Guillaume Gilbert
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guillaume Gilbert has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- An Tang
Department of Radiology, Centre Hospitalier de l’Université de Montréal (CHUM), Montreal, Canada
4 shared publications - Anton Volniansky
Department of Radiology, Radiation Oncology and Nuclear Medicine Université de Montréal Montréal Canada
4 shared publications Emmanuel Montagnon
Centre de Recherche du Centre Hospitalier de l'Université de Montréal (CRCHUM) Montréal Canada
3 shared publications- Amirhosein Baradaran Najar
Département de génie mécanique, Université de Sherbrooke , Sherbrooske, QC J1K 2R1
2 shared publications Audrey Fohlen
Laboratoire clinique de traitement de l’image (LCTI), Centre de recherche du Centre hospitalier de l’Université de Montréal (CRCHUM) , Montréal, QC H2X 0A9
2 shared publications- Christine Saint-Martin
McGill University Health Centre
2 shared publications
Latest Publications
- Open Access
- 28 November 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 996-1008
Prospective Comparison of DWI ‐Derived Virtual MR Elastography and Conventional MR Elastography in Metabolic Dysfunction‐Associated Steatotic Liver Disease and Healthy Volunteers
Background: Virtual MR elastography (VMRE) and MRE have been proposed for liver fibrosis staging in metabolic dysfunction‐associated steatotic liver disease (MASLD), but VMRE's diagnostic performance remains debated. Purpose: To assess the inter‐visit and inter‐reader reproducibility of fat‐uncorrected and fat‐corrected diffusion‐weighted imaging (DWI)‐based VMRE and to compare their diagnostic performance with MRE for liver fibrosis staging in the MASLD population. Study Type: Prospective. Population: Fifty four participants were enrolled: 43 with biopsy‐proven MASLD (age: 57.0 ± 9.0 years; 26 males) and 11 healthy volunteers (age: 31.0 ± 15.0 years; 4 males). Field Strength/Sequence: 3.0T, DWI ( b ‐values of 0, 200, and 1500 s/mm 2 ) for VMRE and phase‐contrast MRE at 60 Hz was performed. Assessment: VMRE‐derived shifted apparent diffusion coefficients (sADC) reproducibility and diagnostic performance; MRE‐derived stiffness diagnostic performance. Statistical Tests: Reproducibility was evaluated using intraclass correlation coefficients (ICC), within‐subject coefficient of variation (wCV), and bias and limits of agreement (LOA) in Bland–Altman analysis. Diagnostic performance was assessed with areas under the receiver operating characteristic curve (AUC) and compared with DeLong's test. p < 0.05 was considered statistically significant. Results: For inter‐visit agreement, the ICC of fat‐uncorrected and fat‐corrected sADC were 0.88 and 0.83; wCV were 0.120 ± 0.30 and 0.141 ± 0.31; bias and 95% LOA were (−0.03 ± 0.18) × 10 −3 mm 2 /s and (−0.05 ± 0.33) × 10 −3 mm 2 /s, respectively. For inter‐reader agreement, the ICC of fat‐uncorrected and fat‐corrected VMRE were 0.99 and 0.99; wCV were 0.028 ± 0.011 and 0.039 ± 0.012, respectively; bias and 95% LOA were (−0.01 ± 0.03) × 10 −3 mm 2 /s and (−0.02 ± 0.05) × 10 −3 mm 2 /s, respectively. AUC of fat‐uncorrected, fat‐corrected sADC, and MRE‐derived stiffness for distinguishing fibrosis stages F0 versus ≥ F1 were 0.70 ± 0.17, 0.56 ± 0.18, and 0.87 ± 0.10; ≤ F1 versus ≥ F2 were 0.61 ± 0.16, 0.49 ± 0.17, and 0.86 ± 0.10; ≤ F2 versus ≥ F3 were 0.54 ± 0.16, 0.50 ± 0.16, and 0.89 ± 0.09; and ≤ F3 versus F4 were 0.58 ± 0.16, 0.55 ± 0.17, and 0.85 ± 0.11, respectively. MRE had significantly higher diagnostic performance than fat‐uncorrected and fat‐corrected VMRE for all fibrosis stages. Data Conclusion: VMRE has good reproducibility, but has lower fibrosis staging accuracy than MRE. Evidence Level: 1. Technical Efficacy: Stage 2.
- 28 November 2025
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 63 (4) , 996-1008
Open AccessProspective Comparison of DWI ‐Derived Virtual MR Elastography and Conventional MR Elastography in Metabolic Dysfunction‐Associated Steatotic Liver Disease and Healthy Volunteers
Background: Virtual MR elastography (VMRE) and MRE have been proposed for liver fibrosis staging in metabolic dysfunction‐associated steatotic liver disease (MASLD), but VMRE's diagnostic performance remains debated. Purpose: To assess the inter‐visit and inter‐reader reproducibility of fat‐uncorrected and fat‐corrected diffusion‐weighted imaging (DWI)‐based VMRE and to compare their diagnostic performance with MRE for liver fibrosis staging in the MASLD population. Study Type: Prospective. Population: Fifty four participants were enrolled: 43 with biopsy‐proven MASLD (age: 57.0 ± 9.0 years; 26 males) and 11 healthy volunteers (age: 31.0 ± 15.0 years; 4 males). Field Strength/Sequence: 3.0T, DWI ( b ‐values of 0, 200, and 1500 s/mm 2 ) for VMRE and phase‐contrast MRE at 60 Hz was performed. Assessment: VMRE‐derived shifted apparent diffusion coefficients (sADC) reproducibility and diagnostic performance; MRE‐derived stiffness diagnostic performance. Statistical Tests: Reproducibility was evaluated using intraclass correlation coefficients (ICC), within‐subject coefficient of variation (wCV), and bias and limits of agreement (LOA) in Bland–Altman analysis. Diagnostic performance was assessed with areas under the receiver operating characteristic curve (AUC) and compared with DeLong's test. p < 0.05 was considered statistically significant. Results: For inter‐visit agreement, the ICC of fat‐uncorrected and fat‐corrected sADC were 0.88 and 0.83; wCV were 0.120 ± 0.30 and 0.141 ± 0.31; bias and 95% LOA were (−0.03 ± 0.18) × 10 −3 mm 2 /s and (−0.05 ± 0.33) × 10 −3 mm 2 /s, respectively. For inter‐reader agreement, the ICC of fat‐uncorrected and fat‐corrected VMRE were 0.99 and 0.99; wCV were 0.028 ± 0.011 and 0.039 ± 0.012, respectively; bias and 95% LOA were (−0.01 ± 0.03) × 10 −3 mm 2 /s and (−0.02 ± 0.05) × 10 −3 mm 2 /s, respectively. AUC of fat‐uncorrected, fat‐corrected sADC, and MRE‐derived stiffness for distinguishing fibrosis stages F0 versus ≥ F1 were 0.70 ± 0.17, 0.56 ± 0.18, and 0.87 ± 0.10; ≤ F1 versus ≥ F2 were 0.61 ± 0.16, 0.49 ± 0.17, and 0.86 ± 0.10; ≤ F2 versus ≥ F3 were 0.54 ± 0.16, 0.50 ± 0.16, and 0.89 ± 0.09; and ≤ F3 versus F4 were 0.58 ± 0.16, 0.55 ± 0.17, and 0.85 ± 0.11, respectively. MRE had significantly higher diagnostic performance than fat‐uncorrected and fat‐corrected VMRE for all fibrosis stages. Data Conclusion: VMRE has good reproducibility, but has lower fibrosis staging accuracy than MRE. Evidence Level: 1. Technical Efficacy: Stage 2.
- Open Access
- 10 November 2025
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 2 (6) , umaf038
Multifrequency MR elastography for grading inflammation in metabolic dysfunction-associated steatotic liver disease: a pilot study
Background: Noninvasive grading of liver inflammation in metabolic dysfunction-associated steatotic liver disease (MASLD) remains an unmet clinical need. Purpose: To evaluate the diagnostic performance of multifrequency MR elastography (MMRE) for grading liver inflammation and diagnosing metabolic dysfunction-associated steatohepatitis (MASH). Materials and methods: In this prospective, single-site study, participants underwent MMRE at 30, 40, and 60 Hz on a 3T system. Multifrequency dispersion coefficient (α), storage modulus (G'), loss modulus (G”), and magnitude of the shear modulus (|G*|) were computed. The reference standard was histopathological analysis of needle biopsy specimens. The MASLD activity score was computed to assign MASH status. Univariate and multivariable correlation and areas under the receiver operating characteristic curve (AUCs) were assessed. Results: Of the 72 participants enrolled, 60 (12 healthy, 48 MASLD) were analyzable. Correlations of α, G', G”, and |G*| with lobular inflammation grades were ρ = −0.62, P < .001; ρ = 0.46, P < .001; ρ = 0.39, P < .01; and ρ = 0.44, P < .001; and the corresponding correlations with ballooning ρ = −0.42, P < .001; ρ = 0.42, P < .001; ρ = 0.40, P < .001; and ρ = 0.41, P < .001. The correlation between α and lobular inflammation remained after adjusting for steatosis, ballooning, and fibrosis (β = −0.06, P < .001); and with ballooning after adjusting for steatosis, lobular inflammation, and fibrosis (β = −0.02, P < .01). AUCs of α were 0.85, 0.96, and 0.94, respectively, for distinguishing lobular inflammation grades 0 vs ≥1, ≤1 vs ≥2, and ≤2 vs 3; 0.84 and 0.78 for distinguishing ballooning grades 0 vs ≥1 and ≤1 vs 2; and 0.81 to 0.85 for diagnosing MASH. Conclusion: The multifrequency dispersion coefficient α was associated with histologic inflammation and should be further evaluated with external validation as a possible clinical marker in MASLD.
- 10 November 2025
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 2 (6) , umaf038
Open AccessMultifrequency MR elastography for grading inflammation in metabolic dysfunction-associated steatotic liver disease: a pilot study
Background: Noninvasive grading of liver inflammation in metabolic dysfunction-associated steatotic liver disease (MASLD) remains an unmet clinical need. Purpose: To evaluate the diagnostic performance of multifrequency MR elastography (MMRE) for grading liver inflammation and diagnosing metabolic dysfunction-associated steatohepatitis (MASH). Materials and methods: In this prospective, single-site study, participants underwent MMRE at 30, 40, and 60 Hz on a 3T system. Multifrequency dispersion coefficient (α), storage modulus (G'), loss modulus (G”), and magnitude of the shear modulus (|G*|) were computed. The reference standard was histopathological analysis of needle biopsy specimens. The MASLD activity score was computed to assign MASH status. Univariate and multivariable correlation and areas under the receiver operating characteristic curve (AUCs) were assessed. Results: Of the 72 participants enrolled, 60 (12 healthy, 48 MASLD) were analyzable. Correlations of α, G', G”, and |G*| with lobular inflammation grades were ρ = −0.62, P < .001; ρ = 0.46, P < .001; ρ = 0.39, P < .01; and ρ = 0.44, P < .001; and the corresponding correlations with ballooning ρ = −0.42, P < .001; ρ = 0.42, P < .001; ρ = 0.40, P < .001; and ρ = 0.41, P < .001. The correlation between α and lobular inflammation remained after adjusting for steatosis, ballooning, and fibrosis (β = −0.06, P < .001); and with ballooning after adjusting for steatosis, lobular inflammation, and fibrosis (β = −0.02, P < .01). AUCs of α were 0.85, 0.96, and 0.94, respectively, for distinguishing lobular inflammation grades 0 vs ≥1, ≤1 vs ≥2, and ≤2 vs 3; 0.84 and 0.78 for distinguishing ballooning grades 0 vs ≥1 and ≤1 vs 2; and 0.81 to 0.85 for diagnosing MASH. Conclusion: The multifrequency dispersion coefficient α was associated with histologic inflammation and should be further evaluated with external validation as a possible clinical marker in MASLD.
- Open Access
- 24 October 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (6) , 2525-2540
MR Elastography for Classification of Focal Liver Lesions Using Viscoelastic Parameters: A Pilot Study Based on Intrinsic and Extrinsic Activations
Background: Intrinsic activation MR elastography (iMRE) uses cardiovascular pulsations to assess tissue viscoelastic properties. Applying it to focal liver lesions extends its capabilities.Purpose: To assess the viscoelastic parameters of focal liver lesions measured by iMRE and compare its diagnostic performance with extrinsic MRE (eMRE) for differentiating malignant and benign lesions.Study type: Prospective.Population: A total of 55 participants underwent MRI with research MRE sequences; 32 participants with 17 malignant and 15 benign lesions underwent both iMRE and eMRE.Field Strength/Sequence: iMRE at ~1 Hz heart rate used a 3 T scanner with a modified four‐dimensional (4D)‐quantitative flow gradient‐echo phase contrast and low‐velocity encoding cardiac‐triggered technique. eMRE employed a gradient‐echo sequence at 30, 40, and 60 Hz.Assessment: Liver displacements were measured using 4D‐phase contrast and reconstructed via a nonlinear inversion algorithm to determine shear stiffness (SS) and damping ratio (DR). iMRE parameters were normalized to the corresponding values from the spleen. Lesions were manually segmented, and image quality was reviewed.Statistical Tests: Kruskal–Wallis, Mann–Whitney, Dunn's test, and areas under receiver operating characteristic curves (AUC) were assessed.Results: SS was significantly higher in malignant than benign lesions with iMRE at 1 Hz (3.69 ± 1.31 vs. 1.63 ± 0.45) and eMRE at 30 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), 40 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), and 60 Hz (7.32 ± 2.87 vs. 2.48 ± 1.12 kPa). DR was also significantly higher in malignant than benign lesions at 40 Hz (0.36 ± 0.11 vs. 0.21 ± 0.01) and 60 Hz (0.89 ± 0.86 vs. 0.22 ± 0.09). The AUC were 0.86 for iMRE SS, 0.87–0.98 for eMRE SS, 0.47 for iMRE DR, and 0.62–0.86 for eMRE DR.Data Conclusion: Cardiac‐activated iMRE can characterize liver lesions and differentiate malignant from benign lesions through normalized SS maps.Level of Evidence: 2Technical Efficacy: Stage 2
- 24 October 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (6) , 2525-2540
Open AccessMR Elastography for Classification of Focal Liver Lesions Using Viscoelastic Parameters: A Pilot Study Based on Intrinsic and Extrinsic Activations
Background: Intrinsic activation MR elastography (iMRE) uses cardiovascular pulsations to assess tissue viscoelastic properties. Applying it to focal liver lesions extends its capabilities.Purpose: To assess the viscoelastic parameters of focal liver lesions measured by iMRE and compare its diagnostic performance with extrinsic MRE (eMRE) for differentiating malignant and benign lesions.Study type: Prospective.Population: A total of 55 participants underwent MRI with research MRE sequences; 32 participants with 17 malignant and 15 benign lesions underwent both iMRE and eMRE.Field Strength/Sequence: iMRE at ~1 Hz heart rate used a 3 T scanner with a modified four‐dimensional (4D)‐quantitative flow gradient‐echo phase contrast and low‐velocity encoding cardiac‐triggered technique. eMRE employed a gradient‐echo sequence at 30, 40, and 60 Hz.Assessment: Liver displacements were measured using 4D‐phase contrast and reconstructed via a nonlinear inversion algorithm to determine shear stiffness (SS) and damping ratio (DR). iMRE parameters were normalized to the corresponding values from the spleen. Lesions were manually segmented, and image quality was reviewed.Statistical Tests: Kruskal–Wallis, Mann–Whitney, Dunn's test, and areas under receiver operating characteristic curves (AUC) were assessed.Results: SS was significantly higher in malignant than benign lesions with iMRE at 1 Hz (3.69 ± 1.31 vs. 1.63 ± 0.45) and eMRE at 30 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), 40 Hz (3.76 ± 1.12 vs. 2.60 ± 1.26 kPa), and 60 Hz (7.32 ± 2.87 vs. 2.48 ± 1.12 kPa). DR was also significantly higher in malignant than benign lesions at 40 Hz (0.36 ± 0.11 vs. 0.21 ± 0.01) and 60 Hz (0.89 ± 0.86 vs. 0.22 ± 0.09). The AUC were 0.86 for iMRE SS, 0.87–0.98 for eMRE SS, 0.47 for iMRE DR, and 0.62–0.86 for eMRE DR.Data Conclusion: Cardiac‐activated iMRE can characterize liver lesions and differentiate malignant from benign lesions through normalized SS maps.Level of Evidence: 2Technical Efficacy: Stage 2
- Open Access
- 23 August 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 113, 110223
Inter-visit and inter-reader reproducibility of multi-parametric diffusion-weighted MR imaging in longitudinally imaged patients with metabolic dysfunction-associated fatty liver disease and healthy volunteers.
- 23 August 2024
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 113, 110223
Open AccessInter-visit and inter-reader reproducibility of multi-parametric diffusion-weighted MR imaging in longitudinally imaged patients with metabolic dysfunction-associated fatty liver disease and healthy volunteers.
- 21 August 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (3) , 1480-1481
Editorial for “MR Assessment of Acute Changes of Cerebral Perfusion, Metabolism, and Blood–Brain Barrier Permeability in Response to Aerobic Exercise”
- 21 August 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (3) , 1480-1481
Editorial for “MR Assessment of Acute Changes of Cerebral Perfusion, Metabolism, and Blood–Brain Barrier Permeability in Response to Aerobic Exercise”
- Open Access
- 3 November 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (44) , eadh9853
The CALIPR framework for highly accelerated myelin water imaging with improved precision and sensitivity
Quantitative magnetic resonance imaging (MRI) techniques are powerful tools for the study of human tissue, but, in practice, their utility has been limited by lengthy acquisition times. Here, we introduce the Constrained, Adaptive, Low-dimensional, Intrinsically Precise Reconstruction (CALIPR) framework in the context of myelin water imaging (MWI); a quantitative MRI technique generally regarded as the most rigorous approach for noninvasive, in vivo measurement of myelin content. The CALIPR framework exploits data redundancy to recover high-quality images from a small fraction of an imaging dataset, which allowed MWI to be acquired with a previously unattainable sequence (fully sampled acquisition 2 hours:57 min:20 s) in 7 min:26 s (4.2% of the dataset, acceleration factor 23.9). CALIPR quantitative metrics had excellent precision (myelin water fraction mean coefficient of variation 3.2% for the brain and 3.0% for the spinal cord) and markedly increased sensitivity to demyelinating disease pathology compared to a current, widely used technique. The CALIPR framework facilitates drastically improved MWI and could be similarly transformative for other quantitative MRI applications.
- 3 November 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 9 (44) , eadh9853
Open AccessThe CALIPR framework for highly accelerated myelin water imaging with improved precision and sensitivity
Quantitative magnetic resonance imaging (MRI) techniques are powerful tools for the study of human tissue, but, in practice, their utility has been limited by lengthy acquisition times. Here, we introduce the Constrained, Adaptive, Low-dimensional, Intrinsically Precise Reconstruction (CALIPR) framework in the context of myelin water imaging (MWI); a quantitative MRI technique generally regarded as the most rigorous approach for noninvasive, in vivo measurement of myelin content. The CALIPR framework exploits data redundancy to recover high-quality images from a small fraction of an imaging dataset, which allowed MWI to be acquired with a previously unattainable sequence (fully sampled acquisition 2 hours:57 min:20 s) in 7 min:26 s (4.2% of the dataset, acceleration factor 23.9). CALIPR quantitative metrics had excellent precision (myelin water fraction mean coefficient of variation 3.2% for the brain and 3.0% for the spinal cord) and markedly increased sensitivity to demyelinating disease pathology compared to a current, widely used technique. The CALIPR framework facilitates drastically improved MWI and could be similarly transformative for other quantitative MRI applications.
- 7 May 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 79, 102476
Bridging the gap between constrained spherical deconvolution and diffusional variance decomposition via tensor‐valued diffusion MRI
- 7 May 2022
- Published by Elsevier in Medical Image Analysis
- Vol. 79, 102476
Bridging the gap between constrained spherical deconvolution and diffusional variance decomposition via tensor‐valued diffusion MRI
- 22 March 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 56 (4) , 1066-1067
Editorial for “Development of a Piezoelectric Actuated Tactile Stimulation Device for Population Receptive Field Mapping in Human Somatosensory Cortex with fMRI”
- 22 March 2022
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 56 (4) , 1066-1067
Editorial for “Development of a Piezoelectric Actuated Tactile Stimulation Device for Population Receptive Field Mapping in Human Somatosensory Cortex with fMRI”
- Open Access
- 1 June 2021
- Published by Elsevier in Neuroimage: Reports
- Vol. 1 (2)
Cerebral stiffness changes during visual stimulation: Differential physiological mechanisms characterized by opposing mechanical effects
- 1 June 2021
- Published by Elsevier in Neuroimage: Reports
- Vol. 1 (2)
Open AccessCerebral stiffness changes during visual stimulation: Differential physiological mechanisms characterized by opposing mechanical effects
- 1 May 2021
- Published by Elsevier in Medical Image Analysis
- Vol. 70, 101988
Magic DIAMOND: Multi-fascicle diffusion compartment imaging with tensor distribution modeling and tensor-valued diffusion encoding
- 1 May 2021
- Published by Elsevier in Medical Image Analysis
- Vol. 70, 101988
Magic DIAMOND: Multi-fascicle diffusion compartment imaging with tensor distribution modeling and tensor-valued diffusion encoding