior during the apprehension test, and 0.5 mm (0.0 to 1.1) more posterior during the relocation test. The postoperative contact point was posterior to the coracoid bone block and 0.9 mm (-0.2 to 2.0) more posterior than in the preoperative injured shoulder during the apprehension test. The articulating area of the coracoid bone block was decreased by 63.9% (75.5 to 114.6) one year after surgery.Conclusion: The Latarjet procedure restored the humeral head centre location posterior and superior, and the contact point posterior, to the coracoid bone block. This suggests that the stabilizing effect of the GHJ following the Latarjet procedure is primarily due to the conjoined tendon rather than the coracoid bone block itself.Cite this article: Bone Joint Res 2025;14(6):506–515.
- 14 November 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_18) , 24
THE PREOPERATIVE GAIT PATTERN IS ASSOCIATED WITH MIGRATION OF TOTAL KNEE ARTHROPLASTY: AN EXPLORATORY RADIOSTEREOMETRY STUDY WITH TWO YEARS’ FOLLOW-UP
Introduction: Knee osteoarthritis often causes malalignment and altering bone load. This malalignment is corrected during total knee arthroplasty surgery, balancing the ligaments. Nonetheless, preoperative gait patterns may influence postoperative prosthesis load and bone support. Thus, the purpose is to investigate the impact of preoperative gait patterns on postoperative femoral and tibial component migration in total knee arthroplasty.Method: In a prospective cohort study, 66 patients with primary knee osteoarthritis undergoing cemented Persona total knee arthroplasty were assessed. Preoperative knee kinematics was analyzed through dynamic radiostereometry and motion capture, categorizing patients into four homogeneous gait patterns. The four subgroups were labeled as the flexion group (n=20), the abduction (valgus) group (n=17), the anterior drawer group (n=10), and the tibial external rotation group (n=19). The femoral and tibial component migration was measured using static radiostereometry taken supine on the postoperative day (baseline) and 3-, 12-, and 24- months after surgery. Migration was evaluated as maximum total point motion.Result: Of the preoperatively defined four subgroups, the abduction group with a valgus-characterized gait pattern exhibited the highest migration for both the femoral (1.64 mm (CI95% 1.25; 2.03)) and tibial (1.21 mm (CI95% 0.89; 1.53)) components at 24-month follow-up. For the femoral components, the abduction group migrated 0.6 mm (CI95% 0.08; 1.12) more than the external rotation group at 24 months. For the tibial components, the abduction group migrated 0.43 mm (CI95% 0.16; 0.70) more than the external rotation group at 3 months. Furthermore, at 12- and 24-months follow-up the abduction group migrated 0.39 mm (95%CI 0.04; 0.73) and 0.45 mm (95%CI 0.01; 0.89) more than the flexion group, respectively.Conclusion: A preoperative valgus-characterized gait pattern seems to increase femoral and tibial component migration until 2 years of follow-up. This suggests that the implant fixation depends on load distributions originating from specific preoperative gait patterns.
- 14 November 2024
- Published by British Editorial Society of Bone & Joint Surgery in Orthopaedic Proceedings
- Vol. 106-B (SUPP_18) , 24
THE PREOPERATIVE GAIT PATTERN IS ASSOCIATED WITH MIGRATION OF TOTAL KNEE ARTHROPLASTY: AN EXPLORATORY RADIOSTEREOMETRY STUDY WITH TWO YEARS’ FOLLOW-UP
Introduction: Knee osteoarthritis often causes malalignment and altering bone load. This malalignment is corrected during total knee arthroplasty surgery, balancing the ligaments. Nonetheless, preoperative gait patterns may influence postoperative prosthesis load and bone support. Thus, the purpose is to investigate the impact of preoperative gait patterns on postoperative femoral and tibial component migration in total knee arthroplasty.Method: In a prospective cohort study, 66 patients with primary knee osteoarthritis undergoing cemented Persona total knee arthroplasty were assessed. Preoperative knee kinematics was analyzed through dynamic radiostereometry and motion capture, categorizing patients into four homogeneous gait patterns. The four subgroups were labeled as the flexion group (n=20), the abduction (valgus) group (n=17), the anterior drawer group (n=10), and the tibial external rotation group (n=19). The femoral and tibial component migration was measured using static radiostereometry taken supine on the postoperative day (baseline) and 3-, 12-, and 24- months after surgery. Migration was evaluated as maximum total point motion.Result: Of the preoperatively defined four subgroups, the abduction group with a valgus-characterized gait pattern exhibited the highest migration for both the femoral (1.64 mm (CI95% 1.25; 2.03)) and tibial (1.21 mm (CI95% 0.89; 1.53)) components at 24-month follow-up. For the femoral components, the abduction group migrated 0.6 mm (CI95% 0.08; 1.12) more than the external rotation group at 24 months. For the tibial components, the abduction group migrated 0.43 mm (CI95% 0.16; 0.70) more than the external rotation group at 3 months. Furthermore, at 12- and 24-months follow-up the abduction group migrated 0.39 mm (95%CI 0.04; 0.73) and 0.45 mm (95%CI 0.01; 0.89) more than the flexion group, respectively.Conclusion: A preoperative valgus-characterized gait pattern seems to increase femoral and tibial component migration until 2 years of follow-up. This suggests that the implant fixation depends on load distributions originating from specific preoperative gait patterns.
- 1 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (10) , 1165-1175
Elbow kinematics with increased lengthening of a radial head arthroplasty evaluated with dynamic radiostereometric analysis
Aims: The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).Methods: Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.Results: The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly.Conclusion: The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA.Cite this article: Bone Joint J 2024;106-B(10):1165–1175.
- 1 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (10) , 1165-1175
Elbow kinematics with increased lengthening of a radial head arthroplasty evaluated with dynamic radiostereometric analysis
Aims: The aim of this study was to evaluate the kinematics of the elbow following increasing length of the radius with implantation of radial head arthroplasties (RHAs) using dynamic radiostereometry (dRSA).Methods: Eight human donor arms were examined by dRSA during motor-controlled flexion and extension of the elbow with the forearm in an unloaded neutral position, and in pronation and supination with and without a 10 N valgus or varus load, respectively. The elbows were examined before and after RHA with stem lengths of anatomical size, + 2 mm, and + 4 mm. The ligaments were maintained intact by using a step-cut lateral humeral epicondylar osteotomy, allowing the RHAs to be repeatedly exchanged. Bone models were obtained from CT scans, and specialized software was used to match these models with the dRSA recordings. The flexion kinematics of the elbow were described using anatomical coordinate systems to define translations and rotations with six degrees of freedom.Results: The greatest kinematic changes in the elbows were seen with the longest, + 4 mm, implant, which imposed a mean joint distraction of 2.8 mm in the radiohumeral joint and of 1.1 mm in the ulnohumeral joint, an increased mean varus angle of up to 2.4° for both the radius and the ulna, a mean shift of the radius of 2.0 mm in the ulnar direction, and a mean shift of the ulna of 1.0 mm posteriorly.Conclusion: The kinematics of the elbow deviated increasingly from those of the native joint with a 2 mm to a 4 mm lengthening of the radius. This confirms the importance of restoring the natural length of the radius when undertaking RHA.Cite this article: Bone Joint J 2024;106-B(10):1165–1175.
- 1 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (10) , 1133-1140
Glenohumeral joint kinematics during apprehension-relocation test in patients with anterior shoulder instability and glenoid bone loss
Aims: This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder.Methods: A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid.Results: During the apprehension test, the centre of the humeral head was 1.0 mm (95% CI 0.0 to 2.0) more inferior on the glenoid for the ASI shoulder compared with the healthy shoulder. Furthermore, the contact point of the ASI shoulder was 1.4 mm (95% CI 0.3 to 2.5) more anterior and 2.0 mm (95% CI 0.8 to 3.1) more inferior on the glenoid compared with the healthy shoulder. The contact point of the ASI shoulder was 1.2 mm (95% CI 0.2 to 2.6) more anterior during the apprehension test compared to the relocation test.Conclusion: The humeral head centre was located more inferior, and the GHJ contact point was located both more anterior and inferior during the apprehension test for the ASI shoulders than the healthy shoulders. Furthermore, the contact point displacement between the apprehension and relocation test revealed increased joint laxity for the ASI shoulder than the healthy shoulders. These results contribute to existing knowledge that ASI shoulders with glenoid bone loss may also suffer from inferior shoulder instability.Cite this article: Bone Joint J 2024;106-B(10):1133–1140.
- 1 October 2024
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 106-B (10) , 1133-1140
Glenohumeral joint kinematics during apprehension-relocation test in patients with anterior shoulder instability and glenoid bone loss
Aims: This study aimed to quantify the shoulder kinematics during an apprehension-relocation test in patients with anterior shoulder instability (ASI) and glenoid bone loss using the radiostereometric analysis (RSA) method. Kinematics were compared with the patient’s contralateral healthy shoulder.Methods: A total of 20 patients with ASI and > 10% glenoid bone loss and a healthy contralateral shoulder were included. RSA imaging of the patient’s shoulders was performed during a repeated apprehension-relocation test. Bone volume models were generated from CT scans, marked with anatomical coordinate systems, and aligned with the digitally reconstructed bone projections on the RSA images. The glenohumeral joint (GHJ) kinematics were evaluated in the anteroposterior and superoinferior direction of: the humeral head centre location relative to the glenoid centre; and the humeral head contact point location on the glenoid.Results: During the apprehension test, the centre of the humeral head was 1.0 mm (95% CI 0.0 to 2.0) more inferior on the glenoid for the ASI shoulder compared with the healthy shoulder. Furthermore, the contact point of the ASI shoulder was 1.4 mm (95% CI 0.3 to 2.5) more anterior and 2.0 mm (95% CI 0.8 to 3.1) more inferior on the glenoid compared with the healthy shoulder. The contact point of the ASI shoulder was 1.2 mm (95% CI 0.2 to 2.6) more anterior during the apprehension test compared to the relocation test.Conclusion: The humeral head centre was located more inferior, and the GHJ contact point was located both more anterior and inferior during the apprehension test for the ASI shoulders than the healthy shoulders. Furthermore, the contact point displacement between the apprehension and relocation test revealed increased joint laxity for the ASI shoulder than the healthy shoulders. These results contribute to existing knowledge that ASI shoulders with glenoid bone loss may also suffer from inferior shoulder instability.Cite this article: Bone Joint J 2024;106-B(10):1133–1140.
- Open Access
- 9 May 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 13 (5) , 226-236
Stable polyethylene inlay fixation and low polyethylene wear rate in fixed-bearing total knee arthroplasty at five to six years’ follow-up
Aims: Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.Methods: A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.Results: At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041).Conclusion: The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear.Cite this article: Bone Joint Res 2024;13(5):226–236.
- 9 May 2024
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Research
- Vol. 13 (5) , 226-236
Open AccessStable polyethylene inlay fixation and low polyethylene wear rate in fixed-bearing total knee arthroplasty at five to six years’ follow-up
Aims: Micromotion of the polyethylene (PE) inlay may contribute to backside PE wear in addition to articulate wear of total knee arthroplasty (TKA). Using radiostereometric analysis (RSA) with tantalum beads in the PE inlay, we evaluated PE micromotion and its relationship to PE wear.Methods: A total of 23 patients with a mean age of 83 years (77 to 91), were available from a RSA study on cemented TKA with Maxim tibial components (Zimmer Biomet). PE inlay migration, PE wear, tibial component migration, and the anatomical knee axis were evaluated on weightbearing stereoradiographs. PE inlay wear was measured as the deepest penetration of the femoral component into the PE inlay.Results: At mean six years’ follow-up, the PE wear rate was 0.08 mm/year (95% confidence interval 0.06 to 0.09 mm/year). PE inlay external rotation was below the precision limit and did not influence PE wear. Varus knee alignment did not influence PE wear (p = 0.874), but increased tibial component total translation (p = 0.041).Conclusion: The PE inlay was well fixed and there was no relationship between PE stability and PE wear. The PE wear rate was low and similar in the medial and lateral compartments. Varus knee alignment did not influence PE wear.Cite this article: Bone Joint Res 2024;13(5):226–236.
- Open Access
- 21 April 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 32 (6) , 1492-1506
Dynamic radiostereometry can objectively quantify the kinematic laxity patterns and rotation instability of the knee during a pivot‐shift test
Purpose: The pivot‐shift test is used to clinically assess knee instability in patients with anterior cruciate ligament (ACL) lesions; however, it has low interobserver reliability. Dynamic radiostereometry (dRSA) is a highly precise and noninvasive method for the objective evaluation of joint kinematics. The purpose of this study was to quantify precise knee kinematics during a pivot‐shift test using dRSA imaging.Method: Eight human donor legs, including hemipelvises, were evaluated. Arthroscopic intervention was performed inducing ligament lesions in the ACL, and anterolateral ligament (ALL) section was performed as a capsular incision. The pivot‐shift test was recorded with dRSA on knees with intact ligaments, ACL‐deficient and ACL + ALL‐deficient knees.Results: A pivot‐shift pattern was identifiable after ligament lesion, as a change in tibial posterior drawer velocity from 7.8 mm/s (95% CI: 3.7; 11.9) in ligament intact knees to 30.4 mm/s (95% CI 23.0; 38.8) after ACL lesion to 35.1 mm/s (95% CI 23.4; 46.7) after combined ACL‐ALL lesion. The anterior‐posterior drawer excursion increased from 2.8 mm (95% CI 2.1; 3.4) in ligament intact knees to 7.2 mm (95% CI 5.5; 8.9) after ACL lesion to 7.6 mm (95% CI 5.5; 9.8) after combined lesion. A statistically significant increase in tibial external rotation towards the end of the pivot‐shift motion was observed when progressing from intact to ACL + ALL‐deficient knees (p < 0.023).Conclusion: This experimental study demonstrates the feasibility of dRSA to objectively quantify the kinematic laxity patterns of the knee during the pivot‐shift test. The dynamic parameters obtained through dRSA revealed the kinematic changes from ACL to combined ACL‐ALL ligament lesion.Level of Evidence: Not applicable.
- 21 April 2024
- Published by Wiley in Knee Surgery, Sports Traumatology, Arthroscopy
- Vol. 32 (6) , 1492-1506
Open AccessDynamic radiostereometry can objectively quantify the kinematic laxity patterns and rotation instability of the knee during a pivot‐shift test
Purpose: The pivot‐shift test is used to clinically assess knee instability in patients with anterior cruciate ligament (ACL) lesions; however, it has low interobserver reliability. Dynamic radiostereometry (dRSA) is a highly precise and noninvasive method for the objective evaluation of joint kinematics. The purpose of this study was to quantify precise knee kinematics during a pivot‐shift test using dRSA imaging.Method: Eight human donor legs, including hemipelvises, were evaluated. Arthroscopic intervention was performed inducing ligament lesions in the ACL, and anterolateral ligament (ALL) section was performed as a capsular incision. The pivot‐shift test was recorded with dRSA on knees with intact ligaments, ACL‐deficient and ACL + ALL‐deficient knees.Results: A pivot‐shift pattern was identifiable after ligament lesion, as a change in tibial posterior drawer velocity from 7.8 mm/s (95% CI: 3.7; 11.9) in ligament intact knees to 30.4 mm/s (95% CI 23.0; 38.8) after ACL lesion to 35.1 mm/s (95% CI 23.4; 46.7) after combined ACL‐ALL lesion. The anterior‐posterior drawer excursion increased from 2.8 mm (95% CI 2.1; 3.4) in ligament intact knees to 7.2 mm (95% CI 5.5; 8.9) after ACL lesion to 7.6 mm (95% CI 5.5; 9.8) after combined lesion. A statistically significant increase in tibial external rotation towards the end of the pivot‐shift motion was observed when progressing from intact to ACL + ALL‐deficient knees (p < 0.023).Conclusion: This experimental study demonstrates the feasibility of dRSA to objectively quantify the kinematic laxity patterns of the knee during the pivot‐shift test. The dynamic parameters obtained through dRSA revealed the kinematic changes from ACL to combined ACL‐ALL ligament lesion.Level of Evidence: Not applicable.