HYHirotake Yamamori

Hirotake Yamamori

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hirotake Yamamori has a total of 165 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Demonstration of Simultaneous Optical Transition-Edge Sensors Readout Using Microwave SQUID Multiplexer with 5 MHz Flux Ramp Modulation

    by Ryota Hayakawa, Daiji Fukuda, Kaori Hattori, Fuminori Hirayama, Takahiro Kikuchi, Satoshi Kohjiro, Akira Sato, Hirotake Yamamori


  • A 320-keV Spectrometer Based on 8-Pixel Transition Edge Sensor With Trilayer Membrane and Novel Numerical Analysis

    by Takahiro Kikuchi, Go Fujii, Ryota Hayakawa, Ryan Smith, Fuminori Hirayama, Yasushi Sato, Satoshi Kohjiro, Masahiro Ukibe, Masashi Ohno, Akira Sato, et al.

    A 320-keV spectrometer based on an 8-pixel transition edge sensor (TES) has been developed. It involves a unique 7-μm thick membrane consisting of silicon dioxide (SiO 2 ), silicon nitride (Si x N y ), and SiO 2 . This membrane supports a 0.8-mm thick Sn absorber with suitable stopping power for photon energy E=320 keV and is applicable up to E≈0.7 MeV. Our trilayer membrane exhibits the same thermal conductance as conventional 1-μm thick Si x N y one, i.e., G≈1.2 nW/K at the critical temperature of 115 mK. We carryoutthe spectroscopy using a 51 Cr radiationsourceand simultaneously read out the 8 pixels with a microwave SQUID multiplexer. We find a linear broadening trend be-tween the pulse peak and pulse area, even after a correction of the baseline drift due to time-varied temperature of our cryocooler. Based on the relationship, we analyze the data and succeed in avoiding degradation of the energy resolu-tion in spectra. The resultant full-width-half-maximum (FWHM) energy resolution ΔEFWHM of the measured 6 pix-els satisfies ΔE FWHM 220 keV to our knowledge.


  • Gamma-ray transition edge sensor with a thick SiO2/SixNy/SiO2 membrane

    by T. Kikuchi, G. Fujii, R. Hayakawa, R. Smith, F. Hirayama, Y. Sato, S. Kohjiro, M. Ukibe, M. Ohno, A. Sato, et al.

    Thick membranes of the gamma-ray transition-edge sensor (γ -TES) generally exhibit great mechanical strength and can support a bulk metal absorber typical for γ -TES. However, for conventional silicon-nitride (SixNy) membranes, thermal conductance (G) is proportional to the thickness, indicating that thicker membranes provide larger thermal-fluctuation noise in TESs. We propose a thick-trilayer membrane consisting of the silicon oxide (SiO2), SixNy, and SiO2 layers. The SixNy layer accounts for 5.8 μm of the total 6.9 μm, and thus, it is expected to be hard compared with conventional SixNy membranes with a typical thickness below 1 μm. G of the trilayer membrane is characterized as a function of heat-transport distance (L), and the G-L relation follows that of the intermediate model between ballistic and diffusive transports. Resulting G of the thick-trilayer membrane is 1.1–1.7 nW/K, which is not far from the one reported by conventional SixNy membranes. Gamma-ray spectroscopy around 93 keV is carried out based on series biased 5-pixels TES. The best full-width-half-maximum energy resolution among all pixels under characterization is 43.1 ± 1.6 eV for 93-keV, which is close to the median value of a state-of-the-art 236-pixels γ -TES in the literature. The measured low-frequency noise can be represented by theoretical phonon noise and its excess component with the same order as conventional ones. The thick-trilayer membrane is demonstrated to be able to work without any problems in a γ -TES regime.


  • Thermal management of a 3D packaging structure for superconducting quantum annealing machines

    by Wei Feng, Katsuya Kikuchi, Mutsuo Hidaka, Hirotake Yamamori, Yuuki Araga, Kazumasa Makise, Shiro Kawabata

    Quantum annealing (QA) is a computing paradigm for solving combinatorial optimization problems by finding the low-energy configurations of complicated Ising models through quantum fluctuation. Recently, because of the strictly limited number of superconducting qubits per chip, three-dimensional (3D) integrated technologies have attracted great attention for realizing a practical large-scale QA machine. Because a cryogenic environment is required for qubit chip operation, the less-effective heat transfer in the stacked structure has become a major concern. In the present paper, a method to realize a sufficiently low temperature for quantum operation in large-scale superconducting QA machines based on 3D packaging technology is proposed and demonstrated numerically. We reveal that the heating in such a 3D structure, which seriously reduces the quantum coherence of qubit chips, is effectively prevented by adding through-silicon vias (TSVs). Accordingly, the temperature of the qubit chip is drastically reduced from 57.8 mK to 16.4 mK. Our results indicate that using TSVs are a powerful and simple approach to realizing practical large-scale superconducting QA machines.


  • Low-noise microwave SQUID multiplexed readout of 38 x-ray transition-edge sensor microcalorimeters

    by Y. Nakashima, F. Hirayama, S. Kohjiro, H. Yamamori, S. Nagasawa, A. Sato, S. Yamada, R. Hayakawa, N. Y. Yamasaki, K. Mitsuda, et al.

    We report very-low-noise, fast-response, middle-scale multiplexing in a microwave superconducting quantum interference device multiplexer (MW-Mux) as a transition-edge sensor (TES) readout. Our MW-Mux is able to read 40 channels with 500 kHz sampling and has a low readout noise of 0.9   μ Φ 0 / Hz (where Φ 0 is the magnetic flux quantum), equivalent to 9   pA / Hz . By contrast, a multiplexer of less than 10 pixels with 500 kHz sampling and ∼ 2   μ Φ 0 / Hz readout noise has so far been reported in the literature. Owing to the 500 kHz sampling, our MW-Mux exhibits a fast response to detect a TES pulse with a rise time around 12   μ s . We demonstrated simultaneous readout of 38 pixels from an array of x-ray TES microcalorimeters. The measured full-width values at half-maximum spectral resolution ranged from 2.79 to 4.56 eV, with a median value of 3.30 eV at 5.9 keV, including a ∼ 10 % contribution of readout noise, i.e., 0.9–1.7 eV.


  • Open Access

    Flattened remnant-field distribution in superconducting bilayer

    by Y. Tanaka, H. Yamamori, T. Yanagisawa, S. Ooi, M. Tachiki, S. Arisawa


  • Investigation of Large Coupling Between TES X-Ray Microcalorimeter and Microwave Multiplexer Based on Microstrip SQUID

    by Yuki Nakashima, Fuminori Hirayama, Satoshi Kohjiro, Hirotake Yamamori, Shuichi Nagasawa, Akira Sato, Noriko Y. Yamasaki, Kazuhisa Mitsuda

    We report on the study of a microwave superconducting quantum interference device (SQUID) multiplexer (MW-Mux) with current noise lower than that of our typical transition-edge sensor (TES) X-ray microcalorimeter. A large mutual inductance, between SQUID loop and input inductor connected to a TES X-ray microcalorimeter in series, realizes such low current noise referred to the SQUID input, but also can cause undesirable resonances which affect the SQUID performances. In this paper, we developed the MW-Mux with mutual inductance of about 370 pH, which is six times larger than that of the previous one, by adopting a spiral input coil longer than a half wavelength at the readout microwave frequency. Its characteristics were evaluated, and the results showed that the distortion of the SQUID characteristics and the degradation of its noise performance were not clearly observed. Finally, we have developed a MW-Mux microstrip SQUID with a low current noise of $\rm \lt 20 pA/\sqrt{Hz}$ which is below the typical noise of our TES X-ray microcalorimeter, $\rm 30 pA/\sqrt{Hz}$ .


  • Degradation of Quality Factor of Superconducting Resonators by Remaining Metallic Film and Improved Fabrication Process Using Caldera Planarization

    by Tomoya Irimatsugawa, Hirotake Yamamori, Fuminori Hirayama, Shuichi Nagasawa, Go Fujii, Satoshi Kohjiro, Akira Sato, Daiji Fukuda, Mutsuo Hidaka, Yasushi Sato, et al.

    An important figure of merit in microwave supercon-ducting quantum interference device (SQUID) multiplexer (MW-MUX) is the quality factor of superconducting resonators. In AIST, the intrinsic quality factor $Q_i$ of the resonators in the MW-MUX chips degraded significantly compared to those in the resonator-only chips owing to something during the fabrication process. In this study, we have investigated the damage process by conducting con-trolled experiments and an SEM-EDX analysis. As a result, we con-firmed that the metallic layers (Pd and Nb) were not removed com-pletely and remained along the edge of the resonator, which resulted in the degradation of $Q_i$ . Further, we have invented a new process to overcome this imperfection during the removal of Pd layer using so called “caldera planarization”. The metal line that remained along the edge was not observed in the MW-MUX chips fabricated using this improved process. Finally, we have achieved $Q_i$ as high as that of resonator-only chips using the improved process.


  • Open Access

    Reliable packaging of Josephson voltage standard circuit for cryocooler operation

    by Hirotake Yamamori, Michitaka Maruyama, Yasutaka Amagai, Takeshi Shimazaki

    Reliable and easy fabricated packaging for a Josephson voltage standard circuit was proposed and the thermal stress and temperature distribution in the chip were numerically analyzed. The chip for programmable Josephson voltage standard circuits was bonded with InSn solder to a copper plate to achieve good thermal contact. Although this packaging allowed very good thermal contact, the chip sometimes broke due to thermal stress caused by a difference in the expansion coefficient between silicon and copper. Slits were thus added to the copper plate to reduce the thermal stress. The numerical analysis suggested that the slits reduce the thermal stress in the voltage standard chip, and thus reduce the risk of the chip cracking when it is cooled. The numerical analysis also suggested that the temperature increase in the chip was about 1 mK which caused a negligible reduction in the operating margin of the PJVS operation.


  • Open Access

    Abnormal Meissner state in a superconducting bilayer

    by Y. Tanaka, H. Yamamori, T. Yanagisawa, T. Nishio, S. Arisawa